1.
Circulation ; 115(18): 2382-9, 2007 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-17470697

RESUMO

BACKGROUND: Implantable cardioverter-defibrillators and cardiac resynchronization therapy defibrillators have relied on multiple ventricular fibrillation (VF) induction/defibrillation tests at implantation to ensure that the device can reliably sense, detect, and convert VF. The ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations) is the first large, multicenter, prospective trial comparing vulnerability safety margin testing versus defibrillation safety margin testing with a single VF induction/defibrillation. METHODS AND RESULTS: A total of 426 patients receiving an implantable cardioverter-defibrillator or cardiac resynchronization therapy defibrillator underwent vulnerability safety margin or defibrillation safety margin screening at 14 J in a randomized order. After this, patients underwent confirmatory testing, which required 2 VF conversions without failure at < or = 21 J. Patients who passed their first 14-J and confirmatory tests, irrespective of the results of their second 14-J test, had their devices programmed to a 21-J shock for ventricular tachycardia (VT) or VF > or = 200 bpm and were followed up for 1 year. Of 420 patients who underwent 14-J vulnerability safety margin screening, 322 (76.7%) passed. Of these, 317 (98.4%) also passed 21-J confirmatory tests. Of 416 patients who underwent 14-J defibrillation safety margin screening, 343 (82.5%) passed, and 338 (98.5%) also passed 21-J confirmatory tests. Most clinical VT/VF episodes (32 of 37, or 86%) were terminated by the first shock, with no difference in first shock success. In all observed cases in which the first shock was unsuccessful, subsequent shocks terminated VT/VF without complication. CONCLUSIONS: Although spontaneous episodes of fast VT/VF were limited, there was no difference in the odds of first shock efficacy between groups. Screening with vulnerability safety margin or defibrillation safety margin may allow for inductionless or limited shock testing in most patients.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Estimulação Elétrica , Fibrilação Ventricular/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/complicações , Arritmias Cardíacas/tratamento farmacológico , Fármacos Cardiovasculares/uso terapêutico , Terapia Combinada , Estudos Cross-Over , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/normas , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Projetos de Pesquisa , Comportamento de Redução do Risco , Método Simples-Cego , Procedimentos Desnecessários , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA