1.
Eur J Vasc Endovasc Surg ; 67(5): 756-764, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38154499

RESUMO

OBJECTIVE: Late rupture after endovascular aortic aneurysm repair (EVAR) for an abdominal aortic aneurysm (AAA) is an increasing complication associated with a high mortality rate. This study aimed to analyse the causes and outcomes in patients with AAA rupture after EVAR. METHODS: A multi-institutional Greek study of late ruptures after EVAR between 2008 - 2022 was performed. Primary outcomes were intra-operative and in hospital death. RESULTS: A total of 70 patients presented with late rupture after EVAR (proportion of ruptured EVARs among all EVARs, 0.6%; 69 males; mean age 77.2 ± 6.7 years). The mean time interval between EVAR and late rupture was 72.3 months (range 6 - 180 months). In all cases the cause of rupture was the presence of an endoleak (type I, 73%) with sac enlargement. Moreover, 34% of subjects with rupture after EVAR had been lost to follow up and 32% underwent a secondary intervention. Additionally, 57 patients (81%) were treated by conversion to open surgical repair (COSR) and the remainder by endovascular correction of endoleak (ECE). Eleven intra-operative deaths (16%) were recorded. The overall in hospital mortality rate was 41% (23% ECE vs. 46% COSR; p = .21). Of the patients who presented as initially haemodynamically stable, 23% died during hospitalisation, while the respective mortality rate for patients who presented as unstable was 78% (odds ratio [OR] 11.8, 95% confidence interval [CI] 3.6 - 39.1; p < .001). Multivariable logistic regression analysis revealed that severity of haemodynamic shock was the most significant risk factor for intra-operative (OR 7.15, 95% CI 1.58 - 32.40; p = .010) and in hospital death (OR 9.53, 95% CI 2.79 - 32.58; p < .001). CONCLUSION: These data underline the devastating prognosis of late rupture after EVAR. Haemodynamic status at presentation was an important predictive factor for death both in the ECE and COSR groups. Rigorous follow up and prompt evaluation of an unstable patient in case of rupture after EVAR is recommended.


Assuntos
Aneurisma da Aorta Abdominal , Ruptura Aórtica , Implante de Prótese Vascular , Endoleak , Procedimentos Endovasculares , Mortalidade Hospitalar , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/mortalidade , Masculino , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Idoso , Feminino , Grécia/epidemiologia , Ruptura Aórtica/cirurgia , Ruptura Aórtica/mortalidade , Ruptura Aórtica/etiologia , Idoso de 80 Anos ou mais , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Fatores de Risco , Fatores de Tempo , Endoleak/etiologia , Endoleak/cirurgia , Endoleak/mortalidade , Resultado do Tratamento , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA