Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Front Immunol ; 12: 690322, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34497602

RESUMO

A convalescent, non-severe, patient with COVID-19 was enrolled as a hyper-immune plasma voluntary donor by the Immuno-Hematology and Transfusion Unit of the Regina Elena National Cancer Institute in Rome, under the TSUNAMI national study criteria. During a nearly 6-month period (May-October 2020), the patient was closely monitored and underwent four hyperimmune plasma collections. Serum SARS-CoV-2 (anti-S + anti-N) IgG and IgM, anti-S1 IgA, and neutralizing titers (NTs) were measured. Anti-SARS-CoV-2 antibody levels steadily decreased. No correlation was found between anti-S/anti-N IgG and IgM levels and viral NT, measured by either a microneutralization test or the surrogate RBD/ACE2-binding inhibition test. Conversely, NTs directly correlated with anti-S1 IgA levels. Hyperimmune donor plasma, administered to five SARS-CoV-2 patients with persistent, severe COVID-19 symptoms, induced short-term clinical and pathological improvement. Reported data suggest that high NTs can persist longer than expected, thus widening hyperimmune plasma source, availability, and potential use. In vitro RBD/ACE2-binding inhibition test is confirmed as a convenient surrogate index for neutralizing activity and patients' follow-up, suitable for clinical settings where biosafety level 3 facilities are not available. IgA levels may correlate with serum neutralizing activity and represent a further independent index for patient evaluation.


Assuntos
Anticorpos Neutralizantes/administração & dosagem , Anticorpos Antivirais/administração & dosagem , COVID-19/terapia , SARS-CoV-2/imunologia , Idoso , Anticorpos Neutralizantes/sangue , Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , Doadores de Sangue , COVID-19/imunologia , COVID-19/virologia , Humanos , Imunização Passiva , Imunoglobulina A/administração & dosagem , Imunoglobulina A/sangue , Imunoglobulina A/imunologia , Masculino , Pessoa de Meia-Idade , Glicoproteína da Espícula de Coronavírus/imunologia , Fatores de Tempo , Resultado do Tratamento , Soroterapia para COVID-19
2.
Blood Transfus ; 10(1): 39-44, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22153690

RESUMO

BACKGROUND: The aim of this study was to evaluate the quality of red blood cell concentrates obtained from donated whole blood, selected for transfusion therapy of thalassaemic patients, by measuring the following parameters: haemoglobin, haematocrit, percentage haemolysis, residual leucocyte count and residual protein content. MATERIALS AND METHODS: Overall 345 red cell concentrates were evaluated, of which 205 had been filtered in-line pre-storage and washed and 140 were buffy coat-depleted and used within 2 days of collection. Of the buffy coat-depleted concentrates, 62 were leucodepleted and 78 washed and leucodepleted post-storage all within 2 days of collection. The off-line filters used for the leucodepletion were gamma-irradiated polyester with a pore size of 200 µm. The washing procedure was automated (Haemonetics ACP 215, Braintree, MA, USA). The haematological parameters were evaluated by a blood cell counter (Coulter, Ramsey, IL, USA) and the white blood cell count by cytofluorimetry (FACScan). RESULTS: Ninety-five percent (194/205) of the red cell concentrates that had been filtered pre-storage and washed, 92% (57/62) of the red cell concentrates that had been leucodepleted post-storage and 94% (73/78) of the those subjected to both treatments had normal values of haemoglobin (>40 g/unit), haematocrit (between 50-70%), percentage haemolysis (<0.8/unit), white cell count (<1×10(6)) and residual protein content (<0.5 g/L). Five percent (11/205) of the red cell concentrates that had been filtered pre-storage and washed, 8% (5/62) of those leucodepleted post-storage after 2 days and 6% (5/78) of those that underwent both procedures had a haemoglobin content <40 g/unit and a haematocrit <50%. CONCLUSIONS: The preparation procedures had been carried out satisfactorily; nevertheless, transfusion therapy with some "low dose" normal units could be less effective and might, therefore, result in greater transfusion requirements in patients receiving such units.


Assuntos
Proteínas Sanguíneas/análise , Eritrócitos/citologia , Hemoglobinas/análise , Leucócitos/citologia , Talassemia beta/terapia , Preservação de Sangue , Transfusão de Eritrócitos , Feminino , Hematócrito , Humanos , Contagem de Leucócitos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA