Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Chromatogr B Analyt Technol Biomed Life Sci ; 862(1-2): 132-9, 2008 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-18162446

RESUMO

We describe a liquid chromatography-tandem mass spectrometric method (LC-MS/MS) for levocetirizine quantification (I) in human plasma. Sample preparation was made using a fexofenadine (II) addition as internal standard (IS), liquid-liquid extraction using cold dichloromethane, and dissolving the final extract in acetonitrile. I and II (IS) were injected in a C18 column and the mobile phase composed of acetonitrile:water:formic acid (80.00:19.90:0.10, v/v/v) and monitored using positive electrospray source with tandem mass spectrometry analyses. The selected reaction monitoring (SRM) was set using precursor ion and product ion combinations of m/z 389>201 for I and m/z 502>467 for II. The limit of quantification and the dynamic range achieved were 0.5ng/mL and 0.5-500.0ng/mL. Validation results on linearity, specificity, accuracy, precision and stability, as well as its application to the analysis of plasma samples taken up to 48h after oral administration of 5mg of levocetirizine dichloridrate in healthy volunteers demonstrate its applicability to bioavailability studies.


Assuntos
Cetirizina/sangue , Antagonistas dos Receptores Histamínicos H1/sangue , Piperazinas/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Adolescente , Adulto , Disponibilidade Biológica , Cetirizina/farmacocinética , Estudos Cross-Over , Antagonistas dos Receptores Histamínicos H1/farmacocinética , Humanos , Pessoa de Meia-Idade , Piperazinas/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Equivalência Terapêutica
2.
Artigo em Inglês | MEDLINE | ID: mdl-11824393

RESUMO

Multidimensional HPLC is a powerful tool for the analysis of samples of a high degree of complexity. This work reports the use of multidimensional HPLC by coupling a RAM column with a chiral polysaccharide column to the analysis of Pantoprazole in human plasma by direct injection. The enantiomers from the plasma samples were separated with high resolution on a tris(3,5-dimethoxyphenylcarbamate) of amylose phase after clean-up by a RAM BSA octyl column. Water was used as solvent for the first 5 min in a flow-rate of 1.0 ml/min for the elution of the plasmatic proteins and then acetonitrile-water (35:65 v/v) for the transfer and analysis of pantoprazole enantiomers, which were detected by UV at 285 nm. Analysis time was 28 min with no time spent on sample preparation. A good linear relationship was obtained in the concentration range of 0.20 to 1.5 microg/ml for each enantiomer. Inter and intra-day precision and accuracy were determined by one low (0.24 microg/ml), one medium (0.70 microg/ml) and one high (1.3 microg/ml) plasma concentration and gave a C.V. varying from 1.80 to 8.43% and accuracy from 86 to 92%. Recoveries of pantoprazole enantiomers were in the range of 93.7-101.2%. The validated method was applied to the analysis of the plasma samples obtained from ten Brazilian volunteers who received an 80 mg oral dose of racemic pantoprazole and was able to quantify the enantiomers of pantoprazole in all clinical samples analyzed.


Assuntos
Benzimidazóis/sangue , Cromatografia Líquida de Alta Pressão/métodos , Inibidores Enzimáticos/sangue , Sulfóxidos/sangue , 2-Piridinilmetilsulfinilbenzimidazóis , Benzimidazóis/farmacocinética , Calibragem , Inibidores Enzimáticos/farmacocinética , Humanos , Omeprazol/análogos & derivados , Pantoprazol , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estereoisomerismo , Sulfóxidos/farmacocinética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA