Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Ann Vasc Surg ; 98: 317-324, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37355020

RESUMO

BACKGROUND: Carotid plaque volume (CPV) can be measured by 3D ultrasound and may be a better predictor of stroke than stenosis, but analysis time limits clinical utility. This study tested the accuracy, reproducibility, and time saved of using an artificial intelligence (AI) derived semiautomatic software to measure CPV ("auto-CPV"). METHODS: Three-dimensional (3D) ultrasound images for 121 individuals were analyzed by 2 blinded operators to measure auto-CPV. Corresponding endarterectomy specimen volumes were calculated by the validated saline suspension technique. Inter-rater and intrarater agreement plus accuracy compared with the volume of the endarterectomized plaque were calculated. Measurement times were compared with previous manual CPV measurement. RESULTS: The mean difference between auto-CPV and surgical volume was small at (±s.d.) [95% confidence interval [CI]] 0.06 (0.24) [-0.41 to 0.54] cm3. The intraclass correlation (ICC) was strong at 0.91; 95% CI 0.86-0.94. Interobserver and intraobserver error was low with mean difference (±s.d.) [95%CI] 0.01 (0.26) [-0.5 to 0.5] cm3 and 0.03 (0.19) [-0.35 to 0.40] cm3 respectively. Both showed excellent ICC with narrow confidence intervals, ICC = 0.90; 95% CI (0.85-0.94) and ICC = 0.95; 95% CI (0.92-0.96). Auto-CPV measurement took 43% the time of manual planimetry; median (IQR) 05:39 (01:58) minutes compared to 13:05 (04:15) minutes, Wilcoxon rank-sum test, P < 0.01. CONCLUSIONS: Auto-CPV assessment is accurate, reproducible, and significantly faster than manual planimetry. Improved feasibility means that the utility of CPV can be assessed in large population studies to stratify risk in asymptomatic carotid disease or assess response to medical treatment.


Assuntos
Inteligência Artificial , Placa Aterosclerótica , Humanos , Reprodutibilidade dos Testes , Resultado do Tratamento , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/cirurgia , Ultrassonografia , Imageamento Tridimensional , Variações Dependentes do Observador
2.
Eur J Vasc Endovasc Surg ; 61(3): 440-446, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33229220

RESUMO

OBJECTIVE: Clear imaging of below knee and foot arteries is essential to plan distal reconstructions. Contrast enhanced tomographic 3D ultrasound (CEtUS) is novel and entirely safe with no exposure to ionising radiation or nephrotoxic contrast. In the present study, inter- and intra-observer agreement of CEtUS was calculated, and compared with below knee angiography. METHODS: In the same week as computed tomography, magnetic resonance or catheter angiography, CEtUS was performed using intravenous 1.2 mL bolus injections of Sonovue with a maximum of 5 mL administered per patient. CEtUS was reported by a vascular scientist blinded to the angiograms reported by a consultant radiologist. Images were compared using a modified Society of Vascular Surgery (SVS) runoff score. RESULTS: Of the 181 patients recruited with peripheral arterial disease, 20 were excluded from analysis as they withdrew consent, could not be cannulated, or their images were non-diagnostic. In the remaining 161 patients, there were 175 comparative patient images split into two groups: 81 had calf imaging and 94 had pedal imaging representing 405 and 198 imaged arteries, respectively. Weighted quadratic kappa/ICC values for intra- and inter-observer agreement were excellent (κ/ICC = 0.83 to 0.95) and had narrow confidence intervals in both groups. When comparing angiography and CEtUS, weighted quadratic κ/ICC agreement was moderate with acceptable confidence intervals in both groups (Calf κ/ICC = 0.54; Pedal κ/ICC = 0.53). Agreement decreased from popliteal to pedal vessels as diameter decreased. Agreement between CEtUS and digital subtraction angiography was best, and computed tomography angiography the weakest. CONCLUSION: CEtUS is a novel imaging modality with strong observer agreement that achieves clear peripheral and foot images without ionising radiation exposure or nephrotoxic X-ray contrast media. CEtUS enhances visualisation of runoff vessels, which may play a role in planning of limb salvage or targeted assessment.


Assuntos
Pé/irrigação sanguínea , Pé/diagnóstico por imagem , Perna (Membro)/irrigação sanguínea , Perna (Membro)/diagnóstico por imagem , Doença Arterial Periférica/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Meios de Contraste , Feminino , Humanos , Imageamento Tridimensional , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X , Ultrassonografia
4.
J Vasc Surg ; 64(4): 1141-1150.e1, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27473776

RESUMO

BACKGROUND: Popliteal artery aneurysm is an uncommon vascular disease but one that can cause significant morbidity, the most severe being limb loss reported in 20% to 59% of cases. Two approaches to repair are described in the literature, the posterior and the medial; however, the "gold standard" method of repair remains controversial. METHODS: A systematic review of electronic information sources was undertaken to identify papers comparing outcomes of posterior repair vs medial repair. The methodologic quality of the papers was assessed using the Newcastle-Ottawa Scale. Fixed-effect or random-effects models were applied to synthesize data. RESULTS: The search yielded seven articles eligible for inclusion. The total population comprised 1427 patients; 338 had posterior repair and 1089 had medial repair. There was no difference in the two groups in terms of postoperative nerve damage (odds ratio [OR], 1.01; 95% confidence interval [CI], 0.24-4.2) and 30-day postoperative complications (OR, 0.87; 95% CI, 0.43-1.77). Limb loss at 30 days occurred more frequently in the medial approach group, but the difference was not statistically significant (risk difference [RD], 0.02; 95% CI, -0.04 to 0.00). Thirty-day primary patency was not statistically different between groups (RD, -0.01; 95% CI, -0.04 to 0.02), but the 30-day secondary patency suggested superiority of the posterior approach (RD, 0.05; 95% CI, 0.02-0.07). Long-term primary and secondary patency both favored the posterior approach (OR, 1.61 [95% CI, 1.06-2.43] and OR, 1.73 [95% CI, 0.91-3.30], respectively). Aneurysm exclusion was also superior with the posterior approach (OR, 4.20; 95% CI, 1.40-12.60). The rate of reoperation favored the posterior approach (OR, 0.26; 95% CI, 0.09-0.72). Long-term risk of limb loss favored posterior repair, but no statistically significant difference was found (OR, 0.32; 95% CI, 0.43-1.77). CONCLUSIONS: High-level comparative data comparing posterior and medial repair for popliteal artery aneurysms are not available. Within the parameters of this review, however, superiority of the posterior approach for primary and secondary patency, aneurysm exclusion, and need for reoperation was noted. High-level evidence from randomized clinical trials is required to define the relative benefits of the posterior approach over the medial approach in selected patients.


Assuntos
Aneurisma/cirurgia , Implante de Prótese Vascular/métodos , Artéria Poplítea/cirurgia , Idoso , Idoso de 80 Anos ou mais , Amputação Cirúrgica , Aneurisma/diagnóstico por imagem , Aneurisma/mortalidade , Aneurisma/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Distribuição de Qui-Quadrado , Feminino , Humanos , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Razão de Chances , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Reoperação , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
5.
Vasc Endovascular Surg ; 58(4): 361-366, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37956988

RESUMO

OBJECTIVE: A novel carotid quick scan (CQS) protocol was developed to rapidly screen for carotid atherosclerosis greater than 50% stenosis in a vascular outpatient setting. This study assessed accuracy and time saved. MATERIAL & METHODS: The CQS was developed by consensus agreement between vascular surgeons and accredited clinical vascular scientists through a modified Delphi technique. The protocol comprised a rapid B-mode then colour flow transverse sweep of the common and internal carotid arteries, with internal carotid artery velocity assessment. One hundred outpatients attending with peripheral artery disease or abdominal aortic aneurysm were recruited. CQS sensitivity, specificity and accuracy was assessed against a conventional full carotid duplex study, performed to UK and ESVS guidelines. RESULTS: Twenty four percent of patients (n = 100) had >50% carotid NASCET stenosis. CQS achieved an excellent accuracy of 96.5% in detecting >50% stenosis when compared to full duplex; Cohen's ƙ = .88, (95%CI .79-.97; P < .001), sensitivity 91.4%, specificity 97.6%, positive predictive value (PPV) 88.9% and negative predictive value (NPV) 98.2%. Median (IQR) time to complete the CQS was 13 sec (±12) per side, compared to 151 sec (±78) per side for the full carotid duplex. In the presence of >50% carotid disease, median CQS time was 25 sec (±31) per side compared to 214 (±104) by full scan. CONCLUSION: CQS as a carotid screening tool is rapid, accurate and acceptable to the population and workforce. It would be simple to roll out in all vascular laboratories to reduce the time and cost burden of excluding significant carotid disease in any group.


Assuntos
Estenose das Carótidas , Ultrassonografia Doppler Dupla , Humanos , Sensibilidade e Especificidade , Estudos Prospectivos , Constrição Patológica , Resultado do Tratamento , Artéria Carótida Interna/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/cirurgia , Velocidade do Fluxo Sanguíneo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA