Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 103
Filtrar
1.
J Prosthet Dent ; 2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-38007292

RESUMO

STATEMENT OF PROBLEM: The etiology and diagnosis of noncarious cervical lesions (NCCLs) remain poorly understood. PURPOSE: The purpose of this clinical study was to examine NCCL progression in an existing group of participants, establish the incidence of new NCCLs in a 25-year follow-up study, and relate them to possible risk factors, including occlusal factors. MATERIAL AND METHODS: Thirty-three participants who had completed a questionnaire about their habits, diet, and personal information were evaluated in this observational retrospective study. Impressions were made, and casts from 3 time periods (Phase I in 1996, Phase II in 1999, and Phase III in 2021) were scanned to obtain digital casts. The casts were then evaluated in a 3-dimensional analysis software program (Geomagic Control; 3D Systems) to establish digital comparisons between NCCLs and occlusal wear. Furthermore, data from an occlusal analysis device (T-Scan; Tekscan) collected in Phase I was used to analyze occlusal interferences relating to the progression of NCCLs. The statistical analysis applied nonparametric tests, followed by the assessment of the association between NCCLs and risk factors, including occlusal wear, through binary logistic regression (α=.05). RESULTS: At the end of Phase III, 7 new individuals with NCCLs were detected compared with Phase II. The median percentage progression of NCCLs per participant was 0.0% in Phase I, 7.1% in Phase II, and 35.7% in Phase III (P<.005). Occlusal wear in Phase I was associated with 5.02 times the occurrence of NCCLs in Phase III; occlusal wear in Phase II was associated with 4.73 times the occurrence of NCCLs in Phase III; and occlusal wear in Phase III was associated with 1.94 times the occurrence of NCCLs in Phase III (P<.001). Occlusal interference in border movements of the mandible was associated with a 3.55 times greater chance of presenting NCCLs in Phase III (P<.001). Additionally, statistically significant risk factors for the presence of NCCLs in Phase III were an acidic diet (P=.043) and alcohol consumption (P=.021). CONCLUSIONS: The 25-year data showed an association between NCCLs and specific risk factors, including occlusal wear and occlusal interferences.

2.
J Stroke Cerebrovasc Dis ; 30(8): 105887, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34102554

RESUMO

OBJECTIVES: Atrial fibrillation (AF) is associated with high risk of dementia and brain atrophy in stroke-free patients, but the mechanisms underlying this association remain unclear. We aimed to examine the brain volume and connectivity of paramount cognitive brain networks in stroke-free patients with AF without dementia. MATERIALS AND METHODS: Twenty-six stroke-free patients with AF and 26 age and sex-matched subjects without AF were submitted to a 3-tesla brain structural and functional MRI. An extensive clinical evaluation excluded stroke, dementia, low cardiac output, carotid stenosis and metabolic diseases without optimal therapy. We used CHA2DS2-VASc score to classify the cardiovascular risk factor burden and a broad neuropsychological battery to assess the cognitive performance. Voxel based morphometry analysis of. structural MRI defined whole-brain gray and white matter volumes. Finally, we used eco-plannar MRI images to compare the differences of functional connectivity of 7 large-scale resting-state networks between AF patients and controls. RESULTS: Taking into account the history of hypertension and heart failure, AF was associated to volume decrease of the right basal frontal lobe and right inferior cerebellum. Decreased connectivity of the ventral Default Mode Network (vDMN) was observed in the AF group. No disruption of connectivity was observed in the executive, visuospatial and salience networks. CONCLUSION: Individuals with AF without stroke or dementia have subtle reduction of gray and white matter, restricted to frontal areas and cerebellum. These patients show decreased vDMN connectivity, without other large-scale brain network disruption.


Assuntos
Fibrilação Atrial/complicações , Encéfalo/diagnóstico por imagem , Disfunção Cognitiva/etiologia , Neuroimagem Funcional , Imageamento por Ressonância Magnética , Rede Nervosa/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Atrofia , Encéfalo/fisiopatologia , Estudos de Casos e Controles , Cognição , Disfunção Cognitiva/diagnóstico , Disfunção Cognitiva/fisiopatologia , Disfunção Cognitiva/psicologia , Feminino , Humanos , Masculino , Testes de Estado Mental e Demência , Pessoa de Meia-Idade , Rede Nervosa/fisiopatologia , Testes Neuropsicológicos , Valor Preditivo dos Testes
3.
J Autism Dev Disord ; 50(7): 2320-2325, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29532353

RESUMO

This study investigated the psychometric properties of the Autism Mental Status Examination (AMSE) in a Brazilian sample of children and adolescents with autism spectrum disorder (ASD). A sample of 260 children and adolescents, comprising 56 (21.5%) females and 204 (78.5%) males, was assessed. The participants were submitted to both the childhood autism rating scale (CARS-BR) and the AMSE. The CARS-BR was used to estimate ASD severity and the cutoff point on the AMSE. Spearman's correlation test was employed to determine the correlation between the AMSE and CARS-BR scales. The cutoff values were calculated using the ROC (receiver operating characteristic) curve, identifying the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). The homogeneity of the items of the AMSE was determined using Cronbach´s alpha. The AMSE exhibited good internal consistency (0.74), sensitivity (0.91) and specificity (0.98); and high correlation with the CARS-BR (ρ = 0.91, p < 0.01). Preliminary results showed that the AMSE is a tool with good psychometric properties for ASD screening.


Assuntos
Transtorno do Espectro Autista/diagnóstico , Testes de Estado Mental e Demência/normas , Psicometria/normas , Adolescente , Brasil , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Sensibilidade e Especificidade
4.
Int J Prosthodont ; 33(6): 641-647, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33284906

RESUMO

PURPOSE: To three-dimensionally evaluate the internal fit at the implant-abutment interface of abutments fabricated with different workflows using a combination of the silicone replica technique and microcomputed tomography (µCT). MATERIALS AND METHODS: Thirty abutments were fabricated to restore internal-connection implants and were divided into three groups according to fabrication method: (1) full digital (abutment machined using CAD/CAM system); (2) Ti-Base (prefabricated standard Ti-Base abutments); and (3) UCLA (UCLA-type abutments) (n = 10/group). Linear and volume measurements were performed to assess the internal misfit using a silicone replica of the implant-abutment interface misfit area, which was three-dimensionally reconstructed after µCT. The internal discrepancies in three different regions of interest (Gapsuperior, Gapmarginal, and Gapcenter) were assessed. Data were statistically evaluated using ANOVA and Tukey test (P < .05). RESULTS: Ti-Base and UCLA abutments presented significantly lower misfit volume (0.49 mm3, 95% CI: ± 0.045 mm3 and 0.48 mm3, 95% CI: ± 0.045 mm3, respectively) and mean internal gap (25.20 µm, 95% CI: ± 3.14 µm and 27.97 µm, 95% CI: ± 3.14 µm, respectively) than the full digital group (0.70 mm3, 95% CI: ± 0.045 mm3; 34.90 µm, 95% CI: ± 3.14 µm) (P < .001), but did not differ from each other (P = .825). While Gapcenter was significantly higher in the full digital group (P < .001), Gapsuperior and Gapmarginal did not demonstrate significant differences among groups. All regions were statistically similar within groups, except for Gapcenter in the full digital group, which exhibited higher mean values compared to the other regions (P = .000). The 3D measurements for quantification of internal discrepancy were strongly associated with the 2D measurements. CONCLUSION: Ti-Base and UCLA abutments exhibited better internal fit at the implant-abutment interfaces compared to a fully digitalized workflow (CAD/CAM custom abutments).


Assuntos
Dente Suporte , Implantes Dentários , Desenho Assistido por Computador , Titânio , Microtomografia por Raio-X
5.
J Appl Oral Sci ; 27: e20180351, 2019 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-31365707

RESUMO

OBJECTIVE: Since the transmittance of ceramics can influence the degree of conversion (DC) of resin cements, ceramics composition and shade should be considered in the selection of resin cement. This in vitro study aimed to evaluate the effect of the transmittance of different composition, opacities and shades of ceramics on the degree of conversion of two dual-cured resin cements. METHODOLOGY: Sixty discs were prepared from low translucency (LT) and medium opacity (MO) lithium disilicate ceramic, and zirconia ceramic (Z). Each group was subdivided into 5 subgroups (n=4) in shades A2, A3.5, B2, C2 and D3. The transmittance measurement was performed in a spectrophotometer. The Variolink II and Rely X U200 resin cements were photoactivated by LED (1400 mW/cm2) for 40 s through the ceramic discs and without the discs (control group). The DC was measured with infrared FTIR spectroscopy, immediately after light activation. Data were analyzed with Kruskall-Wallis and one-way ANOVA, following post-hoc comparisons by Tukey test and Pearson's correlation test (P<0.05). RESULTS: LT ceramic exhibited higher transmittance values compared to MO and Z ceramics. LTA2 and LTB2 showed statistically higher transmittance values compared to MOA2, MOA3.5 and ZA3.5. For Variolink II, the ceramic interposition did not influence the DC, since there were no statistical differences between groups with ceramic interposition and the control group. For Rely X U200 cement, the interposition of some ceramics types/shades (LTA3.5, MOA2, MOA3.5 and ZA3.5) significantly decreased the DC values compared to control group. A positive correlation was found between the ceramic transmittance and DC values of both tested cements. Conclusions. The transmittance and DC values of the cements were influenced by composition and shades of the ceramics. The higher the transmittance of ceramics, the higher the DC values for both cements.


Assuntos
Porcelana Dentária/química , Cimentos de Resina/química , Zircônio/química , Análise de Variância , Lâmpadas de Polimerização Dentária , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Transição de Fase , Polimerização , Valores de Referência , Reprodutibilidade dos Testes , Espectrofotometria/métodos , Estatísticas não Paramétricas
6.
J Periodontol ; 78(1): 29-36, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17199536

RESUMO

BACKGROUND: In dentistry, investigations in the field of periodontics in individuals with cleft lip and palate are scarce, with few studies on the prevalence, incidence, extension, and severity of periodontal alterations and their treatment in adults. METHODS: This study analyzed the prevalence, extension, and severity of recessions and the relationship with some etiologic factors in 200 individuals with cleft lip and palate aged 13 to 56 years. Examination comprised measurements of gingival recession, amount of keratinized mucosa, frenum insertions, and tooth positioning in the dental arch. RESULTS: Analysis of the results revealed that the prevalence of recession was high, because 75% of individuals in the sample had at least one tooth with gingival recession; 100% of individuals aged >43 years presented at least one recession, and most recessions were Miller Class I. The multiple linear regression demonstrated that recession is directly proportional to age (i.e., it increases with age); concerning the amount of keratinized mucosa, the proportion is inverse (i.e., the larger the recession, the smaller the amount of mucosa); and gingival inflammation also presented a positive correlation. CONCLUSIONS: Gingival recessions are caused by many etiologic factors, which usually act in combination. Thus, all factors causing recession should be analyzed so that planning and treatment of this clinical condition may be established, for achievement of optimal outcomes.


Assuntos
Fenda Labial/complicações , Fissura Palatina/complicações , Retração Gengival/etiologia , Adolescente , Adulto , Distribuição por Idade , Brasil/epidemiologia , Estudos Transversais , Feminino , Retração Gengival/epidemiologia , Humanos , Incidência , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Índice Periodontal , Prevalência , Fatores de Risco , Distribuição por Sexo , Estatísticas não Paramétricas
7.
Int Dent J ; 57(3): 153-60, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17695735

RESUMO

OBJECTIVE: To investigate the fracture strength and pattern of failure of teeth with weakened roots reconstructed by different procedures. METHODS: In an in vitro study root posts were placed in 50 endodontically treated canines, divided into 5 groups (n=10) as follows: cast metallic post; glass fibre post with smaller diameter than the root canal; glass fibre post with smaller diameter than the root canal + glass fibre strips; glass fibre post with smaller diameter than the root canal + accessory glass fibre posts; anatomical post (glass fibre post with smaller diameter than the root canal, relined with low viscosity composite resin). Posts were luted with resin cement and the coronal portion of posts was constructed with composite resin. Metallic crowns were cemented on the posts. Specimens were submitted to compressive load in a universal testing machine. Fracture strength values of each group were compared. RESULTS: Fracture strength values were for Groups 1-5 respectively: 1087.06; 745.69; 775.41; 920.64; 876.12kgf, with significant differences between Groups 1 and 2 and between Groups 1 and 3 (p<0.05). Observed patterns of fracture were: Group 1 - 100% of roots fractured; Groups 2 and 4 - variable fracture modes; Group 3 - 60% of fractures occurred in the cervical root third; Group 5 - 50% of failures occurred in the coronal portion of the post. CONCLUSIONS: The fracture strength of teeth with cast metallic posts, teeth with anatomical posts or teeth with glass fibre posts combined with accessory posts was similar. All teeth restored with cast metallic posts presented fractures and were unfavourable to maintenance of the remaining tooth structure. Teeth with fibre posts (Groups 2 to 5) presented variable fracture modes; however, the maximum percentage of unfavourable fractures was 30%.


Assuntos
Materiais Dentários/química , Cavidade Pulpar/fisiopatologia , Vidro/química , Técnica para Retentor Intrarradicular/instrumentação , Fraturas dos Dentes/fisiopatologia , Ligas de Cromo/química , Resinas Compostas/química , Força Compressiva , Coroas , Ligas Dentárias/química , Planejamento de Prótese Dentária , Análise do Estresse Dentário , Humanos , Teste de Materiais , Maleabilidade , Cimentos de Resina/química , Preparo de Canal Radicular/métodos , Estresse Mecânico , Propriedades de Superfície , Raiz Dentária/lesões , Raiz Dentária/fisiopatologia
8.
J Appl Oral Sci ; 25(6): 700-707, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29211292

RESUMO

OBJECTIVE: Due to increasing of aesthetic demand, ceramic crowns are widely used in different situations. However, to obtain long-term prognosis of restorations, a good conversion of resin cement is necessary. To evaluate the degree of conversion (DC) of one light-cure and two dual-cure resin cements under a simulated clinical cementation of ceramic crowns. MATERIAL AND METHODS: Prepared teeth were randomly split according to the ceramic's material, resin cement and curing protocol. The crowns were cemented as per manufacturer's directions and photoactivated either from occlusal suface only for 60 s; or from the buccal, occlusal and lingual surfaces, with an exposure time of 20 s on each aspect. After cementation, the specimens were stored in deionized water at 37°C for 7 days. Specimens were transversally sectioned from occlusal to cervical surfaces and the DC was determined along the cement line with three measurements taken and averaged from the buccal, lingual and approximal aspects using micro-Raman spectroscopy (Alpha 300R/WITec®). Data were analyzed by 3-way ANOVA and Tukey test at =5%. RESULTS: Statistical analysis showed significant differences among cements, curing protocols and ceramic type (p<0.001). The curing protocol 3x20 resulted in higher DC for all tested conditions; lower DC was observed for Zr ceramic crowns; Duolink resin cement culminated in higher DC regardless ceramic composition and curing protocol. CONCLUSION: The DC of resin cement layers was dependent on the curing protocol and type of ceramic.


Assuntos
Lâmpadas de Polimerização Dentária , Cimentos Dentários/química , Porcelana Dentária/química , Estética Dentária , Cimentos de Resina/química , Humanos , Teste de Materiais , Propriedades de Superfície
9.
Rev. CEFAC ; 24(5): e8122, 2022. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1422701

RESUMO

ABSTRACT Purpose: to measure the total time of mastication and oral phase of swallowing in healthy elderly people, considering different food consistency, the presence of natural teeth, and the type of prosthetic oral rehabilitation, as well to compare dental conditions and consistencies. Methods: a cross-sectional study with 57 healthy elderly people, aged between 60 and 82 years, divided into: dentate group (D) (n=15); and rehabilitated groups; PD: fixed or removable partial dentures in one or both arches (n=15); CRD: maxillary and mandibular complete removable dentures (n=15); ISCD: complete dentures - maxillary removable denture and mandibular implant-supported dentures (n=12). The duration time (seconds) of chewing and of the oral phase of swallowing was measured in the consistencies: solid (a roll slice), pudding (10 ml) and liquid (10 ml). Results: healthy dentate elderly subjects had the following intervals: liquid=1.07±0.35 s; pudding=3.48±1.76 s; and solid=27.88±7.11 s. Statistically significant differences were observed between the D and ISCD groups (p=0.0056) and between D and CRD (p=0.0056) for liquid. For all groups, there was a statistically significant increase between liquid and solid consistencies and between pasty and solid ones (p<0.001). Conclusions: the dentate elderly had shorter oral phase time of swallowing for liquids than the rehabilitated edentulous elderly, but not different from the elderly with partial dentures. Chewing and swallowing time for solid food was longer than that for the other consistencies, regardless of dental condition.


RESUMO Objetivo: mensurar o tempo total da mastigação e da fase oral da deglutição em idosos saudáveis, considerando diferentes consistências alimentares, a presença de dentes naturais e o tipo de reabilitação oral protética, bem como realizar comparação entre as condições dentárias e as consistências. Métodos: estudo transversal com 57 idosos saudáveis, entre 60 e 82 anos, distribuídos em grupo dentado (D) (n=15) e grupos reabilitados: próteses parciais fixas ou removíveis em uma ou ambas as arcadas (PP) (n=15); prótese total removível maxilar e mandibular (PTR) (n=15); prótese total - prótese removível superior e prótese implanto-suportada inferior (PTIS) (n=12). O tempo de duração (segundos) da mastigação e da fase oral da deglutição foi medido nas consistências: sólida (pão francês), pudim (10 ml) e líquida (10 ml). Resultados: idosos dentados saudáveis apresentaram os intervalos: líquido=1,07±0,35 s; pudim=3,48±1,76 s; e sólido=27,88±7,11 s. Foram observadas diferenças estatisticamente significativas entre os grupos D e PTIS (p=0,0056) e entre D e PTR (p=0,0056) para líquido. Para todos os grupos, houve aumento estatisticamente significante entre as consistências líquida e sólida e entre pastosa e sólida (p<0,001). Conclusões: idosos dentados apresentaram menor tempo de fase oral da deglutição para líquidos do que idosos edêntulos totais reabilitados, mas não diferente dos idosos com prótese parcial. O tempo de mastigação e deglutição do alimento sólido foi maior que o das demais consistências, independente da condição dentária.

10.
Estilos clín ; 26(3)2021. ilus
Artigo em Português | LILACS, INDEXPSI | ID: biblio-1438271

RESUMO

Mães de filhos com Transtorno do Espectro Autista (TEA) tendem a vivenciar diversos desafios na maternidade. Este estudo qualitativo tem como objetivo compreender as vivências maternas e as experiências com os primeiros indicadores de TEA. Seis mães com filhos diagnosticados com TEA responderam um questionário sociodemográfico e uma entrevista semiestruturada. Notou-se que mesmo antes do diagnóstico as mães percebiam que algo não ia bem com o bebê, havendo sobrecarga materna com os inúmeros cuidados que os filhos necessitam e que a rede de apoio é de extrema importância. Contudo, a intervenção precoce é relevante e pode contribuir de forma positiva com a relação mãe e bebê e sua subjetividade antes de um diagnóstico e o TEA implica em cuidados não somente com a criança, mas também ao seu cuidador principal


Las madres de niños con trastorno del espectro autista (TEA) tienden a experimentar varios desafíos en la maternidad. Este estudio cualitativo tiene como objetivo comprender las experiencias y vivencias maternas con los primeros indicadores de TEA. Seis madres con hijos diagnosticados de TEA respondieron un cuestionario sociodemográfico y una entrevista semiestructurada. Se notó que incluso antes del diagnóstico, las madres se dieron cuenta de que algo no iba bien con el bebé, con la sobrecarga materna, con los innumerables cuidados que los niños necesitan y que la red de apoyo es sumamente importante. Sin embargo, la intervención temprana es relevante y puede contribuir positivamente a la relación entre la madre y el bebé y su subjetividad antes de un diagnóstico y el TEA implica un cuidado no solo para el niño, sino también para su cuidador principal


Mothers whose children are in the Autism Spectrum Disorder (ASD) usually go through a variety of challenges in maternity. This qualitative research aims to comprehend the maternity experiences with the first signs of ASD. Six mothers which had their children diagnosed with ASD answered a sociodemographic questionnaire and a semi structured interview. It was eminent that even before the diagnosis the mothers could perceive that there was something different with their babies, how the need for the extra care that their babies demand is overwhelming and how important it is for them to have support. However, the early intervention is relevant and can contribute positively in the relationship between mother and child and in the mother ́s subjectivity before a diagnosis is given and ASD imply in taking care not only of the child but also of their main keeper


Les mères d'enfants atteints d'un Trouble du Spectre Autistique (TSA) ont tendance à éprouver plusieurs types de difficultés pendant la maternité. Cette étude qualitative vise à comprendre les expériences maternelles et les expériences avec les premiers indicateurs de TSA. Six mères d'enfants atteints de TSA ont répondu à un questionnaire sociodémographique et à un entretien semi-structuré. Il a été noté qu'avant même le diagnostic, les mères se rendaient compte que quelque chose n'allait pas bien avec le bébé. Elles font face à une surcharge maternelle avec d'innombrables soins à porter aux enfants. L'étude montre que le réseau de soutien est extrêmement important. Cependant, une intervention précoce est pertinente et peut contribuer positivement à la relation entre la mère et le bébé et leur subjectivité avant que le diagnostic soit réalisé. Le TSA implique une prise en charge non seulement de l'enfant, mais aussi de son principal soignant


Assuntos
Humanos , Masculino , Feminino , Pré-Escolar , Criança , Adulto , Pessoa de Meia-Idade , Intervenção Médica Precoce , Transtorno do Espectro Autista/psicologia , Relações Mãe-Filho/psicologia , Apoio Social , Cuidado da Criança , Pesquisa Qualitativa , Fatores Sociodemográficos
11.
J Am Dent Assoc ; 136(12): 1694-700, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16383052

RESUMO

BACKGROUND: The factors that induce the formation of noncarious lesions are not understood fully, particularly those that are related to occlusal aspects. The authors conducted a study to evaluate the prevalence of noncarious cervical lesions in adults and their association with occlusal aspects. METHODS: The authors examined 70 people (35 men and 35 women) aged 25 to 45 years to determine the presence and type of noncarious cervical lesions, wear facets, tooth contacts in maximal intercuspal position, and lateral and protrusive movements. The assessment involved a questionnaire and clinical examination. RESULTS: Among the teeth the authors evaluated, 17.23 percent had cervical lesions, 80.28 percent of which had wear facets (P < .01). The authors found a significant difference between the prevalence of noncarious lesions and the presence of wear facets (P = .0484). CONCLUSIONS: The authors found that cervical lesions were related significantly to wear facets. These findings strengthen evidence for the role of occlusal forces as an etiologic factor for noncarious lesions. CLINICAL IMPLICATIONS: The presence of wear facets should be considered in the treatment of noncarious cervical lesions.


Assuntos
Oclusão Dentária , Abrasão Dentária/epidemiologia , Atrito Dentário/epidemiologia , Colo do Dente/patologia , Erosão Dentária/epidemiologia , Adulto , Brasil/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Valores de Referência , Erosão Dentária/classificação
12.
J Appl Oral Sci ; 22(4): 287-93, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25141200

RESUMO

UNLABELLED: Composite resin and metallic posts are the materials most employed for reconstruction of teeth presenting partial or total destruction of crowns. Resin-based cements have been widely used for cementation of ceramic crowns. The success of cementation depends on the achievement of adequate cement curing. OBJECTIVES: To evaluate the microhardness of Variolink® II (Ivoclar Vivadent, Schaan, Liechtenstein), used for cementing ceramic crowns onto three different coronal substrate preparations (dentin, metal, and composite resin), after 7 days and 3 months of water storage. The evaluation was performed along the cement line in the cervical, medium and occlusal thirds on the buccal and lingual aspects, and on the occlusal surface. MATERIAL AND METHODS: Thirty molars were distributed in three groups (N=10) according to the type of coronal substrate: Group D- the prepared surfaces were kept in dentin; Groups M (metal) and R (resin)- the crowns were sectioned at the level of the cementoenamel junction and restored with metallic cast posts or resin build-up cores, respectively. The crowns were fabricated in ceramic IPS e.max® Press (Ivoclar Vivadent, Schaan, Liechtenstein) and luted with Variolink II. After 7 days of water storage, 5 specimens of each group were sectioned in buccolingual direction for microhardness measurements. The other specimens (N=5) were kept stored in deionized water at 37ºC for three months, followed by sectioning and microhardness measurements. RESULTS: Data were first analyzed by three-way ANOVA that did not reveal significant differences between thirds and occlusal surface (p=0.231). Two-way ANOVA showed significant effect of substrates (p<0.001) and the Tukey test revealed that microhardness was significantly lower when crowns were cemented on resin cores and tested after 7 days of water storage (p=0.007). CONCLUSION: The type of material employed for coronal reconstruction of preparations for prosthetic purposes may influence the cement properties.


Assuntos
Cimentação/métodos , Cerâmica/química , Coroas , Cimentos de Resina/química , Água/química , Análise de Variância , Testes de Dureza , Humanos , Teste de Materiais , Ilustração Médica , Valores de Referência , Reprodutibilidade dos Testes , Propriedades de Superfície , Fatores de Tempo
13.
J. appl. oral sci ; 27: e20180351, 2019. graf
Artigo em Inglês | LILACS, BBO | ID: biblio-1012511

RESUMO

Abstract Objective Since the transmittance of ceramics can influence the degree of conversion (DC) of resin cements, ceramics composition and shade should be considered in the selection of resin cement. This in vitro study aimed to evaluate the effect of the transmittance of different composition, opacities and shades of ceramics on the degree of conversion of two dual-cured resin cements. Methodology Sixty discs were prepared from low translucency (LT) and medium opacity (MO) lithium disilicate ceramic, and zirconia ceramic (Z). Each group was subdivided into 5 subgroups (n=4) in shades A2, A3.5, B2, C2 and D3. The transmittance measurement was performed in a spectrophotometer. The Variolink II and Rely X U200 resin cements were photoactivated by LED (1400 mW/cm2) for 40 s through the ceramic discs and without the discs (control group). The DC was measured with infrared FTIR spectroscopy, immediately after light activation. Data were analyzed with Kruskall-Wallis and one-way ANOVA, following post-hoc comparisons by Tukey test and Pearson's correlation test (P<0.05). Results LT ceramic exhibited higher transmittance values compared to MO and Z ceramics. LTA2 and LTB2 showed statistically higher transmittance values compared to MOA2, MOA3.5 and ZA3.5. For Variolink II, the ceramic interposition did not influence the DC, since there were no statistical differences between groups with ceramic interposition and the control group. For Rely X U200 cement, the interposition of some ceramics types/shades (LTA3.5, MOA2, MOA3.5 and ZA3.5) significantly decreased the DC values compared to control group. A positive correlation was found between the ceramic transmittance and DC values of both tested cements. Conclusions. The transmittance and DC values of the cements were influenced by composition and shades of the ceramics. The higher the transmittance of ceramics, the higher the DC values for both cements.


Assuntos
Zircônio/química , Cimentos de Resina/química , Porcelana Dentária/química , Valores de Referência , Espectrofotometria/métodos , Teste de Materiais , Reprodutibilidade dos Testes , Análise de Variância , Estatísticas não Paramétricas , Transição de Fase , Cura Luminosa de Adesivos Dentários , Lâmpadas de Polimerização Dentária , Polimerização
14.
Biosci. j. (Online) ; 34(1): 260-267, jan./feb. 2018.
Artigo em Inglês | LILACS | ID: biblio-966635

RESUMO

Among the ceramic materials used in dentistry, Zirconia presents the ideal opacity for cases where the clinical challenge is to neutralize the difference in the colors of the substrates. The "ceramic steel", so called by some authors, guarantees to Zirconia resistance and hardness similar to a metal, but with aesthetic advantages superior to the metal-ceramic restorations, which can exhibit exposure of the metal band over time. This article describes a complex rehabilitation treatment involving dental elements with different substrates: 11 - vital tooth with large crown damage; 21 ­ endodontically treated tooth and cast metal core; 22 - Morse taper implant. The selection of a completely zirconia-based ceramic system allowed masking the different conditions of substrates, so achieving the esthetic expectations. Moreover, considering the patient's high smile line, excellent gingival esthetics was obtained with an internal connection Morse taper implant associated with an individualized anatomic abutment.


Dentre os materiais cerâmicos utilizados na Odontologia, a Zircônia apresenta a opacidade ideal para os casos em que o desafio clinico é neutralizar a diferença nas cores dos substratos. O "aço cerâmico", assim chamado por alguns autores, garante à Zircônia resistência e dureza semelhantes a um metal, mas com vantagens estéticas superiores às restaurações metalocerâmicas, as quais podem apresentar exposição da cinta metálica ao longo do tempo. Este artigo descreve um tratamento reabilitador complexo, envolvendo elementos dentários com diferentes substratos: 11 - dente vital com ampla destruição coronária; 21 - dente com tratamento endodôntico e núcleo metálico fundido; 22 ­ ausente, reabilitado com implante do tipo cone morse. A seleção do sistema totalmente cerâmico à base de zircônia, permitiu mascarar as diferentes condições dos substratos atingindo as expectativas estéticas. Além disso, diante do sorriso alto gengivoso presente neste caso, a excelência na estética gengival foi obtida utilizando implante com conexão interna do tipo cone morse associado a um pilar anatômico individualizado.


Assuntos
Dente , Implantes Dentários , Ligas Metalo-Cerâmicas , Estética Dentária , Gengiva
15.
J Appl Oral Sci ; 20(5): 556-62, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23138743

RESUMO

OBJECTIVES: To determine the micro-hardness profile of two dual cure resin cements (RelyX-U100, 3M-eSPe and Panavia F 2.0, Kuraray) used for cementing fiberre inforced resin posts (Fibrekor-Jeneric Pentron) under three different curing protocols and two water storage times. MATERIAL AND METHODS: Sixty 16 mm long bovine incisor roots were endodontically treated and prepared for cementation of the Fibrekor posts. The cements were mixed as instructed, dispensed in the canal, the posts were seated and the curing performed as follows: (a) no light activation; (b) light-activation immediately after seating the post, and; (c) light-activation delayed 5 minutes after seating the post. The teeth were stored in water and retrieved for analysis after 7 days and 3 months. The roots were longitudinally sectioned and the microhardness was determined at the cervical, middle and apical regions along the cement line. The data was analyzed by the three-way ANOVA test (curing mode, storage time and thirds) for each cement. The Tukey test was used for the post-hoc analysis. RESULTS: Light-activation resulted in a significant increase in the microhardness. This was more evident for the cervical region and for the Panavia cement. Storage in water for 3 months caused a reduction of the micro-hardness for both cements. The U100 cement showed less variation in the micro-hardness regardless of the curing protocol and storage time. CONCLUSIONS: The micro-hardness of the cements was affected by the curing and storage variables and were material-dependent.


Assuntos
Lâmpadas de Polimerização Dentária , Cimentos Dentários/química , Técnica para Retentor Intrarradicular , Cimentos de Resina/química , Água/química , Animais , Bovinos , Cimentos Dentários/efeitos da radiação , Testes de Dureza , Teste de Materiais , Polimerização , Cimentos de Resina/efeitos da radiação , Propriedades de Superfície , Fatores de Tempo
16.
J. appl. oral sci ; 25(6): 700-707, Nov.-Dec. 2017. tab, graf
Artigo em Inglês | LILACS, BBO | ID: biblio-893664

RESUMO

Abstract Due to increasing of aesthetic demand, ceramic crowns are widely used in different situations. However, to obtain long-term prognosis of restorations, a good conversion of resin cement is necessary. Objective: To evaluate the degree of conversion (DC) of one light-cure and two dual-cure resin cements under a simulated clinical cementation of ceramic crowns. Material and Methods: Prepared teeth were randomly split according to the ceramic's material, resin cement and curing protocol. The crowns were cemented as per manufacturer's directions and photoactivated either from occlusal suface only for 60 s; or from the buccal, occlusal and lingual surfaces, with an exposure time of 20 s on each aspect. After cementation, the specimens were stored in deionized water at 37°C for 7 days. Specimens were transversally sectioned from occlusal to cervical surfaces and the DC was determined along the cement line with three measurements taken and averaged from the buccal, lingual and approximal aspects using micro-Raman spectroscopy (Alpha 300R/WITec®). Data were analyzed by 3-way ANOVA and Tukey test at =5%. Results: Statistical analysis showed significant differences among cements, curing protocols and ceramic type (p<0.001). The curing protocol 3x20 resulted in higher DC for all tested conditions; lower DC was observed for Zr ceramic crowns; Duolink resin cement culminated in higher DC regardless ceramic composition and curing protocol. Conclusion: The DC of resin cement layers was dependent on the curing protocol and type of ceramic.


Assuntos
Humanos , Cimentos de Resina/química , Cimentos Dentários/química , Porcelana Dentária/química , Estética Dentária , Lâmpadas de Polimerização Dentária , Propriedades de Superfície , Teste de Materiais
17.
Artigo em Inglês | MEDLINE | ID: mdl-22140673

RESUMO

Surgical and nonsurgical techniques have been proposed to regenerate interdental papillae. The results are influenced by the morphology of the interdental space, which is the housing for the papilla. The concept of the interdental papillary "house" has been established not only to allow diagnosis of the causes of papillary loss, but also to manage and predict reconstruction of the interdental gingival tissue. The adjacent teeth in contact, involving the proximal contact, contour and shape of the teeth, course of the cementoenamel junction, interdental distance, and underlying bone crest, determine the outline of the house. Since the components are combined, an understanding of each allows adequate treatment planning involving interdisciplinary procedures. This new concept serves as a guide and teaching aid for the practitioner.


Assuntos
Gengiva/anatomia & histologia , Dente/anatomia & histologia , Processo Alveolar/anatomia & histologia , Doenças da Gengiva/diagnóstico , Doenças da Gengiva/cirurgia , Humanos , Planejamento de Assistência ao Paciente , Procedimentos de Cirurgia Plástica , Regeneração/fisiologia , Colo do Dente/anatomia & histologia
18.
J Appl Oral Sci ; 19(5): 544-8, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21986661

RESUMO

Hypodontia is the congenital absence of one or more teeth and may affect permanent teeth. Several options are indicated to treat hypodontia, including the maintenance of primary teeth or space redistribution for restorative treatment with partial adhesive bridges, tooth transplantation, and implants. However, a multidisciplinary approach is the most important requirement for the ideal treatment of hypodontia. This paper describes a multidisciplinary treatment plan for congenitally missing permanent mandibular second premolars involving orthodontics, implantology and prosthodontic specialties.


Assuntos
Anodontia/reabilitação , Adolescente , Implantes Dentários , Prótese Dentária , Seguimentos , Humanos , Masculino , Ortodontia , Equipe de Assistência ao Paciente , Radiografia Panorâmica , Resultado do Tratamento
19.
J Appl Oral Sci ; 19(1): 34-40, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21437467

RESUMO

OBJECTIVES: To evaluate the effect of a chewing exercise on pain intensity and pressure-pain threshold in patients with myofascial pain. METHODS: Twenty-nine consecutive women diagnosed with myofascial pain (MFP) according to the Research Diagnostic Criteria comprised the experimental group and 15 healthy age-matched female were used as controls. Subjects were asked to chew a gum stick for 9 min and to stay at rest for another 9 min afterwards. Pain intensity was rated on a visual analog scale (VAS) every 3 min. At 0, 9 and 18 min, the pressure-pain threshold (PPT) was measured bilaterally on the masseter and the anterior, medium, and posterior temporalis muscles. RESULTS: Patients with myofascial pain reported increase (76%) and no change (24%) on the pain intensity measured with the VAS. A reduction of the PPT at all muscular sites after the exercise and a non-significant recovery after rest were also observed. CONCLUSION: The following conclusions can be drawn: 1. there are at least two subtypes of patients with myofascial pain that respond differently to experimental chewing; 2. the chewing protocol had an adequate discriminative ability in distinguishing patients with myofascial pain from healthy controls.


Assuntos
Dor Facial/fisiopatologia , Mastigação/fisiologia , Músculos da Mastigação/fisiopatologia , Adolescente , Adulto , Análise de Variância , Estudos de Casos e Controles , Feminino , Humanos , Pessoa de Meia-Idade , Medição da Dor , Limiar da Dor/fisiologia , Palpação , Inquéritos e Questionários , Fatores de Tempo , Adulto Jovem
20.
Pro Fono ; 22(2): 151-7, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20640380

RESUMO

BACKGROUND: speech production in different modalities of oral prosthetic rehabilitation. AIM: to study the speech production of subjects submitted to different oral rehabilitation modalities. METHOD: 36 elderly individuals (average = 68 years) of both gender were evaluated. Participants were divided in three groups: 13 subjects with natural teeth (A); 13 edentate using maxillary and mandibular conventional dentures (B); and 10 edentate using maxillary conventional dentures and mandibular implant-supported prosthesis (C). Prosthesis stability was evaluated by a dentist and speech samples were analyzed by five speech-language pathologists. In order to determine the frequency of speech sound alterations, the Percentage of Correct Consonants (PCC) was used. RESULTS: few individuals presented speech alterations. Group C presented a higher occurrence of speech alterations (23.08%). Locked articulation was present in all groups; the reduction in lip movement was observed for groups A and B; exaggerated articulation and absence of saliva control was observed for group C. A smaller Percentage of Correct Consonants value was observed for the linguodental phonemes, in groups B and C, followed by the alveolar phonemes. Group A presented the majority of individuals with no speech alterations. On the other hand, for groups B and C, lips and tongue projection was frequently observed. No statistical difference was found between the groups. Most of the individuals in group B presented unsatisfactory prosthesis stability, but no association was identified between speech alterations and prosthesis stability. CONCLUSION: despite the small sample, the results of the study suggest that individuals using dentures present alterations in linguodental and alveolar phonemes. The type of prosthesis and its stability do not seem to interfere in speech production.


Assuntos
Prótese Dentária , Fala/fisiologia , Idoso , Idoso de 80 Anos ou mais , Prótese Dentária Fixada por Implante , Dentaduras , Feminino , Humanos , Masculino , Medida da Produção da Fala
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA