Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Perit Dial Int ; : 8968608241270294, 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39105257

RESUMO

Automation has allowed clinicians to program PD treatment parameters, all while obtaining extensive individual treatment data. This data populates in a centralized online platform shortly after PD treatment completion. Individual treatment data available to providers includes patients' vital signs, alarms, bypasses, prescribed PD treatment, actual treatment length, individual cycle fill volumes, ultrafiltration volumes, as well as fill, dwell, and drain times. However, there is no guidance about how often or if this data should be assessed by the clinical team members. We set out to determine current practice patterns by surveying members of the home dialysis team managing PD patients across the United States and Canada. A total of 127 providers completed the survey. While 91% of respondents reported having access to a remote monitoring platform, only 31% reported having a standardized protocol for data monitoring. Rating their perceived importance of having a standard protocol for remote data monitoring, on a scale of 0 (not important at all) to 10 (extremely important), the average response was 8 (physicians 7; nurses 9). Most nurses reported reviewing the data multiple times per week, whereas most physicians reported viewing the data only during regular/monthly visits. Although most of the providers who responded have access to remote monitoring data and feel that regular review is important, the degree of its utilization is variable, and the way in which the information is used is not commonly protocolized. Working to standardize data interpretation, testing algorithms, and educating providers to help process and present the data are important next steps.

2.
Med Phys ; 39(11): 6818-37, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23127075

RESUMO

PURPOSE: While Monte Carlo particle transport has proven useful in many areas (treatment head design, dose calculation, shielding design, and imaging studies) and has been particularly important for proton therapy (due to the conformal dose distributions and a finite beam range in the patient), the available general purpose Monte Carlo codes in proton therapy have been overly complex for most clinical medical physicists. The learning process has large costs not only in time but also in reliability. To address this issue, we developed an innovative proton Monte Carlo platform and tested the tool in a variety of proton therapy applications. METHODS: Our approach was to take one of the already-established general purpose Monte Carlo codes and wrap and extend it to create a specialized user-friendly tool for proton therapy. The resulting tool, TOol for PArticle Simulation (TOPAS), should make Monte Carlo simulation more readily available for research and clinical physicists. TOPAS can model a passive scattering or scanning beam treatment head, model a patient geometry based on computed tomography (CT) images, score dose, fluence, etc., save and restart a phase space, provides advanced graphics, and is fully four-dimensional (4D) to handle variations in beam delivery and patient geometry during treatment. A custom-designed TOPAS parameter control system was placed at the heart of the code to meet requirements for ease of use, reliability, and repeatability without sacrificing flexibility. RESULTS: We built and tested the TOPAS code. We have shown that the TOPAS parameter system provides easy yet flexible control over all key simulation areas such as geometry setup, particle source setup, scoring setup, etc. Through design consistency, we have insured that user experience gained in configuring one component, scorer or filter applies equally well to configuring any other component, scorer or filter. We have incorporated key lessons from safety management, proactively removing possible sources of user error such as line-ordering mistakes. We have modeled proton therapy treatment examples including the UCSF eye treatment head, the MGH stereotactic alignment in radiosurgery treatment head and the MGH gantry treatment heads in passive scattering and scanning modes, and we have demonstrated dose calculation based on patient-specific CT data. Initial validation results show agreement with measured data and demonstrate the capabilities of TOPAS in simulating beam delivery in 3D and 4D. CONCLUSIONS: We have demonstrated TOPAS accuracy and usability in a variety of proton therapy setups. As we are preparing to make this tool freely available for researchers in medical physics, we anticipate widespread use of this tool in the growing proton therapy community.


Assuntos
Método de Monte Carlo , Terapia com Prótons/métodos , Neoplasias Oculares/diagnóstico por imagem , Neoplasias Oculares/radioterapia , Humanos , Melanoma/diagnóstico por imagem , Melanoma/radioterapia , Medicina de Precisão , Terapia com Prótons/instrumentação , Radiocirurgia , Dosagem Radioterapêutica , Espalhamento de Radiação , Software , Tomografia Computadorizada por Raios X
3.
Phys Med Biol ; 66(17)2021 09 03.
Artigo em Inglês | MEDLINE | ID: mdl-34412044

RESUMO

The chemical stage of the Monte Carlo track-structure simulation code Geant4-DNA has been revised and validated. The root-mean-square (RMS) empirical parameter that dictates the displacement of water molecules after an ionization and excitation event in Geant4-DNA has been shortened to better fit experimental data. The pre-defined dissociation channels and branching ratios were not modified, but the reaction rate coefficients for simulating the chemical stage of water radiolysis were updated. The evaluation of Geant4-DNA was accomplished with TOPAS-nBio. For that, we compared predicted time-dependentGvalues in pure liquid water for·OH, e-aq, and H2with published experimental data. For H2O2and H·, simulation of added scavengers at different concentrations resulted in better agreement with measurements. In addition, DNA geometry information was integrated with chemistry simulation in TOPAS-nBio to realize reactions between radiolytic chemical species and DNA. This was used in the estimation of the yield of single-strand breaks (SSB) induced by137Csγ-ray radiolysis of supercoiled pUC18 plasmids dissolved in aerated solutions containing DMSO. The efficiency of SSB induction by reaction between radiolytic species and DNA used in the simulation was chosen to provide the best agreement with published measurements. An RMS displacement of 1.24 nm provided agreement with measured data within experimental uncertainties for time-dependentGvalues and under the presence of scavengers. SSB efficiencies of 24% and 0.5% for·OH and H·, respectively, led to an overall agreement of TOPAS-nBio results within experimental uncertainties. The efficiencies obtained agreed with values obtained with published non-homogeneous kinetic model and step-by-step Monte Carlo simulations but disagreed by 12% with published direct measurements. Improvement of the spatial resolution of the DNA damage model might mitigate such disagreement. In conclusion, with these improvements, Geant4-DNA/TOPAS-nBio provides a fast, accurate, and user-friendly tool for simulating DNA damage under low linear energy transfer irradiation.


Assuntos
Dano ao DNA , Água , Simulação por Computador , Transferência Linear de Energia , Método de Monte Carlo
4.
Radiat Res ; 191(2): 125-138, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30609382

RESUMO

The TOPAS Monte Carlo (MC) system is used in radiation therapy and medical imaging research, having played a significant role in making Monte Carlo simulations widely available for proton therapy related research. While TOPAS provides detailed simulations of patient scale properties, the fundamental unit of the biological response to radiation is a cell. Thus, our goal was to develop TOPAS-nBio, an extension of TOPAS dedicated to advance understanding of radiobiological effects at the (sub-)cellular, (i.e., the cellular and sub-cellular) scale. TOPAS-nBio was designed as a set of open source classes that extends TOPAS to model radiobiological experiments. TOPAS-nBio is based on and extends Geant4-DNA, which extends the Geant4 toolkit, the basis of TOPAS, to include very low-energy interactions of particles down to vibrational energies, explicitly simulates every particle interaction (i.e., without using condensed histories) and propagates radiolysis products. To further facilitate the use of TOPAS-nBio, a graphical user interface was developed. TOPAS-nBio offers full track-structure Monte Carlo simulations, integration of chemical reactions within the first millisecond, an extensive catalogue of specialized cell geometries as well as sub-cellular structures such as DNA and mitochondria, and interfaces to mechanistic models of DNA repair kinetics. We compared TOPAS-nBio simulations to measured and published data of energy deposition patterns and chemical reaction rates (G values). Our simulations agreed well within the experimental uncertainties. Additionally, we expanded the chemical reactions and species provided in Geant4-DNA and developed a new method based on independent reaction times (IRT), including a total of 72 reactions classified into 6 types between neutral and charged species. Chemical stage simulations using IRT were a factor of 145 faster than with step-by-step tracking. Finally, we applied the geometric/chemical modeling to obtain initial yields of double-strand breaks (DSBs) in DNA fibers for proton irradiations of 3 and 50 MeV and compared the effect of including chemical reactions on the number and complexity of DSB induction. Over half of the DSBs were found to include chemical reactions with approximately 5% of DSBs caused only by chemical reactions. In conclusion, the TOPAS-nBio extension to the TOPAS MC application offers access to accurate and detailed multiscale simulations, from a macroscopic description of the radiation field to microscopic description of biological outcome for selected cells. TOPAS-nBio offers detailed physics and chemistry simulations of radiobiological experiments on cells simulating the initially induced damage and links to models of DNA repair kinetics.


Assuntos
Simulação por Computador , Radiobiologia/métodos , Gráficos por Computador , Diagnóstico por Imagem , Humanos , Transferência Linear de Energia , Método de Monte Carlo , Terapia com Prótons , Radioterapia , Interface Usuário-Computador
5.
Radiat Res ; 191(1): 76-92, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30407901

RESUMO

Our understanding of radiation-induced cellular damage has greatly improved over the past few decades. Despite this progress, there are still many obstacles to fully understand how radiation interacts with biologically relevant cellular components, such as DNA, to cause observable end points such as cell killing. Damage in DNA is identified as a major route of cell killing. One hurdle when modeling biological effects is the difficulty in directly comparing results generated by members of different research groups. Multiple Monte Carlo codes have been developed to simulate damage induction at the DNA scale, while at the same time various groups have developed models that describe DNA repair processes with varying levels of detail. These repair models are intrinsically linked to the damage model employed in their development, making it difficult to disentangle systematic effects in either part of the modeling chain. These modeling chains typically consist of track-structure Monte Carlo simulations of the physical interactions creating direct damages to DNA, followed by simulations of the production and initial reactions of chemical species causing so-called "indirect" damages. After the induction of DNA damage, DNA repair models combine the simulated damage patterns with biological models to determine the biological consequences of the damage. To date, the effect of the environment, such as molecular oxygen (normoxic vs. hypoxic), has been poorly considered. We propose a new standard DNA damage (SDD) data format to unify the interface between the simulation of damage induction in DNA and the biological modeling of DNA repair processes, and introduce the effect of the environment (molecular oxygen or other compounds) as a flexible parameter. Such a standard greatly facilitates inter-model comparisons, providing an ideal environment to tease out model assumptions and identify persistent, underlying mechanisms. Through inter-model comparisons, this unified standard has the potential to greatly advance our understanding of the underlying mechanisms of radiation-induced DNA damage and the resulting observable biological effects when radiation parameters and/or environmental conditions change.


Assuntos
Dano ao DNA , Simulação por Computador , Reparo do DNA , Transferência Linear de Energia , Modelos Teóricos , Método de Monte Carlo
6.
Phys Med Biol ; 63(10): 105014, 2018 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-29697057

RESUMO

Simulation of water radiolysis and the subsequent chemistry provides important information on the effect of ionizing radiation on biological material. The Geant4 Monte Carlo toolkit has added chemical processes via the Geant4-DNA project. The TOPAS tool simplifies the modeling of complex radiotherapy applications with Geant4 without requiring advanced computational skills, extending the pool of users. Thus, a new extension to TOPAS, TOPAS-nBio, is under development to facilitate the configuration of track-structure simulations as well as water radiolysis simulations with Geant4-DNA for radiobiological studies. In this work, radiolysis simulations were implemented in TOPAS-nBio. Users may now easily add chemical species and their reactions, and set parameters including branching ratios, dissociation schemes, diffusion coefficients, and reaction rates. In addition, parameters for the chemical stage were re-evaluated and updated from those used by default in Geant4-DNA to improve the accuracy of chemical yields. Simulation results of time-dependent and LET-dependent primary yields Gx (chemical species per 100 eV deposited) produced at neutral pH and 25 °C by short track-segments of charged particles were compared to published measurements. The LET range was 0.05-230 keV µm-1. The calculated Gx values for electrons satisfied the material balance equation within 0.3%, similar for protons albeit with long calculation time. A smaller geometry was used to speed up proton and alpha simulations, with an acceptable difference in the balance equation of 1.3%. Available experimental data of time-dependent G-values for [Formula: see text] agreed with simulated results within 7% ± 8% over the entire time range; for [Formula: see text] over the full time range within 3% ± 4%; for H2O2 from 49% ± 7% at earliest stages and 3% ± 12% at saturation. For the LET-dependent Gx, the mean ratios to the experimental data were 1.11 ± 0.98, 1.21 ± 1.11, 1.05 ± 0.52, 1.23 ± 0.59 and 1.49 ± 0.63 (1 standard deviation) for [Formula: see text], [Formula: see text], H2, H2O2 and [Formula: see text], respectively. In conclusion, radiolysis and subsequent chemistry with Geant4-DNA has been successfully incorporated in TOPAS-nBio. Results are in reasonable agreement with published measured and simulated data.


Assuntos
Simulação por Computador , DNA/química , Elétrons , Método de Monte Carlo , Imagens de Fantasmas , Radiólise de Impulso , Radiobiologia/métodos , Fenômenos Químicos , Humanos , Transferência Linear de Energia , Água
7.
Phys Med Biol ; 60(13): 5019-35, 2015 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-26061457

RESUMO

The aim of this work was to improve the computational efficiency of Monte Carlo simulations when tracking protons through a proton therapy treatment head. Two proton therapy facilities were considered, the Francis H Burr Proton Therapy Center (FHBPTC) at the Massachusetts General Hospital and the Crocker Lab eye treatment facility used by University of California at San Francisco (UCSFETF). The computational efficiency was evaluated for phase space files scored at the exit of the treatment head to determine optimal parameters to improve efficiency while maintaining accuracy in the dose calculation. For FHBPTC, particles were split by a factor of 8 upstream of the second scatterer and upstream of the aperture. The radius of the region for Russian roulette was set to 2.5 or 1.5 times the radius of the aperture and a secondary particle production cut (PC) of 50 mm was applied. For UCSFETF, particles were split a factor of 16 upstream of a water absorber column and upstream of the aperture. Here, the radius of the region for Russian roulette was set to 4 times the radius of the aperture and a PC of 0.05 mm was applied. In both setups, the cylindrical symmetry of the proton beam was exploited to position the split particles randomly spaced around the beam axis. When simulating a phase space for subsequent water phantom simulations, efficiency gains between a factor of 19.9 ± 0.1 and 52.21 ± 0.04 for the FHTPC setups and 57.3 ± 0.5 for the UCSFETF setups were obtained. For a phase space used as input for simulations in a patient geometry, the gain was a factor of 78.6 ± 7.5. Lateral-dose curves in water were within the accepted clinical tolerance of 2%, with statistical uncertainties of 0.5% for the two facilities. For the patient geometry and by considering the 2% and 2mm criteria, 98.4% of the voxels showed a gamma index lower than unity. An analysis of the dose distribution resulted in systematic deviations below of 0.88% for 20% of the voxels with dose of 20% of the maximum or more.


Assuntos
Algoritmos , Terapia com Prótons/métodos , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Método de Monte Carlo , Dosagem Radioterapêutica
8.
Phys Med Biol ; 60(13): 5037-52, 2015 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-26061583

RESUMO

The aim of this work was to develop a framework for modeling organ effects within TOPAS (TOol for PArticle Simulation), a wrapper of the Geant4 Monte Carlo toolkit that facilitates particle therapy simulation. The DICOM interface for TOPAS was extended to permit contour input, used to assign voxels to organs. The following dose response models were implemented: The Lyman-Kutcher-Burman model, the critical element model, the population based critical volume model, the parallel-serial model, a sigmoid-based model of Niemierko for normal tissue complication probability and tumor control probability (TCP), and a Poisson-based model for TCP. The framework allows easy manipulation of the parameters of these models and the implementation of other models. As part of the verification, results for the parallel-serial and Poisson model for x-ray irradiation of a water phantom were compared to data from the AAPM Task Group 166. When using the task group dose-volume histograms (DVHs), results were found to be sensitive to the number of points in the DVH, with differences up to 2.4%, some of which are attributable to differences between the implemented models. New results are given with the point spacing specified. When using Monte Carlo calculations with TOPAS, despite the relatively good match to the published DVH's, differences up to 9% were found for the parallel-serial model (for a maximum DVH difference of 2%) and up to 0.5% for the Poisson model (for a maximum DVH difference of 0.5%). However, differences of 74.5% (in Rectangle1), 34.8% (in PTV) and 52.1% (in Triangle) for the critical element, critical volume and the sigmoid-based models were found respectively. We propose a new benchmark for verification of organ effect models in proton therapy. The benchmark consists of customized structures in the spread out Bragg peak plateau, normal tissue, tumor, penumbra and in the distal region. The DVH's, DVH point spacing, and results of the organ effect models are provided. The models were used to calculate dose response for a Head and Neck patient to demonstrate functionality of the new framework and indicate the degree of variability between the models in proton therapy.


Assuntos
Terapia com Prótons/métodos , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Software , Benchmarking , Determinação de Ponto Final , Método de Monte Carlo , Dosagem Radioterapêutica
9.
Neurology ; 52(5): 1081-4, 1999 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-10102437

RESUMO

Recent major surgery is an exclusion criterion for thrombolysis. Six patients with acute ischemic stroke underwent intra-arterial thrombolysis after recent open heart surgery without clinically significant bleeding complications, although one patient developed a small, asymptomatic cerebellar hemorrhage. Intra-arterial thrombolysis may be an option for patients with cerebral embolism in the perioperative period.


Assuntos
Transtornos Cerebrovasculares/tratamento farmacológico , Terapia Trombolítica , Ativador de Plasminogênio Tipo Uroquinase/uso terapêutico , Idoso , Angiografia Cerebral , Feminino , Humanos , Injeções Intra-Arteriais , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Tomografia Computadorizada por Raios X
10.
J Neurotrauma ; 11(6): 711-20, 1994 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-7723070

RESUMO

A retrospective case-control study was undertaken to determine the best technique to measure neural canal encroachment at each lumbar level following burst fracture and its relationship to the presence of neurologic deficit. Only patients with postinjury CT scans demonstrating a disrupted posterior body with a retropulsed bone fragment were included. Patients were divided into groups based on the level of bony injury (T12-L5) and neurologic status. Neurologic injury was classified as follows: normal (N), root (R), or cauda equina/conus/paraplegic/paraparetic (C/P). The mean transverse spinal area (TSA, cm2), spinal canal percentage patency (PP), and midsagittal diameter (MSD) were determined for each neurologic group and lumbar level. A "calculated" TSA, based on midsagittal and anterior-posterior diameters, was also derived for each patient. The data were compared level by level and correlated with the patient's neurologic status. At L1, the critical TSA was 1.0 cm2. All patients with TSAs less than this were paraplegic. At both T12 and L1, TSAs in the range of 1.0-1.25 cm2 were observed in both normal and neurologically impaired patients. A critically significant TSA was not established for levels T12, L2, L3, L4, or L5; however, the data indicated that a smaller TSA can be tolerated at successively caudal levels without neurologic deficit. No meaningful correlation between root injury and TSA was observed. The data also indicated that measurement of TSA is a more accurate method for evaluating neural canal encroachment than PP or MSD. The "calculated" TSA is a simple, objective method for obtaining this information without the aid of a computer. This study suggests that absolute TSA should be utilized in future studies evaluating decompressive treatment of thoracolumbar pathology.


Assuntos
Vértebras Lombares/lesões , Traumatismos da Medula Espinal/diagnóstico por imagem , Fraturas da Coluna Vertebral/diagnóstico por imagem , Adolescente , Adulto , Idoso , Estudos de Casos e Controles , Criança , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/patologia , Masculino , Pessoa de Meia-Idade , Paraplegia/diagnóstico por imagem , Paraplegia/patologia , Estudos Retrospectivos , Canal Medular/diagnóstico por imagem , Canal Medular/patologia , Traumatismos da Medula Espinal/diagnóstico , Traumatismos da Medula Espinal/patologia , Fraturas da Coluna Vertebral/diagnóstico , Fraturas da Coluna Vertebral/patologia , Vértebras Torácicas/diagnóstico por imagem , Vértebras Torácicas/lesões , Vértebras Torácicas/patologia , Tomografia Computadorizada por Raios X , Índices de Gravidade do Trauma
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA