Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Biochem Med (Zagreb) ; 30(3): 030701, 2020 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-32774123

RESUMO

INTRODUCTION: There is a growing amount of evidence showing the significant analytical bias of steroid hormone immunoassays, but large number of available immunoassays makes conduction of a single comprehensive study of this issue hardly feasible. Aim of this study was to assess the analytical bias of six heterogeneous immunoassays for serum aldosterone, cortisol, dehydroepiandrosterone sulphate (DHEAS), testosterone, 17-hydroxyprogesterone (OHP) and progesterone using the liquid chromatography coupled to the tandem mass spectrometry (LC-MS/MS). MATERIALS AND METHODS: This method comparison study included 49 serum samples. Testosterone, DHEAS, progesterone and cortisol immunoassays were performed on the Abbott Architect i2000SR or Alinity i analysers (Abbott Diagnostics, Chicago, USA). DiaSorin's Liaison (DiaSorin, Saluggia, Italy) and DIAsource's ETI-Max 3000 analysers (DIAsource ImmunoAssays, Louvain-La-Neuve, Belgium) were chosen for aldosterone and OHP immunoassay testing, respectively. All immunoassays were evaluated against the LC-MS/MS assay relying on the commercial kit (Chromsystems, Gräfelfing, Germany) and LCMS-8050 analyser (Shimadzu, Kyoto, Japan). Analytical biases were calculated and method comparison was conducted using weighted Deming regression analysis. RESULTS: Depending on the analyte and specific immunoassay, mean relative biases ranged from -31 to + 137%. Except for the cortisol, immunoassays were positively biased. For none of the selected steroids slope and intercept 95% confidence intervals simultaneously contained 0 and 1, respectively. CONCLUSIONS: Evaluated immunoassays failed to satisfy requirements for methods' comparability and produced significant analytical biases in respect to the LC-MS/MS assay, especially at low concentrations.


Assuntos
Cromatografia Líquida de Alta Pressão , Imunoensaio , Esteroides/sangue , Espectrometria de Massas em Tandem , 17-alfa-Hidroxiprogesterona/sangue , Adulto , Aldosterona/sangue , Automação , Viés , Sulfato de Desidroepiandrosterona/sangue , Feminino , Humanos , Hidrocortisona/sangue , Masculino , Pessoa de Meia-Idade , Progesterona/sangue , Kit de Reagentes para Diagnóstico , Testosterona/sangue , Adulto Jovem
2.
Coll Antropol ; 31(1): 345-8, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17598422

RESUMO

Determination of anti-citrullinated peptides (anti-CCP) specificity as a predictor of joint erosive changes, correlation between their serum level and radiological damages as well as disease activity score (DAS28). A trial has been conducted on a 211 patient sample fulfilling ACR criteria for rheumatoid arthritis (RA). There was assigned anti-CCP serum level, disease activity score by the formula for DAS28(3)-CRP and assessed radiological changes degree after Steinbrocker score. In 132 patient (62.559%) the serum anti-CCP concentration was positive for RA. Specificity of the test was 100% and sensitivity 65% (Z = 0.731, p = 0.465). There is a medium intensity correlation between variables representing anti-CCP and Steinbrocker score. Pearson's coefficient was 0.479 and Spearman's rank correlation coefficient was 0.614, i.e. statistically significant (p = 0.000). There is no statistically significant correlation between variables representing anti-CCP and DAS28(3)-CRP Anti-CCP are good RA predictor and their concentration correlate with radiological damages degree.


Assuntos
Artrite Reumatoide/diagnóstico , Autoanticorpos/sangue , Peptídeos Cíclicos/imunologia , Adulto , Idoso , Artrite Reumatoide/diagnóstico por imagem , Artrite Reumatoide/imunologia , Artrografia , Proteína C-Reativa/análise , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA