1.
Med Phys ; 33(1): 96-105, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16485414

RESUMO

High precision techniques in radiation therapy, such as intensity modulated radiation therapy, offer the potential for improved target coverage and increased normal tissue sparing compared with conformal radiotherapy. The complex fluence maps used in many of these techniques, however, often lead to more challenging quality assurance with dose verification being labor-intensive and time consuming. A prototype dose verification system has been developed using a tissue equivalent plastic scintillator that provides easy-to-acquire, rapid, digital dose measurements in a plane perpendicular to the beam. The system consists of a water-filled Lucite phantom with a scintillator screen built into the top surface. The phantom contains a silver coated plastic mirror to reflect scintillation light towards a viewing window where it is captured using a charge coupled device camera and a personal computer. Optical photon spread is removed using a microlouvre optical collimator and by deconvolving a glare kernel from the raw images. A characterization of the system was performed that included measurements of linear output response, dose rate dependence, spatial linearity, effective pixel size, signal uniformity and both short- and long-term reproducibility. The average pixel intensity for static, regular shaped fields between 3 cm X 3 cm and 12 cm x 12 cm imaged with the system was found to be linear in the dose delivered with linear regression analysis yielding a correlation coefficient r2 > 0.99. Effective pixel size was determined to be 0.53 mm/pixel. The system was found to have a signal uniformity of 5.6% and a long-term reproducibility/stability of 1.7% over a 6 month period. The system's ability to verify a dynamic treatment field was evaluated using 60 degrees dynamic wedged fields and comparing the results to two-dimensional film dosimetry. Results indicate agreement with two-dimensional film dosimetry distributions within 8% inside the field edges. With further development, this system promises to provide a fast, directly digital, and tissue equivalent alternative to current dose verification systems.


Assuntos
Materiais Biomiméticos/efeitos da radiação , Plásticos/efeitos da radiação , Radiometria/instrumentação , Radioterapia Conformacional/instrumentação , Contagem de Cintilação/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Radiometria/métodos , Dosagem Radioterapêutica , Radioterapia Conformacional/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Int J Radiat Oncol Biol Phys ; 49(3): 869-84, 2001 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-11172971

RESUMO

PURPOSE: To use portal imaging to measure daily on-line setup error and off-line prostatic motion in patients treated with conformal radiotherapy to determine an optimum planning target volume (PTV) margin incorporating both setup error and organ motion. RESULTS: A total of 2549 portal images from 33 patients were acquired over the course of the study. Of these patients, 23 were analyzed for setup errors while the remaining 10 were analyzed for prostatic motion. Setup errors were characterized by standard deviations of 1.8 mm in the anterior-posterior (AP) direction and 1.4 mm in the superior-inferior (SI) direction. Displacements due to prostatic motion, with standard deviations of 5.8 mm AP and 3.3 mm SI, were found to be more significant than setup errors. CONCLUSIONS: Taking into account both setup errors and target organ motion, optimum PTV margins to ensure 95% coverage are 10.0 mm AP and 5.9 mm SI. The portal imaging protocol established in this study allows radiation therapists to accept or adjust a treatment setup based upon daily on-line image matching results. The successful localization of radiopaque fiducial markers on a significant number of portal images acquired in the study gives hope that more accurate on-line targeting verification may soon be possible through the visualization of the prostate itself as opposed to the surrounding bony structures of the pelvis.


Assuntos
Carcinoma/radioterapia , Movimento , Neoplasias da Próstata/radioterapia , Radioterapia Conformacional/métodos , Carcinoma/diagnóstico por imagem , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Radiografia , Dosagem Radioterapêutica , Reprodutibilidade dos Testes