Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Orthop Trauma ; 31(12): 611-616, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28742789

RESUMO

OBJECTIVE: To evaluate venous thromboembolism (VTE) prophylaxis adherence and effectiveness in orthopaedic trauma patients who had vascular or radiographic studies showing deep vein thromboses or pulmonary emboli. DESIGN: Retrospective review. SETTING: A level I trauma center that independently services a 5-state region. PATIENTS: Four hundred seventy-six patients with orthopaedic trauma who underwent operative treatments for orthopaedic injuries and had symptom-driven diagnostic VTE studies. INTERVENTION: The medical records of patients treated surgically between July 2010 and March 2013 were interrogated using a technical tool that electronically captures thrombotic event data from vascular and radiologic imaging studies by natural language processing. MAIN OUTCOME MEASUREMENTS: Patients were evaluated for hospital guideline-directed VTE prophylaxis adherence with mechanical or chemical prophylaxis. Patient demographics, associated injuries, mechanism of injury, and symptoms that led to imaging for a VTE were also assessed. RESULTS: Of the 476 orthopaedic patients who met inclusion criteria, 100 (mean age 52.3 median 52, SD 18.3, 70% men) had positive VTE studies. Three hundred seventy-six (age 47.3, SD 17.3, 69% men) had negative VTE studies. Of the 100 patients with VTE, 63 deep vein thromboses, and 49 pulmonary emboli were found. Eight-five percent of all patients met hospital guideline-VTE prophylaxis standards. CONCLUSION: The study population had better than previously reported VTE prophylaxis adherence, however, patients still developed VTEs. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Vasos Sanguíneos/diagnóstico por imagem , Procedimentos Ortopédicos/efeitos adversos , Complicações Pós-Operatórias , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia Doppler/métodos , Tromboembolia Venosa/prevenção & controle , Ferimentos e Lesões/complicações , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fidelidade a Diretrizes , Humanos , Escala de Gravidade do Ferimento , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Centros de Traumatologia , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/etiologia , Ferimentos e Lesões/cirurgia , Adulto Jovem
2.
Infect Control Hosp Epidemiol ; 32(8): 757-62, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21768758

RESUMO

OBJECTIVE: To develop and validate an electronic surveillance tool for catheter-associated urinary tract infections (CAUTIs). DESIGN: Retrospective cohort study. SETTING: 413-bed university-affiliated urban teaching hospital. METHODS: An electronic surveillance tool was developed for CAUTI and urinary catheter utilization based on the objective components of the National Healthcare Safety Network (NHSN) definitions including fever, urinalysis, and urine culture. Results were compared to manual chart review by an infection preventionist (IP). RESULTS: During January and February 2010, 204 positive urine cultures (≥10(3) colony-forming units/mL) were identified in 136 patients with indwelling urinary catheters during their hospitalization. The electronic surveillance tool detected 60 CAUTI cases and 7,098 catheter-days, yielding a CAUTI incidence rate of 8.5 per 1,000 catheter-days. Urinary catheter utilization ratios (Foley-days/patient-days) were: acute care units, 0.27 (3,637 of 13,229); intensive care units, 0.77 (3,461 of 4,469); and overall, 0.40 (7,098 of 17,698). In comparison, the IP identified 59 cases by manual review with a sensitivity of 51 of 59 (86.4%), specificity 136 of 145 (93.8%), and negative predictive value of 136 of 144 (94.4%). Fever was present in 54 of 59 (91.5%) of CAUTI cases identified manually, while subjective criteria were documented in only 6 of 59 (10.2%) infections. Agreement between the electronic surveillance and manual IP review was assessed as very good (κ, 0.80; 95% confidence interval, 0.71-0.89). CONCLUSIONS: We report an attempt at automating surveillance for CAUTI. With a high negative predictive value, the electronic tool allows for more efficient CAUTI surveillance and facilitates housewide trending of rates and catheter utilization. This approach should be validated in different patient populations.


Assuntos
Infecções Relacionadas a Cateter/epidemiologia , Infecção Hospitalar/epidemiologia , Vigilância da População/métodos , Infecções Urinárias/epidemiologia , Infecções Urinárias/etiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Infecções Relacionadas a Cateter/diagnóstico , Estudos de Coortes , Infecção Hospitalar/diagnóstico , Registros Eletrônicos de Saúde , Feminino , Hospitais Universitários , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Infecções Urinárias/diagnóstico , Washington , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA