RESUMO
Mutation-agnostic treatments such as airway gene therapy have the potential to treat any individual with cystic fibrosis (CF), irrespective of their CF transmembrane conductance regulator (CFTR) gene variants. The aim of this study was to employ two CF rat models, Phe508del and CFTR knockout (KO), to assess the comparative effectiveness of CFTR modulators and lentiviral (LV) vector-mediated gene therapy. Cells were isolated from the tracheas of rats and used to establish air-liquid interface (ALI) cultures. Phe508del rat ALIs were treated with the modulator combination, elexacaftor-tezacaftor-ivacaftor (ETI), and separate groups of Phe508del and KO tracheal epithelial cells were treated with LV-CFTR followed by differentiation at ALI. Ussing chamber measurements were performed to assess CFTR function. ETI-treated Phe508del ALI cultures demonstrated CFTR function that was 59% of wild-type level, while gene-addition therapy restored Phe508del to 68% and KO to 47% of wild-type level, respectively. Our findings show that rat Phe508del-CFTR protein can be successfully rescued with ETI treatment, and that CFTR gene-addition therapy provides significant CFTR correction in Phe508del and KO ALI cultures to levels that were comparable to ETI. These findings highlight the potential of an LV vector-based gene therapy for the treatment of CF lung disease.
RESUMO
PURPOSE: Online adaptive radiotherapy relies on a high degree of automation to enable rapid planning procedures. The Varian Ethos intelligent optimization engine (IOE) was originally designed for conventional treatments so it is crucial to provide clear guidance for lung SAbR plans. This study investigates using the Ethos IOE together with adaptive-specific optimization tuning structures we designed and templated within Ethos to mitigate inter-planner variability in meeting RTOG metrics for both online-adaptive and offline SAbR plans. METHODS: We developed a planning strategy to automate the generation of tuning structures and optimization. This was validated by retrospective analysis of 35 lung SAbR cases (total 105 fractions) treated on Ethos. The effectiveness of our planning strategy was evaluated by comparing plan quality with-and-without auto-generated tuning structures. Internal target volume (ITV) contour was compared between that drawn from CT simulation and from cone-beam CT (CBCT) at time of treatment to verify CBCT image quality and treatment effectiveness. Planning strategy robustness for lung SAbR was quantified by frequency of plans meeting reference plan RTOG constraints. RESULTS: Our planning strategy creates a gradient within the ITV with maximum dose in the core and improves intermediate dose conformality on average by 2%. ITV size showed no significant difference between those contoured from CT simulation and first fraction, and also trended towards decreasing over course of treatment. Compared to non-adaptive plans, adaptive plans better meet reference plan goals (37% vs. 100% PTV coverage compliance, for scheduled and adapted plans) while improving plan quality (improved GI (gradient index) by 3.8%, CI (conformity index) by 1.7%). CONCLUSION: We developed a robust and readily shareable planning strategy for the treatment of adaptive lung SAbR on the Ethos system. We validated that automatic online plan re-optimization along with the formulated adaptive tuning structures can ensure consistent plan quality. With the proposed planning strategy, highly ablative treatments are feasible on Ethos.
Assuntos
Tomografia Computadorizada de Feixe Cônico , Neoplasias Pulmonares , Órgãos em Risco , Radiocirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Tomografia Computadorizada de Feixe Cônico/métodos , Radiocirurgia/métodos , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos , Órgãos em Risco/efeitos da radiação , Processamento de Imagem Assistida por Computador/métodos , AlgoritmosRESUMO
Gene-based therapeutics are actively being pursued for the treatment of lung diseases. While promising advances have been made over the last decades, the absence of clinically available lung-directed genetic therapies highlights the difficulties associated with this effort. Largely, progress has been hindered by the presence of inherent physical and physiological airway barriers that significantly reduce the efficacy of gene transfer. These barriers include surface mucus, mucociliary action, cell-to-cell tight junctions, and the basolateral cell membrane location of viral receptors for many commonly used gene vectors. Accordingly, airway surface preparation methods have been developed to disrupt these barriers, creating a more conducive environment for gene uptake into the target airway cells. The two major approaches have been chemical and physical methods. Both have proven effective for increasing viral-mediated gene transfer pre-clinically, although with variable effect depending on the specific strategy employed. While such methods have been explored extensively in experimental settings, they have not been used clinically. This review covers the airway surface preparation strategies reported in the literature, the advantages and disadvantages of each method, as well as a discussion about applying this concept in the clinic.
Assuntos
Terapia Genética , Pulmão , Pulmão/metabolismo , Vetores GenéticosRESUMO
Lentiviral vectors are attractive delivery vehicles for cystic fibrosis gene therapy owing to their low immunogenicity and ability to integrate into the host cell genome, thereby producing long-term, stable gene expression. Nonetheless, repeat dosing may be required to increase initial expression levels, and/or boost levels when they wane. The primary aim of this study was to determine if repeat dosing of a VSV-G pseudotyped LV vector delivered into mouse lungs is more effective than a single dose. C57Bl/6 mouse lungs were conditioned with lysophosphatidylcholine, followed one-hour later by a LV vector carrying the luciferase reporter gene, using six different short-term (≤1 wk) and long-term (>1 wk) dosing schedules. Luciferase expression was quantified using bioluminescence imaging over 12 months. Most dosing schedules produced detectable bioluminescence over the 12-month period, but the shorter intervals (≤1 wk) produced higher levels of flux than the longest interval (five doses at least 1-month apart). Ex vivo lung analysis at 12 months showed that the estimated mean flux for the group that received two doses 1-week apart was significantly greater than the single dose group and the two groups that received doses over a period greater than 1-week. These results suggest that early consecutive multiple doses are more effective at improving gene expression in mouse lungs at 12 months, than longer repeat dosing intervals.
Assuntos
Fibrose Cística , Lentivirus , Camundongos , Animais , Lentivirus/genética , Transdução Genética , Pulmão , Terapia Genética/métodos , Fibrose Cística/terapia , Camundongos Endogâmicos C57BL , Vetores Genéticos/genéticaRESUMO
While chromosomal rearrangements are ubiquitous in all domains of life, very little is known about their evolutionary significance, mostly because, apart from a few specifically studied and well-documented mechanisms (interaction with recombination, gene duplication, etc.), very few models take them into account. As a consequence, we lack a general theory to account for their direct and indirect contributions to evolution. Here, we propose Aevol, a forward-in-time simulation platform specifically dedicated to unravelling the evolutionary significance of chromosomal rearrangements (CR) compared to local mutations (LM). Using the platform, we evolve populations of organisms in four conditions characterized by an increasing diversity of mutational operators-from substitutions alone to a mix of substitutions, InDels and CR-but with a constant global mutational rate. Despite being almost invisible in the phylogeny owing to the scarcity of their fixation in the lineages, we show that CR make a decisive contribution to the evolutionary dynamics by comparing the outcome in these four conditions. As expected, chromosomal rearrangements allow fast expansion of the gene repertoire through gene duplication, but they also reduce the effect of diminishing-returns epistasis, hence sustaining adaptation on the long-run. At last, we show that chromosomal rearrangements tightly regulate the size of the genome through indirect selection for reproductive robustness. Overall, these results confirm the need to improve our theoretical understanding of the contribution of chromosomal rearrangements to evolution and show that dedicated platforms like Aevol can efficiently contribute to this agenda.
RESUMO
PURPOSE: Deep inspiration breath-hold (DIBH) is crucial in reducing the lung and cardiac dose for treatment of left-sided breast cancer. We compared the stability and reproducibility of two DIBH techniques: Active Breathing Coordinator (ABC) and VisionRT (VRT). MATERIALS AND METHODS: We examined intra- and inter-fraction positional variation of the left lung. Eight left-sided breast cancer patients were monitored with electronic portal imaging during breath-hold (BH) at every fraction. For each patient, half of the fractions were treated using ABC and the other half with VRT, with an equal amount starting with either ABC or VRT. The lung in each portal image was delineated, and the variation of its area was evaluated. Intrafraction stability was evaluated as the mean coefficient of variation (CV) of the lung area for the supraclavicular (SCV) and left lateral (LLat) field over the course of treatment. Reproducibility was the CV for the first image of each fraction. Daily session time and total imaging monitor units (MU) used in patient positioning were recorded. RESULTS: The mean intrafraction stability across all patients for the LLat field was 1.3 ± 0.7% and 1.5 ± 0.9% for VRT and ABC, respectively. Similarly, this was 1.5 ± 0.7% and 1.6 ± 0.8% for VRT and ABC, respectively, for the SCV field. The mean interfraction reproducibility for the LLat field was 11.0 ± 3.4% and 14.9 ± 6.0% for VRT and ABC, respectively. Similarly, this was 13.0 ± 2.5% and 14.8 ± 9% for VRT and ABC, respectively, for the SCV. No difference was observed in the number of verification images required for either technique. CONCLUSIONS: The stability and reproducibility were found to be comparable between ABC and VRT. ABC can have larger interfractional variation with less feedback to the treating therapist compared to VRT as shown in the increase in geometric misses at the matchline.
Assuntos
Neoplasias da Mama , Neoplasias Unilaterais da Mama , Humanos , Feminino , Estudos Prospectivos , Planejamento da Radioterapia Assistida por Computador , Neoplasias Unilaterais da Mama/diagnóstico por imagem , Neoplasias Unilaterais da Mama/radioterapia , Reprodutibilidade dos Testes , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Suspensão da Respiração , CoraçãoRESUMO
BACKGROUND: Active breathing coordinator (ABC)-assisted deep inspiration breath hold (DIBH) is an important organ sparing radiation therapy (RT) technique for left-sided breast cancer patients. Patients with advanced breast cancer undergoing chest wall and regional nodal irradiation often require a field matching technique. While field matching has been demonstrated to be safe and effective in free breathing patients, its safety and accuracy in DIBH/ABC use has not been previously reported. PURPOSE: To report the accuracy, feasibility, and safety of field matching with ABC/DIBH for patients receiving breast/chest wall irradiation with nodal irradiation using a three-field technique. METHODS: From December 2012 to May 2018, breast cancer patients undergoing ABC/DIBH-based RT at a single institution were reviewed. For each fraction, the amount of overlap/gap between the supraclavicular and the tangential field were measured and recorded. Patient characteristics, including acute and delayed skin toxicities, were analyzed. RESULTS: A total of 202 patients utilized ABC/DIBH and 4973 fractions had gap/overlap measurements available for analysis. The average gap/overlap measured at junction was 0.28 mm ± 0.99 mm. A total of 72% of fractions had no measurable gap/overlap (0 mm), while 5.6% had an overlap and 22.7% a gap. There was no significant trend for worsening or improvement of gap/overlap measurements with increasing fraction number per patient. OSLD measurements were compared to the planned dose. The median dose 1 cm above the junction was 106% ± 7% of planned dose (range 94%-116%). One centimeter below the junction, the median dose was 114% ± 11% of planned dose (range 95%-131%). At the junction, the median dose was 106% ± 16.3% of planned dose (range 86%-131%). Acute skin toxicity was similar to historically reported values (grade 3, 5.4%, grade 4, 0%). CONCLUSION: ABC-assisted DIBH is a safe and technically feasible method of delivering RT in the setting of complex matching field technique for breast and regional nodal treatments.
Assuntos
Neoplasias da Mama , Neoplasias Unilaterais da Mama , Humanos , Feminino , Neoplasias da Mama/radioterapia , Suspensão da Respiração , Dosagem Radioterapêutica , Estudos de Viabilidade , Planejamento da Radioterapia Assistida por Computador/métodos , Órgãos em Risco/efeitos da radiação , Neoplasias Unilaterais da Mama/radioterapia , Coração/efeitos da radiaçãoRESUMO
PURPOSE: Ethos CBCT-based adaptive radiotherapy (ART) system can generate an online adaptive plan by re-optimizing the initial reference plan based on the patient anatomy at the treatment. The optimization process is fully automated without any room for human intervention. Due to the change in anatomy, the ART plan can be significantly different from the initial plan in terms of plan parameters such as the aperture shapes and number of monitor units (MUs). In this study, we investigated the feasibility of using calculation-based patient specific QA for ART plans in conjunction with measurement-based and calculation-based QA for initial plans to establish an action level for the online ART patient-specific QA. METHODS: A cohort of 98 cases treated on CBCT-based ART system were collected for this study. We performed measurement-based QA using ArcCheck and calculation-based QA using Mobius for both the initial plan and the ART plan for analysis. For online the ART plan, Mobius calculation was conducted prior to the delivery, while ArcCheck measurement was delivered on the same day after the treatment. We first investigated the modulation factors (MFs) and MU numbers of the initial plans and ART plans, respectively. The γ passing rates of initial and ART plan QA were analyzed. Then action limits were derived for QA calculation and measurement for both initial and online ART plans, respectively, from 30 randomly selected patient cases, and were evaluated using the other 68 patient cases. RESULTS: The difference in MF between initial plan and ART-plan was 12.9% ± 12.7% which demonstrates their significant difference in plan parameters. Based on the patient QA results, pre-treatment calculation and measurement results are generally well aligned with ArcCheck measurement results for online ART plans, illustrating their feasibility as an indicator of failure in online ART QA measurements. Furthermore, using 30 randomly selected patient cases, the γ analysis action limit derived for initial plans and ART plans are 89.6% and 90.4% in ArcCheck QA (2%/2 mm) and are 92.4% and 93.6% in Mobius QA(3%/2 mm), respectively. According to the calculated action limits, the ArcCheck measurements for all the initial and ART plans passed QA successfully while the Mobius calculation action limits flagged seven and four failure cases respectively for initial plans and ART plans, respectively. CONCLUSION: An ART plan can be substantially different from the initial plan, and therefore a separate session of ART plan QA is needed to ensure treatment safety and quality. The pre-treatment QA calculation via Mobius can serve as a reliable indicator of failure in online ART plan QA. However, given that Ethos ART system is still relatively new, ArcCheck measurement of initial plan is still in practice. It may be skipped as we gain more experience and have better understanding of the system.
Assuntos
Radioterapia de Intensidade Modulada , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Garantia da Qualidade dos Cuidados de Saúde , Dosagem RadioterapêuticaRESUMO
PURPOSE: Varian Ethos utilizes novel intelligent-optimization-engine (IOE) designed to automate the planning. However, this introduced a black box approach to plan optimization and challenge for planners to improve plan quality. This study aims to evaluate machine-learning-guided initial reference plan generation approaches for head & neck (H&N) adaptive radiotherapy (ART). METHODS: Twenty previously treated patients treated on C-arm/Ring-mounted were retroactively re-planned in the Ethos planning system using a fixed 18-beam intensity-modulated radiotherapy (IMRT) template. Clinical goals for IOE input were generated using (1) in-house deep-learning 3D-dose predictor (AI-Guided) (2) commercial knowledge-based planning (KBP) model with universal RTOG-based population criteria (KBP-RTOG) and (3) an RTOG-based constraint template only (RTOG) for in-depth analysis of IOE sensitivity. Similar training data was utilized for both models. Plans were optimized until their respective criteria were achieved or DVH-estimation band was satisfied. Plans were normalized such that the highest PTV dose level received 95% coverage. Target coverage, high-impact organs-at-risk (OAR) and plan deliverability was assessed in comparison to clinical (benchmark) plans. Statistical significance was evaluated using a paired two-tailed student t-test. RESULTS: AI-guided plans were superior to both KBP-RTOG and RTOG-only plans with respect to clinical benchmark cases. Overall, OAR doses were comparable or improved with AI-guided plans versus benchmark, while they increased with KBP-RTOG and RTOG plans. However, all plans generally satisfied the RTOG criteria. Heterogeneity Index (HI) was on average <1.07 for all plans. Average modulation factor was 12.2 ± 1.9 (p = n.s), 13.1 ± 1.4 (p = <0.001), 11.5 ± 1.3 (p = n.s.) and 12.2 ± 1.9 for KBP-RTOG, AI-Guided, RTOG and benchmark plans, respectively. CONCLUSION: AI-guided plans were the highest quality. Both KBP-enabled and RTOG-only plans are feasible approaches as clinics adopt ART workflows. Similar to constrained optimization, the IOE is sensitive to clinical input goals and we recommend comparable input to an institution's planning directive dosimetric criteria.
Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Pescoço , Órgãos em Risco , Radioterapia de Intensidade Modulada/métodos , Aprendizado de MáquinaRESUMO
PURPOSE: Describe an early-adopting institution's experience with online adaptive radiation for stereotactic partial breast irradiation. METHODS AND MATERIALS: Retrospective review of 22 women treated between May 2021 and March 2022 with adaptive stereotactic partial breast irradiation. A total of 106 of 110 fractions were evaluated for dosimetric changes in target coverage and organ-at-risk (OAR) dose. Patient set up with stereotactic wooden frame and adapted per fraction. Treatment and planning times were collected prospectively by radiation therapists. RESULTS: Scheduled PTV30 Gy was <95% in 72.1% and <90% in 38.5% of fractions, and both PTV and CTV coverage were improved significantly after adaption, and 83.7% of fractions were delivered as adapted per physician choice. There was no difference in OAR coverage. Average adaptive treatment planning took 15 min and average time-on-couch was 34.4 min. CONCLUSIONS: Adaptive stereotactic breast irradiation resulted in improved target coverage with equivalent dosing to OARs in an efficient and tolerated treatment time. Improved target coverage allowed for decreased PTV margins compared to prior trial protocols that may improve acute and late toxicities.
Assuntos
Órgãos em Risco , Radiocirurgia , Humanos , Feminino , Dosagem Radioterapêutica , Órgãos em Risco/efeitos da radiação , Estudos de Viabilidade , Planejamento da Radioterapia Assistida por Computador/métodos , Radiocirurgia/métodosRESUMO
BACKGROUND: Administering allergens in increasing doses can temporarily suppress IgE-mediated allergy and anaphylaxis by desensitizing mast cells and basophils; however, allergen administration during desensitization therapy can itself induce allergic responses. Several small molecule drugs and nutraceuticals have been used clinically and experimentally to suppress these allergic responses. OBJECTIVES: This study sought to optimize drug inhibition of IgE-mediated anaphylaxis. METHODS: Several agents were tested individually and in combination for ability to suppress IgE-mediated anaphylaxis in conventional mice, FcεRIα-humanized mice, and reconstituted immunodeficient mice that have human mast cells and basophils. Hypothermia was the readout for anaphylaxis; therapeutic efficacy was measured by degree of inhibition of hypothermia. Serum mouse mast cell protease 1 level was used to measure extent of mast cell degranulation. RESULTS: Histamine receptor 1 (HR1) antagonists, ß-adrenergic agonists, and a spleen tyrosine kinase (Syk) inhibitor were best at individually inhibiting IgE-mediated anaphylaxis. A Bruton's tyrosine kinase (BTK) inhibitor, administered alone, only inhibited hypothermia when FcεRI signaling was suboptimal. Combinations of these agents could completely or nearly completely inhibit IgE-mediated hypothermia in these models. Both Syk and BTK inhibition decreased mast cell degranulation, but only Syk inhibition also blocked desensitization. Many other agents that are used clinically and experimentally had little or no beneficial effect. CONCLUSIONS: Combinations of an HR1 antagonist, a ß-adrenergic agonist, and a Syk or a BTK inhibitor protect best against IgE-mediated anaphylaxis, while an HR1 antagonist plus a ß-adrenergic agonist ± a BTK antagonist is optimal for inhibiting IgE-mediated anaphylaxis without suppressing desensitization.
Assuntos
Anafilaxia/prevenção & controle , Imunoglobulina E/imunologia , Agonistas Adrenérgicos beta/uso terapêutico , Animais , Quimioterapia Combinada , Antagonistas dos Receptores Histamínicos/uso terapêutico , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C57BL , Inibidores de Proteínas Quinases/uso terapêutico , Proteínas Tirosina Quinases/antagonistas & inibidoresRESUMO
Cystic fibrosis (CF), the result of mutations in the CF transmembrane conductance regulator (CFTR), causes essential fatty acid deficiency. The aim of this study was to characterize fatty acid handling in two rodent models of CF; one strain which harbors the loss of phenylalanine at position 508 (Phe508del) in CFTR and the other lacks functional CFTR (510X). Fatty acid concentrations were determined using gas chromatography in serum from Phe508del and 510X rats. The relative expression of genes responsible for fatty acid transport and metabolism were quantified using real-time PCR. Ileal tissue morphology was assessed histologically. There was an age-dependent decrease in eicosapentaenoic acid and the linoleic acid:α-linolenic acid ratio, a genotype-dependent decrease in docosapentaenoic acid (n-3) and an increase in the arachidonic acid:docosahexaenoic acid ratio in Phe508del rat serum, which was not observed in 510X rats. In the ileum, Cftr mRNA was increased in Phe508del rats but decreased in 510X rats. Further, Elvol2, Slc27a1, Slc27a2 and Got2 mRNA were increased in Phe508del rats only. As assessed by Sirius Red staining, collagen was increased in Phe508del and 510X ileum. Thus, CF rat models exhibit alterations in the concentration of circulating fatty acids, which may be due to altered transport and metabolism, in addition to fibrosis and microscopic structural changes in the ileum.
Assuntos
Fibrose Cística , Ratos , Animais , Fibrose Cística/metabolismo , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Regulador de Condutância Transmembrana em Fibrose Cística/metabolismo , Roedores/metabolismo , Ácidos Graxos Essenciais , Genótipo , Coenzima A Ligases/metabolismoRESUMO
Over the past 30 years, a range of cystic fibrosis (CF) animal models have been generated for research purposes. Different species, including mice, rats, ferrets, rabbits, pigs, sheep, zebrafish, and fruit flies, have all been used to model CF disease. While access to such a variety of animal models is a luxury for any research field, it also complicates the decision-making process when it comes to selecting the right model for an investigation. The purpose of this review is to provide a guide for selecting the most appropriate CF animal model for any given application. In this review, the characteristics and phenotypes of each animal model are described, along with a discussion of the key considerations that must be taken into account when choosing a suitable animal model. Available in vitro systems of CF are also described and can offer a useful alternative to using animal models. Finally, the future of CF animal model generation and its use in research are speculated upon.
Assuntos
Fibrose Cística , Modelos Animais de Doenças , Animais , Técnicas de Cultura de CélulasRESUMO
Essential fatty acid deficiency has been observed in most patients with Cystic Fibrosis (CF); however, pancreatic supplementation does not restore the deficiency, suggesting a different pathology independent of the pancreas. At this time, the underlying pathological mechanisms are largely unknown. Essential fatty acids are obtained from the diet and processed by organs including the liver and intestine, two organs significantly impacted by mutations in the cystic fibrosis transmembrane conductance regulator gene (Cftr). There are several CF animal models in a variety of species that have been developed to investigate molecular mechanisms associated with the CF phenotype. Specifically, global and systemic mutations in Cftr which mimic genotypic changes identified in CF patients have been generated in mice, rats, sheep, pigs and ferrets. These mutations produce CFTR proteins with a gating defect, trafficking defect, or an absent or inactive CFTR channel. Essential fatty acids are critical to CFTR function, with a bidirectional relationship between CFTR and essential fatty acids proposed. Currently, there are limited analyses on the essential fatty acid status in most of these animal models. Of interest, in the mouse model, essential fatty acid status is dependent on the genotype and resultant phenotype of the mouse. Future investigations should identify an optimal animal model that has most of the phenotypic changes associated with CF including the essential fatty acid deficiencies, which can be used in the development of therapeutics.
Assuntos
Animais Geneticamente Modificados , Fibrose Cística/patologia , Modelos Animais de Doenças , Ácidos Graxos Essenciais/deficiência , Fenótipo , Animais , Fibrose Cística/etiologia , Fibrose Cística/metabolismo , Humanos , Transporte de ÍonsRESUMO
PURPOSE: To automate the generation of region-of-interest (ROI) apertures for use with megavoltage imaging for online positional corrections during cranial stereotactic radiosurgery. MATERIALS AND METHODS: Digitally reconstructed radiographs (DRRs) were created for a 3D-printed skull phantom at 5 degree gantry angle increments for a three-arc beam arrangement. At each angle, 3000 random rectangular apertures were generated, and 100 shifts on a grid were applied to the anatomy within the frame. For all shifts, the mutual information (MI) between the shifted and unshifted DRR was calculated to derive an average MI gradient. The top 10% of apertures that minimized registration errors were overlaid and discretely thresholded to generate imaging plans. Imaging was acquired with the skull while implementing simulated patient motion on a linac. Control point-specific couch motions were derived to align the skull to its planned positioning. RESULTS: Apertures with a range of repositioning errors less than 0.1 mm possessed a 42% larger average MI gradient when compared with apertures with a range greater than 1 mm. Dose calculations with Monte Carlo exhibited an 84% reduction in the dose received by 50% of the skull with the 50% thresholded plan when compared to a constant 22 × 22 cm2 imaging plan. For all different imaging plans (with and without motion), the calculated median 3D-errors with respect to the tracking of a metal-BB fiducial positioned at isocenter in the skull were sub-mm except for the 80% thresholded plan. CONCLUSIONS: Sub-mm positional errors are achievable with couch motions derived from control point-specific ROI imaging. Smaller apertures that conform to an anatomical ROI can be utilized to minimize the imaging dose incurred at the expense of larger errors.
Assuntos
Radiocirurgia , Planejamento da Radioterapia Assistida por Computador , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Radiocirurgia/métodos , Imagens de Fantasmas , Crânio/diagnóstico por imagemRESUMO
MOTIVATION: Gene and species tree reconciliation methods are used to interpret gene trees, root them and correct uncertainties that are due to scarcity of signal in multiple sequence alignments. So far, reconciliation tools have not been integrated in standard phylogenetic software and they either lack performance on certain functions, or usability for biologists. RESULTS: We present Treerecs, a phylogenetic software based on duplication-loss reconciliation. Treerecs is simple to install and to use. It is fast and versatile, has a graphic output, and can be used along with methods for phylogenetic inference on multiple alignments like PLL and Seaview. AVAILABILITY AND IMPLEMENTATION: Treerecs is open-source. Its source code (C++, AGPLv3) and manuals are available from https://project.inria.fr/treerecs/.
Assuntos
Algoritmos , Evolução Molecular , Filogenia , Alinhamento de Sequência , SoftwareRESUMO
Animal models of cystic fibrosis (CF) are essential for investigating disease mechanisms and trialing potential therapeutics. This study generated two CF rat models using clustered regularly interspaced short palindromic repeats/clustered regularly interspaced short palindromic repeats-associated protein 9 gene editing. One rat model carries the common human Phe508del (ΔF508) CF transmembrane conductance regulator (CFTR) mutation, whereas the second is a CFTR knockout model. Phenotype was characterized using a range of functional and histologic assessments, including nasal potential difference to measure electrophysiological function in the upper airways, RNAscope in situ hybridization and quantitative PCR to assess CFTR mRNA expression in the lungs, immunohistochemistry to localize CFTR protein in the airways, and histopathologic assessments in a range of tissues. Both rat models revealed a range of CF manifestations, including reduced survival, intestinal obstruction, bioelectric defects in the nasal epithelium, histopathologic changes in the trachea, large intestine, and pancreas, and abnormalities in the development of the male reproductive tract. The CF rat models presented herein will prove useful for longitudinal assessments of pathophysiology and therapeutics.
Assuntos
Regulador de Condutância Transmembrana em Fibrose Cística/deficiência , Fibrose Cística , Modelos Animais de Doenças , Edição de Genes/métodos , Animais , Sistemas CRISPR-Cas , Fibrose Cística/genética , Fibrose Cística/patologia , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Humanos , Camundongos Knockout , Mutação , Fenótipo , Ratos , Ratos Sprague-DawleyRESUMO
Current gene therapy delivery protocols for small animal lungs typically utilize indirect dose delivery via the nasal airways, or bolus delivery directly into the trachea. Both methods can result in variable transduction throughout the lung, as well as between animals, and cannot be applied in a targeted manner. To minimize variability and improve lung coverage we previously developed and validated a method to visualize and dose gene vectors into pre-selected lobes of rat lungs using a mini-bronchoscope. Lentiviral (LV) vectors are known to be fragile and can be inactivated easily by temperature or the application of shear stresses. There are several ways that the bronchoscope could be configured to deliver the LV vector, and these could result in different amounts of functional LV vector being delivered to the lung. This study evaluated several methods of LV vector delivery through the bronchoscope, and how flow rates and LV vector stabilizing diluents impact LV vector delivery. NIH-3T3 cells were exposed to LV vector containing the green fluorescent protein (GFP) reporter gene using various bronchoscopic delivery techniques and the number of GFP-positive cells produced by each was quantified by flow cytometry. The results showed that directly drawing the LV vector into the bronchoscope tip resulted in 80-90% recovery of viable vector, and was also the simplest method of delivery. The fluid delivery rate and the use of stabilizing serum in the vector diluent had no effect on the viability of the LV vector delivered. These findings can be used to optimize LV vector dose delivery into individual lung lobes of small animal models.
Assuntos
Broncoscópios , Lentivirus , Animais , Técnicas de Transferência de Genes , Vetores Genéticos , Lentivirus/genética , Pulmão , Camundongos , RatosRESUMO
PURPOSE: Intrafraction patient motion is a well-documented phenomenon in radiation therapy. In stereotactic radiosurgery applications in which target sizes can be very small and dose gradients very steep, patient motion can significantly impact the magnitude and positional accuracy of the delivered dose. This work investigates the impact of intrafraction motion on dose metrics for small targets when treated with a virtual cone. MATERIALS AND METHODS: Monte Carlo simulations were performed to calculate dose kernels for treatment apertures ranging from 1 × 2.5 mm2 to 10 × 10 mm2 . The phantom was an 8.2-cm diameter sphere and isotropic voxels had lengths of 0.25 mm. Simulated treatments consisted of 3 arcs: 1 axial arc (360° gantry rotation, couch angle 0°) and 2 oblique arcs (180° gantry rotation, couch angle ±45°). Dose distributions were calculated via superposition of the rotated kernels. Two different collimator orientations were considered to create a virtual cone: (a) each treatment arc was delivered twice, once each with a static collimator angle of ±45°, and (b) each treatment arc was delivered once, with dynamic collimator rotation throughout the arc. Two different intrafraction motion patterns were considered: (a) constant linear motion and (b) sudden, persistent motion. The impact of motion on dose distributions for target sizes ranging from 1 to 10 mm diameter spheres was quantified as a function of the aperture size used to treat the lesions. RESULTS: The impact of motion on both the target and the surrounding tissue was a function of both aperture shape and target size. When a 0.5-mm linear drift along each dimension occurred during treatment, targets ≥5 mm saw less than a 10% decrease in coverage by the prescription dose. Smaller apertures accrued larger penalties with respect to dosimetric hotspots seen in the tissues surrounding the target volume during intrafraction motion. For example, treating a 4-mm-sized target that undergoes 2.60 mm (3D vector) of continuous linear motion, the D5 in the concentric shells that extend 1, 2, and 3 mm from the surface of the target was 39%, 24%, and 14% smaller, respectively when comparing the delivery of a larger aperture (6 × 10 mm2 ) to a smaller aperture (2 × 5 mm2 ). Using a static collimator for shaping a virtual cone during treatment minimized the dosimetric impact of motion in the majority of cases. For example, the volume that is covered by 70% or more of the prescription dose is smaller in 60.4% of cases when using the static collimator. The volume covered by 50, and 30% or more of the prescription dose is also smaller when treating with a static collimator, but the clinical significance of this finding is unknown. CONCLUSIONS: In this work, the dosimetric trade-offs between aperture size and target size when irradiating with virtual cones has been demonstrated. These findings provide information about the tradeoffs between target coverage and normal tissue sparing that may help inform clinical decision making when treating smaller targets with virtual cones.
Assuntos
Radiometria , Radiocirurgia , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , RotaçãoRESUMO
Small-animal physiology studies are typically complicated, but the level of complexity is greatly increased when performing live-animal X-ray imaging studies at synchrotron and compact light sources. This group has extensive experience in these types of studies at the SPring-8 and Australian synchrotrons, as well as the Munich Compact Light Source. These experimental settings produce unique challenges. Experiments are always performed in an isolated radiation enclosure not specifically designed for live-animal imaging. This requires equipment adapted to physiological monitoring and test-substance delivery, as well as shuttering to reduce the radiation dose. Experiment designs must also take into account the fixed location, size and orientation of the X-ray beam. This article describes the techniques developed to overcome the challenges involved in respiratory X-ray imaging of live animals at synchrotrons, now enabling increasingly sophisticated imaging protocols.