Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Am J Ther ; 30(5): e426-e432, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37713686

RESUMO

ABSTRACT: Hyperkalemic cardiac arrest diagnosis can be elusive and management difficult as the cardiac rhythm restoration is often not achieved until the potassium level decreases to a relatively normal level for the patient who suffers the arrest. Current treatment modalities can take hours to achieve this goal. We describe two patients who survived a witnessed hyperkalemic cardiac arrest after being managed with conventional advanced cardiac life support and unconventionally high doses of intravenous insulin.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca , Hiperpotassemia , Humanos , Insulina/uso terapêutico , Parada Cardíaca/etiologia , Parada Cardíaca/terapia , Hiperpotassemia/diagnóstico , Hiperpotassemia/tratamento farmacológico , Insulina Regular Humana
2.
J Anaesthesiol Clin Pharmacol ; 37(4): 537-541, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35340957

RESUMO

Background and Aims: to quantify the scalp-cortex distance and determine its variation among patients. We hypothesized that in a significant number of patients, this distance is greater than the maximum penetration depth of current cerebral oximeters. Material and Methods: A retrospective anatomic study using transverse head CT images selected randomly from 102 patients over the age of 18 years without brain swelling, intracranial mass effect, or brain hemorrhage. Scalp-cortex distances were determined at two separate locations along the craniocaudal axis; most cephalad to the frontal sinus (I0) and also 2 cm cephalad to that location (I2). Multiple measurements were obtained bilaterally at 1, 3, 5, 7, and 9 cm from midline. Results: The average scalp-cortex distance was 14.3 mm and 15 mm at I0 and I2 respectively. Distances varied more in I2 than in I0; from the measurements, 12.8% vs. 6.8% were over 20 mm, 4.4% vs. 2.2% over 25 mm, 1.1% vs. 0.6% over 35 mm and 0.6% vs. none over 40 mm at I2 and I0, respectively. 1.5% of the measurements at I2 were over 30 mm. Conclusion: Cerebral oximetry manufacturers all claim to measure cerebral tissue up to a depth of 20-25 mm; 20 mm with the EQUANOX and INVOS compared with 25 mm with the FORE-SIGHT. Scalp-cortex distance is within 25 mm in more than 95% of patients. However, even with the probe placed as per the manufacturer's recommendations, in a small but significant subset of patients, this distance is greater than the maximum penetration depth of current cerebral oximeters and hence may not reflect actual brain tissue oxygen saturation.

3.
Turk J Anaesthesiol Reanim ; 50(3): 232-234, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35801332

RESUMO

An otherwise healthy man in his 40s recently diagnosed with esophageal adenocarcinoma sustained an air embolism during the insertion of a mediport under mild sedation that was noted while using pulse fluoroscopy to ensure good visibility of adequate placement of the catheter tip. Pulse fluoroscopy allowed the early detection of a potentially catastrophic situation caused by air in the right heart and main pulmonary artery, thus allowing prompt correction of the mistake that had allowed the air embolism to occur. Pulse fluoroscopy eliminates or greatly reduces the blurred vision of highly mobile objects and enhances the view of low contrast objects thus enhancing imaging quality.

6.
Technology (Singap World Sci) ; 7(3-4): 98-107, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32292800

RESUMO

Obtaining venous access for blood sampling or intravenous (IV) fluid delivery is an essential first step in patient care. However, success rates rely heavily on clinician experience and patient physiology. Difficulties in obtaining venous access result in missed sticks and injury to patients, and typically require alternative access pathways and additional personnel that lengthen procedure times, thereby creating unnecessary costs to healthcare facilities. Here, we present the first-in-human assessment of an automated robotic venipuncture device designed to safely perform blood draws on peripheral forearm veins. The device combines ultrasound imaging and miniaturized robotics to identify suitable vessels for cannulation and robotically guide an attached needle toward the lumen center. The device demonstrated results comparable to or exceeding that of clinical standards, with a success rate of 87% on all participants (n = 31), a 97% success rate on nondifficult venous access participants (n = 25), and an average procedure time of 93 ± 30 s (n = 31). In the future, this device can be extended to other areas of vascular access such as IV catheterization, central venous access, dialysis, and arterial line placement.

7.
Exp Ther Med ; 12(3): 1599-1603, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27588081

RESUMO

In the present study, the availability of smoking cessation programs (SCP) was surveyed in the same randomly selected USA hospitals in 2000 and 2012. A total of 102 USA hospitals were randomly selected for this survey. Each hospital website was searched for the topic of smoking cessation. In the second phase of the survey, the main switchboard number of each hospital was anonymously telephoned and the 'stop smoking clinic' was requested. The phone survey results showed that the percentage of hospital switchboard calls that were connected to a SCP remained identical at 47% in 2000 and 2012. The results for the internet availability of SCP on hospital websites improved from 30% in 2000 to 47% in 2012. There were more hospitals that added additional SCP information (27%) compared with those that removed SCP information (15%) by 2012. Among the 57% of hospitals that showed no change in internet SCP information, 22% remained positive for such information while 35% remained negative. The phone survey of hospitals showed that 47% of USA hospitals were able to connect a caller to a SCP in the years 2000 and 2012. While there was no reduction over the 12 years, there was no increase in the percentage of hospital switchboards that connected to a SCP. Availability of SCP information on hospital web sites improved to a limited extent; increasing from 30% of sites in 2000 to 47% in 2012. Providing SCP on a hospital website is easy and free, for example adding a link to QuitNet or QuitLink. The present study adds to information gathered 12 years earlier, and is unusual in being able to provide follow-up data on the same set of hospitals studied previously.

8.
A A Case Rep ; 5(12): 216-8, 2015 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-26657701

RESUMO

Monitoring of cerebral perfusion by near-infrared spectroscopy estimates regional cerebral oxygen saturation (rSO2). We present a case in which, before clamping the left carotid artery during an endarterectomy, the right and left rSO2 measurements were 72% and 74%, respectively. Within 15 seconds of clamping the external carotid artery, the left rSO2 decreased by 8%, yielding right and left rSO2 measurements of 70% and 66%, respectively. No electroencephalogram changes ensued. The internal carotid artery was clamped 1 minute later, whereas the external carotid remained clamped. No electroencephalogram changes were observed. The rSO2 measurements demonstrate that the value of this cerebral oximetry is not determined solely from internal carotid blood flow and can be significantly affected by the external carotid.


Assuntos
Artéria Carótida Externa , Artéria Carótida Interna , Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas/efeitos adversos , Oximetria/métodos , Oxigênio/sangue , Idoso de 80 Anos ou mais , Isquemia Encefálica/prevenção & controle , Estenose das Carótidas/sangue , Circulação Cerebrovascular , Constrição , Eletroencefalografia , Humanos , Masculino , Monitorização Intraoperatória/métodos
9.
J Invest Surg ; 15(1): 5-14, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-11931495

RESUMO

Pulmonary hypertension is associated with significant morbidity and mortality in adult cardiac surgery patients. Inhaled nitric oxide is known to be a selective pulmonary vasodilator in this setting. However, it is not known which cardiac surgery patients benefit most from nitric oxide therapy. This study sought to prospectively determine whether a patient's baseline pulmonary vascular resistance could be used to predict responsiveness to inhaled nitric oxide therapy. Subjects were 30 consecutive cardiac surgery patients with pulmonary hypertension immediately prior to induction of anesthesia. There were 2 study groups: Group 1 (n = 15) had an initial pulmonary vascular resistance between 125 and 300 dyn-s/cm5, while group 2 (n = 15) had an initial pulmonary vascular resistance of greater than 300 dyn-s/cm5. Both groups were empirically treated with inhaled nitric oxide (30 ppm) upon separation from bypass. The conduct of anesthesia, surgery, and cardiopulmonary bypass were controlled. A therapeutic algorithm dictated the use of vasoactive substances for all patients. Heart rate, mean arterial pressure, pulmonary vascular resistance, peripheral vascular resistance, cardiac index, and right ventricular ejection fraction were monitored throughout the operative experience. Patients with a higher initial pulmonary vascular resistance had a significantly greater percent reduction in pulmonary vascular resistance after the initiation of nitric oxide therapy. This study suggests that pulmonary vascular resistance is more dramatically affected by inhaled nitric oxide in cardiac surgery patients with a greater degree of pulmonary hypertension.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Óxido Nítrico/farmacologia , Circulação Pulmonar/efeitos dos fármacos , Resistência Vascular/efeitos dos fármacos , Administração por Inalação , Idoso , Pressão Sanguínea/efeitos dos fármacos , Ponte Cardiopulmonar , Frequência Cardíaca/efeitos dos fármacos , Humanos , Hipertensão Pulmonar/complicações , Óxido Nítrico/administração & dosagem , Estudos Prospectivos , Volume Sistólico/efeitos dos fármacos
10.
Innovations (Phila) ; 7(3): 204-7, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22885463

RESUMO

OBJECTIVE: To perform minimally invasive cardiac surgery through the smallest possible wound and with the least number of incisions in the heart or aorta, the necessary cannulations to undergo cardiopulmonary bypass must be done through peripheral vessels. A difficult skill to learn for the cardiac anesthesiologist is how to safely and efficiently position the coronary sinus catheter (Endoplege; Edwards Lifesciences LLC, Irvine, CA USA) required for retrograde cardioplegia administration. METHODS: In patients in whom a Swan-Ganz catheter was inserted as part of the operative management strategy for non-minimally invasive heart surgery, we have been using it as a training tool to learn how to visualize and manipulate right-sided catheters under transesophageal echocardiography. We developed this teaching technique to help hone some of the necessary skills needed to place the Endoplege catheter for minimally invasive cardiac surgery. Manipulation was done with the goal of visualizing the catheter and guiding it into the coronary sinus. For a 4-month period, anesthesia records were retrospectively reviewed. RESULTS: Fifteen patients, for a total of 19 catheter manipulations, were found in whom we had documented the use of the Swan-Ganz catheter and details about the insertion as a training tool. The coronary sinus and the catheter were visualized 100% of the time. The Swan-Ganz catheter was successfully inserted into the coronary sinus in 17 of 19 catheter manipulations. CONCLUSIONS: The Swan-Ganz catheter can be used as a training tool to develop some of the necessary skills to place catheters into the coronary sinus with transesophageal echocardiography guidance.


Assuntos
Anestesiologia/educação , Procedimentos Cirúrgicos Cardíacos/educação , Cateteres de Demora , Procedimentos Cirúrgicos Minimamente Invasivos/educação , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Cardíacos/métodos , Ecocardiografia Transesofagiana , Educação Médica Continuada , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
11.
Innovations (Phila) ; 7(1): 62-4, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22576038

RESUMO

Coronary sinus cannulation for retrograde cardioplegia administration during cardiac surgery is common practice. Several of the cannulas that are placed by the cardiac surgeon on open procedures are now placed by the cardiac anesthesiologist during minimally invasive cardiac surgery, including the coronary sinus catheter. The understanding of the cardiac venous anatomy is very important during coronary sinus catheter placement. We present a case where a percutaneously placed coronary sinus catheter was inadvertently placed into the middle cardiac vein but detected with the use of fluoroscopy.


Assuntos
Cateterismo Cardíaco/métodos , Seio Coronário/cirurgia , Parada Cardíaca Induzida , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Idoso , Feminino , Humanos
12.
Innovations (Phila) ; 6(4): 253-6, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22437984

RESUMO

OBJECTIVE: The placement of epicardial pacing wires before weaning from bypass during port-access heart surgery can be difficult or impossible. Sometimes, it is necessary to pacing the patient to wean from bypass, and it is problematic to exchange the Edwards pulmonary vent (EndoVent) for a pace catheter under the drapes. Our objective was to devise an effective means of pacing the patient using the pulmonary vent catheter. METHODS: All patients having aortic valve minimally invasive port-access surgery have a pacing wire deployed through the Edwards EndoVent catheter. We did a retrospective chart analysis of these cases. RESULTS: After reviewing the anesthesia records, we determined that we were able to reliably convert the pulmonary vent catheter, which is beneficial for the surgery, into a pacing catheter before weaning from bypass 100% of the time. The mean pacing threshold current was 1.60 mA with the wire in the right ventricular apex. CONCLUSIONS: We found that in all 25 patients we were able to rapidly convert the vent catheter into a reliable pacing catheter without any complications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA