Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
BMC Anesthesiol ; 23(1): 71, 2023 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-36882701

RESUMO

BACKGROUND: We recently reported the results for a large randomized controlled trial of low tidal volume ventilation (LTVV) versus conventional tidal volume (CTVV) during major surgery when positive end expiratory pressure (PEEP) was equal between groups. We found no difference in postoperative pulmonary complications (PPCs) in patients who received LTVV. However, in the subgroup of patients undergoing laparoscopic surgery, LTVV was associated with a numerically lower rate of PPCs after surgery. We aimed to further assess the relationship between LTVV versus CTVV during laparoscopic surgery. METHODS: We conducted a post-hoc analysis of this pre-specified subgroup. All patients received volume-controlled ventilation with an applied PEEP of 5 cmH2O and either LTVV (6 mL/kg predicted body weight [PBW]) or CTVV (10 mL/kg PBW). The primary outcome was the incidence of a composite of PPCs within seven days. RESULTS: Three hundred twenty-eight patients (27.2%) underwent laparoscopic surgeries, with 158 (48.2%) randomised to LTVV. Fifty two of 157 patients (33.1%) assigned to LTVV and 72 of 169 (42.6%) assigned to conventional tidal volume developed PPCs within 7 days (unadjusted absolute difference, - 9.48 [95% CI, - 19.86 to 1.05]; p = 0.076). After adjusting for pre-specified confounders, the LTVV group had a lower incidence of the primary outcome than patients receiving CTVV (adjusted absolute difference, - 10.36 [95% CI, - 20.52 to - 0.20]; p = 0.046). CONCLUSION: In this post-hoc analysis of a large, randomised trial of LTVV we found that during laparoscopic surgeries, LTVV was associated with a significantly reduced PPCs compared to CTVV when PEEP was applied equally between both groups. TRIAL REGISTRATION: Australian and New Zealand Clinical Trials Registry no: 12614000790640.


Assuntos
Laparoscopia , Respiração , Humanos , Volume de Ventilação Pulmonar , Austrália , Nova Zelândia , Complicações Pós-Operatórias/epidemiologia
2.
BMC Anesthesiol ; 22(1): 149, 2022 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-35578170

RESUMO

BACKGROUND: Low tidal volume (VT) ventilation and its associated increase in arterial carbon dioxide (PaCO2) may affect postoperative neurologic function. We aimed to test the hypothesis that intraoperative low VT ventilation affect the incidence of postoperative ICD-10 coded delirium and/or the need for antipsychotic medications. METHODS: This is a post-hoc analysis of a large randomized controlled trial evaluating low vs. conventional VT ventilation during major non-cardiothoracic, non-intracranial surgery. The primary outcome was the incidence of ICD-10 delirium and/or the use of antipsychotic medications during hospital stay, and the absolute difference with its 95% confidence interval (CI) was calculated. RESULTS: We studied 1206 patients (median age of 64 [55-72] years, 59.0% males, median ARISCAT of 26 [19-37], and 47.6% of ASA 3). ICD-10 coded delirium and /or antipsychotic medication use was diagnosed in 11.2% with similar incidence between low and conventional VT ventilation (11.1% vs. 11.3%; absolute difference, -0.24 [95%CI, -3.82 to 3.32]; p = 0.894). There was no interaction between allocation group and type of surgery. CONCLUSION: In adult patients undergoing major surgery, low VT ventilation was not associated with increased risk of ICD-10 delirium and/or the use of antipsychotic medications during hospital stay. TRIAL REGISTRATION: ANZCTR Identifier: ACTRN12614000790640 .


Assuntos
Antipsicóticos , Delírio , Adulto , Idoso , Antipsicóticos/efeitos adversos , Delírio/induzido quimicamente , Delírio/epidemiologia , Feminino , Humanos , Classificação Internacional de Doenças , Masculino , Pessoa de Meia-Idade , Respiração com Pressão Positiva/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Respiração Artificial , Volume de Ventilação Pulmonar
3.
Eur J Anaesthesiol ; 39(1): 67-74, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34560687

RESUMO

BACKGROUND: Studies in critically ill patients suggest a relationship between mechanical power (an index of the energy delivered by the ventilator, which includes driving pressure, respiratory rate, tidal volume and inspiratory pressure) and complications. OBJECTIVE: We aimed to assess the association between intra-operative mechanical power and postoperative pulmonary complications (PPCs). DESIGN: Post hoc analysis of a large randomised clinical trial. SETTING: University-affiliated academic tertiary hospital in Melbourne, Australia, from February 2015 to February 2019. PATIENTS: Adult patients undergoing major noncardiothoracic, nonintracranial surgery. INTERVENTION: Dynamic mechanical power was calculated using the power equation adjusted by the respiratory system compliance (CRS). Multivariable models were used to assess the independent association between mechanical power and outcomes. MAIN OUTCOME MEASURES: The primary outcome was the incidence of PPCs within the first seven postoperative days. The secondary outcome was the incidence of acute respiratory failure. RESULTS: We studied 1156 patients (median age [IQR]: 64 [55 to 72] years, 59.5% men). Median mechanical power adjusted by CRS was 0.32 [0.22 to 0.51] (J min-1)/(ml cmH2O-1). A higher mechanical power was also independently associated with increased risk of PPCs [odds ratio (OR 1.34, 95% CI, 1.17 to 1.52); P < 0.001) and acute respiratory failure (OR 1.40, 95% CI, 1.21 to 1.61; P < 0.001). CONCLUSION: In patients receiving ventilation during major noncardiothoracic, nonintracranial surgery, exposure to a higher mechanical power was independently associated with an increased risk of PPCs and acute respiratory failure. TRIAL REGISTRATION: Australia and New Zealand Clinical Trials Registry no: 12614000790640.


Assuntos
Pulmão , Ventiladores Mecânicos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Período Pós-Operatório , Respiração Artificial/efeitos adversos , Volume de Ventilação Pulmonar
4.
BMC Anesthesiol ; 20(1): 207, 2020 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-32814546

RESUMO

BACKGROUND: Our study aimed to test the hypothesis that the addition of intrathecal morphine (ITM) results in reduced postoperative opioid use and enhanced postoperative analgesia in patients undergoing open liver resection using a standardized enhanced recovery after surgery (ERAS) protocol with multimodal analgesia. METHODS: A retrospective analysis of 216 adult patients undergoing open liver resection between June 2010 and July 2017 at a university teaching hospital was conducted. The primary outcome was the cumulative oral morphine equivalent daily dose (oMEDD) on postoperative day (POD) 1. Secondary outcomes included postoperative pain scores, opioid related complications, and length of hospital stay. We also performed a cost analysis evaluating the economic benefits of ITM. RESULTS: One hundred twenty-five patients received ITM (ITM group) and 91 patients received usual care (UC group). Patient characteristics were similar between the groups. The primary outcome - cumulative oMEDD on POD1 - was significantly reduced in the ITM group. Postoperative pain scores up to 24 h post-surgery were significantly reduced in the ITM group. There was no statistically significant difference in complications or hospital stay between the two study groups. Total hospital costs were significantly higher in the ITM group. CONCLUSION: In patients undergoing open liver resection, ITM in addition to conventional multimodal analgesic strategies reduced postoperative opioid requirements and improved analgesia for 24 h after surgery, without any statistically significant differences in opioid-related complications, and length of hospital stay. Hospital costs were significantly higher in patients receiving ITM, reflective of a longer mandatory stay in intensive care. TRIAL REGISTRATION: Registered with the Australian New Zealand Clinical Trials Registry (ANZCTR) under ACTRN12620000001998 .


Assuntos
Analgesia/métodos , Analgésicos Opioides/administração & dosagem , Injeções Espinhais/métodos , Hepatopatias/cirurgia , Manejo da Dor/métodos , Dor Pós-Operatória/prevenção & controle , Idoso , Feminino , Humanos , Hepatopatias/epidemiologia , Masculino , Pessoa de Meia-Idade , Morfina/administração & dosagem , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/epidemiologia , Estudos Retrospectivos , Vitória/epidemiologia
5.
JAMA ; 324(9): 848-858, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32870298

RESUMO

Importance: In patients who undergo mechanical ventilation during surgery, the ideal tidal volume is unclear. Objective: To determine whether low-tidal-volume ventilation compared with conventional ventilation during major surgery decreases postoperative pulmonary complications. Design, Setting, and Participants: Single-center, assessor-blinded, randomized clinical trial of 1236 patients older than 40 years undergoing major noncardiothoracic, nonintracranial surgery under general anesthesia lasting more than 2 hours in a tertiary hospital in Melbourne, Australia, from February 2015 to February 2019. The last date of follow-up was February 17, 2019. Interventions: Patients were randomized to receive a tidal volume of 6 mL/kg predicted body weight (n = 614; low tidal volume group) or a tidal volume of 10 mL/kg predicted body weight (n = 592; conventional tidal volume group). All patients received positive end-expiratory pressure (PEEP) at 5 cm H2O. Main Outcomes and Measures: The primary outcome was a composite of postoperative pulmonary complications within the first 7 postoperative days, including pneumonia, bronchospasm, atelectasis, pulmonary congestion, respiratory failure, pleural effusion, pneumothorax, or unplanned requirement for postoperative invasive or noninvasive ventilation. Secondary outcomes were postoperative pulmonary complications including development of pulmonary embolism, acute respiratory distress syndrome, systemic inflammatory response syndrome, sepsis, acute kidney injury, wound infection (superficial and deep), rate of intraoperative need for vasopressor, incidence of unplanned intensive care unit admission, rate of need for rapid response team call, intensive care unit length of stay, hospital length of stay, and in-hospital mortality. Results: Among 1236 patients who were randomized, 1206 (98.9%) completed the trial (mean age, 63.5 years; 494 [40.9%] women; 681 [56.4%] undergoing abdominal surgery). The primary outcome occurred in 231 of 608 patients (38%) in the low tidal volume group compared with 232 of 590 patients (39%) in the conventional tidal volume group (difference, -1.3% [95% CI, -6.8% to 4.2%]; risk ratio, 0.97 [95% CI, 0.84-1.11]; P = .64). There were no significant differences in any of the secondary outcomes. Conclusions and Relevance: Among adult patients undergoing major surgery, intraoperative ventilation with low tidal volume compared with conventional tidal volume, with PEEP applied equally between groups, did not significantly reduce pulmonary complications within the first 7 postoperative days. Trial Registration: ANZCTR Identifier: ACTRN12614000790640.


Assuntos
Pneumopatias/prevenção & controle , Respiração com Pressão Positiva/métodos , Complicações Pós-Operatórias/prevenção & controle , Procedimentos Cirúrgicos Operatórios , Volume de Ventilação Pulmonar , Adulto , Feminino , Humanos , Incidência , Cuidados Intraoperatórios , Pneumopatias/epidemiologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Período Pós-Operatório , Método Simples-Cego , Procedimentos Cirúrgicos Operatórios/efeitos adversos
6.
BMC Surg ; 17(1): 10, 2017 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-28114921

RESUMO

BACKGROUND: Perioperative thermal disturbances during orthotopic liver transplantation (OLT) are common. We hypothesized that in patients undergoing OLT the use of a humidified high flow CO2 warming system maintains higher intraoperative temperatures when compared to standardized multimodal strategies to maintain thermoregulatory homeostasis. METHODS: We performed a randomized pilot study in adult patients undergoing primary OLT. Participants were randomized to receive either open wound humidification with a high flow CO2 warming system in addition to standard care (Humidification group) or to standard care alone (Control group). The primary end point was nasopharyngeal core temperature measured 5 min immediately prior to reperfusion of the donor liver (Stage 3 - 5 min). Secondary endpoints included intraoperative PaCO2, minute ventilation and the use of vasoconstrictors. RESULTS: Eleven patients were randomized to each group. Both groups were similar for age, body mass index, MELD, SOFA and APACHE II scores, baseline temperature, and duration of surgery. Immediately prior to reperfusion (Stage 3 - 5 min) the mean (SD) core temperature was higher in the Humidification Group compared to the Control Group: 36.0 °C (0.13) vs. 35.4 °C (0.22), p = 0.028. Repeated measured ANOVA showed that core temperatures over time during the stages of the transplant were higher in the Humidification Group compared to the Control Group (p < 0.0001). There were no significant differences in the ETCO2, PaCO2, minute ventilation, or inotropic support. CONCLUSION: The humidified high flow CO2 warming system was superior to standardized multimodal strategies in maintaining normothermia in patients undergoing OLT. Use of the device was feasible and did not interfere with any aspects of surgery. A larger study is needed to investigate if the improved thermoregulation observed is associated with improved patient outcomes. TRIAL REGISTRATION: ACTRN12616001631493 . Retrospectively registered 25 November 2016.


Assuntos
Hipotermia/prevenção & controle , Transplante de Fígado/instrumentação , Adulto , Temperatura Corporal , Estudos de Viabilidade , Feminino , Temperatura Alta , Humanos , Umidade , Hipotermia/etiologia , Transplante de Fígado/efeitos adversos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos
7.
J Clin Monit Comput ; 31(2): 343-351, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26884378

RESUMO

To study agreement in cardiac index (CI), systemic vascular resistance index (Systemic VRI) and stroke volume variation (SV variation) between the FloTrac/Vigileo at radial and femoral arterial cannulation sites, and pulmonary artery catheter (PAC) thermodilution, in patients undergoing orthotopic liver transplantation. A prospective observational study of 25 adult patients with liver failure. Radial and femoral arteries were cannulated with standardised FloTrac/Vigileo arterial transducer kits and a PAC was inserted. CI, SV variation and Systemic VRI were measured four times (30 min after induction of anesthesia, 30 min after portal vein clamping, 30 min after graft reperfusion, 30 min after commencement of bile duct anastomosis). The bias, precision, limits of agreement (LOA) and percentage errors were calculated using Bland-Altman statistics to compare measurements from radial and femoral arterial cannulation sites and PAC thermodilution. Neither radial nor femoral CI achieved acceptable agreement with PAC CI [radial to PAC bias (SD) 1.17 (1.49) L/min/m2, percentage error 64.40 %], [femoral to PAC bias (SD) -0.71 (1.81) L/min/m2, percentage error 74.20 %]. Agreement between radial and femoral sites for CI [mean difference (SD) -0.43 (1.51) L/min/m2, percentage error 70.40 %] and Systemic VRI [mean difference (SD) 0.03 (4.17) LOA ±8.17 mmHg min m2/L] were also unacceptable. Agreement in SV variation between radial and femoral measurement sites approached a clinically acceptable threshold [mean difference (SD) 0.68 (2.44) %), LOA ±4.78 %]. FloTrac/Vigileo CI cannot substitute for PAC thermodilution CI, regardless of measurement site. SV variation measurements may be interchangeable between radial and femoral sites for determining fluid responsiveness.


Assuntos
Hemodinâmica , Transplante de Fígado/métodos , Monitorização Intraoperatória/métodos , Termodiluição/métodos , Adulto , Anastomose Cirúrgica , Ductos Biliares/cirurgia , Pressão Sanguínea , Débito Cardíaco , Cateterismo , Feminino , Artéria Femoral/patologia , Fêmur/cirurgia , Humanos , Falência Hepática/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Artéria Pulmonar , Artéria Radial/patologia , Reprodutibilidade dos Testes , Fatores de Tempo
8.
BMC Anesthesiol ; 14: 35, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24839398

RESUMO

BACKGROUND: There is limited information on the impact on perioperative fluid intervention on complications and length of hospital stay following pancreaticoduodenectomy. Therefore, we conducted a detailed analysis of fluid intervention in patients undergoing pancreaticoduodenectomy at a university teaching hospital to test the hypothesis that a restrictive intravenous fluid regime and/or a neutral or negative cumulative fluid balance, would impact on perioperative complications and length of hospital stay. METHODS: We retrospectively obtained demographic, operative details, detailed fluid prescription, complications and outcomes data for 150 consecutive patients undergoing pancreaticoduodenectomy in a university teaching hospital. Prognostic predictors for length of hospital stay and complications were determined. RESULTS: One hundred and fifty consecutive patients undergoing pancreaticoduodenectomy were evaluated between 2006 and 2012. The majority of patients were, middle-aged, overweight and ASA class III. Postoperative complications were frequent and occurred in 86 patients (57%). The majority of complications were graded as Clavien-Dindo Class 2 and 3. Postoperative pancreatic fistula occurred in 13 patients (9%), and delayed gastric emptying occurred in 25 patients (17%). Other postoperative surgical complications included sepsis (22%), bile leak (4%), and postoperative bleeding (2%). Serious medical complications included pulmonary edema (6%), myocardial infarction (8%), cardiac arrhythmias (13%), respiratory failure (8%), and renal failure (7%). Patients with complications received a higher median volume of intravenous therapy and had higher cumulative positive fluid balances. Postoperative length of stay was significantly longer in patients with complications (median 25 days vs. 10 days; p < 0.001). After adjustment for covariates, a fluid balance of less than 1 litre on postoperative day 1 and surgeon caseloads were associated with the development of complications. CONCLUSIONS: In the context of pancreaticoduodenectomy, restrictive perioperative fluid intervention and negative cumulative fluid balance were associated with fewer complications and shorter length of hospital stay. These findings provide good opportunities to evaluate strategies aimed at improving perioperative care.


Assuntos
Hidratação/métodos , Tempo de Internação/estatística & dados numéricos , Pancreaticoduodenectomia/métodos , Complicações Pós-Operatórias/epidemiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Hospitais Universitários , Humanos , Masculino , Pessoa de Meia-Idade , Sobrepeso/epidemiologia , Fístula Pancreática/epidemiologia , Fístula Pancreática/etiologia , Prognóstico , Estudos Retrospectivos , Adulto Jovem
9.
Cureus ; 15(3): e36661, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37102021

RESUMO

Parkinson's disease (PD) is a complex neurodegenerative disorder with heterogeneous clinical presentations. Given the ambiguity of its overlapping symptomatology and concomitant atypical motor and neuropsychological symptoms its early diagnosis is clinically challenging. It is often missed since low mood, anhedonia, lack of motivation, and psychomotor retardation are commonly reported in individuals with PD. When alexithymia is the predominant symptom, the knowledge to discriminate between apathy, anhedonia, and alexithymia is critical to avoid misdiagnosis.

10.
World J Gastrointest Endosc ; 14(12): 777-788, 2022 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-36567821

RESUMO

BACKGROUND: Anaesthetic care during upper gastrointestinal (GI) endoscopy has the unique challenge of maintaining ventilation and oxygenation via a shared upper airway. Supplemental oxygen is recommended by international society guidelines, however, the optimal route or rate of oxygen delivery is not known. Various oxygen delivery devices have been investigated to improve oxygenation during upper GI endoscopy, however, these are limited by commercial availability, costs and in some cases, the expertise required for insertion. Anecdotally at our centre, higher flows of supplemental oxygen can safely be delivered via an oxygenating mouthguard routinely used during upper GI endoscopic procedures. AIM: To assess the incidence of hypoxaemia (SpO2 < 90%) in patients undergoing upper GI endoscopy receiving supplemental oxygen using an oxygenating mouthguard at 20 L/min flow compared to standard nasal cannula (SNC) at 2 L/min flow. METHODS: A single centre, prospective, randomised clinical trial at two sites of an Australian tertiary hospital between October 2020 and September 2021 was conducted. Patients undergoing elective upper gastrointestinal endoscopy under deep sedation were randomised to receive supplemental oxygen via high-flow via oxygenating mouthguard (HFMG) at 20 L/min flow or SNC at 2 L/min flow. The primary outcome was the incidence of hypoxaemia of any duration measured by pulse oximetry. Intraprocedural-related, procedural-related, and sedation-related adverse events and patient-reported outcomes were also recorded. RESULTS: Three hundred patients were randomised. Eight patients were excluded after randomisation. 292 patients were included in the intention-to-treat analysis. The incidence of hypoxaemia was significantly reduced in those allocated HFMG. Six patients (4.4%) allocated to HFMG experienced an episode of hypoxaemia, compared to thirty-four (22.1%) patients allocated to SNC (P value < 0.001). No significant difference was observed in the rates of adverse events or patient-reported outcome measures. CONCLUSION: The use of HFMG offers a novel approach to reducing the incidence of hypoxaemia during short upper gastrointestinal endoscopic procedures in low-risk patients undergoing deep sedation.

11.
BMJ Open ; 10(2): e029159, 2020 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-32066598

RESUMO

OBJECTIVES: The effects of hypercapnia on regional cerebral oxygen saturation (rSO2) during surgery are unclear. We conducted a randomised controlled trial to investigate the relationship between mild hypercapnia and rSO2. We hypothesised that, compared with targeted normocapnia (TN), targeted mild hypercapnia (TMH) during major surgery would increase rSO2. DESIGN: A prospective, randomised, controlled trial in adult participants undergoing elective major surgery. SETTING: A single tertiary centre in Heidelberg, Victoria, Australia. PARTICIPANTS: 40 participants were randomised to either a TMH or TN group (20 to each). INTERVENTIONS: TMH (partial pressure of carbon dioxide in arterial blood, PaCO2, 45-55 mm Hg) or TN (PaCO2 35-40 mm Hg) was delivered via controlled ventilation throughout surgery. PRIMARY AND SECONDARY OUTCOME MEASURES: The primary endpoint was the absolute difference between the two groups in percentage change in rSO2 from baseline to completion of surgery. Secondary endpoints included intraoperative pH, bicarbonate concentration, base excess, serum potassium concentration, incidence of postoperative delirium and length of stay (LOS) in hospital. RESULTS: The absolute difference between the two groups in percentage change in rSO2 from the baseline to the completion of surgery was 19.0% higher in both hemispheres with TMH (p<0.001). On both sides, the percentage change in rSO2 was greater in the TMH group than the TN group throughout the duration of surgery. The difference between the groups became more noticeable over time. Furthermore, postoperative delirium was higher in the TN group (risk difference 0.3, 95% CI 0.1 to 0.5, p=0.02). LOS was similar between groups (5 days vs 5 days; p=0.99). CONCLUSION: TMH was associated with a stable increase in rSO2 from the baseline, while TN was associated with a decrease in rSO2 in both hemispheres in patients undergoing major surgery. This resulted in a clear separation of percentage change in rSO2 from the baseline between TMH and TN over time. Our findings provide the rationale for larger studies on TMH during surgery. TRIAL REGISTRATION NUMBER: The Australian New Zealand Clinical Trials Registry (ACTRN12616000320459).


Assuntos
Gasometria/métodos , Encéfalo , Dióxido de Carbono/análise , Delírio , Hipercapnia , Cuidados Intraoperatórios/métodos , Oxigênio/análise , Complicações Cognitivas Pós-Operatórias , Respiração Artificial/métodos , Procedimentos Cirúrgicos Operatórios , Encéfalo/irrigação sanguínea , Encéfalo/fisiologia , Circulação Cerebrovascular/fisiologia , Delírio/diagnóstico , Delírio/etiologia , Delírio/prevenção & controle , Feminino , Humanos , Hipercapnia/sangue , Hipercapnia/diagnóstico , Hipercapnia/metabolismo , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Consumo de Oxigênio , Complicações Cognitivas Pós-Operatórias/etiologia , Complicações Cognitivas Pós-Operatórias/prevenção & controle , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Procedimentos Cirúrgicos Operatórios/efeitos adversos , Procedimentos Cirúrgicos Operatórios/métodos
12.
Ann Med Surg (Lond) ; 55: 111-118, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32477508

RESUMO

BACKGROUND: Hyperkalemia is a common cause of arrhythmias in patients undergoing liver transplantation. We examined the pattern of change of potassium levels during and immediately after reperfusion of the donor liver. MATERIALS AND METHODS: Potassium levels of 30 consecutive adult patients undergoing cadaveric liver transplantation were assessed before and after liver reperfusion. Changes in potassium levels over 13 predefined timepoints were analyzed. Primary aim: to describe the pattern of change of potassium levels during the reperfusion period. Correlation between changes in potassium levels during reperfusion and a-priori variables were investigated. RESULTS: Baseline median (IQR) potassium levels were 4.1 (3.8:4.5) mmol/L. Thirteen patients (43%) developed hyperkalemia, 10 (33%) of whom developed severe hyperkalemia. Potassium levels peaked at 80 s post reperfusion, plateaued until 2 min, before returning toward baseline values at 5 min. There was a strong association between pre-reperfusion/baseline potassium levels and peak potassium values during reperfusion (95%CI: 0.26 to 0.77, p < 0.001). A baseline potassium level of 4.45 mmol/L was a good predictor of reperfusion hyperkalemia with a sensitivity of 69.2% and specificity of 94.1% (AUC = 0.894, 95%CI: 0.779 to 1.000, p < 0.001). CONCLUSION: Hyperkalemia during cadaveric liver transplantation is common affecting almost 1 in 2 patients during reperfusion. During reperfusion potassium levels peaked within 2 min and over a third of patients developed severe hyperkalemia. Higher peak potassium levels correlated strongly with higher pre-reperfusion potassium values. These findings guide clinicians with timing of sampling of blood to check for hyperkalemia and identify modifiable factors associated with the development of hyperkalemia.

13.
Anaesth Intensive Care ; 48(3): 213-220, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32483998

RESUMO

The oxygen concentration (FiO2) and arterial oxygen tension (PaO2) delivered in patients undergoing major surgery is poorly understood. We aimed to assess current practice with regard to the delivered FiO2 and the resulting PaO2 in patients undergoing major surgery. We performed a retrospective cohort study in a tertiary hospital. Data were collected prospectively as part of a larger randomised controlled trial but were analysed retrospectively. Patients were included if receiving controlled mandatory ventilation and arterial line monitoring. Anaesthetists determined the FiO2 and the oxygenation saturation (SpO2) targets. An arterial blood gas (ABG) was obtained 15-20 minutes after induction of anaesthesia, immediately before the emergence phase of anaesthesia and 15 minutes after arrival in the post-anaesthesia care unit (PACU). We defined hyperoxaemia as a PaO2 of >150 mmHg and included a further threshold of PaO2 >200 mmHg. We studied 373 patients. The median (interquartile range (IQR)) lowest intraoperative FiO2 and SpO2 values were 0.45 (IQR 0.4-0.5) and 97% (IQR 96-98%), respectively, with a median PaO2 on the first and second ABG of 237 mmHg (IQR 171-291 mmHg) and 189 mmHg (IQR 145-239 mmHg), respectively. In the PACU, the median lowest oxygen flow rate was 6 L/min (IQR 3-6 L/min), and the PaO2 was 158 mmHg (IQR 120-192 mmHg). Hyperoxaemia occurred in 82%, 73% and 54% of participants on the first and second intraoperative and postoperative ABGs respectively. A PaO2 of >200 mmHg occurred in 64%, 41% and 21% of these blood gases, respectively. In an Australian tertiary hospital, a liberal approach to FiO2 and PaO2 was most common and resulted in a high incidence of perioperative hyperoxaemia.


Assuntos
Anestesia , Hiperóxia , Oxigênio , Complicações Pós-Operatórias , Austrália , Gasometria , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Retrospectivos
14.
Anesth Pain Med ; 9(5): e97052, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31903338

RESUMO

BACKGROUND: Thoracic surgery often results in severe postoperative pain. Regional analgesia via surgically placed extrapleural local anaesthetic (LA) and continuous infusion (CI) is an effective technique, however usually requires supplemental opioid to achieve satisfactory patient analgesia. We hypothesized that high frequency, low background rate extrapleural programmed intermittent boluses (PIB) of LA by could achieve superior patient analgesia and reduced oral morphine equivalent daily dosage (OMEDD) requirements for up to 3 days after thoracic surgery vs. CI. METHODS: We retrospectively analysed data from 84 adult patients receiving extrapleural analgesia after thoracic surgery in a single tertiary teaching hospital. The primary outcome measure was the effect of PIB vs. CI on maximum daily 11-point numerical rating scale (NRS-11) ratings as determined by multivariate linear regression analysis, corrected for OMEDD use, total daily LA dose, surgery type, age, opioid type, and use of ketamine analgesia. Secondary outcome measures were the effect on OMEDD use, the effect of total 'rescue' LA boluses, and univariate analyses of the above outcomes and variables. RESULTS: PIB on day 0, and a higher proportion of LA given as rescue boluses on day 1 were associated with reduced maximum NRS-11 ratings [standardized/ [unstandardized] beta coefficient -0.34/ [-0.92 NRS-11 if PIB] (P = 0.007); and -0.26/ [-0.029 NRS-11 per mg/kg extrapleural ropivacaine] (P = 0.03)], respectively. Only patient age was associated with reduced OMEDD use [day 0: -0.58/ [-4.4 OMEDDs per year of age] (P ≤ 0.005); day 1: -0.49/ [-3.56 OMEDDs per year of age] (P ≤ 0.005); day 2: -0.32/ [-1.9 OMEDDs per year of age] (P = 0.04)]. OMEDD use on day 2, however, was associated with slightly higher maximum NRS-11 ratings [+0.28/ +0.006 NRS-11 per mg OMEDD (P = 0.036)]. On univariate analysis, PIB patients achieved the largest difference in OMEDD use [-98 mg (95% CI -73 to -123 mg)] and NRS-11 ratings [-1.1 (-0.4 to -1.8)] against CI patients on day 3. CONCLUSIONS: Use of high frequency, low background rate PIB extrapleural LA after thoracic surgery appears to have a modest beneficial effect on acute pain, but not OMEDD use, over CI when adjusted for patient, surgical and other analgesic factors after thoracic surgery. Further work is required to elucidate the potential magnitude of effect that extrapleural LA given by PIB over CI can achieve.

15.
Crit Care Resusc ; 21(4): 243-50, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31778630

RESUMO

BACKGROUND: Mechanical ventilation is mandatory in patients undergoing general anaesthesia for major surgery. Tidal volumes higher than 10 mL/kg of predicted body weight have been advocated for intraoperative ventilation, but recent evidence suggests that low tidal volumes may benefit surgical patients. To date, the impact of low tidal volume compared with conventional tidal volume during surgery has only been assessed in clinical trials that also combine different levels of positive end-expiratory pressure (PEEP) in each arm. We aimed to assess the impact of low tidal volume compared with conventional tidal volume during general anaesthesia for surgery on the incidence of postoperative respiratory complications in adult patients receiving moderate levels of PEEP. STUDY DESIGN AND METHODS: Single-centre, two-arm, randomised clinical trial. In total, 1240 adult patients older than 40 years scheduled for at least 2 hours of surgery under general anaesthesia and routinely monitored with an arterial line were included. Patients were ventilated intraoperatively with a moderate level of PEEP (5 cmH2O) and randomly assigned to tidal volume of 6 mL/kg predicted body weight (low tidal volume) or 10 mL/kg predicted body weight (conventional tidal volume in Australia). MAIN OUTCOME MEASURE: The primary outcome is the occurrence of postoperative respiratory complications, recorded as a composite endpoint of adverse respiratory events during the first 7 postoperative days. RESULTS AND CONCLUSIONS: This is the first well powered study comparing the effect of low tidal volume ventilation versus high tidal volume ventilation during surgery on the incidence of postoperative respiratory complications in adult patients receiving moderate levels of PEEP. TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry (ACTRN12614000790640).


Assuntos
Anestesia Geral , Respiração com Pressão Positiva , Volume de Ventilação Pulmonar/efeitos dos fármacos , Adulto , Anestesia Geral/efeitos adversos , Austrália , Humanos , Respiração com Pressão Positiva/efeitos adversos , Ensaios Clínicos Controlados Aleatórios como Assunto , Respiração Artificial , Procedimentos Cirúrgicos Operatórios/efeitos adversos , Procedimentos Cirúrgicos Operatórios/métodos , Volume de Ventilação Pulmonar/fisiologia
16.
Transplant Direct ; 4(4): e358, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29707629

RESUMO

BACKGROUND: The avoidance of hypothermia is vital during prolonged and open surgery to improve patient outcomes. Hypothermia is particularly common during orthotopic liver transplantation (OLT) and associated with undesirable physiological effects that can adversely impact on perioperative morbidity. The KanMed WarmCloud (Bromma, Sweden) is a revolutionary, closed-loop, warm-air heating mattress developed to maintain normothermia and prevent pressure sores during major surgery. The clinical effectiveness of the WarmCloud device during OLT is unknown. Therefore, we conducted a randomized controlled trial to determine whether the WarmCloud device reduces hypothermia and prevents pressure injuries compared with the Bair Hugger underbody warming device. METHODS: Patients were randomly allocated to receive either the WarmCloud or Bair Hugger warming device. Both groups also received other routine standardized multimodal thermoregulatory strategies. Temperatures were recorded by nasopharyngeal temperature probe at set time points during surgery. The primary endpoint was nasopharyngeal temperature recorded 5 minutes before reperfusion. Secondary endpoints included changes in temperature over the predefined intraoperative time points, number of patients whose nadir temperature was below 35.5°C and the development of pressure injuries during surgery. RESULTS: Twenty-six patients were recruited with 13 patients randomized to each group. One patient from the WarmCloud group was excluded because of a protocol violation. Baseline characteristics were similar. The mean (standard deviation) temperature before reperfusion was 36.0°C (0.7) in the WarmCloud group versus 36.3°C (0.6) in the Bairhugger group (P = 0.25). There were no statistical differences between the groups for any of the secondary endpoints. CONCLUSIONS: When combined with standardized multimodal thermoregulatory strategies, the WarmCloud device does not reduce hypothermia compared with the Bair Hugger device in patients undergoing OLT.

17.
Crit Care Resusc ; 17(2): 101-7, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26017127

RESUMO

OBJECTIVE: To study agreement between radial and femoral arterial pressure measurements in orthotopic liver transplantation (OLTx) surgery to determine whether arterial cannulation sites are interchangeable. DESIGN, SETTING AND PARTICIPANTS: Prospective observational study of 25 patients undergoing OLTx surgery. METHODS: Radial and femoral arteries were cannulated with standardised arterial line kits. Radial and femoral mean arterial pressure (MAP), systolic arterial pressure (SAP), diastolic arterial pressure (DAP) and pulse pressure (PP) were measured at four time points (30 minutes after induction of anaesthesia, 30 minutes after the start of the anhepatic phase, 30 minutes after liver graft reperfusion and 30 minutes after the start of bile duct anastomosis). MAIN OUTCOME MEASURES: The bias, precision and limits of agreement between radial and femoral arterial pressures were calculated in accordance with Bland-Altman statistics. RESULTS: Radial-femoral differences in MAP (mean difference, 4.8 mmHg [SD, 4.5 mmHg]), limits of agreement (- 13.6 and 8.8, P < 0.001) and DAP showed clinically acceptable agreement between measurement sites across all time points. However, clinically significant differences between radial and femoral SAPs (mean difference, - 14.9 mmHg [SD, 24.8 mmHg]) and limits of agreement (- 63.5 and 33.7, P < 0.001) occurred overall. This difference started after portal vein clamping and remained significant throughout the remainder of the operation. CONCLUSION: Radial artery SAP underestimates femoral artery measurements significantly but unpredictably. As femoral measurement is more likely to reflect central arterial pressure, radial SAP measurement is not reliable in adults undergoing OLTx.


Assuntos
Pressão Arterial/fisiologia , Artéria Femoral/fisiopatologia , Falência Hepática/fisiopatologia , Falência Hepática/cirurgia , Transplante de Fígado , Artéria Radial/fisiopatologia , Adulto , Determinação da Pressão Arterial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória , Estudos Prospectivos , Reprodutibilidade dos Testes
19.
Hum Factors ; 45(2): 202-17, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14529194

RESUMO

We present a technique for team design based on cognitive work analysis (CWA). We first develop a rationale for this technique by discussing the limitations of conventional approaches for team design in light of the special characteristics of first-of-a-kind, complex systems. We then introduce the CWA-based technique for team design and provide a case study of how we used this technique to design a team for a first-of-a-kind, complex military system during the early stages of its development. In addition to illustrating the CWA-based technique by example, the case study allows us to evaluate the technique. This case study demonstrates that the CWA-based technique for team design is both feasible and useful, although empirical validation of the technique is still necessary. Applications of this work include the design of teams for first-of-a-kind, complex systems in military, medical, and industrial domains.


Assuntos
Cognição , Processos Grupais , Equipes de Administração Institucional , Austrália , Humanos , Militares/psicologia , Estudos de Casos Organizacionais , Análise de Sistemas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA