Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 329
Filtrar
1.
N Engl J Med ; 391(1): 56-59, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38959481

RESUMO

Hereditary angioedema is a potentially life-threatening autosomal dominant condition, causing attacks of angioedema due to failure to regulate bradykinin. Nearly all cases of hereditary angioedema are caused by mutations in the gene encoding C1 inhibitor, SERPING1. C1 inhibitor is a multifunctional protein produced in the liver that regulates the kallikrein-kinin system at multiple points. An infant with genetically confirmed hereditary angioedema and low C1 inhibitor levels (but without previous episodes of angioedema) underwent liver transplantation for biliary atresia, an unrelated condition. Liver transplantation led to normalization of the C1 inhibitor level and function. To our knowledge, this represents the first patient to be potentially cured of hereditary angioedema.


Assuntos
Angioedemas Hereditários , Proteína Inibidora do Complemento C1 , Transplante de Fígado , Humanos , Proteína Inibidora do Complemento C1/uso terapêutico , Angioedemas Hereditários/tratamento farmacológico , Angioedemas Hereditários/complicações , Angioedemas Hereditários/genética , Lactente , Masculino , Feminino
2.
Am J Respir Crit Care Med ; 209(8): 960-972, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38127850

RESUMO

Rationale: Cardiovascular events after chronic obstructive pulmonary disease (COPD) exacerbations are recognized. Studies to date have been post hoc analyses of trials, did not differentiate exacerbation severity, included death in the cardiovascular outcome, or had insufficient power to explore individual outcomes temporally.Objectives: We explore temporal relationships between moderate and severe exacerbations and incident, nonfatal hospitalized cardiovascular events in a primary care-derived COPD cohort.Methods: We included people with COPD in England from 2014 to 2020, from the Clinical Practice Research Datalink Aurum primary care database. The index date was the date of first COPD exacerbation or, for those without exacerbations, date upon eligibility. We determined composite and individual cardiovascular events (acute coronary syndrome, arrhythmia, heart failure, ischemic stroke, and pulmonary hypertension) from linked hospital data. Adjusted Cox regression models were used to estimate average and time-stratified adjusted hazard ratios (aHRs).Measurements and Main Results: Among 213,466 patients, 146,448 (68.6%) had any exacerbation; 119,124 (55.8%) had moderate exacerbations, and 27,324 (12.8%) had severe exacerbations. A total of 40,773 cardiovascular events were recorded. There was an immediate period of cardiovascular relative rate after any exacerbation (1-14 d; aHR, 3.19 [95% confidence interval (CI), 2.71-3.76]), followed by progressively declining yet maintained effects, elevated after one year (aHR, 1.84 [95% CI, 1.78-1.91]). Hazard ratios were highest 1-14 days after severe exacerbations (aHR, 14.5 [95% CI, 12.2-17.3]) but highest 14-30 days after moderate exacerbations (aHR, 1.94 [95% CI, 1.63-2.31]). Cardiovascular outcomes with the greatest two-week effects after a severe exacerbation were arrhythmia (aHR, 12.7 [95% CI, 10.3-15.7]) and heart failure (aHR, 8.31 [95% CI, 6.79-10.2]).Conclusions: Cardiovascular events after moderate COPD exacerbations occur slightly later than after severe exacerbations; heightened relative rates remain beyond one year irrespective of severity. The period immediately after an exacerbation presents a critical opportunity for clinical intervention and treatment optimization to prevent future cardiovascular events.


Assuntos
Doenças Cardiovasculares , Insuficiência Cardíaca , Doença Pulmonar Obstrutiva Crônica , Humanos , Progressão da Doença , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Arritmias Cardíacas , Insuficiência Cardíaca/epidemiologia , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/etiologia
3.
J Cardiovasc Electrophysiol ; 35(2): 267-277, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38073065

RESUMO

INTRODUCTION: Development of a rapid means to verify the ventricular tachycardia (VT) isthmus location from heart surface electrogram recordings would be a helpful tool for the electrophysiologist. METHOD: Myocardial infarction was induced in 22 canines by left anterior descending coronary artery ligation under general anesthesia. After 3-5 days, VT was inducible via programmed electrical stimulation at the anterior left ventricular epicardial surface. Bipolar VT electrograms were acquired from 196 to 312 recording sites using a multielectrode array. Electrograms were marked for activation time, and activation maps were constructed. The activation signal, or signature, is defined as the cumulative number of recording sites that have activated per millisecond, and it was utilized to segment each circuit into inner and outer circuit pathways, and as an estimate of best ablation lesion location to prevent VT. RESULTS: VT circuit components were differentiable by activation signals as: inner pathway (mean: 0.30 sites activating/ms) and outer pathway (mean: 2.68 sites activating/ms). These variables were linearly related (p < .001). Activation signal characteristics were dependent in part upon the isthmus exit site. The inner circuit pathway determined by the activation signal overlapped and often extended beyond the activation map isthmus location for each circuit. The best lesion location estimated by the activation signal would likely block an electrical impulse traveling through the isthmus, to prevent VT in all circuits. CONCLUSIONS: The activation signal algorithm, simple to implement for real-time computer display, approximates the VT isthmus location and shape as determined from activation marking, and best ablation lesion location to prevent reinduction.


Assuntos
Ablação por Cateter , Infarto do Miocárdio , Taquicardia Ventricular , Animais , Cães , Sistema de Condução Cardíaco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/cirurgia , Algoritmos
4.
Opt Express ; 32(5): 7521-7539, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38439431

RESUMO

The quantum digital signature protocol offers a replacement for most aspects of public-key digital signatures ubiquitous in today's digital world. A major advantage of a quantum-digital-signatures protocol is that it can have information-theoretic security, whereas public-key cryptography cannot. Here we demonstrate and characterize hardware to implement entanglement-based quantum digital signatures over our campus network. Over 25 hours, we collect measurements on our campus network, where we measure sufficiently low quantum bit error rates (<5% in most cases) which in principle enable quantum digital signatures at over 50 km as shown through rigorous simulation accompanied by a noise model developed specifically for our implementation. These results show quantum digital signatures can be successfully employed over deployed fiber. Moreover, our reported method provides great flexibility in the number of users, but with reduced entanglement rate per user. Finally, while the current implementation of our entanglement-based approach has a low signature rate, feasible upgrades would significantly increase the signature rate.

5.
J Cardiovasc Magn Reson ; 26(1): 101040, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38522522

RESUMO

BACKGROUND: Late gadolinium enhancement (LGE) of the myocardium has significant diagnostic and prognostic implications, with even small areas of enhancement being important. Distinguishing between definitely normal and definitely abnormal LGE images is usually straightforward, but diagnostic uncertainty arises when reporters are not sure whether the observed LGE is genuine or not. This uncertainty might be resolved by repetition (to remove artifact) or further acquisition of intersecting images, but this must take place before the scan finishes. Real-time quality assurance by humans is a complex task requiring training and experience, so being able to identify which images have an intermediate likelihood of LGE while the scan is ongoing, without the presence of an expert is of high value. This decision-support could prompt immediate image optimization or acquisition of supplementary images to confirm or refute the presence of genuine LGE. This could reduce ambiguity in reports. METHODS: Short-axis, phase-sensitive inversion recovery late gadolinium images were extracted from our clinical cardiac magnetic resonance (CMR) database and shuffled. Two, independent, blinded experts scored each individual slice for "LGE likelihood" on a visual analog scale, from 0 (absolute certainty of no LGE) to 100 (absolute certainty of LGE), with 50 representing clinical equipoise. The scored images were split into two classes-either "high certainty" of whether LGE was present or not, or "low certainty." The dataset was split into training, validation, and test sets (70:15:15). A deep learning binary classifier based on the EfficientNetV2 convolutional neural network architecture was trained to distinguish between these categories. Classifier performance on the test set was evaluated by calculating the accuracy, precision, recall, F1-score, and area under the receiver operating characteristics curve (ROC AUC). Performance was also evaluated on an external test set of images from a different center. RESULTS: One thousand six hundred and forty-five images (from 272 patients) were labeled and split at the patient level into training (1151 images), validation (247 images), and test (247 images) sets for the deep learning binary classifier. Of these, 1208 images were "high certainty" (255 for LGE, 953 for no LGE), and 437 were "low certainty". An external test comprising 247 images from 41 patients from another center was also employed. After 100 epochs, the performance on the internal test set was accuracy = 0.94, recall = 0.80, precision = 0.97, F1-score = 0.87, and ROC AUC = 0.94. The classifier also performed robustly on the external test set (accuracy = 0.91, recall = 0.73, precision = 0.93, F1-score = 0.82, and ROC AUC = 0.91). These results were benchmarked against a reference inter-expert accuracy of 0.86. CONCLUSION: Deep learning shows potential to automate quality control of late gadolinium imaging in CMR. The ability to identify short-axis images with intermediate LGE likelihood in real-time may serve as a useful decision-support tool. This approach has the potential to guide immediate further imaging while the patient is still in the scanner, thereby reducing the frequency of recalls and inconclusive reports due to diagnostic indecision.


Assuntos
Meios de Contraste , Aprendizado Profundo , Interpretação de Imagem Assistida por Computador , Valor Preditivo dos Testes , Humanos , Meios de Contraste/administração & dosagem , Reprodutibilidade dos Testes , Interpretação de Imagem Assistida por Computador/normas , Bases de Dados Factuais , Miocárdio/patologia , Masculino , Feminino , Imagem Cinética por Ressonância Magnética/normas , Pessoa de Meia-Idade , Cardiopatias/diagnóstico por imagem , Garantia da Qualidade dos Cuidados de Saúde/normas , Variações Dependentes do Observador , Idoso , Imageamento por Ressonância Magnética/normas
6.
BMC Pulm Med ; 24(1): 221, 2024 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-38704538

RESUMO

BACKGROUND: An immediate, temporal risk of heart failure and arrhythmias after a Chronic Obstructive Pulmonary Disease (COPD) exacerbation has been demonstrated, particularly in the first month post-exacerbation. However, the clinical profile of patients who develop heart failure (HF) or atrial fibrillation/flutter (AF) following exacerbation is unclear. Therefore we examined factors associated with people being hospitalized for HF or AF, respectively, following a COPD exacerbation. METHODS: We conducted two nested case-control studies, using primary care electronic healthcare records from the Clinical Practice Research Datalink Aurum linked to Hospital Episode Statistics, Office for National Statistics for mortality, and socioeconomic data (2014-2020). Cases had hospitalization for HF or AF within 30 days of a COPD exacerbation, with controls matched by GP practice (HF 2:1;AF 3:1). We used conditional logistic regression to explore demographic and clinical factors associated with HF and AF hospitalization. RESULTS: Odds of HF hospitalization (1,569 cases, 3,138 controls) increased with age, type II diabetes, obesity, HF and arrhythmia history, exacerbation severity (hospitalization), most cardiovascular medications, GOLD airflow obstruction, MRC dyspnea score, and chronic kidney disease. Strongest associations were for severe exacerbations (adjusted odds ratio (aOR)=6.25, 95%CI 5.10-7.66), prior HF (aOR=2.57, 95%CI 1.73-3.83), age≥80 years (aOR=2.41, 95%CI 1.88-3.09), and prior diuretics prescription (aOR=2.81, 95%CI 2.29-3.45). Odds of AF hospitalization (841 cases, 2,523 controls) increased with age, male sex, severe exacerbation, arrhythmia and pulmonary hypertension history and most cardiovascular medications. Strongest associations were for severe exacerbations (aOR=5.78, 95%CI 4.45-7.50), age≥80 years (aOR=3.15, 95%CI 2.26-4.40), arrhythmia (aOR=3.55, 95%CI 2.53-4.98), pulmonary hypertension (aOR=3.05, 95%CI 1.21-7.68), and prescription of anticoagulants (aOR=3.81, 95%CI 2.57-5.64), positive inotropes (aOR=2.29, 95%CI 1.41-3.74) and anti-arrhythmic drugs (aOR=2.14, 95%CI 1.10-4.15). CONCLUSIONS: Cardiopulmonary factors were associated with hospitalization for HF in the 30 days following a COPD exacerbation, while only cardiovascular-related factors and exacerbation severity were associated with AF hospitalization. Understanding factors will help target people for prevention.


Assuntos
Fibrilação Atrial , Flutter Atrial , Insuficiência Cardíaca , Hospitalização , Doença Pulmonar Obstrutiva Crônica , Humanos , Masculino , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Doença Pulmonar Obstrutiva Crônica/complicações , Feminino , Estudos de Casos e Controles , Idoso , Fibrilação Atrial/epidemiologia , Insuficiência Cardíaca/epidemiologia , Flutter Atrial/epidemiologia , Pessoa de Meia-Idade , Fatores de Risco , Idoso de 80 Anos ou mais , Hospitalização/estatística & dados numéricos , Progressão da Doença , Modelos Logísticos
7.
J Physiol ; 601(8): 1353-1370, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36866700

RESUMO

Optical mapping is a widely used tool to record and visualize the electrophysiological properties in a variety of myocardial preparations such as Langendorff-perfused isolated hearts, coronary-perfused wedge preparations, and cell culture monolayers. Motion artifact originating from the mechanical contraction of the myocardium creates a significant challenge to performing optical mapping of contracting hearts. Hence, to minimize the motion artifact, cardiac optical mapping studies are mostly performed on non-contracting hearts, where the mechanical contraction is removed using pharmacological excitation-contraction uncouplers. However, such experimental preparations eliminate the possibility of electromechanical interaction, and effects such as mechano-electric feedback cannot be studied. Recent developments in computer vision algorithms and ratiometric techniques have opened the possibility of performing optical mapping studies on isolated contracting hearts. In this review, we discuss the existing techniques and challenges of optical mapping of contracting hearts.


Assuntos
Coração , Miocárdio , Potenciais de Ação/fisiologia , Coração/diagnóstico por imagem , Coração/fisiologia
8.
J Cardiovasc Electrophysiol ; 34(11): 2305-2315, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37681403

RESUMO

INTRODUCTION: Measurement of the spatial ventricular gradient (SVG), spatial QRST angles, and other vectorcardiographic measures of myocardial electrical heterogeneity have emerged as novel risk stratification methods for sudden cardiac death and other adverse cardiovascular events. Prior studies of normal limits of these measurements included primarily young, healthy, White volunteers, but normal limits in older patients are unknown. The influence of race and body mass index (BMI) on these measurements is also unclear. METHODS: Normal 12-lead electrocardiograms (ECGs) from a single center were identified. Patients with abnormal cardiovascular, pulmonary, or renal history (assessed by International Classification of Disease [ICD-9/ICD-10] codes) or abnormal cardiovascular imaging were excluded. The SVG and QRST angles were measured and stratified by age, sex, and race. Multivariable linear regression was used to assess the influence of age, BMI, and heart rate (HR) on these measurements. RESULTS: Among 3292 patients, observed ranges of SVG and QRST angles (peak and mean) differed significantly based on sex, age, and race. Sex differences attenuated with increasing age. Men tended to have larger SVG magnitude (60.4 [46.1-77.8] vs. 52.5 [41.3-65.8] mv*ms, p < .0001) and elevation, and more anterior/negative SVG azimuth (-14.8 [-25.1 to -4.3] vs. 1.3 [-9.8 to 10.5] deg, p < .0001) compared to women. Men also had wider QRST angles. Observed ranges varied significantly with BMI and HR. SVG and QRST angle measurements were robust to different filtering bandwidths and moderate fiducial point annotation errors, but were heavily affected by changes in baseline correction. CONCLUSIONS: Age, sex, race, BMI, and HR significantly affect the range of SVG and QRST angles in patients with normal ECGs and no known cardiovascular disease, and should be accounted for in future studies. An online calculator for prediction of these "normal limits" given demographics is provided at https://bivectors.github.io/gehcalc/.


Assuntos
Doenças Cardiovasculares , Humanos , Masculino , Feminino , Idoso , Eletrocardiografia/métodos , Morte Súbita Cardíaca , Frequência Cardíaca , Ventrículos do Coração
9.
Opt Express ; 31(3): 3881-3896, 2023 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-36785370

RESUMO

This paper investigates the effects of a nuclear-disturbed environment on the transmission of electromagnetic (EM) waves through the atmosphere. An atmospheric nuclear detonation can produce heightened free electron densities in the surrounding atmosphere that can disrupt EM waves that propagate through the disturbed region. Radiation transport models simulated the ionization and free electron densities created in the atmosphere from a 1 MT detonation at heights of burst of 5 km, 25 km, and 75 km. Recombination rates for the free electrons in the atmosphere were applied, from previous work in the literature, to determine the nuclear-induced electron densities as a function of time and space after the detonation. A ray-tracing algorithm was applied to determine the refraction and reflection of waves propagating in the different nuclear-disturbed environments. The simulation results show that the free electron plasma created from an atmospheric nuclear detonation depend on the height of burst of the weapon, the weapon yield, and the time after detonation. Detonations at higher altitudes produce higher free electron densities for greater durations and over larger ranges. The larger the free electron densities, the greater the impact on EM wavelengths in regards to refraction, reflection, and absorption in the atmosphere. An analysis of modern infrastructure and the effects of nuclear-disturbed atmospheres on different signal wavelengths and systems is discussed.

10.
Opt Express ; 31(1): 512, 2023 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-36606986

RESUMO

We correct typographical errors in Eq. (15) in [Opt. Express30, 15184 (2022)10.1364/OE.456597] [1]. These errors were not present in the actual formulas used to calculate the results of the paper, so all results remain unaffected.

11.
Opt Express ; 31(16): 26254-26275, 2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37710490

RESUMO

Squeezed light is a crucial resource for continuous-variable (CV) quantum information science. Distributed multi-mode squeezing is critical for enabling CV quantum networks and distributed quantum sensing. To date, multi-mode squeezing measured by homodyne detection has been limited to single-room experiments without coexisting classical signals, i.e., on "dark" fiber. Here, after distribution through separate fiber spools (5 km), -0.9 ± 0.1-dB coexistent two-mode squeezing is measured. Moreover, after distribution through separate deployed campus fibers (about 250 m and 1.2 km), -0.5 ± 0.1-dB coexistent two-mode squeezing is measured. Prior to distribution, the squeezed modes are each frequency multiplexed with several classical signals-including the local oscillator and conventional network signals-demonstrating that the squeezed modes do not need dedicated dark fiber. After distribution, joint two-mode squeezing is measured and recorded for post-processing using triggered homodyne detection in separate locations. This demonstration enables future applications in quantum networks and quantum sensing that rely on distributed multi-mode squeezing.

12.
Opt Lett ; 48(22): 6031-6034, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37966781

RESUMO

We generate ultrabroadband photon pairs entangled in both polarization and frequency bins through an all-waveguided Sagnac source covering the entire optical C- and L-bands (1530-1625 nm). We perform comprehensive characterization of high-fidelity states in multiple dense wavelength-division multiplexed channels, achieving full tomography of effective four-qubit systems. Additionally, leveraging the inherent high dimensionality of frequency encoding and our electro-optic measurement approach, we demonstrate the scalability of our system to higher dimensions, reconstructing states in a 36-dimensional Hilbert space consisting of two polarization qubits and two frequency-bin qutrits. Our findings hold potential significance for quantum networking, particularly dense coding and entanglement distillation in wavelength-multiplexed quantum networks.

13.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-36942430

RESUMO

While sudden cardiac death (SCD) in hypertrophic cardiomyopathy (HCM) is due to arrhythmias, the guidelines for prediction of SCD are based solely on non-electrophysiological methods. This study aims to stimulate thinking about whether the interests of patients with HCM are better served by using current, 'risk factor', methods of prediction or by further development of electrophysiological methods to determine arrhythmic risk. Five published predictive studies of SCD in HCM, which contain sufficient data to permit analysis, were analysed to compute receiver operating characteristics together with their confidence bounds to compare their formal prediction either by bootstrapping or Monte Carlo analysis. Four are based on clinical risk factors, one with additional MRI analysis, and were regarded as exemplars of the risk factor approach. The other used an electrophysiological method and directly compared this method to risk factors in the same patients. Prediction methods that use conventional clinical risk factors and MRI have low predictive capacities that will only detect 50-60% of patients at risk with a 15-30% false positive rate [area under the curve (AUC) = ∼0.7], while the electrophysiological method detects 90% of events with a 20% false positive rate (AUC = ∼0.89). Given improved understanding of complex arrhythmogenesis, arrhythmic SCD is likely to be more accurately predictable using electrophysiologically based approaches as opposed to current guidelines and should drive further development of electrophysiologically based methods.


Assuntos
Arritmias Cardíacas , Cardiomiopatia Hipertrófica , Humanos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/complicações , Fatores de Risco , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Curva ROC
14.
Europace ; 25(3): 1060-1067, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36734205

RESUMO

AIMS: Left bundle branch area pacing (LBBAP) is a promising method for delivering cardiac resynchronization therapy (CRT), but its relative physiological effectiveness compared with His bundle pacing (HBP) is unknown. We conducted a within-patient comparison of HBP, LBBAP, and biventricular pacing (BVP). METHODS AND RESULTS: Patients referred for CRT were recruited. We assessed electrical response using non-invasive mapping, and acute haemodynamic response using a high-precision haemodynamic protocol. Nineteen patients were recruited: 14 male, mean LVEF of 30%. Twelve had time for BVP measurements. All three modalities reduced total ventricular activation time (TVAT), (ΔTVATHBP -43 ± 14 ms and ΔTVATLBBAP -35 ± 20 ms vs. ΔTVATBVP -19 ± 30 ms, P = 0.03 and P = 0.1, respectively). HBP produced a significantly greater reduction in TVAT compared with LBBAP in all 19 patients (-46 ± 15 ms, -36 ± 17 ms, P = 0.03). His bundle pacing and LBBAP reduced left ventricular activation time (LVAT) more than BVP (ΔLVATHBP -43 ± 16 ms, P < 0.01 vs. BVP, ΔLVATLBBAP -45 ± 17 ms, P < 0.01 vs. BVP, ΔLVATBVP -13 ± 36 ms), with no difference between HBP and LBBAP (P = 0.65). Acute systolic blood pressure was increased by all three modalities. In the 12 with BVP, greater improvement was seen with HBP and LBBAP (6.4 ± 3.8 mmHg BVP, 8.1 ± 3.8 mmHg HBP, P = 0.02 vs. BVP and 8.4 ± 8.2 mmHg for LBBAP, P = 0.3 vs. BVP), with no difference between HBP and LBBAP (P = 0.8). CONCLUSION: HBP delivered better ventricular resynchronization than LBBAP because right ventricular activation was slower during LBBAP. But LBBAP was not inferior to HBP with respect to LV electrical resynchronization and acute haemodynamic response.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Fascículo Atrioventricular , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Eletrocardiografia/métodos , Resultado do Tratamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Hemodinâmica , Estimulação Cardíaca Artificial/métodos
15.
Europace ; 25(2): 726-738, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36260428

RESUMO

AIMS: The response to high frequency stimulation (HFS) is used to locate putative sites of ganglionated plexuses (GPs), which are implicated in triggering atrial fibrillation (AF). To identify topological and immunohistochemical characteristics of presumed GP sites functionally identified by HFS. METHODS AND RESULTS: Sixty-three atrial sites were tested with HFS in four Langendorff-perfused porcine hearts. A 3.5 mm tip quadripolar ablation catheter was used to stimulate and deliver HFS to the left and right atrial epicardium, within the local atrial refractory period. Tissue samples from sites triggering atrial ectopy/AF (ET) sites and non-ET sites were stained with choline acetyltransferase (ChAT) and tyrosine hydroxylase (TH), for quantification of parasympathetic and sympathetic nerves, respectively. The average cross-sectional area (CSA) of nerves was also calculated. Histomorphometry of six ET sites (9.5%) identified by HFS evoking at least a single atrial ectopic was compared with non-ET sites. All ET sites contained ChAT-immunoreactive (ChAT-IR) and/or TH-immunoreactive nerves (TH-IR). Nerve density was greater in ET sites compared to non-ET sites (nerves/cm2: 162.3 ± 110.9 vs. 69.65 ± 72.48; P = 0.047). Overall, TH-IR nerves had a larger CSA than ChAT-IR nerves (µm2: 11 196 ± 35 141 vs. 2070 ± 5841; P < 0.0001), but in ET sites, TH-IR nerves were smaller than in non-ET sites (µm2: 6021 ± 14 586 vs. 25 254 ± 61 499; P < 0.001). CONCLUSIONS: ET sites identified by HFS contained a higher density of smaller nerves than non-ET sites. The majority of these nerves were within the atrial myocardium. This has important clinical implications for devising an effective therapeutic strategy for targeting autonomic triggers of AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Animais , Suínos , Fibrilação Atrial/cirurgia , Átrios do Coração , Miocárdio , Sistema Nervoso Autônomo , Ablação por Cateter/métodos
16.
Europace ; 25(3): 863-872, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36576323

RESUMO

AIMS: There is rising healthcare utilization related to the increasing incidence and prevalence of atrial fibrillation (AF) worldwide. Simplifying therapy and reducing hospital episodes would be a valuable development. The efficacy of a streamlined AF ablation approach was compared to drug therapy and a conventional catheter ablation technique for symptom control in paroxysmal AF. METHODS AND RESULTS: We recruited 321 patients with symptomatic paroxysmal AF to a prospective randomized, multi-centre, open label trial at 13 UK hospitals. Patients were randomized 1:1:1 to cryo-balloon ablation without electrical mapping with patients discharged same day [Ablation Versus Anti-arrhythmic Therapy for Reducing All Hospital Episodes from Recurrent (AVATAR) protocol]; optimization of drug therapy; or cryo-balloon ablation with confirmation of pulmonary vein isolation and overnight hospitalization. The primary endpoint was time to any hospital episode related to treatment for atrial arrhythmia. Secondary endpoints included complications of treatment and quality-of-life measures. The hazard ratio (HR) for a primary endpoint event occurring when comparing AVATAR protocol arm to drug therapy was 0.156 (95% CI, 0.097-0.250; P < 0.0001 by Cox regression). Twenty-three patients (21%) recorded an endpoint event in the AVATAR arm compared to 76 patients (74%) within the drug therapy arm. Comparing AVATAR and conventional ablation arms resulted in a non-significant HR of 1.173 (95% CI, 0.639-2.154; P = 0.61 by Cox regression) with 23 patients (21%) and 19 patients (18%), respectively, recording primary endpoint events (P = 0.61 by log-rank test). CONCLUSION: The AVATAR protocol was superior to drug therapy for avoiding hospital episodes related to AF treatment, but conventional cryoablation was not superior to the AVATAR protocol. This could have wide-ranging implications on how demand for AF symptom control is met. TRIAL REGISTRATION: Clinical Trials Registration: NCT02459574.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Antiarrítmicos/efeitos adversos , Resultado do Tratamento , Estudos Prospectivos , Hospitais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
17.
Europace ; 25(10)2023 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-37815462

RESUMO

AIMS: Left bundle branch pacing (LBBP) can deliver physiological left ventricular activation, but typically at the cost of delayed right ventricular (RV) activation. Right ventricular activation can be advanced through anodal capture, but there is uncertainty regarding the mechanism by which this is achieved, and it is not known whether this produces haemodynamic benefit. METHODS AND RESULTS: We recruited patients with LBBP leads in whom anodal capture eliminated the terminal R-wave in lead V1. Ventricular activation pattern, timing, and high-precision acute haemodynamic response were studied during LBBP with and without anodal capture. We recruited 21 patients with a mean age of 67 years, of whom 14 were males. We measured electrocardiogram timings and haemodynamics in all patients, and in 16, we also performed non-invasive mapping. Ventricular epicardial propagation maps demonstrated that RV septal myocardial capture, rather than right bundle capture, was the mechanism for earlier RV activation. With anodal capture, QRS duration and total ventricular activation times were shorter (116 ± 12 vs. 129 ± 14 ms, P < 0.01 and 83 ± 18 vs. 90 ± 15 ms, P = 0.01). This required higher outputs (3.6 ± 1.9 vs. 0.6 ± 0.2 V, P < 0.01) but without additional haemodynamic benefit (mean difference -0.2 ± 3.8 mmHg compared with pacing without anodal capture, P = 0.2). CONCLUSION: Left bundle branch pacing with anodal capture advances RV activation by stimulating the RV septal myocardium. However, this requires higher outputs and does not improve acute haemodynamics. Aiming for anodal capture may therefore not be necessary.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Masculino , Humanos , Idoso , Feminino , Estimulação Cardíaca Artificial/métodos , Sistema de Condução Cardíaco , Hemodinâmica , Ventrículos do Coração , Eletrocardiografia/métodos
18.
Pacing Clin Electrophysiol ; 46(9): 1077-1084, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37594233

RESUMO

BACKGROUND: The use of left bundle branch area pacing (LBBAP) for bradycardia pacing and cardiac resynchronization is increasing, but implants are not always successful. We prospectively studied consecutive patients to determine whether septal scar contributes to implant failure. METHODS: Patients scheduled for bradycardia pacing or cardiac resynchronization therapy were prospectively enrolled. Recruited patients underwent preprocedural scar assessment by cardiac MRI with late gadolinium enhancement imaging. LBBAP was attempted using a lumenless lead (Medtronic 3830) via a transeptal approach. RESULTS: Thirty-five patients were recruited: 29 male, mean age 68 years, 10 ischemic, and 16 non-ischemic cardiomyopathy. Pacing indication was bradycardia in 26% and cardiac resynchronization in 74%. The lead was successfully deployed to the left ventricular septum in 30/35 (86%) and unsuccessful in the remaining 5/35 (14%). Septal late gadolinium enhancement was significantly less extensive in patients where left septal lead deployment was successful, compared those where it was unsuccessful (median 8%, IQR 2%-18% vs. median 54%, IQR 53%-57%, p < .001). CONCLUSIONS: The presence of septal scar appears to make it more challenging to deploy a lead to the left ventricular septum via the transeptal route. Additional implant tools or alternative approaches may be required in patients with extensive septal scar.


Assuntos
Septo Interventricular , Humanos , Masculino , Idoso , Septo Interventricular/diagnóstico por imagem , Bradicardia , Cicatriz , Meios de Contraste , Gadolínio
19.
Appl Opt ; 62(23): G60-G68, 2023 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-37707064

RESUMO

Space-based quantum networks provide a means for near-term long-distance transmission of quantum information. This article analyzed the performance of a downlink quantum network between a low-Earth-orbit satellite and an observatory operating in less-than-ideal atmospheric conditions. The effects from fog, haze, and a nuclear disturbed environment on the long-range distribution of quantum states were investigated. A density matrix that estimates the quantum state by capturing the effects from increased signal loss and elevated background noise to estimate the state fidelity of the transmitted quantum state was developed. It was found that the nuclear disturbed environment and other atmospheric effects have a degrading effect on the quantum state. These environments impede the ability to perform quantum communications for the duration of the effects. In the case of the nuclear disturbed environment, the nuclear effects subside quickly, and network performance should return to normal by the next satellite pass.

20.
Sensors (Basel) ; 23(24)2023 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-38139664

RESUMO

Hydropower facilities are often remotely monitored or controlled from a centralized remote control room. Additionally, major component manufacturers monitor the performance of installed components, increasingly via public communication infrastructures. While these communications enable efficiencies and increased reliability, they also expand the cyber-attack surface. Communications may use the internet to remote control a facility's control systems, or it may involve sending control commands over a network from a control room to a machine. The content could be encrypted and decrypted using a public key to protect the communicated information. These cryptographic encoding and decoding schemes become vulnerable as more advances are made in computer technologies, such as quantum computing. In contrast, quantum key distribution (QKD) and other quantum cryptographic protocols are not based upon a computational problem, and offer an alternative to symmetric cryptography in some scenarios. Although the underlying mechanism of quantum cryptogrpahic protocols such as QKD ensure that any attempt by an adversary to observe the quantum part of the protocol will result in a detectable signature as an increased error rate, potentially even preventing key generation, it serves as a warning for further investigation. In QKD, when the error rate is low enough and enough photons have been detected, a shared private key can be generated known only to the sender and receiver. We describe how this novel technology and its several modalities could benefit the critical infrastructures of dams or hydropower facilities. The presented discussions may be viewed as a precursor to a quantum cybersecurity roadmap for the identification of relevant threats and mitigation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA