1.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 2506-2509, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086354

RESUMO

For correct setting and control of imaging during image-guided Magnetic Resonance (MR) procedures (e.g. changing the slice orientation), the radiologist currently depends heavily on the assistants in the control room. The communication between the surgeon and the assistant is difficult due to acoustic noise generated by the MR gradients. The development for a dedicated interventional interaction device is addressed in this work, which includes the development and evaluation of a sterile, MR-compatible capacitive gesture controller. The gesture controller consists of a surgical drape with four capacitive sensors, that are made of conductive fabric. These sensors are based on the principle of electrical capacitance between isolated conductive structures. Measurements of these capacitances are exploited to calculate the distance of a hand to one of the sensors. By comparing the distances of the hand to each sensor, simple swipe gestures can be detected. The sensor unit is connected to a micro-controller, which allows direct and fast processing of the incoming data. To evaluate the prototype, a user study with 25 participants took place. Each user had to perform the four swiping gestures and the hold gesture in a specific order. The gesture controller is capable of registering five different gestures (left-right, right-left, up-down, down-up, hold). A survey of the second prototype showed, that in 92,4% of cases, the correct gesture was registered. Clinical relevance This interaction device allows the practicing physician to manipulate the imaging independently and in a sterile manner, thus enabling a significant improvement in work-flow.


Assuntos
Gestos , Interface Usuário-Computador , Mãos , Humanos , Imageamento por Ressonância Magnética/métodos
2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 5016-5020, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086647

RESUMO

The MRI hybrid ablation system is an approach to use the MR (magnetic resonance) scanner's radiofrequency amplifier itself as power source for ablation. Hereby, an electrode is connected to the MR internal radiofrequency amplifier. An average RF power is provided through a train of short RF pulses, which is sufficient to thermally destroy tissue. However, ablation with too high power values can cause tissue carbonizations, thus impeding the ablation procedure. Therefore, monitoring of the energy and the power absorbed inside the tissue is necessary. For this purpose, a measurement system was designed to measure the energy applied to the tissue when using the concept of an MRI hybrid ablation system. The system consists of a dual-directional coupler, RF-to-RMS sensors, and a microcontroller. The gradient calculation of the measured energy curve provides information about the absorbed RF power in the tissue. Validation measurements of the system were performed and compared with measurements from the MR-internal power measurement system. The energy monitoring system was also tested in an ablation experiment with ex-vivo animal tissue using the MRI hybrid ablation system. The measurements showed that the applied RF power can be monitored in real-time. It has been shown that the mean RF power absorbed in the patient decreased during an ablation procedure due to an occurring impedance mismatch and tissue changes. In further work, the influence of the monitoring system on the quality of the MR images should be investigated. Clinical relevance- This paper demonstrates an energy monitoring system for an RF ablation system, which can be used inside an MR environment.


Assuntos
Ablação por Cateter , Amplificadores Eletrônicos , Animais , Arritmias Cardíacas , Ablação por Cateter/métodos , Eletrodos , Imageamento por Ressonância Magnética/métodos , Ondas de Rádio
3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 1516-1521, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34891573

RESUMO

MR coils are a crucial part in the receiving chain of an MRI. Their characteristics determine the signal-to-noise-ratio (SNR) as well as the quality of the illumination of the volume-of-interest (VOI), which is significantly reduced as the circumference of the conductor is comparable in size to the wavelength.A well-known countermeasure to this is the use of distributed capacitors on the circumference of conductor loops. Although this measure is mentioned in numerous works, there is no systematic framework to correctly determine the values of these capacitors. In this work a systematic framework for the analysis of distributed capacitors on conductor loops is established. This is achieved by a four-pole representation of the circular loop, which allows for a eigen-mode analysis to determine the correct values.Based on the results, an experimental method for determining the values is derived and validated in workbench measurements. This provides, for the first time, an easy-to-use method for determining the correct values of distributed capacitors.


Assuntos
Imageamento por Ressonância Magnética , Projetos de Pesquisa , Desenho de Equipamento , Imagens de Fantasmas , Razão Sinal-Ruído
4.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 1522-1526, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34891574

RESUMO

In this work implementing MR receive coils from overlapping traces is investigated. Such a configuration is known from Microstrip transmission line (MTL) coils, which are basically used in Magnetic resonance - ultra high field (MR-UHF) imaging as TX-RX volume coils. Applications at lower field strengths are less common, because the required electrical length is more difficult to satisfy as the frequency decreases. Overlapping traces are already known for lower field strengths like 1.5T or 3T. Such configurations provide the ability of reducing the number of lumped on such a coil becoming more flexible. To investigate such a flexible coil the overlap is extended to much larger degree and it will be shown that this setup can be modeled as classical transmission line. An analytical model is developed and verified with simulations providing accurate calculations of the input impedance. This allows a reliable derivation of its parameters, which simplifies implementation of such coils.


Assuntos
Campos Magnéticos , Imageamento por Ressonância Magnética , Desenho de Equipamento , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas
5.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 480-483, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34891337

RESUMO

During minimally invasive and image-guided procedures, vital parameters have to be recorded for patient safety. In the Magnetic Resonance Tomograph (MRT) environment the Magneto Hydrodynamic (MHD) effect emerges, under the high magnetic field strength in the signal recording of an Electrocardiography (ECG) system. To allow the investigation of this effect, newly developed wireless ECG and Impedance cardiography (ICG) devices using a network time protocol for accurate synchronization of the collected data will be presented. The developed ICG and tetrapolar electrodes were designed to comply with the IEC 60601-1 standard. One subject was instructed to alternate phases of end-inspiration breath hold with the regular breathing cycle and concurrent synchronized ECG and ICG were collected.


Assuntos
Cardiografia de Impedância , Eletrocardiografia , Eletrodos , Humanos , Imageamento por Ressonância Magnética , Respiração
6.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 3382-3386, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34891965

RESUMO

RF absorption in patients undergoing MRI procedures poses a major safety risk due to resulting heating in the tissue. In order to stay below permitted temperature limits the SAR has to be quantified and limited. Based on the model of an infant inside a birdcage coil we have investigated the SAR distribution in the body at 1.5T. Thermal simulations could thus be performed to establish a relationship between the limitations of SAR and temperature. Results show a thermal hotspot in the neck region caused by high local absorption. The temperature limits in this local area were exceeded after 7min of excitation within regulatory SAR limits. For a long-term exposure critical organs in the body's core also undergo thermal stress beyond limitations. This indicates the need for constraints in regard to long MR procedures to consider the temporal aspect of heating.Clinical Relevance-This work establishes a relationship between SAR and temperature in infants undergoing MRI and shows potential risks of long-term procedures due to induced thermal stress.


Assuntos
Calefação , Ondas de Rádio , Simulação por Computador , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Imagens de Fantasmas
7.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 1439-1443, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34891556

RESUMO

External therapy devices in the shielded room of a magnetic resonance tomograph (MRT) can cause radio frequency (RF) imaging artifacts, which renders the image useless for diagnosis or guiding the procedure. At present, there is no standard procedure to evaluate their conformity with MR imaging.The aim of this paper is to adapt an already existing procedure from the electromagnetic compatibility (EMC), the reverberation chamber (RVC), to evaluate interferences in the magnetic resonance (MR) environment. For this purpose, a test rig was developed which is adapted to the special conditions of the MRI environment. In addition, the suitability of this procedure will be demonstrated in first measurements. The results show that the method can trace and evaluate RF interference of therapy devices. Moreover, the shielded cabin of an MRI system is suitable to perform such measurements.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio
8.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 1457-1461, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34891560

RESUMO

Irreversible electroporation (IRE) is a non-thermal tumor ablation method where strong electrical fields between at least two electrodes are used and can be seen as an alternative to thermal ablation techniques. The therapy outcome directly dependents on the position of the electrodes. Real-time monitoring of the IRE by magnetic resonance imaging (MRI) would allow to detect unwanted electrode displacement and to apply visualization methods for the ablation area. This requires that the IRE generator does not significantly interfere with the MRI. Currently, there is no IRE generator available designed for MRI-guided IRE.This paper presents an IRE system specifically developed for use in an MRI environment. The system is initially tested with a standard IRE sequence and then the interference between a clinical 3 T MRI device and the IRE system is investigated using a noise measurement and the signal-to-noise ratio (SNR) of images acquired with a gradient echo (GRE) sequence. The results show, that although the SNR of the images decrease by maximal 36 % when the IRE system is switched on, image quality does not visibly degrade. Hence, MRI-guided IRE is feasible with the proposed system.Clinical relevance- This paper demonstrates the possibility of MRI-guided IRE with only minor image degradation when the IRE system is used in parallel with MRI imaging.


Assuntos
Técnicas de Ablação , Eletroporação , Eletrodos , Imageamento por Ressonância Magnética
9.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 1419-1422, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34891551

RESUMO

Magnetic Resonance Imaging (MRI) guided Microwave Ablation (MWA) allows for real-time therapy monitoring with MRI-thermometry. The MWA generator emits Radio Frequency (RF) interference, which can limit the accuracy of therapy monitoring. The image quality is enhanced by Floating Cable Traps (FCTs) that are used to attenuate common mode currents on supply lines between a MWA generator, and its ablation applicator. The effect of an FCT on the Signal to Noise Ratio (SNR), and changes in the MRI spectrum are discussed in this paper. The application of FCT can bring significant improvements in both, the MRI spectrum and the SNR.Floating Cable Traps are user-friendly. FCT enable coaxial cables to reduce interferences emitted in MRI guided interventions. It is used to selectively attenuate frequencies in the MRI's range. This can increase the image's Signal to Noise Ratio.


Assuntos
Micro-Ondas , Termometria , Imageamento por Ressonância Magnética , Impressão Tridimensional , Razão Sinal-Ruído
10.
Int J Comput Assist Radiol Surg ; 15(3): 545-553, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31520326

RESUMO

PURPOSE: MRI-guided interventions allow minimally invasive, radiation-free treatment but rely on real-time image data and free slice positioning. Interventional interaction with the data and the MRI scanner is cumbersome due to the diagnostic focus of current systems, confined space and sterile conditions. METHODS: We present a touchless, hand-gesture-based interaction concept to control functions of the MRI scanner typically used during MRI-guided interventions. The system consists of a hand gesture sensor customised for MRI compatibility and a specialised UI that was developed based on clinical needs. A user study with 10 radiologists was performed to compare the gesture interaction concept and its components to task delegation-the prevalent method in clinical practice. RESULTS: Both methods performed comparably in terms of task duration and subjective workload. Subjective performance with gesture input was perceived as worse compared to task delegation, but was rated acceptable in terms of usability while task delegation was not. CONCLUSION: This work contributes by (1) providing access to relevant functions on an MRI scanner during percutaneous interventions in a (2) suitable way for sterile human-computer interaction. The introduced concept removes indirect interaction with the scanner via an assistant, which leads to comparable subjective workload and task completion times while showing higher perceived usability.


Assuntos
Gestos , Imageamento por Ressonância Magnética/métodos , Interface Usuário-Computador , Humanos
11.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 2508-2512, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31946407

RESUMO

The need of external ablation generators complicates the setup of magnetic resonance (MR) guided interventions, e. g. due to inserting devices with ferrite components into the MR room or because of image distortions due to RF interferences. By using the power provided from the MR internal power amplifier, it is possible to avoid external ablation generators. Using imaging sequences with a high duty cycle, a sufficient mean power value can be generated to destroy tissue. In this paper, it has been shown that it is possible to destroy tissue with such an ablation MRI hybrid system. Simulations were done to calculate the specific absorption rate (SAR) generated by an ablation electrode at the Larmor frequency for a 3 T MR device. The SAR values were then compared with ablation experiments performed inside an MR device with protein phantoms.


Assuntos
Técnicas de Ablação/instrumentação , Imageamento por Ressonância Magnética , Imagens de Fantasmas
12.
Biomed Tech (Berl) ; 64(4): 373-382, 2019 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-30205636

RESUMO

Purpose To analyze the interference between a wireless high definition multimedia interface (WHDMI) and magnetic resonance imaging (MRI) image quality at 1.5T, 3T and 7T. Materials and methods A wireless video transmission system (WVTS) consisting of a WHDMI and a projector was used to transmit and display a video stream into the magnet room. MR image quality was analyzed at 1.5T, 3T and 7T. Signal-to-noise-ratio (SNR¯) $(\overline {{\rm{SNR}}} )$ and radio frequency (RF)-noise spectrum were measured at three transmitter positions (A: inside the cabin, B: in front of the waveguide and C: in the control room). WVTS system functionality tests included measurements of reliability, delay and image quality. Results With the WVTS mean SNR¯ $\overline {{\rm{SNR}}} $ values significantly decreased in comparison to the reference for all positions and fieldstrenghts, while the spectra's baseline is elevated at 1.5T and 3T. Peaks related to continuous wave interferences are apparent at all field strenghts. For WHDMI alone mean SNR¯ $\overline {{\rm{SNR}}} $ values were stable without significant differences to the reference. No elevation of the spectra's baseline could be observed. Functionality measurements confirmed high connection reliability with stable image quality and no delays for all field strengths. Conclusion We conclude that wireless transmission of video streams into the MRI magnet room is feasible at all field strengths without hampering image quality.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Humanos , Imãs , Ondas de Rádio , Reprodutibilidade dos Testes , Razão Sinal-Ruído