Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Europace ; 23(11): 1751-1756, 2021 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-34534277

RESUMO

AIMS: Data regarding the efficacy of catheter ablation in heart failure patients with severely dilated left atrium and reduced left ventricular ejection fraction (LVEF) are scanty. We sought to assess the efficacy of catheter ablation in patients with reduced LVEF and severe left atrial (LA) enlargement, and to compare it to those patients with preserved left ventricular function and equally dilated left atrium. METHODS AND RESULTS: Three patient groups with paroxysmal or persistent atrial fibrillation (AF) undergoing a first pulmonary vein isolation (PVI) were considered: Group 1 included patients with normal or mildly abnormal LA volume (≤41 mL/m2) and normal LVEF; Group 2 included patients with severe LA enlargement (>48 mL/m2) and normal LVEF; and Group 3 included patients with severe LA enlargement and reduced LVEF. Time to event analysis was used to investigate AF recurrences. The study cohort includes 439 patients; Group 3 had a higher prevalence of cardiovascular risk factors. LA enlargement was associated with a two-fold in risk of AF recurrence, on the contrary only a smaller non-significant increase of 30% was shown with the further addition of LVEF reduction. CONCLUSIONS: The long-term outcome of patients with severe LA dilatation and reduced LVEF is comparable to those with severe LA enlargement but preserved LVEF. Long-term efficacy of PVI is certainly affected by the enlargement of the left atrium, but less so by the addition of a reduced LVEF. CA remains the best strategy for rhythm control both in paroxysmal and persistent AF in this subgroup of patients.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Veias Pulmonares/cirurgia , Recidiva , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
2.
Europace ; 19(8): 1349-1356, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-27702861

RESUMO

AIMS: Patients receiving cardiac resynchronization therapy defibrillators (CRT-Ds) are likely to undergo one or more device replacements, mainly for battery depletion. We assessed the economic impact of battery depletion on the overall cost of CRT-D treatment from the perspectives of the healthcare system and the hospital. We also compared devices of different generations and from different manufacturers in terms of therapy cost. METHODS AND RESULTS: We analysed data on 1792 CRT-Ds implanted in 1399 patients in 9 Italian centres. We calculated the replacement probability and the total therapy cost over 6 years, stratified by device generation and manufacturer. Public tariffs from diagnosis-related groups were used together with device prices and hospitalization costs. Generators were from 3 manufacturers: Boston Scientific (667, 37%), Medtronic (973, 54%), and St Jude Medical (152, 9%). The replacement probability at 6 years was 83 and 68% for earlier- and recent-generation devices, respectively. The need for replacement increased total therapy costs by more than 50% over the initial implantation cost for hospitals and by more than 30% for healthcare system. The improved longevity of recent-generation CRT-Ds reduced the therapy cost by ∼6% in both perspectives. Among recent-generation CRT-Ds, the replacement probability of devices from different manufacturers ranged from 12 to 70%. Consequently, the maximum difference in therapy cost between manufacturers was 40% for hospitals and 19% for the healthcare system. CONCLUSIONS: Differences in CRT-D longevity strongly affect the overall therapy cost. While the use of recent-generation devices has reduced the cost, significant differences exist among currently available systems.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/economia , Terapia de Ressincronização Cardíaca/economia , Desfibriladores Implantáveis/economia , Remoção de Dispositivo/economia , Cardioversão Elétrica/economia , Cardioversão Elétrica/instrumentação , Fontes de Energia Elétrica/economia , Custos de Cuidados de Saúde , Insuficiência Cardíaca/economia , Insuficiência Cardíaca/terapia , Redução de Custos , Análise Custo-Benefício , Bases de Dados Factuais , Cardioversão Elétrica/efeitos adversos , Desenho de Equipamento , Falha de Equipamento , Gastos em Saúde , Insuficiência Cardíaca/diagnóstico , Humanos , Itália , Modelos Econômicos , Fatores de Tempo
3.
Europace ; 17(8): 1251-8, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25976906

RESUMO

AIMS: Device replacement at the time of battery depletion of implantable cardioverter-defibrillators (ICDs) may carry a considerable risk of complications and engenders costs for healthcare systems. Therefore, ICD device longevity is extremely important both from a clinical and economic standpoint. Cardiac resynchronization therapy defibrillators (CRT-D) battery longevity is shorter than ICDs. We determined the rate of replacements for battery depletion and we identified possible determinants of early depletion in a series of patients who had undergone implantation of CRT-D devices. METHODS AND RESULTS: We retrieved data on 1726 consecutive CRT-D systems implanted from January 2008 to March 2010 in nine centres. Five years after a successful CRT-D implantation procedure, 46% of devices were replaced due to battery depletion. The time to device replacement for battery depletion differed considerably among currently available CRT-D systems from different manufacturers, with rates of batteries still in service at 5 years ranging from 52 to 88% (log-rank test, P < 0.001). Left ventricular lead output and unipolar pacing configuration were independent determinants of early depletion [hazard ratio (HR): 1.96; 95% 95% confidence interval (CI): 1.57-2.46; P < 0.001 and HR: 1.58, 95% CI: 1.25-2.01; P < 0.001, respectively]. The implantation of a recent-generation device (HR: 0.57; 95% CI: 0.45-0.72; P < 0.001), the battery chemistry and the CRT-D manufacturer (HR: 0.64; 95% CI: 0.47-0.89; P = 0.008) were additional factors associated with replacement for battery depletion. CONCLUSION: The device longevity at 5 years was 54%. High left ventricular lead output and unipolar pacing configuration were associated with early battery depletion, while recent-generation CRT-Ds displayed better longevity. Significant differences emerged among currently available CRT-D systems from different manufacturers.


Assuntos
Desfibriladores Implantáveis/classificação , Desfibriladores Implantáveis/estatística & dados numéricos , Remoção de Dispositivo/estatística & dados numéricos , Fontes de Energia Elétrica/estatística & dados numéricos , Insuficiência Cardíaca/prevenção & controle , Indústrias/estatística & dados numéricos , Dispositivos de Terapia de Ressincronização Cardíaca/classificação , Dispositivos de Terapia de Ressincronização Cardíaca/estatística & dados numéricos , Fontes de Energia Elétrica/classificação , Desenho de Equipamento , Falha de Equipamento , Análise de Falha de Equipamento/métodos , Análise de Falha de Equipamento/estatística & dados numéricos , Insuficiência Cardíaca/epidemiologia , Humanos , Itália/epidemiologia , Avaliação da Tecnologia Biomédica/métodos , Avaliação da Tecnologia Biomédica/estatística & dados numéricos
4.
Pacing Clin Electrophysiol ; 38(2): 187-95, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25469451

RESUMO

BACKGROUND: Accuracy in left atrial (LA) anatomical reconstruction is crucial to the safe and effective performance of catheter ablation of atrial fibrillation (AF). The aim of this study was to evaluate the accuracy of LA reconstruction performed with intracardiac echocardiography (ICE) as compared to fast anatomical mapping (FAM) both integrated in the CARTO mapping system (Biosense Webster, Diamond Bar, CA, USA). METHODS: A multislice computed tomography (MSCT) was preacquired from 29 patients with AF who underwent catheter ablation and 3D-LA geometry was reconstructed using both ICE and FAM separately. The accuracy of the LA anatomical definition was evaluated by comparing LA volumes, LA and pulmonary vein (PV) diameters obtained using ICE and FAM versus MSCT (gold standard). RESULTS: Anterior-posterior and superior-inferior LA diameters were shorter in ICE versus MSCT (32 ± 10 vs 46 ± 9 mm and 48 ± 7 vs 53 ± 7 mm, P < 0.01) but similar in FAM versus MSCT (45 ± 9 vs 46 ± 9 mm and 52 ± 10 vs 53 ± 7 mm). Latero-septal LA diameter was similar in ICE versus MSCT (63 ± 11 vs 63 ± 9 mm) but larger in FAM versus MSCT (69 ± 9 vs 63 ± 9 mm, P < 0.001). LA volume was lower in ICE versus MSCT (73 ± 30 mL vs 116 ± 45 mL, P < 0.0001) and slightly larger in FAM versus MSCT (132 ± 45 vs 116 ± 45 mL, P = 0.06). PV diameters were similar in FAM versus MSCT but significantly underestimated with ICE. CONCLUSIONS: Overall accuracy in the LA and PV anatomical reconstruction was found to be superior with FAM compared to ICE-guided approach. ICE resulted in a significant underestimate of both LA and PV dimensions, while FAM slightly overestimated LA geometry.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Ecocardiografia Tridimensional/métodos , Cirurgia Assistida por Computador/métodos , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
5.
Circ J ; 78(9): 2232-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24954238

RESUMO

BACKGROUND: Pro-inflammatory cytokines contribute to the pathophysiology of heart failure (HF) and are up-regulated in affected patients. We investigated whether pro-inflammatory cytokines might predict the response to cardiac resynchronization therapy (CRT). METHODS AND RESULTS: Plasma levels of tumor necrosis factor-α (TNF-α) and interleukin-6 were assessed in 91 patients before CRT. Response to CRT was defined as a decrease ≥15% in left ventricular end-systolic volume (LVESV) at 6 months. Baseline TNF-α did correlate with LVESV reduction (P=0.001) after CRT. The subject group was divided according to tertiles of TNF-α. From the lower to the upper tertile LVESV (-31±28%, -17±17%, -9±22%) and LV end-diastolic volume (-23±25%, -14±16%, -4±18%) were progressively less reduced after CRT (P<0.001). The proportion of responders to CRT was 70%, 42% and 33%, according to the lower, intermediate and upper tertile of TNF-α distribution (P=0.01). Serious cardiac events (cardiac death, HF hospitalization or urgent heart transplantation) occurred in 63% of patients in the upper tertile vs. 32% and 17% in the intermediate and lower tertiles, respectively, during a median follow-up of 47 months (P<0.001). CONCLUSIONS: Circulating TNF-α predicts the degree of LV reverse remodeling after CRT and may contribute to the early identification of those patients at higher risk of events after device implantation.


Assuntos
Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/terapia , Fator de Necrose Tumoral alfa/sangue , Remodelação Ventricular , Idoso , Terapia de Ressincronização Cardíaca , Doença Crônica , Morte , Feminino , Seguimentos , Transplante de Coração , Humanos , Interleucina-6/sangue , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
6.
Clin Cardiol ; 45(6): 670-678, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35502643

RESUMO

AIMS: HeartLogic algorithm combines data from multiple implantable defibrillators (ICD)-based sensors to predict impending heart failure (HF) decompensation. A treatment protocol to manage algorithm alerts is not yet known, although decongestive treatment adjustments are the most frequent alert-triggered actions reported in clinical practice. We describe the implementation of HeartLogic for remote monitoring of HF patients, and we evaluate the approach to diuretic dosing and timing of the intervention in patients with device alerts. METHODS: The algorithm was activated in 229 ICD patients at eight centers. The median follow-up was 17 months (25th-75th percentile: 11-24). Remote data reviews and patient phone contacts were undertaken at the time of HeartLogic alerts, to assess the patient's status and to prevent HF worsening. We analyzed alert-triggered augmented HF treatments, consisting of isolated increases in diuretics dosage. RESULTS: We reported 242 alerts (0.8 alerts/patient-year) in 123 patients, 137 (56%) alerts triggered clinical actions to treat HF. The HeartLogic index decreased after the 56 actions consisting of diuretics increase. Specifically, alerts resolved more quickly when the increases in dosing of diuretics were early rather than late: 28 days versus 62 days, p < .001. The need of hospitalization for further treatments to resolve the alert condition was associated with higher HeartLogic index values on the day of the diuretics increase (odds ratio: 1.11, 95% CI: 1.02-1.20, p = .013) and with late interventions (odds ratio: 5.11, 95% CI: 1.09-24.48, p = .041). No complications were reported after drug adjustments. CONCLUSIONS: Decongestive treatment adjustments triggered by alerts seem safe and effective. The early use of decongestive treatment and the use of high doses of diuretics seem to be associated with more favorable outcomes.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Algoritmos , Terapia de Ressincronização Cardíaca/métodos , Diuréticos/uso terapêutico , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos
7.
Pacing Clin Electrophysiol ; 34(4): 475-83, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21208240

RESUMO

BACKGROUND: An increased risk of delayed cardiac perforation (DCP) with active-fixation small-diameter ICD leads has recently been reported, especially with regard to the St. Jude Riata lead (St. Jude Medical, Sylmar, CA, USA). Few data on the risk of DCP in small versus standard-diameter leads implanted in a single high-volume center are available. Moreover, no data on the performances of St. Jude's new small-diameter Durata lead are as yet available. The aim of this study was to assess the incidence of DCP in small versus standard-diameter leads implanted in our center. METHODS: Between January 2003 and October 2009, 437 small-diameter leads (190 Medtronic Sprint Fidelis [Medtronic Inc., Minneapolis, MN, USA], 196 Riata, 51 Durata) and 421 standard-diameter (>8 Fr) leads were implanted. RESULTS: After a median follow-up of 421 days seven of 858 (0.8%) patients experienced DCP. The incidence of DCP was higher in patients with small-diameter leads than in those with standard-diameter leads (1.6% vs 0%, P = 0.01). No cases of DCP occurred among 371 passive-fixation leads versus 1.4% of events among active-fixation leads (P = 0.02). The incidence of DCP was 2.5% in Riata, 1% in Sprint Fidelis, 0% in Durata, and 0% in standard-diameter leads (P < 0.01 for Riata vs standard-diameter leads). CONCLUSIONS: Small-diameter active-fixation ICD leads are at increased risk of DCP, a finding mostly due to the higher incidence of events in the Riata family. By contrast, passive-fixation small-diameter leads and standard-diameter leads appear to be safe enough regarding the risk of DCP. Our preliminary data suggest that the new Durata lead is not associated with an increased risk of DCP.


Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Eletrodos Implantados/estatística & dados numéricos , Traumatismos Cardíacos/epidemiologia , Complicações Pós-Operatórias/mortalidade , Ferimentos Penetrantes/epidemiologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Minnesota/epidemiologia , Medição de Risco , Fatores de Risco , Análise de Sobrevida , Taxa de Sobrevida
8.
J Am Heart Assoc ; 10(4): e018090, 2021 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-33522246

RESUMO

Background When implantable cardioverter defibrillator (ICD) battery is depleted most patients undergo generator replacement (GR) even in the absence of persistent ICD indication. The aim of this study was to assess the incidence of ventricular arrhythmias and the overall prognosis of patients with and without persistent ICD indication undergoing GR. Predictors of 1-year mortality were also analyzed. Methods and Results Patients with structural heart disease implanted with primary prevention ICD undergoing GR were included. Patients were stratified based on the presence/absence of persistent ICD indication (left ventricular ejection fraction ≤35% at the time of GR and/or history of appropriate ICD therapies during the first generator's life). The study included 371 patients (82% male, 40% with ischemic heart disease). One third of patients (n=121) no longer met ICD indication at the time of GR. During a median follow-up of 34 months after GR patients without persistent ICD indication showed a significantly lower incidence of appropriate ICD shocks (1.9% versus 16.2%, P<0.001) and ICD therapies. 1-year mortality was also significantly lower in patients without persistent ICD indication (1% versus 8.3%, P=0.009). At multivariable analysis permanent atrial fibrillation, chronic advanced renal impairment, age >80, and persistent ICD indication were found to be significant predictors of 1-year mortality. Conclusions Patients without persistent ICD indication at the time of GR show a low incidence of appropriate ICD therapies after GR. Persistent ICD indication, atrial fibrillation, advanced chronic renal disease, and age >80 are significant predictors of 1-year mortality. Our findings enlighten the need of performing a comprehensive clinical reevaluation of ICD patients at the time of GR.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo/métodos , Taquicardia Ventricular/epidemiologia , Idoso , Feminino , Seguimentos , Humanos , Incidência , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Taquicardia Ventricular/terapia , Fatores de Tempo
9.
J Interv Card Electrophysiol ; 58(1): 95-101, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31902085

RESUMO

BACKGROUND: Novel implantable defibrillators (ICDs) allow first (S1) and third (S3) heart sounds to be measured by means of an embedded accelerometer. ICD-measured S1 and S3 have been shown to significantly correlate with hemodynamic changes in acute animal models. The HeartLogic algorithm (Boston Scientific) measures and combines multiple parameters, including S3 and S1, into a single index to predict impending heart failure decompensation. We evaluated the echocardiographic correlates of ICD-measured S1 and S3 in patients with ICD and cardiac resynchronization therapy ICD. METHODS: The HeartLogic feature was activated in 104 patients. During in-office visits, patients underwent echocardiographic evaluation, and parameters of systolic and diastolic function were correlated with S3 and S1 amplitude measured on the same day as the visit. RESULTS: S3 amplitude inversely correlated with deceleration time of the E-wave (r = -0.32; 95% CI -0.46 - -0.17; P < 0.001), and S1 amplitude significantly correlated with left ventricular ejection fraction (r = 0.17; 95% CI 0.03-0.30; P = 0.021). S3 > 0.9 mG detected a restrictive filling pattern with 85% (95% CI 72%-93%) sensitivity and 82% (95% CI 75%-88%) specificity, while S1 < 1.5 mG detected ejection fraction < 35% with 28% (95% CI 19%-40%) sensitivity and 88% (95% CI 80%-93%) specificity. CONCLUSION: ICD-measured heart sound parameters are significantly correlated with echocardiographic indexes of systolic and diastolic function. This confirms their utility for remote patient monitoring when used as single sensors and their potential relevance when considered in combination with other physiological ICD sensors that evaluate various aspects of heart failure physiology.


Assuntos
Insuficiência Cardíaca , Ruídos Cardíacos , Animais , Ecocardiografia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Volume Sistólico , Sístole , Função Ventricular Esquerda
10.
Clin Cardiol ; 43(7): 691-697, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32304098

RESUMO

BACKGROUND: The HeartLogic algorithm measures data from multiple implantable cardioverter-defibrillator-based sensors and combines them into a single index. The associated alert has proved to be a sensitive and timely predictor of impending heart failure (HF) decompensation. HYPOTHESIS: We describe a multicenter experience of remote HF management by means of HeartLogic and appraise the value of an alert-based follow-up strategy. METHODS: The alert was activated in 104 patients. All patients were followed up according to a standardized protocol that included remote data reviews and patient phone contacts every month and at the time of alerts. In-office examinations were performed every 6 months or when deemed necessary. RESULTS: During a median follow-up of 13 (10-16) months, the overall number of HF hospitalizations was 16 (rate 0.15 hospitalizations/patient-year) and 100 alerts were reported in 53 patients. Sixty alerts were judged clinically meaningful, and were associated with multiple HF-related conditions. In 48 of the 60 alerts, the clinician was not previously aware of the condition. Of these 48 alerts, 43 triggered clinical actions. The rate of alerts judged nonclinically meaningful was 0.37/patient-year, and the rate of hospitalizations not associated with an alert was 0.05/patient-year. Centers performed remote follow-up assessments of 1113 scheduled monthly transmissions (10.3/patient-year) and 100 alerts (0.93/patient-year). Monthly remote data review allowed to detect 11 (1%) HF events requiring clinical actions (vs 43% actionable alerts, P < .001). CONCLUSIONS: HeartLogic allowed relevant HF-related clinical conditions to be identified remotely and enabled effective clinical actions to be taken; the rates of unexplained alerts and undetected HF events were low. An alert-based management strategy seemed more efficient than a scheduled monthly remote follow-up scheme.


Assuntos
Algoritmos , Dispositivos de Terapia de Ressincronização Cardíaca/estatística & dados numéricos , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/diagnóstico , Frequência Cardíaca/fisiologia , Monitorização Fisiológica/instrumentação , Idoso , Gerenciamento Clínico , Feminino , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Estudos Prospectivos
11.
Europace ; 11(2): 260-2, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19056746

RESUMO

Intermittent retrograde conduction over an accessory pathway (AP) is quite an uncommon phenomenon. We describe the case of a 60-year-old woman with recurrent episodes of palpitations. Atrioventricular re-entry tachycardia was diagnosed at electrophysiological study. Interestingly, retrograde conduction over the AP was detectable only when ventricular pacing was performed at fast rate. Supernormal retrograde conduction over the AP was considered the most likely explanation of this unusual finding.


Assuntos
Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Ventrículos do Coração/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Nó Atrioventricular/fisiopatologia , Eletrocardiografia , Feminino , Humanos , Pessoa de Meia-Idade , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico
12.
Pacing Clin Electrophysiol ; 32(8): 1040-9, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19659624

RESUMO

AIMS: Right ventricular (RV) dysfunction is a marker of poor prognosis in heart failure (HF) patients. It is still unclear whether RV function might influence response to cardiac resynchronization therapy (CRT). METHODS: Forty-four consecutive patients with HF, large QRS, and either intraventricular or interventricular dyssynchrony underwent echocardiographic evaluation before, 1 month after, and 6 months after CRT. Response to CRT was considered in case of significant LV reverse remodeling, defined as the occurrence of LV end-systolic volume (LVESV) reduction > or =15% at 6 months. RESULTS: All echocardiographic indexes of baseline RV function and dimensions were significantly more impaired in nonresponders versus responders to CRT: tricuspid annular plane systolic excursion (TAPSE 15 +/- 4 mm vs 20 +/- 5 mm, P = 0.001), RV systolic pulmonary artery pressure (RVSP 39 +/- 14 mmHg vs 27 +/- 8 mmHg, P = 0.02), RV end-diastolic area (RVEDA 23 +/- 6 cm(2) vs 16 +/- 3 cm(2) P < 0.001), RV end-systolic area (RVESA 16 +/- 6 cm(2) vs 8 +/- 2 cm(2), P = 0.001), and RV fractional area change (30 +/- 12% vs 48 +/- 8%, P < 0.001). All the indexes of RV function significantly correlated with the percentage of LVESV reduction after CRT. Severe RV dysfunction was defined as TAPSE < or =14 mm and the population was stratified into two groups based on baseline TAPSE < or = or > 14 mm. As compared to those with high TAPSE (n = 30), patients with low TAPSE (n = 14) were less likely to show LV reverse remodeling after CRT (76% vs 14%, P < 0.001). CONCLUSIONS: Our study suggests that RV function significantly affects response to CRT. Poor LV reverse remodeling occurs after CRT in patients with HF having severe RV dysfunction at baseline.


Assuntos
Estimulação Cardíaca Artificial/métodos , Ecocardiografia/métodos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/prevenção & controle , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/prevenção & controle , Feminino , Insuficiência Cardíaca/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento , Disfunção Ventricular Direita/complicações
13.
Int J Cardiol ; 283: 122-127, 2019 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-30638746

RESUMO

BACKGROUND: Implantable cardioverter-defibrillator (ICD) is an effective therapy to reduce mortality in heart failure. When the ICD generator approaches the end of life, most of the patients undergo an elective generator replacement (GR) even if they no longer meet implantation criteria. Whether arrhythmic risk should be re-assessed at the time of GR is still an open question. The aim of our study was to assess, via a meta-analysis, the occurrence of appropriate ICD therapies after GR in patients stratified based on the presence/absence of ICD indication at the time of GR. METHODS: Via a systematic literature search for primary prevention studies (January 2000-Sectember 2018), 2976 studies were analyzed. 6 studies were lastly included. Patients were categorized into two groups: "with ICD indication" in case of LVEF≤35% at the time of GR and/or appropriate therapies during the first ICD life; "without ICD indication" in case of a LVEF>35% and no previous ICD therapies. Incidences of appropriate ICD therapies were computed as number of events per 100 person-year. RESULT: We included 478 pts. (65%) with and 255 patients (35%) without persistent ICD indication. The incidence of appropriate therapies was 12.3/100-person-year in patients with vs. 3.4 in patients without persistent ICD indication (2.98 fold higher risk of ICD therapies). CONCLUSION: Patients who no longer meet ICD implantation criteria at the time of GR present a significantly lower risk of appropriate ICD therapies after GR. The results of this study underline the importance of an arrhythmic risk re-stratification at the time of GR.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Insuficiência Cardíaca/terapia , Prevenção Primária/métodos , Remoção de Dispositivo , Humanos
14.
ESC Heart Fail ; 6(2): 308-318, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30632306

RESUMO

AIMS: In the Multisensor Chronic Evaluation in Ambulatory Heart Failure Patients study, a novel algorithm for heart failure (HF) monitoring was implemented. The HeartLogic (Boston Scientific) index combines data from multiple implantable cardioverter defibrillator (ICD)-based sensors and has proved to be a sensitive and timely predictor of impending HF decompensation. The remote monitoring of HF patients by means of HeartLogic has never been described in clinical practice. We report post-implantation data collected from sensors, the combined index, and their association with clinical events during follow-up in a group of patients who received a HeartLogic-enabled device in clinical practice. METHODS AND RESULTS: Patients with ICD and cardiac resynchronization therapy ICD were remotely monitored. In December 2017, the HeartLogic feature was activated on the remote monitoring platform, and multiple ICD-based sensor data collected since device implantation were made available: HeartLogic index, heart rate, heart sounds, thoracic impedance, respiration, and activity. Their association with clinical events was retrospectively analysed. Data from 58 patients were analysed. During a mean follow-up of 5 ± 3 months, the HeartLogic index crossed the threshold value (set by default to 16) 24 times (over 24 person-years, 0.99 alerts/patient-year) in 16 patients. HeartLogic alerts preceded five HF hospitalizations and five unplanned in-office visits for HF. Symptoms or signs of HF were also reported at the time of five scheduled visits. The median early warning time and the time spent in alert were longer in the case of hospitalizations than in the case of minor events of clinical deterioration of HF. HeartLogic contributing sensors detected changes in heart sound amplitude (increased third sound and decreased first sound) in all cases of alerts. Patients with HeartLogic alerts during the observation period had higher New York Heart Association class (P = 0.025) and lower ejection fraction (P = 0.016) at the time of activation. CONCLUSIONS: Our retrospective analysis indicates that the HeartLogic algorithm might be useful to detect gradual worsening of HF and to stratify risk of HF decompensation.


Assuntos
Algoritmos , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca/fisiologia , Monitorização Fisiológica/instrumentação , Transdutores , Idoso , Desenho de Equipamento , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Hospitalização/tendências , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Tempo
15.
Pacing Clin Electrophysiol ; 31(4): 503-5, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18373772

RESUMO

The optimal left ventricular pacing location for cardiac resynchronization therapy should be individualized according to the site of maximal mechanical delay. However, the presence of vein stenosis or kinking in coronary sinus (CS) anatomy could hamper lead implantation in the target vessel. We describe the case of a patient with dilated cardiomyopathy and a dual-chamber pacemaker referred for upgrading to a biventricular device owing to New York Heart Association III heart failure symptoms. Tissue Doppler analysis before implantation showed that the area of maximum activation delay was located in the posterolateral region of the left ventricle. Insertion of the lead into a posterolateral vein of the CS by means of the standard over-the-wire approach was unsuccessful due to the presence of a stenosis at the ostium of the vein. Lead placement in an anterior vein of the CS was unsatisfactory owing to a poor local delay from QRS onset. After balloon vein angioplasty, the pacing lead passed through the stenotic tract at the ostium of the target vein and was successfully positioned in the posterolateral region. Three months after pacemaker implantation, echocardiography showed an important reduction in the indexes of both inter- and intraventricular asynchrony and a significant left ventricular reverse remodeling.


Assuntos
Bloqueio Atrioventricular/prevenção & controle , Seio Coronário/cirurgia , Eletrodos Implantados , Marca-Passo Artificial , Implantação de Prótese/métodos , Feminino , Humanos , Pessoa de Meia-Idade
16.
Europace ; 9(12): 1151-7, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17947251

RESUMO

AIMS: The present study assessed the role of programmed ventricular stimulation (PVS) in risk stratification of patients with ischaemic cardiomyopathy (ICM), candidates for implantable cardioverter-defibrillator (ICD). METHODS AND RESULTS: Consecutive patients with ICM and LVEF < or = 40% (n = 106, age 61 +/- 7 years, LVEF 27 +/- 7%) underwent PVS. This was considered positive in case of inducibility of monomorphic ventricular tachycardia (VT) with < or =3 extrastimuli; polymorphic VT, ventricular fibrillation (VF), and fast monomorphic VT (CL < or = 230 ms) with < or =2 extrastimuli. Primary end-point was the combination of arrhythmic death and VF requiring ICD shock. Forty-nine patients (46%) were inducible at PVS; 74 (70%) were implanted with ICD. During a 24-month follow-up, the primary end-point occurred more frequently in positive PVS patients among the overall population, among patients with LVEF < or = 30% (n = 80) and among patients with an ICD. The negative predictive value of PVS was 96% in each group. In the overall population, both PVS (HR 7.32, 95% CI 1.6-32) and LVEF (HR 4.59, 95% CI 1.6-13) predicted the primary end-point. CONCLUSION: PVS may still have a role in predicting the arrhythmic risk in patients with ICM. A negative PVS identifies a subgroup with a very low risk of arrhythmic events even in patients with LVEF < or = 30%.


Assuntos
Desfibriladores Implantáveis , Terapia por Estimulação Elétrica/métodos , Ventrículos do Coração/fisiopatologia , Isquemia Miocárdica/fisiopatologia , Seleção de Pacientes , Idoso , Determinação de Ponto Final , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações , Isquemia Miocárdica/terapia , Valor Preditivo dos Testes , Fatores de Risco , Volume Sistólico/fisiologia , Análise de Sobrevida , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/terapia , Disfunção Ventricular Esquerda/fisiopatologia , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/fisiopatologia , Fibrilação Ventricular/terapia
17.
Int J Cardiol ; 221: 820-6, 2016 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-27434351

RESUMO

INTRODUCTION: Device related distress negatively affects the quality of life of cardiac device recipients mostly of women. A submammary approach has been proposed to reduce the physical impact of the implantation. Our aim was to assess the safety of this approach and to evaluate the patients' acceptance of the device. METHODS: We enrolled 42 patients who underwent a submammary device. The primary endpoint was the need for implant revision that was assessed in the study group compared with the overall control group of 72 standard cardiac device recipients (29 females and 43 males)and with the female group (29 females of controls). In the female population (42 women of the submammary group and 29 of controls) patients' acceptance was calculated with the Florida Patient Acceptance Survey (FPAS). RESULTS: The rate of implant revision was similar in the two groups and the revision-free survival was comparable with a median follow-up of about six years (Log rank test p=0.949). Similar results were found when considering only the female population. Patients' acceptance was greater in the submammary group [total FPAS 85 (95%CI 83-86) vs 74.5 (95%CI 70.2-77.3) p<0,001] and a strongly significant superiority of the submammary group was found regarding body image concerns [10 (95%CI 10-10) vs 8 (95%CI 8-8) p<0.001) and device related distress [23 (95%CI 22-23) vs 1 (95%CI 1-1) p<0.001]. CONCLUSIONS: Submammary device implantation is safe and more accepted than standard approach. Our results should encourage cardiologists to suggest this approach to their patients for a better acceptance of the therapy.


Assuntos
Desfibriladores Implantáveis/tendências , Glândulas Mamárias Humanas , Aceitação pelo Paciente de Cuidados de Saúde , Satisfação do Paciente , Adulto , Desfibriladores Implantáveis/normas , Feminino , Seguimentos , Humanos , Masculino , Glândulas Mamárias Humanas/diagnóstico por imagem , Pessoa de Meia-Idade , Aceitação pelo Paciente de Cuidados de Saúde/psicologia , Qualidade de Vida/psicologia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
18.
J Cardiovasc Med (Hagerstown) ; 17(4): 291-8, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25222077

RESUMO

AIMS: Cardiac resynchronization therapy (CRT) is a well established therapy in heart failure patients who are on optimal medical therapy and have reduced left ventricular ejection fraction (LVEF) and wide QRS complexes. Although women and patients with nonischemic cardiomyopathy are under-represented in CRT trials and registries, there is evidence that these two groups of patients can benefit more from CRT. The aim of our analysis was to investigate the impact of female sex on mortality in a population that included a high percentage of patients (61%) with nonischemic cardiomyopathy. METHODS: We analyzed data on 507 consecutive patients (20% women) who received CRT at two Italian Heart Transplant centers and were followed up for a maximum of 48 months. RESULTS: After multivariate adjustment, women showed a trend toward better survival with regard to all-cause mortality [hazard ratio (HR) 0.32, confidence interval (CI) 0.10-1.04; P = 0.059]. However, this benefit was limited to nonischemic patients with regard to all-cause mortality (HR 0.20, CI 0.05-0.87, P = 0.032) and cardiovascular mortality (HR 0.14, CI 0.02-1.05, P = 0.056). CONCLUSION: Female CRT recipients, at mid-term, have a favorable prognosis than male patients and this benefit appears to be more evident in nonischemic patients. Thus, we strongly believe that the apparent under-utilization of CRT in females is an anomaly that should be corrected.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Cardiomiopatias/terapia , Remodelação Ventricular/fisiologia , Idoso , Cardiomiopatias/diagnóstico , Cardiomiopatias/mortalidade , Cardiomiopatias/fisiopatologia , Desfibriladores Implantáveis , Feminino , Seguimentos , Humanos , Itália/epidemiologia , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Prognóstico , Fatores Sexuais , Volume Sistólico/fisiologia , Resultado do Tratamento
19.
Ital Heart J ; 6(1): 80-4, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15773279

RESUMO

It has been suggested that a reentrant circuit confined to the posterior extensions of the atrioventricular node underlies both fast-slow and slow-slow types of atrioventricular nodal reentrant tachycardia (AVNRT). According to this hypothesis the fast-slow reentrant circuit would be formed by two slow pathways, located in the rightward and leftward posterior extension of the atrioventricular node. Thus, the fast pathway would act as a bystander with respect to the reentrant circuit. We describe the case of a 40-year-old woman with several episodes of palpitations unresponsive to antiarrhythmic drugs. The ECG during symptoms showed a narrow QRS tachycardia with a long ventriculo-atrial interval and a negative P wave in the inferior leads. Electrophysiological study showed the inducibility of a slow-slow AVNRT which rapidly shifted to a fast-slow AVNRT without any change in the duration of the tachycardia cycle. Our observation is in agreement with the hypothesis that the fast-slow reentrant circuit consists of two slow pathways with the fast pathway acting as a bystander.


Assuntos
Nó Atrioventricular/fisiopatologia , Frequência Cardíaca/fisiologia , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Adulto , Fascículo Atrioventricular/fisiopatologia , Fascículo Atrioventricular/cirurgia , Ablação por Cateter , Eletrocardiografia , Feminino , Humanos , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA