Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 213
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 390(2): 107-117, 2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-37952132

RESUMO

BACKGROUND: Subclinical atrial fibrillation is short-lasting and asymptomatic and can usually be detected only by long-term continuous monitoring with pacemakers or defibrillators. Subclinical atrial fibrillation is associated with an increased risk of stroke by a factor of 2.5; however, treatment with oral anticoagulation is of uncertain benefit. METHODS: We conducted a trial involving patients with subclinical atrial fibrillation lasting 6 minutes to 24 hours. Patients were randomly assigned in a double-blind, double-dummy design to receive apixaban at a dose of 5 mg twice daily (2.5 mg twice daily when indicated) or aspirin at a dose of 81 mg daily. The trial medication was discontinued and anticoagulation started if subclinical atrial fibrillation lasting more than 24 hours or clinical atrial fibrillation developed. The primary efficacy outcome, stroke or systemic embolism, was assessed in the intention-to-treat population (all the patients who had undergone randomization); the primary safety outcome, major bleeding, was assessed in the on-treatment population (all the patients who had undergone randomization and received at least one dose of the assigned trial drug, with follow-up censored 5 days after permanent discontinuation of trial medication for any reason). RESULTS: We included 4012 patients with a mean (±SD) age of 76.8±7.6 years and a mean CHA2DS2-VASc score of 3.9±1.1 (scores range from 0 to 9, with higher scores indicating a higher risk of stroke); 36.1% of the patients were women. After a mean follow-up of 3.5±1.8 years, stroke or systemic embolism occurred in 55 patients in the apixaban group (0.78% per patient-year) and in 86 patients in the aspirin group (1.24% per patient-year) (hazard ratio, 0.63; 95% confidence interval [CI], 0.45 to 0.88; P = 0.007). In the on-treatment population, the rate of major bleeding was 1.71% per patient-year in the apixaban group and 0.94% per patient-year in the aspirin group (hazard ratio, 1.80; 95% CI, 1.26 to 2.57; P = 0.001). Fatal bleeding occurred in 5 patients in the apixaban group and 8 patients in the aspirin group. CONCLUSIONS: Among patients with subclinical atrial fibrillation, apixaban resulted in a lower risk of stroke or systemic embolism than aspirin but a higher risk of major bleeding. (Funded by the Canadian Institutes of Health Research and others; ARTESIA ClinicalTrials.gov number, NCT01938248.).


Assuntos
Anticoagulantes , Aspirina , Fibrilação Atrial , Embolia , Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Anticoagulantes/efeitos adversos , Anticoagulantes/uso terapêutico , Aspirina/efeitos adversos , Aspirina/uso terapêutico , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Canadá , Embolia/etiologia , Embolia/prevenção & controle , Hemorragia/induzido quimicamente , Piridonas/efeitos adversos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento , Inibidores do Fator Xa/efeitos adversos , Inibidores do Fator Xa/uso terapêutico , Método Duplo-Cego
2.
Lancet ; 402(10408): 1147-1157, 2023 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-37634520

RESUMO

BACKGROUND: Continuous automatic optimisation of cardiac resynchronisation therapy (CRT), stimulating only the left ventricle to fuse with intrinsic right bundle conduction (synchronised left ventricular stimulation), might offer better outcomes than conventional CRT in patients with heart failure, left bundle branch block, and normal atrioventricular conduction. This study aimed to compare clinical outcomes of adaptive CRT versus conventional CRT in patients with heart failure with intact atrioventricular conduction and left bundle branch block. METHODS: This global, prospective, randomised controlled trial was done in 227 hospitals in 27 countries across Asia, Australia, Europe, and North America. Eligible patients were aged 18 years or older with class 2-4 heart failure, an ejection fraction of 35% or less, left bundle branch block with QRS duration of 140 ms or more (male patients) or 130 ms or more (female patients), and a baseline PR interval 200 ms or less. Patients were randomly assigned (1:1) via block permutation to adaptive CRT (an algorithm providing synchronised left ventricular stimulation) or conventional biventricular CRT using a device programmer. All patients received device programming but were masked until procedures were completed. Site staff were not masked to group assignment. The primary outcome was a composite of all-cause death or intervention for heart failure decompensation and was assessed in the intention-to-treat population. Safety events were collected and reported in the intention-to-treat population. This study is registered with ClinicalTrials.gov, NCT02205359, and is closed to accrual. FINDINGS: Between Aug 5, 2014, and Jan 31, 2019, of 3797 patients enrolled, 3617 (95·3%) were randomly assigned (1810 to adaptive CRT and 1807 to conventional CRT). The futility boundary was crossed at the third interim analysis on June 23, 2022, when the decision was made to stop the trial early. 1568 (43·4%) of 3617 patients were female and 2049 (56·6%) were male. Median follow-up was 59·0 months (IQR 45-72). A primary outcome event occurred in 430 of 1810 patients (Kaplan-Meier occurrence rate 23·5% [95% CI 21·3-25·5] at 60 months) in the adaptive CRT group and in 470 of 1807 patients (25·7% [23·5-27·8] at 60 months) in the conventional CRT group (hazard ratio 0·89, 95% CI 0·78-1·01; p=0·077). System-related adverse events were reported in 452 (25·0%) of 1810 patients in the adaptive CRT group and 440 (24·3%) of 1807 patients in the conventional CRT group. INTERPRETATION: Compared with conventional CRT, adaptive CRT did not significantly reduce the incidence of all-cause death or intervention for heart failure decompensation in the included population of patients with heart failure, left bundle branch block, and intact AV conduction. Death and heart failure decompensation rates were low with both CRT therapies, suggesting a greater response to CRT occurred in this population than in patients in previous trials. FUNDING: Medtronic.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Feminino , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/terapia , Estudos Prospectivos , Resultado do Tratamento , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Volume Sistólico , Eletrocardiografia
3.
Artigo em Inglês | MEDLINE | ID: mdl-38491744

RESUMO

A 40-year-old man, newly diagnosed with cardiac sarcoidosis (CS) presented with symptomatic ventricular tachycardia three days after starting steroid-based immunosuppressive therapy (IT). There was no clear guideline indication for implantable cardioverter-defibrillator (ICD) before the initiation of IT. Shortly after ICD implantation and the initiation of anti-arrhythmic drugs, recurring ventricular arrhythmias required titration of the anti-arrhythmic drug therapy. One-year follow-up assessment showed no significant arrhythmias and complete PET scan FDG uptake suppression. This case, along with recent publications, suggests transient pro-arrhythmic effects of steroids in patients with CS, which are not appropriately addressed in the current guidelines. We believe ICD implantation should be considered in clinically manifest CS before initiating IT, particularly in cases with heterogeneous and/or extensive FDG uptake on PET scans.

4.
Eur Heart J ; 44(10): 822-832, 2023 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-36445158

RESUMO

AIMS: The impact of sexuality in patients with significant tricuspid regurgitation (TR) undergoing transcatheter tricuspid valve intervention (TTVI) is unknown. The aim of this study was to investigate sex-specific outcomes in patients with significant TR treated with TTVI vs. medical therapy alone. METHODS AND RESULTS: The Transcatheter Tricuspid Valve Therapies (TriValve) registry collected data on patients with significant TR from 24 centres who underwent TTVI from 2016 to 2021. A control cohort was formed by medically managed patients with ≥severe isolated TR diagnosed in 2015-18. The primary endpoint was freedom from all-cause mortality. Secondary endpoints were heart failure (HF) hospitalization, New York Heart Association (NYHA) functional status, and TR severity. One-year outcomes were assessed for the TriValve cohort and compared with the control cohort with the inverse probability of treatment weighting (IPTW). A total of 556 and 2072 patients were included from the TriValve and control groups, respectively. After TTVI, there was no difference between women and men in 1-year freedom from all-cause mortality 80.9% vs. 77.9%, P = 0.56, nor in HF hospitalization (P = 0.36), NYHA Functional Classes III and IV (P = 0.17), and TR severity >2+ at last follow-up (P = 0.42). Multivariable Cox-regression weighted by IPTW showed improved 1-year survival after TTVI compared with medical therapy alone in both women (adjusted hazard ratio 0.45, 95% confidence interval 0.23-0.83, P = 0.01) and men (adjusted hazard ratio 0.42, 95% confidence interval 0.18-0.89, P = 0.03). CONCLUSION: After TTVI in high-risk patients, there were no sex-related differences in terms of survival, HF hospitalization, functional status, and TR reduction up to 1 year. The IPTW analysis shows a survival benefit of TTVI over medical therapy alone in both women and men.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Masculino , Humanos , Feminino , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Sistema de Registros , Insuficiência Cardíaca/complicações
5.
Circulation ; 145(23): 1693-1704, 2022 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-35313733

RESUMO

BACKGROUND: Atrial fibrillation (AF) and heart failure (HF) frequently coexist and can be challenging to treat. Pharmacologically based rhythm control of AF has not proven to be superior to rate control. Ablation-based rhythm control was compared with rate control to evaluate if clinical outcomes in patients with HF and AF could be improved. METHODS: This was a multicenter, open-label trial with blinded outcome evaluation using a central adjudication committee. Patients with high-burden paroxysmal (>4 episodes in 6 months) or persistent (duration <3 years) AF, New York Heart Association class II to III HF, and elevated NT-proBNP (N-terminal pro brain natriuretic peptide) were randomly assigned to ablation-based rhythm control or rate control. The primary outcome was a composite of all-cause mortality and all HF events, with a minimum follow-up of 2 years. Secondary outcomes included left ventricular ejection fraction, 6-minute walk test, and NT-proBNP. Quality of life was measured using the Minnesota Living With Heart Failure Questionnaire and the AF Effect on Quality of Life. The primary analysis was time-to-event using Cox proportional hazards modeling. The trial was stopped early because of a determination of apparent futility by the Data Safety Monitoring Committee. RESULTS: From December 1, 2011, to January 20, 2018, 411 patients were randomly assigned to ablation-based rhythm control (n=214) or rate control (n=197). The primary outcome occurred in 50 (23.4%) patients in the ablation-based rhythm-control group and 64 (32.5%) patients in the rate-control group (hazard ratio, 0.71 [95% CI, 0.49-1.03]; P=0.066). Left ventricular ejection fraction increased in the ablation-based group (10.1±1.2% versus 3.8±1.2%, P=0.017), 6-minute walk distance improved (44.9±9.1 m versus 27.5±9.7 m, P=0.025), and NT-proBNP demonstrated a decrease (mean change -77.1% versus -39.2%, P<0.0001). Minnesota Living With Heart Failure Questionnaire demonstrated greater improvement in the ablation-based rhythm-control group (least-squares mean difference of -5.4 [95% CI, -10.5 to -0.3]; P=0.0036), as did the AF Effect on Quality of Life score (least-squares mean difference of 6.2 [95% CI, 1.7-10.7]; P=0.0005). Serious adverse events were observed in 50% of patients in both treatment groups. CONCLUSIONS: In patients with high-burden AF and HF, there was no statistical difference in all-cause mortality or HF events with ablation-based rhythm control versus rate control; however, there was a nonsignificant trend for improved outcomes with ablation-based rhythm control over rate control. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT01420393.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Humanos , Qualidade de Vida , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
6.
Circulation ; 145(10): 742-753, 2022 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-34913361

RESUMO

BACKGROUND: Regulatory authorities of most industrialized countries recommend 6 months of private driving restriction after implantation of a secondary prevention implantable cardioverter-defibrillator (ICD). These driving restrictions result in significant inconvenience and social implications. This study aimed to assess the incidence rate of appropriate device therapies in contemporary recipients of a secondary prevention ICD. METHODS: This retrospective study at 3 Canadian tertiary care centers enrolled consecutive patients with new secondary prevention ICD implants between 2016 and 2020. RESULTS: For a median of 760 days (324, 1190 days), 721 patients were followed up. The risk of recurrent ventricular arrhythmia was highest during the first 3 months after device insertion (34.4%) and decreased over time (10.6% between 3 and 6 months, 11.7% between 6 and 12 months). The corresponding incidence rate per 100 patient-days was 0.48 (95% CI, 0.35-0.64) at 90 days, 0.28 (95% CI, 0.17-0.45) at 180 days, and 0.21 (95% CI, 0.13-0.33) between 181 and 365 days after ICD insertion (P<0.001). The cumulative incidence of arrhythmic syncope resulting in sudden cardiac incapacitation was 1.8% within the first 90 days and subsequently dropped to 0.4% between 91 and 180 days (P<0.001) after ICD insertion. CONCLUSIONS: The incidence rate of appropriate therapies resulting in sudden cardiac incapacitation in contemporary recipients of a secondary prevention ICD is much lower than previously reported and declines significantly after the first 3 months. Lowering driving restrictions to 3 months after the index cardiac event seems safe, and revision of existing guidelines should be considered in countries still adhering to a 6-month period. Existing restrictions for private driving after implantation of a secondary prevention ICD should be reconsidered.


Assuntos
Desfibriladores Implantáveis , Canadá , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Humanos , Prevenção Primária/métodos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo
7.
Am J Med Genet A ; 191(6): 1508-1517, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36864778

RESUMO

Variants of filamin C (FLNC) have been identified as rare genetic substrate for hypertrophic cardiomyopathy (HCM). Data on the clinical course of FLNC-related HCM are conflicting with some studies suggesting mild phenotypes whereas other studies have reported more severe outcomes. In this study, we present a novel FLNC variant (Ile1937Asn) that was identified in a large family of French-Canadian descent with excellent segregation data. FLNC-Ile1937Asn is a novel missense variant characterized by full penetrance and poor clinical outcomes. End stage heart failure requiring transplantation occurred in 43% and sudden cardiac death in 29% of affected family members. Other particular features of FLNC-Ile1937Asn include an early disease onset (mean age of 19 years) and the development of a marked atrial myopathy (severe biatrial dilatation with remodeling and multiple complex atrial arrhythmias) that was present in all gene carriers. The FLNC-Ile1937Asn variant is a novel, pathogenic mutation resulting in a severe form of HCM with full disease penetrance. The variant is associated with a high proportion of end-stage heart failure, heart transplantation, and disease-related mortality. Close follow-up and appropriate risk stratification of affected individuals at specialized heart centers is recommended.


Assuntos
Fibrilação Atrial , Cardiomiopatia Hipertrófica , Cardiomiopatia Restritiva , Insuficiência Cardíaca , Humanos , Cardiomiopatia Restritiva/genética , Mutação , Filaminas/genética , Canadá , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/genética , Insuficiência Cardíaca/genética
8.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37314195

RESUMO

AIMS: Risk stratification for sudden cardiac death in patients with Brugada syndrome remains a major challenge. Contemporary risk prediction models have only modest predictive value. The aim of this study was to assess the role of micro-RNAs from peripheral blood as candidate biomarkers in Brugada syndrome. METHODS AND RESULTS: In this prospective study, Brugada patients and unaffected control individuals were enrolled for analysis of leucocyte-derived microRNAs (miRNAs) levels. Expression levels of 798 different circulating miRNAs were analysed on the NanoString® nCounter platform. All results were cross-validated by using a quantitative polymerase chain reaction. Micro-RNA expression levels of Brugada patients were compared with clinical data. A total of 21 definite Brugada patients (38% with a history of ventricular arrhythmia or cardiac arrest) and 30 unaffected control individuals were included in the study. Micro-RNA analysis showed a distinct expression profile in Brugada patients with 42 differentially expressed markers (38 up-regulated, 4 down-regulated miRNAs). The symptom status of Brugada patients was associated with a distinct miRNA signature. Micro-RNAs 145-5p and 585-3p were significantly up-regulated in symptomatic Brugada patients (P = 0.04). Incorporating miRNAs 145-5p and 585-3p into a multivariable model demonstrated significantly increased symptom prediction (area under the curve = 0.96; 95% confidence interval: 0.88-1.00). CONCLUSION: Brugada patients display a distinct miRNA expression profile compared with unaffected control individuals. There is also evidence that certain miRNAs (miR-145-5p and miR-585-3p) are associated with the symptom status of Brugada patients. The results suggest the principal utility of leucocyte-derived miRNAs as prognostic biomarkers for Brugada syndrome.


Assuntos
Síndrome de Brugada , MicroRNA Circulante , MicroRNAs , Humanos , MicroRNAs/genética , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Estudos Prospectivos , MicroRNA Circulante/genética , Biomarcadores
9.
Pacing Clin Electrophysiol ; 46(8): 934-938, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36550633

RESUMO

Symptomatic thrombus formation due to a permanent pacemaker (PM) lead is a rare complication. It could be associated with serious outcome and should be suspected in patients who present with unexplained right heart failure, dyspnea, or syncope following dual-chamber PM implantation. A timely decision to perform an echocardiographic examination, followed by medical, thrombolytic, or surgical treatment can be necessary. We describe the case of an 84-year-old man who presented with syncope and hypotension a few days after PM implantation. A transesophageal echocardiography revealed a mobile mass in the right atrium attached to the pacemaker lead. Intravenous heparin allowed a complete resolution of the thrombus.


Assuntos
Marca-Passo Artificial , Trombose , Masculino , Humanos , Idoso de 80 Anos ou mais , Trombose/diagnóstico por imagem , Trombose/etiologia , Marca-Passo Artificial/efeitos adversos , Ecocardiografia , Ecocardiografia Transesofagiana , Síncope
10.
Pacing Clin Electrophysiol ; 46(10): 1269-1277, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37664970

RESUMO

BACKGROUND: In patients with refractory atrial fibrillation (AF), atrioventricular nodal (AVN) ablation and permanent pacemaker implantation is recommended. The Micra Transcatheter Pacing System (Micra) is a single chamber leadless pacemaker (LPM) and thus offers the possibility of AV node (AVN) ablation in the same procedure. Pacing threshold (PT) elevation after radiofrequency (RF) ablation is a potential complication. METHODS: We conducted a single center retrospective cohort study. Patients implanted with a Micra (n = 84) and concomitant or delayed AVN ablation (n = 12) from 2014 to 2022 were included. Two cases of acute Micra PT elevation immediately following RF AVN ablation required device retrieval and implantation of a new Micra. Procedural characteristics and electrophysiological parameters were analyzed, and a computer model was performed to determine factors responsible for acute PT elevations. RESULTS: A total of 84 patients were included. Mean age was 74 ± 10 and 48% were women. Twelve patients (14%) underwent AVN ablation. Two patients had acute PT elevation requiring device retrieval despite no direct contact of the ablation catheter with the Micra. Computer modeling shows that significant dissipated power due to electrical field coupling can occur at the tip or ring electrode if the catheter is not kept at a safe distance (≥35 mm) from the Micra when a maximum power of 100 W is delivered. CONCLUSION: Concurrent AVN ablation and Micra implantation is safe in most patients. To prevent acute PT elevation, keeping a safe distance of ≥35 mm from the tip and ring electrodes of the Micra and using lower power output may prevent this complication.

11.
Pacing Clin Electrophysiol ; 46(7): 639-644, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37196145

RESUMO

INTRODUCTION: Superior vena cava (SVC) tear is the most lethal complication during transvenous lead extraction (TLE) with a mortality rate as high as 50%. Treatment involves aggressive attempts to maintain cardiac output and immediate sternotomy to localize and repair the vascular tear. Occlusion balloons have been developed to provisionally occlude the lacerated SVC and to provide hemodynamic stability allowing time for surgery. In case of mediastinal hematoma without hemodynamic instability, the strategy remains unclear. METHODS AND RESULTS: We describe two cases of SVC tear during TLE. The first case was a 60-year-old man who presented with a right ventricular single-chamber defibrillator lead fracture and innominate vein stenosis. The RV lead was removed using a laser sheath causing a mediastinal hematoma with no active bleeding during surgical exploration few hours later. The second case was a 28-year-old man that presented with a right atrial (RA) lead fracture and RV lead insulation failure in a dual-chamber defibrillator (ICD). CONCLUSION: Both the RA and RV leads were removed with mechanical sheaths, and a mediastinal hematoma was medically managed.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Masculino , Humanos , Pessoa de Meia-Idade , Adulto , Veia Cava Superior/cirurgia , Marca-Passo Artificial/efeitos adversos , Átrios do Coração/cirurgia , Hematoma , Remoção de Dispositivo/métodos , Desfibriladores Implantáveis/efeitos adversos
12.
Pacing Clin Electrophysiol ; 46(7): 645-656, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37247219

RESUMO

BACKGROUND: Toxic dilated cardiomyopathy (T-DCM) due to substance abuse is now recognized as a potential cause of severe left ventricular dysfunction. The burden of ventricular arrhythmias (VA) and the role of a prophylactic implantable cardioverter-defibrillator (ICD) are not well documented in this population. We aim to assess the usefulness of ICD implantation in a T-DCM cohort. METHODS: Patients younger than 65 years with a left ventricular ejection fraction (LVEF) < 35% followed at a tertiary center heart failure (HF) clinic between January 2003 and August 2019 were screened for inclusion. The diagnosis of T-DCM was confirmed after excluding other etiologies, and substance abuse was established according to the DSM-5 criteria. The composite primary endpoints were arrhythmic syncope, sudden cardiac death (SCD), or death of unknown cause. The secondary endpoints were the occurrence of sustained VA and/or appropriate therapies in ICD carriers. RESULTS: Thirty-eight patients were identified, and an ICD was implanted in 19 (50%) of these patients, only one for secondary prevention. The primary outcome was similar between the two groups (ICD vs. non-ICD; p = 1.00). After a mean follow-up of 33 ± 36 months, only two VA episodes were reported in the ICD group. Three patients received inappropriate ICD therapies. One ICD implantation was complicated with cardiac tamponade. Twenty-three patients (61%) had an LVEF ≥35% at 12 months. CONCLUSION: VA are infrequent in the T-DCM population. The prophylactic ICD benefit was not observed in our cohort. The ideal timing for potential prophylactic ICD implantation in this population needs further studies.


Assuntos
Cardiomiopatias , Cardiomiopatia Dilatada , Desfibriladores Implantáveis , Transtornos Relacionados ao Uso de Substâncias , Humanos , Desfibriladores Implantáveis/efeitos adversos , Volume Sistólico , Função Ventricular Esquerda , Arritmias Cardíacas/complicações , Cardiomiopatias/terapia , Cardiomiopatias/complicações , Morte Súbita Cardíaca/etiologia , Cardiomiopatia Dilatada/terapia , Transtornos Relacionados ao Uso de Substâncias/complicações , Fatores de Risco , Resultado do Tratamento
13.
Ann Intern Med ; 175(12): 1658-1665, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36343346

RESUMO

BACKGROUND: Implantable cardioverter defibrillators (ICDs) improve survival in patients at risk for cardiac arrest, but are associated with intravascular lead-related complications. The subcutaneous ICD (S-ICD), with no intravascular components, was developed to minimize lead-related complications. OBJECTIVE: To assess key ICD performance measures related to delivery of ICD therapy, including inappropriate ICD shocks (delivered in absence of life-threatening arrhythmia) and failed ICD shocks (which did not terminate ventricular arrhythmia). DESIGN: Randomized, multicenter trial. (ClinicalTrials.gov: NCT02881255). SETTING: The ATLAS trial. PATIENTS: 544 eligible patients (141 female) with a primary or secondary prevention indication for an ICD who were younger than age 60 years, had a cardiogenetic phenotype, or had prespecified risk factors for lead complications were electrocardiographically screened and 503 randomly assigned to S-ICD (251 patients) or transvenous ICD (TV-ICD) (252 patients). Mean follow-up was 2.5 years (SD, 1.1). Mean age was 49.0 years (SD, 11.5). MEASUREMENTS: The primary outcome was perioperative major lead-related complications. RESULTS: There was a statistically significant reduction in perioperative, lead-related complications, which occurred in 1 patient (0.4%) with an S-ICD and in 12 patients (4.8%) with TV-ICD (-4.4%; 95% CI, -6.9 to -1.9; P = 0.001). There was a trend for more inappropriate shocks with the S-ICD (hazard ratio [HR], 2.37; 95% CI, 0.98 to 5.77), but no increase in failed appropriate ICD shocks (HR, 0.61 (0.15 to 2.57). Patients in the S-ICD group had more ICD site pain, measured on a 10-point numeric rating scale, on the day of implant (4.2 ± 2.8 vs. 2.9 ± 2.2; P < 0.001) and 1 month later (1.3 ± 1.8 vs. 0.9 ± 1.5; P = 0.035). LIMITATION: At present, the ATLAS trial is underpowered to detect differences in clinical shock outcomes; however, extended follow-up is ongoing. CONCLUSION: The S-ICD reduces perioperative, lead-related complications without significantly compromising the effectiveness of ICD shocks, but with more early postoperative pain and a trend for more inappropriate shocks. PRIMARY FUNDING SOURCE: Boston Scientific.


Assuntos
Desfibriladores Implantáveis , Parada Cardíaca , Feminino , Humanos , Desfibriladores Implantáveis/efeitos adversos , Resultado do Tratamento , Arritmias Cardíacas , Fatores de Risco , Morte Súbita Cardíaca/etiologia
14.
N Engl J Med ; 380(20): 1895-1905, 2019 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-30883056

RESUMO

BACKGROUND: Infections after placement of cardiac implantable electronic devices (CIEDs) are associated with substantial morbidity and mortality. There is limited evidence on prophylactic strategies, other than the use of preoperative antibiotics, to prevent such infections. METHODS: We conducted a randomized, controlled clinical trial to assess the safety and efficacy of an absorbable, antibiotic-eluting envelope in reducing the incidence of infection associated with CIED implantations. Patients who were undergoing a CIED pocket revision, generator replacement, or system upgrade or an initial implantation of a cardiac resynchronization therapy defibrillator were randomly assigned, in a 1:1 ratio, to receive the envelope or not. Standard-of-care strategies to prevent infection were used in all patients. The primary end point was infection resulting in system extraction or revision, long-term antibiotic therapy with infection recurrence, or death, within 12 months after the CIED implantation procedure. The secondary end point for safety was procedure-related or system-related complications within 12 months. RESULTS: A total of 6983 patients underwent randomization: 3495 to the envelope group and 3488 to the control group. The primary end point occurred in 25 patients in the envelope group and 42 patients in the control group (12-month Kaplan-Meier estimated event rate, 0.7% and 1.2%, respectively; hazard ratio, 0.60; 95% confidence interval [CI], 0.36 to 0.98; P = 0.04). The safety end point occurred in 201 patients in the envelope group and 236 patients in the control group (12-month Kaplan-Meier estimated event rate, 6.0% and 6.9%, respectively; hazard ratio, 0.87; 95% CI, 0.72 to 1.06; P<0.001 for noninferiority). The mean (±SD) duration of follow-up was 20.7±8.5 months. Major CIED-related infections through the entire follow-up period occurred in 32 patients in the envelope group and 51 patients in the control group (hazard ratio, 0.63; 95% CI, 0.40 to 0.98). CONCLUSIONS: Adjunctive use of an antibacterial envelope resulted in a significantly lower incidence of major CIED infections than standard-of-care infection-prevention strategies alone, without a higher incidence of complications. (Funded by Medtronic; WRAP-IT ClinicalTrials.gov number, NCT02277990.).


Assuntos
Antibacterianos/administração & dosagem , Antibioticoprofilaxia , Infecções Bacterianas/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Cardiopatias/terapia , Minociclina/administração & dosagem , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/prevenção & controle , Rifampina/administração & dosagem , Idoso , Antibacterianos/efeitos adversos , Infecções Bacterianas/epidemiologia , Infecções Bacterianas/mortalidade , Feminino , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Minociclina/efeitos adversos , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/mortalidade , Rifampina/efeitos adversos , Método Simples-Cego , Padrão de Cuidado
15.
Pacing Clin Electrophysiol ; 45(5): 696-699, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34979041

RESUMO

Transvenous lead extraction (TLE) is used for lead infection, lead debulking, venous recanalization and device upgrades. Lead extraction is performed using specialized tools including locking stylets, mechanical or rotating sheaths, femoral snares or laser sheaths. The most feared complications associated with lead extraction are bleeding, vascular tear, cardiac avulsion and tamponade. Despite technological progress, the incidence of major procedural complications including death remains slightly above 1%. This case depicts an asymptomatic left common carotid artery (LCCA) to left innominate vein arteriovenous fistula (AVF) after laser-assisted TLE successfully treated with an endovascular covered stent.


Assuntos
Fístula Arteriovenosa , Desfibriladores Implantáveis , Marca-Passo Artificial , Fístula Arteriovenosa/etiologia , Fístula Arteriovenosa/cirurgia , Veias Braquiocefálicas , Artéria Carótida Primitiva , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Humanos , Lasers , Estudos Retrospectivos , Resultado do Tratamento
16.
Pacing Clin Electrophysiol ; 45(2): 281-284, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34730845

RESUMO

INTRODUCTION: Inadvertent implantation from the subclavian/axillary arteries is uncommon and has been rarely reported. Complications are frequent, mainly driven by thromboembolic events. Lead extraction, depending on the dwell time may be challenging and associated with thromboembolic events Case Report: We report the case of an 87-year-old man who had involuntarily pacemaker lead implanted into the left ventricle through the left subclavian artery. An extraction procedure was performed with surgical dissection to the artery and simple traction of the probe without complication. CONCLUSION: Percutaneous lead extraction using surgical dissection is a therapeutic option for less than one year old left ventricle inadvertent lead implantation.


Assuntos
Remoção de Dispositivo , Ventrículos do Coração , Erros Médicos , Marca-Passo Artificial , Artéria Subclávia , Idoso de 80 Anos ou mais , Ecocardiografia Tridimensional , Eletrocardiografia , Humanos , Masculino
17.
J Card Surg ; 37(11): 3598-3606, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36104934

RESUMO

BACKGROUND: Atrial fibrillation (AF) is common in patients with reduced left ventricle ejection fraction (RLVEF). The impact of concomitant surgical atrial fibrillation ablation (SAFA) in patients with RLVEF is uncertain. The purpose of this study was to assess the outcomes of concomitant SAFA in patients with RLVEF undergoing heart surgery on heart failure (HF) rehospitalization and mortality. METHODS: Using a local registry and electronic health records linked with provincial civil register survival data from July 2002 to April 2019, we analyzed treatment and outcomes in a cohort of patients with AF and HF defined by left ventricle ejection fraction (LVEF) ≤40%. Health records were used to collect treatment and International Classification of Diseases (ICD 10) codes to determine outcomes. A negative binomial model was used to compare outcomes such as all-cause mortality and rehospitalization for heart failure. RESULTS: The cohort included 682 patients with RLVEF and AF who underwent coronary artery bypass graft and/or valve surgery. A total of 196 patients (29%) underwent concomitant SAFA. After matching, 132 patients with concomitant SAFA were compared to 159 patients who did not undergo concomitant SAFA. At 6.0 ± 3.7 years of follow-up, concomitant SAFA was not associated with lower all-cause mortality (p = .9861) and reduction in rehospitalizations for heart failure decompensation (p = .31) compared to patients who did not have concomitant SAFA performed. Postoperatively, concomitant SAFA might be associated with less vasopressor and mechanical support use (p = .01). CONCLUSIONS: Concomitant SAFA during index cardiac surgery is safe but does not reduce mortality or rehospitalizations for HF. The effects of concomitant SAFA in the context of RLVEF need to be better studied with prospective trials.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/cirurgia , Humanos , Estudos Prospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
18.
Exp Physiol ; 106(3): 683-699, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33480457

RESUMO

NEW FINDINGS: What is the role of SCN5A-C683R? SCN5A-C683R is a novel variant associated with an uncommon phenotype of adrenaline-triggered ventricular arrhythmia in the absence of a distinct ECG phenotype. What is the main finding and its importance? Functional studies demonstrated that NaV 1.5/C683R results in a mixed electrophysiological phenotype with gain-of-function (GOF) and loss-of-function (LOF) properties compared with NaV 1.5/wild type. Gain-of-function properties are characterized by a significant increase of the maximal current density and a hyperpolarizing shift of the steady-state activation. The LOF effect of NaV 1.5/C683R is characterized by increased closed-state inactivation. Electrophysiological properties and clinical manifestation of SCN5A-C683R are different from long-QT-3 or Brugada syndrome and might represent a distinct inherited arrhythmia syndrome. ABSTRACT: Mutations of SCN5Ahave been identified as the genetic substrate of various inherited arrhythmia syndromes, including long-QT-3 and Brugada syndrome. We recently identified a novel SCN5A variant (C683R) in two genetically unrelated families. The index patients of both families experienced adrenaline-triggered ventricular arrhythmia with cardiac arrest but did not show a specific ECG phenotype, raising the hypothesis that SCN5A-C683R might be a susceptibility variant and the genetic substrate of distinct inherited arrhythmia. We conducted functional cellular studies to characterize the electrophysiological properties of NaV 1.5/C683R in order to explore the potential pathogenicity of this novel variant. The C683R variant was engineered by site-directed mutagenesis. NaV 1.5/wild type (WT) and NaV 1.5/C683R were expressed in tsA201 cells. Electrophysiological characterization of C683R was performed using the whole-cell patch-clamp technique. Adrenergic stimulation was mimicked by exposure to the protein kinase A activator 8-CPT-cAMP. The impact of ß-blockers was tested by exposing NaV 1.5/WT and NaV 1.5/C683R currents to propranolol and nadolol. C683R resulted in a co-association of gain-of-function and loss-of-function properties of NaV 1.5. Gain-of-function properties were characterized by a significant increase of the maximal NaV 1.5 current density compared with NaV 1.5/WT (861 ± 309 vs. 627 ± 489 pA/pF; P < 0.05, n ≥ 9) that was potentiated in NaV 1.5/C683R with 8-CPT-cAMP stimulation (869 ± 287 vs. 607 ± 320 pA/pF; P < 0.05, n ≥ 12). C683R also resulted in a significant hyperpolarizing shift in the voltage of steady-state activation (-65.4 ± 3.0 vs. -57.2 ± 4.8 mV; P < 0.001), resulting in an increased window current compared with WT. The loss-of-function effect of NaV 1.5/C683R was characterized by significantly increased closed-state inactivation compared with NaV 1.5/WT (P < 0.05). C683R is a novel SCN5A variant resulting in a co-association of gain-of-function and loss-of-function properties of the cardiac sodium channel NaV 1.5. The phenotype is characterized by adrenaline-triggered ventricular arrhythmias. Electrophysiological properties and clinical manifestations are different from long-QT-3 or Brugada syndrome and might represent a distinct inherited arrhythmia syndrome.


Assuntos
Arritmias Cardíacas , Epinefrina , Mutação com Ganho de Função , Canal de Sódio Disparado por Voltagem NAV1.5 , Arritmias Cardíacas/induzido quimicamente , Arritmias Cardíacas/genética , Arritmias Cardíacas/metabolismo , Humanos , Mutação/genética , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Canal de Sódio Disparado por Voltagem NAV1.5/metabolismo
19.
Europace ; 23(8): 1319-1323, 2021 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-33608700

RESUMO

AIMS: Cardiac implantable electronic devices with device advisories have the potential of device malfunction. Remote monitoring (RM) of devices has been suggested to allow the identification of abnormal device performance and permit early intervention. We sought to describe the outcomes of patients with and without RM in devices subject to the Abbott Premature Battery Depletion (PBD) advisory with data from a Canadian registry. METHODS AND RESULTS: Patients with an Abbott device subject to the PBD advisory from nine implantable cardioverter defibrillator (ICD) implanting centres in Canada were included in the registry. The use of RM was identified from baseline and follow-up data in the registry. The primary outcome was detection of PBD and all-cause mortality. A total of 2666 patients were identified with a device subject to the advisory. In all, 1687 patients (63.2%) had RM at baseline. There were 487 deaths during follow-up. At a mean follow-up of 5.7 ± 0.7 years, mortality was higher in those without a remote monitor compared with RM at baseline (24.7% vs. 14.5%; P < 0.001). Pre-mature battery depletion was identified in 36 patients (2.1%) with RM vs. 7 (0.7%) without RM (P = 0.004). Time to battery replacement was significantly reduced in patients on RM (median 5 vs. 13 days, P = 0.001). CONCLUSION: The use of RM in patients with ICD and cardiac resynchronization therapy under advisory improved detection of PBD, time to device replacement, and was associated with a reduction in all-cause mortality. The factors influencing the association with mortality are unknown and deserve further study.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Canadá , Eletrônica , Humanos , Sistema de Registros
20.
Europace ; 23(9): 1446-1455, 2021 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-33755136

RESUMO

AIM: The Prevention of Arrhythmia Device Infection Trial (PADIT) infection risk score, developed based on a large prospectively collected data set, identified five independent predictors of cardiac implantable electronic device (CIED) infection. We performed an independent validation of the risk score in a data set extracted from U.S. healthcare claims. METHODS AND RESULTS: Retrospective identification of index CIED procedures among patients aged ≥18 years with at least one record of a CIED procedure between January 2011 and September 2014 in a U.S health claims database. PADIT risk factors and major CIED infections (with system removal, invasive procedure without system removal, or infection-attributable death) were identified through diagnosis and procedure codes. The data set was randomized by PADIT score into Data Set A (60%) and Data Set B (40%). A frailty model allowing multiple procedures per patient was fit using Data Set A, with PADIT score as the only predictor, excluding patients with prior CIED infection. A data set of 54 042 index procedures among 51 623 patients with 574 infections was extracted. Among patients with no history of prior CIED infection, a 1 unit increase in the PADIT score was associated with a relative 28% increase in infection risk. Prior CIED infection was associated with significant incremental predictive value (HR 5.66, P < 0.0001) after adjusting for PADIT score. A Harrell's C-statistic for the PADIT score and history of prior CIED infection was 0.76. CONCLUSION: The PADIT risk score predicts increased CIED infection risk, identifying higher risk patients that could potentially benefit from targeted interventions to reduce the risk of CIED infection. Prior CIED infection confers incremental predictive value to the PADIT score.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Adolescente , Adulto , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Atenção à Saúde , Eletrônica , Humanos , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/prevenção & controle , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA