Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Opt Express ; 31(9): 14997-14999, 2023 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-37157351

RESUMO

This feature issue of Optics Express highlights contributions from authors who presented their latest research at the OPTICA Optical Sensors and Sensing Congress, held in Vancouver, British Columbia, Canada from 11-15 July 2022. The feature issue comprises 9 contributed papers, which expand upon their respective conference proceedings. The published papers introduced here cover a range of timely research topics in optics and photonics for chip-based sensing, open-path and remote sensing and fiber devices.

2.
Anal Chem ; 91(21): 14058-14065, 2019 11 05.
Artigo em Inglês | MEDLINE | ID: mdl-31552733

RESUMO

Color vision results from the interaction of retinal photopigments with reflected or transmitted visible light. The International Commission on Illumination (CIE) developed the CIE color-matching chart, which separates colors on the basis of the interaction of their spectral profiles with three retinal photopigments in the human eye. We report the development of an infrared chromaticity (CIE-IR) chart, which mimics the CIE chart, in order to discriminate between different chemicals on the basis of the interactions of their IR signatures with three different IR optical filters, instead of the retinal photopigments in the human eye. Our results demonstrate that the CIE-IR chart enables separation of different classes of chemicals, as the visible CIE chart does with color, except for those in the IR spectral region. Such results clearly show that the biomimetic sensing method based on human color vision is in fact a true analogue to color vision and that the proposed CIE-IR chart can be used as a classification method unique to this biomimetic sensing modality.


Assuntos
Visão de Cores , Cor , Humanos , Raios Infravermelhos
3.
Opt Express ; 25(19): 22738-22749, 2017 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-29041580

RESUMO

Control and manipulation of sound is of critical importance to many different scientific and engineering fields, requiring the design of rigid physical structures with precise geometries and material properties for the desired acoustics. In this work, we demonstrate the ability to manipulate the direction and magnitude of sound waves traveling in air using laser light, without the need for physical interfaces associated with different materials. Efficient reflection of sound waves off of transient, optically generated, abrupt air density barriers is demonstrated, with acoustic reflections greater than 25% of the incident acoustic wave amplitude. Implementation of multiple barriers, can result in complete suppress the transmission of incident acoustic signals as great as 70 dB. Additionally, shaping the laser beam acoustic waveguides can be generated with dramatically reduced transmission losses.

4.
Appl Opt ; 56(3): B74-B84, 2017 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-28157868

RESUMO

Traditionally, chemical sensing platforms have been hampered by the opposing concerns of increasing sensor capability while maintaining a minimal package size. Current sensors, although reasonably sized, are geared to more classical chemical threats, and the ability to expand their capabilities to a broader range of emerging threats is uncertain. Recently, photoacoustic spectroscopy, employed in a sensor format, has shown enormous potential to address these ever-changing threats. Photoacoustic spectroscopy is one of the more flexible infrared spectroscopy variants, and that flexibility allows for the construction of sensors that are designed for specific tasks. The Army Research Laboratory has, for the past 14 years, engaged in research into the development of photoacoustic sensing platforms with the goal of sensor miniaturization and the detection of a variety of chemical targets both proximally and at range. This paper reviews this work.

5.
Appl Opt ; 56(3): B159-B168, 2017 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-28157878

RESUMO

Trace chemical detection is a particularly challenging problem of significant Army interest. Optical diagnostic techniques offer rapid, accurate, sensitive, and highly selective detection of hazardous materials in a variety of systems. Multiplex coherent anti-stokes Raman scattering (MCARS) spectroscopy generates a complete Raman spectrum from the material of interest using a combination of a supercontinuum pulse, which drives multiple molecular vibrations simultaneously, and a narrowband probe pulse. In this study, we demonstrated the ability of MCARS to detect trace amounts of both explosive materials and chemical warfare agent simulants with limits of detection below 0.2 ng and 0.1 nl, respectively. Integration times were on the order of 10 ms, using a compact USB spectrometer. Characteristics of supercontinuum generation were studied and compared to results in the literature. Finally, an algorithm that utilizes a combination of the maximum entropy method and advanced Fourier filtering to analytically remove the non-resonant background from the MCARS spectra without any a priori knowledge of the vibrational spectrum of the material of interest.

6.
Appl Opt ; 56(3): B198-B213, 2017 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-28157898

RESUMO

Regenerated surface-enhanced Raman scattering (SERS) substrates allow users the ability to not only reuse sensing surfaces, but also tailor them to the sensing application needs (wavelength of the available laser, plasmon band matching). In this review, we discuss the development of SERS substrates for response to emerging threats and some of our collaborative efforts to improve on the use of commercially available substrate surfaces. Thus, we are able to extend the use of these substrates to broader Army needs (like emerging threat response).

7.
Small ; 10(21): 4287-92, 2014 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-25045064

RESUMO

The synthesis of plasmonic nanorattles with accessible electromagnetic hotspots that facilitate highly sensitive detection of chemical analytes using surface enhanced Raman scattering (SERS) is demonstrated. Raman spectra obtained from individual nanorattles demonstrate the significantly higher SERS activity compared to solid plasmonic nanostructures.

8.
J Mol Recognit ; 27(12): 739-45, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25319622

RESUMO

Bacterial peptide display libraries enable the rapid and efficient selection of peptides that have high affinity and selectivity toward their targets. Using a 15-mer random library on the outer surface of Escherichia coli (E.coli), high-affinity peptides were selected against a staphylococcal enterotoxin B (SEB) protein after four rounds of biopanning. On-cell screening analysis of affinity and specificity were measured by flow cytometry and directly compared to the synthetic peptide, off-cell, using peptide-ELISA. DNA sequencing of the positive clones after four rounds of microfluidic magnetic sorting (MMS) revealed a common consensus sequence of (S/T)CH(Y/F)W for the SEB-binding peptides R338, R418, and R445. The consensus sequence in these bacterial display peptides has similar amino acid characteristics with SEB peptide sequences isolated from phage display. The Kd measured by peptide-ELISA off-cell was 2.4 nM for R418 and 3.0 nM for R445. The bacterial peptide display methodology using the semiautomated MMS resulted in the discovery of selective peptides with affinity for a food safety and defense threat. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.


Assuntos
Enterotoxinas/metabolismo , Fenômenos Magnéticos , Microfluídica/métodos , Biblioteca de Peptídeos , Peptídeos/análise , Sequência de Aminoácidos , Ensaio de Imunoadsorção Enzimática , Fluorescência , Dados de Sequência Molecular , Peptídeos/química , Ligação Proteica
9.
J Phys Chem A ; 118(45): 10456-63, 2014 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-24991979

RESUMO

Laser-induced filamentation was used to study the dynamics of excited molecular nitrogen decay processes. It is well-known that upper excited nitrogen triplet states can be repopulated at time delays far longer than their fluorescence lifetimes. Examination of the time-resolved emission from several different species indicates that there are two major mechanisms acting to repopulate the N2(C(3)Πu) excited state. The results implicate dissociative electron recombination with the nitrogen cation dimer, N4(+), and energy pooling between two N2(A(3)Σu(+)) triplet states as the main pathways to repopulate the emissive upper triplet state. The densities of N2(A(3)Σu(+)) and free electrons produced during filamentation were measured under atmospheric pressures in nitrogen and estimated to be [N2(A(3)Σu(+))]0 = 3 × 10(15) cm(­3) and [e(­)]0 = 3 × 10(13) cm(­3). The methods outlined in this report could find significant utility in measuring the concentration profiles of these important reactive intermediates within laser-induced filaments produced under different conditions.

10.
Sensors (Basel) ; 13(5): 5814-25, 2013 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-23653050

RESUMO

Hazard detection systems must be evaluated with appropriate test material concentrations under controlled conditions in order to accurately identify and quantify unknown residues commonly utilized in theater. The existing assortment of hazard reference sample preparation methods/techniques presents a range of variability and reproducibility concerns, making it increasingly difficult to accurately assess optically- based detection technologies. To overcome these challenges, we examined the optimization, characterization, and calibration of microdroplets from a drop-on-demand microdispenser that has a proven capability for the preparation of energetic reference materials. Research presented herein focuses on the development of a simplistic instrument calibration technique and sample preparation protocol for explosive materials testing based on drop-on-demand technology. Droplet mass and reproducibility were measured using ultraviolet-visible (UV-Vis) absorption spectroscopy. The results presented here demonstrate the operational factors that influence droplet dispensing for specific materials (e.g., energetic and interferents). Understanding these parameters permits the determination of droplet and sample uniformity and reproducibility (typical R2 values of 0.991, relative standard deviation or RSD ≤ 5%), and thus the demonstrated maturation of a successful and robust methodology for energetic sample preparation.

11.
Appl Spectrosc ; 76(2): 163-172, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34643139

RESUMO

This paper examines infrared spectroscopic effects for the standoff detection of an explosive material, hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), inkjet printed on an aluminum surface. Results of a spectroscopic study are described, using multiple optical setups. These setups were selected to explore how variations in the angles of incidence and collection from the surface of the material result in corresponding variations in the spectral signatures. The goal of these studies is to provide an understanding of these spectral changes since it affects standoff detection of hazardous materials on a reflective substrate. We demonstrate that variations in spectral effects are dependent on the relative surface concentration of the deposited RDX. We also show that it is reasonable to use spectroscopic data collected in a standard laboratory infrared spectrometer outfitted with a variable angle reflectometer set at 0° as reference spectra for data collected in a standoff configuration. These results are important to provide a systematic approach to understanding infrared (IR) spectra collection using standoff systems in the field, and to allow for comparison between such data, and data collected in the laboratory. Although the precise results are constrained to a specific material system (thin layers on a reflective substrate), the approach and general discussion provided are applicable to a broad range of IR standoff sensing techniques and applications.

12.
Anal Chem ; 83(23): 8953-8, 2011 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-22017379

RESUMO

We report a novel surface enhanced Raman scattering (SERS) substrate platform based on a common filter paper adsorbed with plasmonic nanostructures that overcomes many of the challenges associated with existing SERS substrates. The paper-based design results in a substrate that combines all of the advantages of conventional rigid and planar SERS substrates in a dynamic flexible scaffolding format. In this paper, we discuss the fabrication, physical characterization, and SERS activity of our novel substrates using nonresonant analytes. The SERS substrate was found to be highly sensitive, robust, and amiable to several different environments and target analytes. It is also cost-efficient and demonstrates high sample collection efficiency and does not require complex fabrication methodologies. The paper substrate has high sensitivity (0.5 nM trans-1,2-bis(4-pyridyl)ethene (BPE)) and excellent reproducibility (~15% relative standard deviation (RSD)). The paper substrates demonstrated here establish a novel platform for integrating SERS with already existing analytical techniques such as chromatography and microfluidics, imparting chemical specificity to these techniques.


Assuntos
Nanoestruturas/química , Análise Espectral Raman , Alcenos/análise , Ouro/química , Nanotubos/química , Papel
13.
Appl Spectrosc ; 73(2): 214-220, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30347995

RESUMO

The Department of Defense (DOD) and first responder communities are evaluating and developing optical systems for the detection and identification of explosives and components used for assembling homemade explosives (HMEs). Emerging detection technologies must be evaluated with authentic hazard material concentrations to ensure their accurate and reliable use in the field. In this work, infrared (IR) reflectance spectra over the spectral rage of 1000-1700 cm-1 were collected for different concentrations of inkjet-printed RDX (cyclotrimethylenetrinitramine) samples deposited onto aluminum substrates. A plot of the integrated area of both the symmetric and asymmetric NO2 vibrational bands for RDX on aluminum exhibited good linearity over the concentration range 20-500 µg/cm2. Detection limits for RDX on an aluminum surface were calculated to be 10.7 µg/cm2 for the symmetric NO2 vibrational band and 1.4 µg/cm2 for the asymmetric NO2 vibrational band. Evaluation of the NO2 vibrational band areas at different locations of the RDX array demonstrated that the samples exhibited good homogeneity across the surface. The concentration of an unknown sample of RDX on aluminum was determined using the fitted equations; results showed good agreement between the calculated and actual RDX surface concentration. The lot-to-lot variation of RDX on the aluminum surface was compared using the long wavelength infrared (LWIR) spectral band areas for two different lots of standards printed at the same RDX surface concentration. Results showed excellent lot-to-lot agreement indicating good reproducibility of the standards for RDX.

14.
Opt Express ; 15(21): 14044-56, 2007 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-19550677

RESUMO

We report on the delivery of low energy ultra-short (<1 ps) laser pulses for laser induced breakdown spectroscopy (LIBS). Ultra-short pulses have the advantage of high peak irradiance even at very low pulse energies. This opens the possibility to use compact, rare-earth doped fiber lasers in a portable platform for point detection applications using LIBS for elemental analysis. The use of low energy ultra-short pulses minimizes the generation of a broad continuum background in the emission spectrum, which permits the use of non-gated detection schemes using very simple and compact spectrometers. The pulse energies used to produce high-quality LIBS spectra in this investigation are some of the lowest reported and we investigate the threshold pulse requirements for a number of near IR pulse wavelengths (785-1500 nm) and observe that the pulse wavelength has no effects on the threshold for observation of plasma emission or the quality of the emission spectra obtained.

15.
Appl Spectrosc ; 71(5): 833-838, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27340220

RESUMO

Detection and identification of unknown and possibly hazardous materials is a vital area of research to which infrared (IR) spectroscopy is ideally suited. Infrared absorption spectra can be measured with many sensing paradigms of which photoacoustic spectroscopy (PAS) is a sensitive and flexible variant. The flexibility of PAS allows for the construction of narrowly tailored spectroscopic sensors that are designed for specific tasks. We discuss the evaluation of an interferometric PAS sensor by the measurement of common explosive hazards from a standoff distance of 1 m. Reproduction of IR absorption spectra for 1,3,5-trinitroperhydro-1,3,5-triazine (RDX), pentaerythritol tetranitrate (PETN), and 2,4,6-trinitrotoluene (TNT) demonstrate the capabilities of the interferometric sensor for standoff explosives detection.

16.
J Opt ; 19(8)2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29375751

RESUMO

Sensors are devices or systems able to detect, measure and convert magnitudes from any domain to an electrical one. Using light as a probe for optical sensing is one of the most efficient approaches for this purpose. The history of optical sensing using some methods based on absorbance, emissive and florescence properties date back to the 16th century. The field of optical sensors evolved during the following centuries, but it did not achieve maturity until the demonstration of the first laser in 1960. The unique properties of laser light become particularly important in the case of laser-based sensors, whose operation is entirely based upon the direct detection of laser light itself, without relying on any additional mediating device. However, compared with freely propagating light beams, artificially engineered optical fields are in increasing demand for probing samples with very small sizes and/or weak light-matter interaction. Optical fiber sensors constitute a subarea of optical sensors in which fiber technologies are employed. Different types of specialty and photonic crystal fibers provide improved performance and novel sensing concepts. Actually, structurization with wavelength or subwavelength feature size appears as the most efficient way to enhance sensor sensitivity and its detection limit. This leads to the area of micro- and nano-engineered optical sensors. It is expected that the combination of better fabrication techniques and new physical effects may open new and fascinating opportunities in this area. This roadmap on optical sensors addresses different technologies and application areas of the field. Fourteen contributions authored by experts from both industry and academia provide insights into the current state-of-the-art and the challenges faced by researchers currently. Two sections of this paper provide an overview of laser-based and frequency comb-based sensors. Three sections address the area of optical fiber sensors, encompassing both conventional, specialty and photonic crystal fibers. Several other sections are dedicated to micro- and nano-engineered sensors, including whispering-gallery mode and plasmonic sensors. The uses of optical sensors in chemical, biological and biomedical areas are described in other sections. Different approaches required to satisfy applications at visible, infrared and THz spectral regions are also discussed. Advances in science and technology required to meet challenges faced in each of these areas are addressed, together with suggestions on how the field could evolve in the near future.

17.
Appl Spectrosc ; 57(11): 1340-5, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14658146

RESUMO

A novel methodology has been developed for the investigation of bacterial spores. Specifically, this method has been used to probe the spore coat composition of two different Bacillus stearothermophilus variants. This technique may be useful in many applications; most notably, development of novel detection schemes toward potentially harmful bacteria. This method would also be useful as an ancillary environmental monitoring system where sterility is of importance (i.e., food preparation areas as well as invasive and minimally invasive medical applications). This unique detection scheme is based on the near-infrared (NIR) surface-enhanced Raman scattering (SERS) from single, optically trapped, bacterial spores. The SERS spectra of bacterial spores in aqueous media have been measured using SERS substrates based on approximately 60-nm-diameter gold colloids bound to 3-aminopropyltriethoxysilane derivatized glass. The light from a 787-nm laser diode was used to trap and manipulate as well as simultaneously excite the SERS of an individual bacterial spore. The collected SERS spectra were examined for uniqueness and the applicability of this technique for the strain discrimination of Bacillus stearothermophilus spores. Comparison of normal Raman and SERS spectra reveals not only an enhancement of the normal Raman spectral features but also the appearance of spectral features absent in the normal Raman spectrum.


Assuntos
Geobacillus stearothermophilus/classificação , Geobacillus stearothermophilus/isolamento & purificação , Micromanipulação/instrumentação , Nanotecnologia/instrumentação , Estimulação Física/instrumentação , Espectrofotometria Infravermelho/instrumentação , Análise Espectral Raman/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Células Imobilizadas/química , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Geobacillus stearothermophilus/química , Micromanipulação/métodos , Nanotecnologia/métodos , Estimulação Física/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Especificidade da Espécie , Espectrofotometria Infravermelho/métodos , Análise Espectral Raman/métodos , Ressonância de Plasmônio de Superfície/métodos
18.
Appl Spectrosc ; 68(3): 287-96, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24666945

RESUMO

The United States Army and the first responder community are increasingly focusing efforts on energetic materials detection and identification. Main hazards encountered in theater include homemade explosives and improvised explosive devices, in part fabricated from simple components like ammonium nitrate (AN). In order to accurately detect and identify these unknowns (energetic or benign), fielded detection systems must be accurately trained using well-understood universal testing substrates. These training substrates must contain target species at known concentrations and recognized polymorphic phases. Ammonium nitrate is an explosive precursor material that demonstrates several different polymorphic phases dependent upon how the material is deposited onto testing substrates. In this paper, known concentrations of AN were uniformly deposited onto commercially available surface-enhanced Raman scattering (SERS) substrates using a drop-on-demand inkjet printing system. The phase changes observed after the deposition of AN under several solvent conditions are investigated. Characteristics of the collected SERS spectra of AN are discussed, and it is demonstrated that an understanding of the exact nature of the AN samples deposited will result in an increased ability to accurately and reliably "train" hazard detection systems.

19.
Appl Spectrosc ; 67(4): 396-403, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23601539

RESUMO

We present the results of a three-year collaboration between the U.S. Army Edgewood Chemical Biological Center and the U.S. Army Research Laboratory-Aldelphi Laboratory Center on the evaluation of selected nanometallic surfaces developed for the Defense Advanced Research Projects Agency Surface-Enhanced Raman Scattering (SERS) Science and Technology Fundamentals program. The primary role of the two Army labs was to develop the analytical and spectroscopic figures of merit to unambiguously compare the sensitivity and reproducibility of various SERS substrates submitted by the program participants. We present the design and implementation of an evaluation protocol for SERS active surfaces enabling an enhancement value calculation from which different substrates can be directly compared. This method was established to: (1) collect physical and spectral characterization data from the small number of substrates (performer supplied) typically encountered, and (2) account for the complex fabrication technique and varying nature of the substrate platforms encountered within this program.


Assuntos
Nanoestruturas/química , Prata/química , Análise Espectral Raman/métodos , Curva ROC , Reprodutibilidade dos Testes
20.
Biotechniques ; 52(2): 95-102, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22313407

RESUMO

Peptide reagents can serve as alternatives or replacements to antibodies in sensing or diagnostic applications. The passive adsorption of peptides onto polystyrene surfaces can limit the target binding capability, especially for short, positively charged, or hydrophobic sequences. In this report, we show that fusing a peptide with a previously characterized 12-amino acid polystyrene binding sequence (PS-tag) improves overall peptide solubility and enzyme-linked immunosorbent assay (ELISA) results using the peptide as a capture agent. Specific improvements for protective antigen (PA; Bacillus anthracis) protein binding peptides selected from bacterial surface display were compared with native or biotinylated peptides. The PS-tag was added to either peptide terminus, using a (Gly)(4) spacer, and comparable binding affinities were obtained. Fusion with the PS-tag did not have any negative impact on peptide secondary structure as measured by circular dichroism. The addition of the PS-tag provides a convenient method to utilize peptide reagents from peptide display libraries as capture agents in an ELISA format without the need for a biotin tag or concerns about passive adsorption of critical residues for target capture.


Assuntos
Fragmentos de Peptídeos/genética , Fragmentos de Peptídeos/metabolismo , Poliestirenos/metabolismo , Proteínas Recombinantes de Fusão/genética , Proteínas Recombinantes de Fusão/metabolismo , Sequência de Aminoácidos , Ensaio de Imunoadsorção Enzimática/métodos , Dados de Sequência Molecular , Ligação Proteica/genética , Análise de Sequência de Proteína/métodos , Solubilidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA