Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
Sensors (Basel) ; 21(13)2021 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-34209748

RESUMO

Cryosurgery is a technique of growing popularity involving tissue ablation under controlled freezing. Technological advancement of devices along with surgical technique improvements have turned cryosurgery from an experimental to an established option for treating several diseases. However, cryosurgery is still limited by inaccurate planning based primarily on 2D visualization of the patient's preoperative images. Several works have been aimed at modelling cryoablation through heat transfer simulations; however, most software applications do not meet some key requirements for clinical routine use, such as high computational speed and user-friendliness. This work aims to develop an intuitive platform for anatomical understanding and pre-operative planning by integrating the information content of radiological images and cryoprobe specifications either in a 3D virtual environment (desktop application) or in a hybrid simulator, which exploits the potential of the 3D printing and augmented reality functionalities of Microsoft HoloLens. The proposed platform was preliminarily validated for the retrospective planning/simulation of two surgical cases. Results suggest that the platform is easy and quick to learn and could be used in clinical practice to improve anatomical understanding, to make surgical planning easier than the traditional method, and to strengthen the memorization of surgical planning.


Assuntos
Realidade Aumentada , Criocirurgia , Simulação por Computador , Humanos , Estudos Retrospectivos , Software
2.
Surg Technol Int ; 39: 369-374, 2021 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-34647314

RESUMO

BACKGROUND AND AIM OF THE STUDY: Anterior cruciate ligament (ACL) tears are among the most common articular injuries in sports and can be responsible for knee instability and reduced articular performance. Treatment can be either conservative or operative, and ligament reconstruction may be carried out using biological autologous grafts or synthetic materials. Several studies have sought to evaluate and compare functional results in treated patients. However, there is still very limited information available on long-term follow-up and clinical outcomes are generally evaluated only using subjective scores. In this study, we assessed long-term functional and biomechanical results in patients treated with biologic and synthetic ligaments using objective measures. MATERIALS AND METHODS: Patients were divided according to whether ACL reconstruction was biologic or synthetic. The Tegner activity scale was used before and after surgery. Post-operative subjective scores such as the IKDC Questionnaire and the Tegner-Lysholm score were also recorded. The Y Balance Test was used to assess global stability and mobility of the lower limb. Kinematic Rapid Assessment (KiRA) was used to evidence and estimate ligamentous laxity during the Pivot Shift and Lachman tests. RESULTS: Clinical subjective patient and operator-dependent scores as well as objective biomechanical findings were similar and comparable in patients treated with biologic and synthetic reconstructions after more than 10 years of use. CONCLUSIONS: Both synthetic and biological tendon grafts may represent good reconstructive approaches to treat torn ACLs, and remain effective even for a long period of time if implanted in suitable target patients.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Lesões do Ligamento Cruzado Anterior/epidemiologia , Lesões do Ligamento Cruzado Anterior/cirurgia , Seguimentos , Humanos , Articulação do Joelho/cirurgia , Tendões/cirurgia , Resultado do Tratamento
3.
Surg Technol Int ; 36: 341-346, 2020 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-32190898

RESUMO

En bloc scapulectomy with covering muscles was historically considered the only procedure available for surgical treatment of bone and soft tissue tumors of the scapula. When possible, reconstruction with scapular allograft is the gold standard, and gives satisfactory functional, cosmetic, and oncological outcomes. While good results have recently been reported with 3D-printed prostheses for reconstruction of bone loss, there is little information available in the medical literature regarding scapula reconstruction with a 3D-printed prosthesis. Between 2016 and 2018, we performed four scapular resections (two total and two involving the superior 1/3) followed by reconstruction with a 3D-printed prosthesis made of a porous titanium alloy (Ti-6Al-4V, diameter between 100 and 400 mm), using computer-aided design (CAD) and patient-specific implants (PSI) with previously acquired CT-MR fusion images. At 2 years follow-up, the patients with partial scapulectomy had an MSTS score of 76%, no local or systemic recurrence, good clinical results and no pain. At 1 year 6 months follow-up, the patients with total scapulectomy had an MSTS score of 46%, no local or systemic recurrence, fair clinical results and no pain. Thus, custom-made 3D-printed prostheses appear to be valuable in orthopedic surgery. However, a larger cohort and longer-term analysis are needed to evaluate the scapular 3D-printed prosthesis as a reliable reconstruction technique.


Assuntos
Procedimentos Ortopédicos , Escápula , Humanos , Impressão Tridimensional , Próteses e Implantes , Desenho de Prótese , Implantação de Prótese
4.
Surg Technol Int ; 30: 458-461, 2017 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-28182823

RESUMO

Currently, the gold standard to repair large nerve defects is the autologous nerve graft. These solutions offer a mechanical support, adhesion substrates, and, with Schwann cells (SC), a source of neurotropic factors for axonal growth. The technical limits are the donor side damage, multiple surgical accesses, and the unavailability of large amounts of grafts. In recent years, several researchers focused their attention on the interaction between cells (nervous and glial) and physic-chemical cues that arise from the extracellular milieu. Nanotechnologies produce surfaces that mimic the topographical signals (physical stimuli) that arise from enterprise content management (ECM) to modulate the forces acting during axonal elongation. The use of magnetic nanoparticles (MNPs) seems to be able to guide and to boost the nerve regeneration. Both research areas could be improved through surfaces functionalization by biological molecules (proteins/peptides, growth factors, etc.). In the future, the aim will be to help recovery after peripheral nerve lesion by producing a tridimensional structured conduit, then repeat the ECM architecture and take advantage of MNPs internalized by cells and guide them through tension forces by external magnetic fields to stimulate and direct axon growing. The aims of this review were to evaluate the findings of studies that used physical stimuli (nanoscaffold surfaces and MNPs) used for peripheral nerve regeneration support. The future trends in the field of peripheral nerve regeneration continue to produce a wide variety of new techniques to improve the opportunity for advances to treat peripheral nerve injuries.


Assuntos
Nanopartículas de Magnetita , Regeneração Nervosa , Nervos Periféricos , Alicerces Teciduais , Animais , Células Cultivadas , Humanos , Traumatismos dos Nervos Periféricos/fisiopatologia , Traumatismos dos Nervos Periféricos/cirurgia , Nervos Periféricos/fisiologia , Nervos Periféricos/cirurgia , Células de Schwann/citologia
5.
Surg Technol Int ; 30: 346-351, 2017 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-28277592

RESUMO

INTRODUCTION: Total hip arthroplasty is one of the most performed procedures in orthopaedic surgery. Implantation of a prosthesis determines changes in the distribution of loads on the host bone, and this phenomenon, known as stress shielding, is related to the biomechanical characteristics of the implant. Usually stress shielding involves the proximal portion of the femur by reducing the mechanical strength and ability to withstand the transmitted loads. The aim of our study is to demonstrate how the use of a short hip stem reduces the stress shielding phenomenon to the proximal femur. MATERIALS AND METHODS: The study analyzed 20 patients undergoing hip prosthesis surgery with a short stem (Metha<, B. Braun Medical, Inc., Bethlehem, Pennsylvania) at the Ist Orthopaedic Division of Pisa University (between December 2008 and January 2010). Each patient was subjected to analysis of periprosthetic bone mineral density by a bone densitometry (dual emission X-ray absorptiometry [DEXA] with the metal removal software) at 0, 6, 12, 18, 24, and 36 months, following a protocol based on the evaluation of the changes of bone density in the seven Gruen zones. RESULTS: We recorded minimal changes in bone mineral density (BMD) at the level of the greater trochanter (-1.44%) and at the level of the calcar (-3.7%). BMD increased significantly after four years at the level of the lateral distal regions (R2 +9.6% - R3 + 12.4%) and at the level of the distal medial regions (R5 + 8.2% - R6 + 13.1%). We compared the results obtained with the literature data at 12 and 24 months with the same stem (Metha<). At 12 months follow up, we did not see a significant difference between our data and the data published in the literature. However, after 48 months of follow-up, we recorded significant differences in the curves of periprosthetic bone reabsorption at the level of the greater trochanter (Zone 1) and at the level of the calcar (Zone 7). DISCUSSION: The data obtained from our study are in agreement with other studies in the literature, which demonstrates how the use of short stems preserves the metaphyseal bone stock at the level of the proximal femur, reducing the stress shielding phenomenon. From our data, obtained at 24 months and confirmed at 36, stress shielding seems to minimally occur at the level of the calcar. At the level of the great trochanter, we saw a good load distribution that maintained the baseline BMD; these data are in opposition to the literature data that showed a high increase of BMD at the level of the calcar (+12.9%) and a decrease at the level of the great trochanter. From the analysis of the radiographic images of our cases, and of the cases published with the same stem, these differences in load transfer encountered between the great trochanter and the calcar seems to be related to the level of the femoral neck osteotomy and the consequent stem position (varus/valgus). CONCLUSION: We conclude that the amount of periprostetic bone reabsorption around the Metha< stem seems to be strictly related to the surgical technique and the final implant position.


Assuntos
Artroplastia de Quadril , Remodelação Óssea/fisiologia , Prótese de Quadril/estatística & dados numéricos , Adulto , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/estatística & dados numéricos , Densidade Óssea , Feminino , Fêmur/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese
6.
Clin Cases Miner Bone Metab ; 13(3): 221-227, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28228786

RESUMO

PURPOSE: Total hip arthroplasty could fail due to many factors and one of the most common is the aseptic loosening. In order to achieve an effective osseointegration and reduce risk of lossening, the use of cemented implant, contact porous bearing surface and organic coating were developed. Aim of this study was to evaluate clinical and radiological mid-term outcomes of a porous titanium alloy/hydroxyapatite double coating manufactured cementless femoral stem applied with "plasma spray" technique and to demonstrate the possibility to use this stem in different types of femoral canals. METHODS: Between January 2008 and December 2012, 240 consecutive primary total hip arthroplasties (THAs) were performed using a porous titanium alloy/hydroxyapatite double coating manufactured cementless femoral stem. 182 patients were examined: 136 were females (74.7%) and 46 males (25.2%); average age was 72 years old (ranging from 26 to 92 years old). For each patient, Harris Hip Scores (HHS) and Womac Scores were collected. All X-ray images were analyzed in order to demonstrate stem survival rate and subsidence. RESULTS: Harris Hip Score was good or excellent in 85% of the cases (average 90%) and mean WOMAC score was 97.5 (ranging from 73.4 to 100). No cases of early/late infection or periprosthetic fracture were noticed, with an excellent implant survival rate (100%) in a mean period of 40 months (ranging from 24 and 84 months). 5 cases presented acute implant dislocation, 2 due to wrong cup positioning in a dysplastic acetabulum and 3 after ground level fall. Dorr classification of femoral geometry was uses and the results were: 51 type A bone, 53 type B bone and 78 type C bone. Stem subsidence over 2 mm was considered as a risk factor of future implant loosening and was evidenced in 3 female patients with type C of Dorr classification. No radiolucencies signs around the proximally coated portion of stem or proximal reabsorption were visible during the radiographic follow-up. CONCLUSIONS: Concerning the use of porous titanium alloy/hydroxyapatite double coating, this study reported an excellent implant survival rate in a mid-term period with a rate of 1,64% of subsidence in patients with type C of femoral canal but with an optimal HHS and Womac Score results. Regarding this stem, primary stability is guaranteed by trapezoid shape of proximal region and tapering in frontal plane through press-fit technique. Radiological absence of pedestal has been accepted as sign of no excessive stress transmission to distal cortex due to its tapered diaphyseal region. Thanks to the reported data, Authors can consider this double coating a valid choice with an excellent medium-term survival and encouraging subsidence results. Further studies are needed to ensure these results can be replicated.

7.
Surg Technol Int ; 27: 210-4, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26680399

RESUMO

The purpose of this prospective randomized trial was to assess whether an intramedullary nail is superior or not to another one in the treatment of pertrochanteric fractures. Eighty-one patients with a 31-A1 or A2 Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) pertrochanteric fracture were randomly allocated to fixation with either the Gamma® or the ENDOVIS® nail. In order to estimate the functional outcome the Parker-Palmer mobility score, Barthel Index, and EuroQol-5D (EQ-5D) were used. All patients were followed up at 1, 3, 6, and 12 months postoperatively. There was no statistical difference in Parker mobility score between groups. The statistical analysis revealed that there was no significant difference between the two patient groups as far as the operating time, the amount of blood transfused, and the latest functional outcome. Both kinds of intramedullary nails used in our study provide effective methods of treatment for intertrochanteric fractures in elderly patients. Our data showed slightly worse results for the ENDOVIS nail compared with the Gamma nail, but this did not reach a statistical significance.


Assuntos
Pinos Ortopédicos , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas/instrumentação , Fixação Intramedular de Fraturas/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Feminino , Fraturas do Fêmur/epidemiologia , Humanos , Complicações Intraoperatórias , Masculino , Complicações Pós-Operatórias , Estudos Prospectivos
8.
ScientificWorldJournal ; 2014: 148592, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25610894

RESUMO

Acetabular cup loosening is associated with pain, reduced function, and instability of the implant. If such event happens while the femoral implant is in a satisfactory position and is well fixed to the bone, isolated acetabular revision surgery is indicated. The aim of this single-center retrospective study was to evaluate the clinical and radiological results over the medium term (12-month follow-up mean 36, max 60) of isolated acetabular revisions surgery using a porous hemispheric revision shell matched with a cemented all-poly cup and large diameter femoral head (>32). 33 patients were enrolled. We collect any relevant data from the clinical board. Routine clinical and radiographic examinations were performed preoperatively; the postoperative follow-up was made at 1, 3, and 6 months and yearly thereafter. At the last available follow-up, we report satisfactory improvement of functional scores in all the patients; 2 patients (6.1%) showed thigh pain and only 4 hips (12.11%) presented mild groin pain; all the femoral components are well fixed and there were no potential or pending rerevisions. With bias due to the follow-up and to the retrospective design of the study, we report clinical, functional, and radiological satisfactory results.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril , Fêmur/cirurgia , Prótese de Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fêmur/diagnóstico por imagem , Fêmur/patologia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Radiografia , Reoperação , Estudos Retrospectivos
9.
Eur J Orthop Surg Traumatol ; 24(2): 237-42, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23412327

RESUMO

Acromio-clavicular joint (ACJ) injuries represent nearly half of all athletic shoulder injuries. Stability of this joint depends on the integrity of the acromio-clavicular and coracoclavicular ligaments. Although the traumatic acromioclavicular joint separation is a well-known topic, there are different classifications, diagnostic procedures, concepts of intervention, and a great variety of implants. In this paper, we present an overview of the recent literature about this issue and the results of a retrospective non-randomized study with 2 different techniques. At the first Orthopedic Department of University of Pisa, a retrospective study was performed starting from January 2007 to February 2011 in our electronic database. We selected patient treated with two different techniques (tight-rope(®) system and hook plate) by the same senior surgeon with experience in shoulder surgery. The mean Costant score was 90 for the tight-rope(®) system group and 75 for the hook plate group. At the final follow-up, most of the patients had returned to their preinjury level of activity. Two patients had a breakage of the fixating system. The above-mentioned techniques provided satisfactory results with no loss of reduction except in two cases. The use of the hook plate is useful in fracture-dislocation of ACJ, but this requires another surgery to remove it. On the contrary, the use of the tight-rope(®) system does not require a new surgery or use of expensive synthetic graft or a graft harvested from a distant donor site.


Assuntos
Articulação Acromioclavicular/cirurgia , Luxações Articulares/cirurgia , Ligamentos Articulares/cirurgia , Procedimentos Ortopédicos/métodos , Articulação Acromioclavicular/lesões , Adulto , Feminino , Seguimentos , Humanos , Ligamentos Articulares/lesões , Masculino , Pessoa de Meia-Idade , Procedimentos Ortopédicos/instrumentação , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
10.
Eur J Orthop Surg Traumatol ; 24(7): 1249-54, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24062054

RESUMO

We report our initial experience of total knee arthroplasty (TKA) using customized cutting block technology in 30 TKAs from December 2010 to September 2012. Customized blocks were generated for each of the knees using preoperative magnetic resonance imaging of knee and long-leg weight-bearing radiographs. At 30 days, long-leg radiographs were obtained to evaluate the coronal alignment. Twenty-six of the 30 knees had a mechanical axis restored to within 3° of neutral. We conclude that this technology can be safely used in most of the cases of osteoarthritis.


Assuntos
Artroplastia do Joelho/instrumentação , Mau Alinhamento Ósseo/diagnóstico por imagem , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Desenho de Prótese , Idoso , Fenômenos Biomecânicos , Feminino , Fêmur/diagnóstico por imagem , Humanos , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico por imagem , Período Pré-Operatório , Radiografia , Tíbia/diagnóstico por imagem
11.
Clin Cases Miner Bone Metab ; 11(3): 226-31, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25568658

RESUMO

The application of Dual-energy X-ray absorptiometry (DEXA) in orthopaedic surgery gradually has been extended from the study of osteoporosis to different areas of interest like the study of the relation between bone and prosthetic implants. Aim of this review is to analyze changes that occur in periprosthetic bone after the implantation of a total hip arthroplasty (THA) or a total knee arthroplasty (TKA). In THA the pattern of adaptive bone remodeling with different cementless femoral stems varies and it appears to be strictly related to the design and more specifically to where the femoral stem is fixed on bone. Short stems with metaphyseal fixation allow the maintenance of a more physiologic load transfer to the proximal femur decreasing the entity of bone loss. Femoral bone loss after TKA seems to be related to the stress shielding induced by the implants while tibial bone remodeling seems to be related to postoperative changes in knee alignment (varus/valgus) and consequently in tibial load transfer. After both THA and TKA stress shielding seems to be an inevitable phenomenon that occurs mainly in the first year after surgery.

12.
Stem Cell Rev Rep ; 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38914791

RESUMO

The stem cell niche in the bone marrow is a hypoxic environment, where the low oxygen tension preserves the pluripotency of stem cells. We have identified mesangiogenic progenitor cells (MPC) exhibiting angiogenic and mesenchymal differentiation capabilities in vitro. The effect of hypoxia on MPC has not been previously explored. In this study, MPCs were isolated from volunteers' bone marrow and cultured under both normoxic and hypoxic conditions (3% O2). MPCs maintained their characteristic morphology and surface marker expression (CD18 + CD31 + CD90-CD73-) under hypoxia. However, hypoxic conditions led to reduced MPC proliferation in primary cultures and hindered their differentiation into mesenchymal stem cells (MSCs) upon exposure to differentiative medium. First passage MSCs derived from MPC appeared unaffected by hypoxia, exhibiting no discernible differences in proliferative potential or cell cycle. However, hypoxia impeded the subsequent osteogenic differentiation of MSCs, as evidenced by decreased hydroxyapatite deposition. Conversely, hypoxia did not impact the angiogenic differentiation potential of MPCs, as demonstrated by spheroid-based assays revealing comparable angiogenic sprouting and tube-like formation capabilities under both hypoxic and normoxic conditions. These findings indicate that hypoxia preserves the stemness phenotype of MPCs, inhibits their differentiation into MSCs, and hampers their osteogenic maturation while leaving their angiogenic potential unaffected. Our study sheds light on the intricate effects of hypoxia on bone marrow-derived MPCs and their differentiation pathways.

13.
Cureus ; 16(3): e56413, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38638784

RESUMO

INTRODUCTION: Meniscal injuries are a common challenge in orthopedic surgery. For decades, partial or total meniscectomy has been the primary surgical treatment for meniscal tears. In recent years, the increased recognition of menisci's biomechanical importance has progressively shifted the paradigm towards meniscus repair. However, meniscus-sparing surgery remains the treatment of choice for selected lesions in young and active patients, especially for young and active patients. In this study, we evaluated the effectiveness of all-inside sutures in treating meniscus tears in patients over 40. METHODS: In our retrospective evaluation, we evaluated the clinical and functional outcomes of cases over 40 years of age with post-traumatic acute meniscus tears that received meniscus repairs using the all-inside technique. The pre-operative and post-operative functionality of treated patients were assessed using the knee injury and osteoarthritis outcome score (KOOS) score. Major complications were recorded. RESULTS: Twenty-three cases met our inclusion criteria. Eight females and fifteen males with a mean age of 44.9 were included in our study. Their mean follow-up was 35.1 months. Before surgery, our patients' mean KOOS score was 55.4 (18-80). At the patients' latest follow-up, the value had risen to 87.4 (63-100). There was no statistical correlation between patients' age and their functional recovery. No surgical failure was recorded at the latest follow-up. CONCLUSION: The all-inside suture technique can represent a suitable and reliable solution for suturable meniscal tears, even for patients over 40. Preserving the meniscus and restoring patients' functionality allows patients to return to their daily activities and promote their quality of life.

14.
Bioengineering (Basel) ; 11(2)2024 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-38391679

RESUMO

Bone defects are a significant health problem worldwide. Novel treatment approaches in the tissue engineering field rely on the use of biomaterial scaffolds to stimulate and guide the regeneration of damaged tissue that cannot repair or regrow spontaneously. This work aimed at developing and characterizing new piezoelectric scaffolds to provide electric bio-signals naturally present in bone and vascular tissues. Mixing and extrusion were used to obtain nanocomposites made of polyhydroxybutyrate (PHB) as a matrix and barium titanate (BaTiO3) nanoparticles as a filler, at BaTiO3/PHB compositions of 5/95, 10/90, 15/85 and 20/80 (w/w%). The morphological, thermal, mechanical and piezoelectric properties of the nanocomposites were studied. Scanning electron microscopy analysis showed good nanoparticle dispersion within the polymer matrix. Considerable increases in the Young's modulus, compressive strength and the piezoelectric coefficient d31 were observed with increasing BaTiO3 content, with d31 = 37 pm/V in 20/80 (w/w%) BaTiO3/PHB. 3D printing was used to produce porous cubic-shaped scaffolds using a 90° lay-down pattern, with pore size ranging in 0.60-0.77 mm and good mechanical stability. Biodegradation tests conducted for 8 weeks in saline solution at 37 °C showed low mass loss (∼4%) for 3D printed scaffolds. The results obtained in terms of piezoelectric, mechanical and chemical properties of the nanocomposite provide a new promising strategy for vascularized bone tissue engineering.

15.
Surg Technol Int ; 23: 228-34, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23975443

RESUMO

Each year approximately 1 million total hip replacements (THR) are performed worldwide. A percentage of failure due to surgical approach and imprecise implant placement still exists. These result in several serious complications. We propose an approach to plan, to simulate, and to assist prosthesis implantation for difficult cases of THR based on 3-D virtual models, generated by segmenting patients' CT images, 3-D solid models, obtained by rapid prototyping (RP), and virtual procedure simulation. We carried out 8 THR with the aid of 3-D reconstruction and RP. After each procedure a questionnaire was submitted to the surgeon to assess the perceived added value of the technology. In all cases, the surgeon evaluated the 3-D model as useful in order to perform the planning. The clinical results showed a mean increase in the Harris Hip Score of about 42.5 points. The mean time of prototyping was 7.3 hours, (min 3.5 hours, max 9.3 hours). The mean surgery time was 65 minutes (min 50 minutes, max 88 minutes). Our study suggests that meticulous preoperative planning is necessary in front of a great aberration of the joint and in absence of normal anatomical landmarks, CT scan is mandatory, and 3-D reconstruction with solid model is useful.


Assuntos
Artroplastia de Quadril/métodos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Modelos Biológicos , Cuidados Pré-Operatórios/métodos , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Interface Usuário-Computador , Simulação por Computador , Articulação do Quadril/fisiopatologia , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
16.
Int Orthop ; 37(8): 1567-74, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23812539

RESUMO

PURPOSE: The aim of this study was to review patients that underwent ACL reconstruction with the LARS™ ligament in the First Orthopaedic Division of Pisa University during the period between January 2003 and December 2005. METHODS: Twenty-six patients were reviewed with an average follow-up of 95.3 months (7.9 years). The review protocol was articulated in three phases: (1) a subjective evaluation using three grading scales: VAS, KOOS and the Cincinnati knee rating scale, (2) a clinical and objective evaluation, and (3) a biomechanical evaluation of the knee stability. RESULTS: A global positive result was obtained in 92.3 % of the patients (16 optimal results and eight good results), with a fast functional recovery and a high knee stability. A global poor result was reported in two cases. In our series we did not record cases of infection or knee synovitis. We recorded only one case of mechanical graft failure. The results obtained from our study are encouraging and similar to those in the literature. CONCLUSIONS: We conclude that the LARS™ ligament can be considered a suitable option for ACL reconstruction in carefully selected cases, especially for older patients needing a fast functional recovery.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/cirurgia , Ligamentos/cirurgia , Procedimentos Ortopédicos/métodos , Adulto , Reconstrução do Ligamento Cruzado Anterior/efeitos adversos , Fenômenos Biomecânicos/fisiologia , Feminino , Seguimentos , Humanos , Incidência , Instabilidade Articular/epidemiologia , Instabilidade Articular/fisiopatologia , Articulação do Joelho/fisiologia , Articulação do Joelho/cirurgia , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Procedimentos Ortopédicos/efeitos adversos , Próteses e Implantes , Amplitude de Movimento Articular/fisiologia , Recuperação de Função Fisiológica/fisiologia , Estudos Retrospectivos , Resultado do Tratamento
17.
Bioengineering (Basel) ; 10(12)2023 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-38135936

RESUMO

Pedicle screw fixation (PSF) demands rigorous training to mitigate the risk of severe neurovascular complications arising from screw misplacement. This paper introduces a patient-specific phantom designed for PSF training, extending a portion of the learning process beyond the confines of the surgical room. Six phantoms of the thoracolumbar region were fabricated from radiological datasets, combining 3D printing and casting techniques. The phantoms were employed in three training sessions by a fifth-year resident who performed full training on all six phantoms; he/she placed a total of 57 pedicle screws. Analysis of the learning curve, focusing on time per screw and positioning accuracy, revealed attainment of an asymptotic performance level (around 3 min per screw) after 40 screws. The phantom's efficacy was evaluated by three experts and six residents, each inserting a minimum of four screws. Initial assessments confirmed face, content, and construct validity, affirming the patient-specific phantoms as a valuable training resource. These proposed phantoms exhibit great promise as an essential tool in surgical training as they exhibited a demonstrable learning effect on the PSF technique. This study lays the foundation for further exploration and underscores the potential impact of these patient-specific phantoms on the future of spinal surgical education.

18.
Acta Biomed ; 94(1): e2023013, 2023 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-36786271

RESUMO

BACKGROUND AND AIM: Femoral neck fractures are among the most frequent in mankind. Screw fixation is considered a suitable approach specially for undisplaced or slightly displaced fractures that occur to young patients. We conducted our study in order to evaluate both functional outcomes and complication rates of patients who received this treatment in our institution. A particular focus was given to the aseptic necrosis of the head, trying to identify if anamnestic, clinical or radiological data could play a significant role as prognostic factors. METHODS: For each case who was treated with screw fixation due to a femoral neck fracture, we recorded data regarding, among the others, BMI and whether they used tobacco products or corticosteroids on a regular basis. Necrosis of the femoral head and mechanical complications were recorded. Functional outcome was evaluated using the Harris Hip Score.      Results: 74 cases were included in our study. The mean Harris Hip score was 89.5. Aseptic necrosis of the femoral head occurred in 9 cases (12.2%). Regular use of tobacco was associated with a higher risk to develop necrosis (p=0.007). The Body Mass Index was significantly higher in cases who had necrosis compared to the rest of our population (p=0.043) and was inversely proportional to the post-operative Harris hip score (p=0.001). CONCLUSIONS: While considering screw fixation to treat cases with femoral neck fractures, patient's weight and use of tobacco should be considered as prognostic factors.  (www.actabiomedica.it).


Assuntos
Fraturas do Colo Femoral , Necrose da Cabeça do Fêmur , Cirurgiões , Humanos , Necrose da Cabeça do Fêmur/etiologia , Necrose da Cabeça do Fêmur/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Fraturas do Colo Femoral/cirurgia , Parafusos Ósseos/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos
19.
Adv Orthop ; 2023: 1868943, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36938102

RESUMO

Background: Knee osteoarthritis is a common disease with increasing incidence and prevalence in western countries. It can cause severe pain and functional limitations, thereby representing a threat for patients' quality of life and a burden for national health systems. Intra-articular injections with hyaluronic acid (HA) and platelet-rich plasma (PRP) have been used for decades in order to reduce the symptoms caused by osteoarthritis. In recent years, a combination of HA and PRP has been introduced in clinical practice with the aim to minimize the clinical presentation of osteoarthritis and potentially delay articular degeneration. Materials and Methods: Sixty cases with grade II-III knee osteoarthritis according to the Kellgren-Lawrence classification were included in a prospective study, focused on the evaluation of clinical and functional outcomes after intra-articular knee injections. Cases were randomly divided into three groups. Twenty cases (Group A) were injected with HA, 20 (Group B) had PRP, and the remaining 20 (Group C) received a combination of HA and PRP. Basal WOMAC score and VAS score were recorded before the treatment and repeated within 3 and 6 months after the treatment. Results: At 6-month follow-up, Group C (PRP + HA) was the one with the lowest WOMAC and VAS mean values. It was also the only group that reported a reduction in the two values both in the first three months and in the following three months. No major complication was recorded. Conclusion: The combination of platelet-rich plasma and hyaluronic acid can be effective in the treatment of grade II-III knee osteoarthritis in a short-to-mid-term scenario. It represents an innovative and valuable alternative to the administration of its two components alone.

20.
Healthcare (Basel) ; 11(19)2023 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-37830695

RESUMO

BACKGROUND: Aneurysmal bone cysts (ABCs) are benign but locally aggressive cystic lesions of the bone. Pelvic ABCs are extremely rare and hard to treat due to their high risk of local recurrence and the tough access to pelvic bones. METHODS: In this retrospective study, we evaluated pediatric cases with pelvic ABC treated with curettage, cryotherapy and bone grafting treated in our institution between 2016 and 2022. Complications were recorded, as well as local recurrences. Patients' post-operative functionality was assessed with the MSTS score. RESULTS: Fourteen consecutive cases were included in our study. Their mean age at surgery was 13.5 years. The mean lesion size was 55 mm. The mean follow-up was 38 months. Two cases (11.8%) had local recurrences, which were successfully treated with further curettage. At their latest FU, 13 cases were continuously disease free (CDF), and one had no evidence of disease (NED). Only one case had a post-operative compilation (wound dehiscence). Patients' mean post-operative MSTS score was 29.6. CONCLUSIONS: Pelvic ABCs are a challenge, even for the most experienced orthopedic surgeon. Our study suggests that the association of an accurate curettage, intraoperative cryotherapy and bone grafting can be a reliable and effective therapeutic option for large-sized ABCs of the pelvis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA