Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
J Vasc Surg ; 79(4): 887-892, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38128846

RESUMO

OBJECTIVE: We evaluated the midterm results of atherectomy-assisted angioplasty for the treatment of femoropopliteal lesions and the identification of possible subgroups of patients with superior outcomes. METHODS: We conducted a single-center, physician-initiated, nonindustry-sponsored retrospective analysis of patients with Rutherford category ranging from II to V and de novo occlusive or stenotic lesions of the superficial femoral (SFA) and/or popliteal arteries treated with atherectomy-assisted angioplasty (Jetstream rotational atherectomy + drug-eluting ballooning). In cases of subintimal recanalization or patients without an SFA stamp, with previous ipsilateral bypass surgery, systemic coagulopathy, end-stage renal disease requiring hemodialysis, life expectancy of <12 months, and intolerance to aspirin, clopidogrel, and/or heparin were excluded. RESULTS: In a total of 103 enrolled patients, the median SFA and/or popliteal lesion length was 80 mm (interquartile range, 61.2 mm) with 73 lesions being occlusive (70.9%) and 84 (81.5%) classified as Fanelli calcification score 3 and 4. Technical success was met in 96.1% of cases (n = 99) at a median operative time of 108 minutes. Adjunctive stenting was needed in 10 patients (9.8%). At a median follow-up of 18.0 ± 10.8 months, Rutherford class clinical improvement was present in 77 patients (74.8%), and 7 patients (6.79%) presented target lesion occlusion needing reintervention in 6 cases (5.82%). The primary patency rates were 97% at 12 months and 83% at 24 months with secondary patency rates of 99% at 12 months and 91% at 24 months of follow-up. There were no significant differences when treating differently located lesions, diabetic vs nondiabetic patients, or comparing experienced vs nonexperienced operators. CONCLUSIONS: The use of rotational atherectomy and drug-eluting balloons for the treatment of severe femoropopliteal disease showed relatively low need for bailout stenting and good midterm primary patency rates. The influence of lesion location, diabetes mellitus, or operator experience did not show statistically different results in terms of patency. Longer term outcomes and comparative analysis are needed to consolidate further clinical evidence.


Assuntos
Angioplastia com Balão , Aterectomia Coronária , Doença Arterial Periférica , Humanos , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Angioplastia com Balão/efeitos adversos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/cirurgia , Aterectomia/efeitos adversos , Aterectomia/métodos , Grau de Desobstrução Vascular
2.
J Endovasc Ther ; : 15266028241261661, 2024 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-38881034

RESUMO

PURPOSE: The iliac veins are the least frequent location for venous aneurysms, with only a few cases described globally. The etiology and clinical presentation of this extremely rare entity is diverse and unclear and no treatment consensus has been reached yet. Our purpose is to present an interesting iliac vein aneurysm (IVA) case that we treated in our department, with a brief review of the literature. CASE REPORT: We report a case of a 74-year-old male patient with a giant, 55 mm in diameter, asymptomatic, right common IVA, with concurrent aplasia of the left common iliac vein and an extensive network of venous collaterals. The patient was treated, under general anesthesia, with total endovascular iliocaval reconstruction through implantation of a 32 × 100 mm thoracic aortic tubular Ankura stent graft. The computed tomography venography at first-month follow-up showed the complete exclusion of the IVA, without any endoleak and the patient remains up to date free of symptoms and thromboembolic events. CONCLUSION: Twelve cases of endovascular treatment of IVA have been reported so far, and our case is the first with implantation of a thoracic aortic stent graft. Our results suggest that this technique is safe, effective, and may be considered for appropriately selected patients. CLINICAL IMPACT: This is the first case with total endovascular repair of an iliac vein aneurysm with contralateral iliac vein aplasia through endovenous implantation of a thoracic aortic stent-graft. Our results suggest that this technique is safe and effective and thus, may be considered for appropriately selected cases.

3.
Lasers Med Sci ; 39(1): 165, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38935309

RESUMO

We sought to assess the efficacy and safety of endovenous laser ablation utilizing a 980 nm device versus a 1470 nm device in the treatment of lower limb venous insufficiency. We performed a systematic review adhering to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 statement. A research on PubMed, Scopus and Web of science for articles published by January 2024 was conducted. The primary endpoint was great saphenous vein (GSV) and truncal vein occlusion. Eleven studies encompassing 3061 patients and 3193 truncal veins, were included. The 1470 nm device demonstrated superior truncal vein and GSV occlusion outcomes compared to the 980 nm device at the early, one-year, and medium to long-term follow-up intervals. Odds ratios (OR) were 2.79(95%CI:1.31-5.94), 2.22(95%CI:1.21-4.07), and 2.02(95%CI:1.24-3.29) for truncal veins and 2.54(95%CI:1.119-5.41), 2.06(95%CI:1.07-3.95) and 2.04(95%CI:1.25-3.33) for GSV, across the respective intervals. While both devices demonstrated minimal, deep vein thrombosis (DVT), endovenous heat-induced thrombosis (EHIT) ≥ 2, and burn estimates, the 1470 nm device exhibited improved paresthesia, risk ratio (RR), 0.51(95%CI:0.34-0.77) and pain outcomes, standardized mean difference (SMD), -0.62(95%CI:-0.99to-0.25). Subgroup analysis displayed enhanced occlusion outcomes with the 1470 nm device for the six-month and one-year intervals, irrespective of fiber type. Radial fibers were associated with improved paresthesia outcomes (ß=-0.9520,p = 0.03). This review emphasized the enhanced efficacy of the 1470 nm device over the 980 nm device, regardless of fiber type. Radial fibers showed promise for improved paresthesia outcomes, suggesting similar safety profiles for both systems. Conclusive remarks on pain outcomes were impeded by data limitations.


Assuntos
Procedimentos Endovasculares , Terapia a Laser , Insuficiência Venosa , Humanos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Procedimentos Endovasculares/efeitos adversos , Terapia a Laser/instrumentação , Terapia a Laser/métodos , Terapia a Laser/efeitos adversos , Resultado do Tratamento , Insuficiência Venosa/cirurgia
4.
J Vasc Surg ; 77(3): 941-956.e1, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35948244

RESUMO

OBJECTIVE: To provide an updated systematic literature review summarizing current evidence on aortic neck dilatation (AND) after endovascular aortic aneurysm repair (EVAR) in patients with infrarenal abdominal aortic aneurysm. METHODS: An extensive electronic search in major electronic databases was conducted between January 2000 and December 2021. Eligible for inclusion were observational studies that followed up with patients (n ≥ 20) undergoing EVAR with self-expanding endografts, for 12 or more months, evaluated AND with computed tomography angiography and provided data on relevant outcomes. The primary end point was the incidence of AND after EVAR, and the secondary end points were the occurrence of type Ia endoleak, stent graft migration, secondary rupture, and reintervention. RESULTS: We included 34 studies with a total sample of 12,038 patients (10,413 men; median age, 71 years). AND was defined clearly in 18 studies, but significant differences in AND definition were evidenced. The pooled incidence of AND based on quantitative analysis of 16 studies with a total of 9201 patients (7961 men; median age, 72 years) was calculated at 22.9% (95% confidence interval [CI], 14.4-34.4) over a follow-up period ranging from 12 months to 14 years. The risk of a type Ia endoleak was significantly higher in AND patients compared with those without AND (odds ratio, 2.95; 95% CI, 1.10-7.93; P = .030). Similarly, endograft migration was more common in the AND group compared with the non-AND group (odds ratio, 5.95; 95% CI, 1.80-19.69; P = .004). The combined incidence of secondary rupture and reintervention did not differ significantly between the two groups, even though the combined effect was in favor of the non-AND group. CONCLUSIONS: Proximal AND after EVAR is common and occurs in a large proportion of patients with infrarenal abdominal aortic aneurysm. AND can influence the long-term durability of proximal endograft fixation and is significantly related to adverse outcomes, often leading to reinterventions.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Idoso , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Resultado do Tratamento , Dilatação/efeitos adversos , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular/efeitos adversos
5.
J Endovasc Ther ; : 15266028231172379, 2023 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-37166154

RESUMO

PURPOSE: A variety of last-generation endografts are currently available for standard endovascular repair (EVAR) of infrarenal abdominal aortic aneurysms (AAAs). The purpose of this study is to report the preliminary clinical outcomes of the Minos trimodular stent-graft system, which was recently introduced to the European market. MATERIALS AND METHODS: Between February 2020 and 2022, we treated 41 consecutive AAA patients (mean age 72.2±8.5, 37 males) with elective standard EVAR using the Minos. The mean maximum diameter of AAAs was 54.7±6.6 mm, the mean proximal neck's (PN) diameter was 24.8±2.7 mm, while the relevant length and angulation were 16.0 mm and 21.7°, respectively. Overall, 22 (53.6%) patients presented with shorter and angulated PN, according to the stent-graft's instructions of use, and in 6 (14.6%) patients the PN angulation >60° was combined with concomitant iliac angulation >60°. Eleven (26.8%) EVARs were performed with concomitant enormous iliac artery narrowing and tortuosity. Finally, in 19 (46.3%) AAAs, the distal iliac landing zone was aneurysmatic and they were treated with the bell-bottom technique in 17 patients and with limb extension to the external iliac artery in two cases. We evaluated technical and clinical success of the index procedures, which was based on the combination of five factors: freedom from EVAR-related mortality, from graft-related endoleak of any type, from migration at any part of graft as well the absence of notable increase AAA's sac maximum diameter and the patency of bifurcated stent-graft and of access vessels. RESULTS: Primary technical and clinical success of index procedures was 100%. During a median 12-month radiological follow-up the clinical success remained 100%. No type I or III endoleak, stent-graft migration, EVAR-related death, AAA rupture, or graft-related adverse events or reinterventions were documented. Four (9.8%) type II endoleaks were detected with stable AAA sac diameter. The overall incidence of sac regression was 34.1% (n=14). CONCLUSION: The preliminary results of our series showed that Minos provided excellent feasibility and safety features even through angulated and tortuous iliac vessels and in short and angulated PNs. The overall clinical success at 1 year suggests that performance of Minos follows very high standards. Further validation of these promising results with long-term data is acquired to complete the evaluation of this recently introduced stent-graft system. CLINICAL IMPACT: The current study explored the clinical performance of a new in market ultra-low profile bifurcated abdominal aortic stent-graft, the MINOS. The early and 12-month results of study suggest that implantation of this stent-graft in standard EVAR, even in hostile proximal aortic neck and iliac vessels conditions, follows very high clinical standards and encourage the further clinical use of MINOS.

6.
J Endovasc Ther ; : 15266028231167998, 2023 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-37078515

RESUMO

PURPOSE: To measure the long-term proximal aortic neck dilatation (AND) after elective endovascular aortic aneurysm repair (EVAR) with a variety of contemporary, third-generation, endograft devices. MATERIALS AND METHODS: This is a noninterventional prospective cohort study of 157 patients that underwent standard EVAR with self-expanding abdominal endografts. Patients' recruitment lasted from 2013 to 2017, and postoperative follow-up was up to 5 years. A computed tomography angiography (CTA) was performed at the first month and then at 1, 2, and 5 years. Proximal aortic neck's (PAN) basic morphological characteristics (diameter, length, angulation) were measured based on the analysis of CTA in a standardized fashion. Neck-related adverse events, such as migration, endoleak or rupture, and reinterventions were recorded. RESULTS: Significant straightening of the PAN was evident even in the first-month CTA with concurrent neck shortening that became significant at 5 years. Both the suprarenal aorta and the PAN significantly dilated overtime, with PAN dilating more progressively. Mean neck dilatation at the juxtarenal level was 0.8±0.4 mm at 1 year, 1.8±0.8 mm at 2 years, and 3.9±1.7 mm at 5 years, with a mean neck dilatation rate of 0.07 mm/month overall. The incidence of AND ≥2.5 mm was 37.2% at 2 years and 58.1% at 5 years after EVAR and was considered important (≥5 mm) in 11.5% of patients at 2 years and 30.6% of patients at 5 years. A multivariate analysis performed showed that the endograft oversizing, the preoperative neck diameter, and the preoperative abdominal aortic aneurysm sac diameter served as independent predictors of AND at 5 years. At the 5-year follow-up, 8 late type Ia endoleaks (6.5%) and 7 caudal migrations (5.6%) were identified, while no late ruptures were reported. In total, 11 late endovascular reinterventions (8.9%) were performed. Overall, proximal neck-related adverse outcomes (5/7 migrations and 5/8 endoleaks) and reinterventions (7/11) were significantly associated with the presence of important late AND. CONCLUSION: Proximal AND after EVAR is common. It can influence the long-term durability of proximal endograft fixation and is significantly associated with adverse outcomes, often leading to reinterventions. A systemic and extended surveillance protocol is needed for maintenance of good long-term results. CLINICAL IMPACT: This is a thorough and systematic analysis of the long-term geometric remodeling of the proximal aortic neck after EVAR, that highlights the importance of a strict, and extended surveillance protocol for maintenance of good long-term results of EVAR.

7.
J Vasc Surg ; 73(2): 433-442, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32473338

RESUMO

OBJECTIVE: In the treatment of pararenal abdominal aortic aneurysms and aortic pathologic processes, chimney endovascular aneurysm repair (CHEVAR) represents an alternative technique for urgent cases. The aim of the study was to evaluate the outcomes of CHEVAR in the elective setting. METHODS: We performed a retrospective analysis of prospectively collected records of 165 consecutive asymptomatic CHEVAR patients who were treated between March 2009 and January 2018 with the Endurant stent graft (Medtronic, Santa Rosa, Calif). A total of 244 chimney grafts (CGs) were implanted. The primary end point was clinical success, defined as freedom from procedure-related mortality, persistent type IA endoleak, occlusion or high-grade stenosis (>70%) of CGs, and any chimney technique-related secondary procedure for the entire follow-up period. Secondary clinical success included patients with successful treatment of a primary end point with a secondary endovascular procedure. RESULTS: All 244 targeted chimney vessels were successfully cannulated. Total perioperative morbidity was 7.8% (n = 13), including 3 (1.8%) cases of bowel ischemia, 1 (0.6%) patient with renal ischemia, and 1 patient (0.6%) with stroke. Median follow-up was 25.5 ± 2.2 months. Both 30-day and follow-up procedure-related mortality rates were 1.8% (n = 3). Primary and secondary freedom from persistent type IA endoleak rates were 96.4% (n = 159) and 99.4% (n = 164), respectively. Primary and secondary CG patency rates were 92.2% (n = 225) and 95.9% (n = 234), respectively. The rate of reinterventions related to the chimney technique was 10.9% (n = 18), and 83.3% of them were performed by endovascular means. The estimated cumulative primary patency and freedom from persistent type IA endoleak were 87.5% and 95.3%, respectively, and the primary and secondary clinical successes rates at midterm were 80.3% and 87.5%, respectively. CONCLUSIONS: The elective use of CHEVAR with the Endurant stent graft in our series showed favorable midterm clinical results, which are similar to the published results of other total endovascular modalities. A prospective randomized trial of elective treatment of pararenal abdominal aortic aneurysms and aortic pathologic processes with current endovascular options is needed to assess the value of CHEVAR in the elective setting.


Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/patologia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Comorbidade , Procedimentos Cirúrgicos Eletivos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
8.
J Endovasc Ther ; 28(4): 585-592, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34060354

RESUMO

OBJECTIVE: To evaluate early and follow-up outcomes following bilateral use of iliac branch devices (IBD) for aortoiliac endografting and assess the impact of center volume. We used data from the pELVIS international multicentric registry. METHODS: For the purpose of this study, only those patients receiving concomitant bilateral IBD implantation were analyzed. To assess the impact that procedural volume of bilateral IBD implantation could have on early and follow-up outcomes, participating institutions were classified as Site(s) A if they had performed >10 and/or >20% concomitant bilateral IBD procedure, otherwise they were classified as Site(s) B. Endpoints of the analysis included early (ie, 30-day) mortality and morbidity, as well as all-cause and aneurysm-related mortality during follow-up. Additional endpoints that were evaluated included IBD-related reinterventions, IBD occlusion or stenosis requiring reintervention (ie, loss of primary patency), and IBD-related type I endoleak. RESULTS: Overall, 96 patients received bilateral IBD implantation (out of 910 procedures collected in the whole pELVIS cohort), of whom 65 were treated at Site A (ie, Group A) and 31 were treated at Site(s) B (ie, Group B). In total, only 1 death occurred within 30 days from bilateral IBD implantation, and 9 patients experienced at least 1 major complication without any significant difference between subjects in Group A versus those in Group B (10.8% vs 6.5%, p=0.714). In the overall cohort, the 2-year freedom from IBD-related type I endoleaks and IBD primary patency were 96% and 92%, respectively; no significant differences were seen in those rates between Group A or Group B (95% vs 100%, p=0.335; 93% vs 88%, p=0.470). Freedom from any IBD-related reinterventions was 83% at 2 years, with similar rates between study groups (85% vs 83%, p=0.904). CONCLUSIONS: Within the pELVIS registry, concomitant bilateral IBD implantation is a safe and feasible technique for management of aortoiliac aneurysms in patients with suitable anatomy. Despite increased technical complexity, effectiveness of the repair is satisfactory with low rates of IBD-related adverse events at mid-term follow-up. Procedural volume does not seem to affect technical or clinical outcomes after bilateral use of IBD, which remains a favorable treatment option in selected patients.

9.
J Vasc Surg ; 66(6): 1686-1695, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28583728

RESUMO

OBJECTIVE: Hostile proximal aortic neck (HN) challenges the suitability for standard endovascular aneurysm repair (EVAR) of patients at high risk for "open" repair. However, there has been little if any focus placed on the individual role of the "nonlength" HN features in EVAR outcomes. The aim of this study was to evaluate their individual and potentially predictive role in outcomes of EVAR under HN conditions. METHODS: Data of 156 consecutive EVAR patients with short (<15 mm) HN, treated with the Endurant device (Medtronic Cardiovascular, Santa Rosa, Calif) at three European academic vascular centers between 2007 and 2015, were collected and retrospectively analyzed. All patients had at least one of the four well-known nonlength HN criteria (width >32 mm or bulge, angulation >60 degrees, reverse taper anatomy, and circumferential thrombus or calcification >50%) and underwent standard EVAR without additional techniques, such as use of chimney grafts or endoanchors. Primary end points were absence of type IA endoleak at 1 month and midterm follow-up and aneurysm sac stabilization or shrinkage. Secondary end points were 30-day mortality, overall survival, and secondary interventions related to EVAR. The study cohort was classified in two subgroups related to neck length (length <10 mm and length between 10 and 14 mm) as well as in two subgroups according to on-label or off-label stent graft use. RESULTS: Mean clinical and radiologic follow-up was 41.1 ± 24.7 and 31.7 ± 19.0 months, respectively. Overall EVAR-related mortality was 1.9% (n = 3). The total type IA endoleak rate was 5.8% (n = 9). In four patients, the type IA endoleak was detected intraoperatively and solved by endovascular means. A type IA endoleak was detected in three patients at 1 month and in two patients at 2-year follow-up. During follow-up, five patients showed an increase of aneurysm diameter due to type II endoleak and were treated by secondary endovascular reinterventions. The total number of all EVAR-related secondary procedures in the midterm was 12 (7.7%). Univariate analysis showed that the center of treatment and the clinical or anatomic features were not associated with adverse outcomes. Multiple regression and Cox regression analysis of HN features revealed that reverse taper anatomy (conical neck) was the single and significantly associated predictor of proximal EVAR failure (P < .012). Width >32 mm, angulation >60 degrees, and calcification or thrombus were not associated with adverse outcomes. Analysis between HN length cohorts and between on-label and off-label subgroups revealed no difference in outcomes. CONCLUSIONS: A conical neck in hostile anatomies represents the single strongest factor associated with proximal failure of standard EVAR. This finding should be considered and highlighted apart from the length of the infrarenal neck to prevent midterm failure of standard EVAR.


Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Distribuição de Qui-Quadrado , Angiografia por Tomografia Computadorizada , Endoleak/diagnóstico por imagem , Endoleak/mortalidade , Endoleak/terapia , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Europa (Continente) , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Modelos de Riscos Proporcionais , Desenho de Prótese , Retratamento , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Falha de Tratamento
10.
Cytokine ; 91: 140-144, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28073026

RESUMO

Visfatin is an adipokine molecule acting as an essential coenzyme in multiple cellular redox reactions. The increased serum levels of Visfatin have been correlated with metabolic syndrome and endothelial homeostasis. In this study we investigate the possible relationship of Visfatin serum levels with the severity and location of atherosclerotic peripheral arterial occlusive disease (PAOD). Study protocol included 45 consecutive PAOD and 20 Control patients with age >55years old. Definition of PAOD was based in Rutherord's classification (RC). End-stage PAOD patients (RC-V & -VI) were excluded from study. Data were collected prospectively and included age, gender, atherosclerotic risk factors and the body mass index (BMI). In PAOD patients recorded the PAOD's clinical stage and the presence of carotid stenosis >50%. PAOD patients divided in two subgroups, those with mild (RC-I & -II) and moderate disease (RC-III & -IV). In all serum samples Visfatin was measured, blindly, twice by anosoenzymatic technique. Statistical analysis was performed by non-parametric Mann-Whitney U test, Pearson's chi-square, One Way Anova and Kruskall-Wallis tests, as appropriate. The mean Visfatin value in PAOD and Control groups were 38.5±16.0 and 13.9±3.8ng/ml respectively (p<0.0005). In-PAOD subgroup of patients the visfatin values were not affected by demographics, BMI and atherosclerotic risk factors (p>0.05). Univariate analysis showed that severity of PAOD (mild vs severe), presence of carotid stenosis >50% and multilevel disease significantly affected outcomes (p=0.018, p=0.010 and p=0.006 respectively). In multivariate regression analysis severity of PAOD was the solely factor with strong correlation with high visfatin values (p=0.001). High Visfatin levels seem to be strongly correlated with the presence and severity of PAOD. Further and in depth investigation is needed to define the possible role of Visfatin in atherosclerosis and it's value as a potential prognostic biomarker of PAOD.


Assuntos
Índice de Massa Corporal , Citocinas/sangue , Nicotinamida Fosforribosiltransferase/sangue , Doença Arterial Periférica/sangue , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/patologia , Doença Arterial Periférica/fisiopatologia , Estudos Prospectivos , Fatores de Risco
11.
J Cardiovasc Surg (Torino) ; 65(2): 119-123, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38618696

RESUMO

This article summarizes the key findings in literature up to date on the endovascular treatment of complex abdominal aortic aneurysms (AAAs) employing the chimney technique. Additionally, an unexplored pitfall is described regarding the target vessel angulation. Although balloon-expandable covered stents present more favorable configuration in downward-oriented target vessels, transverse and upward-oriented target vessels may benefit from other endovascular techniques imploring careful case planning and further investigation on the topic.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Prótese Vascular , Artéria Renal , Stents , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Humanos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Artéria Renal/cirurgia , Artéria Renal/diagnóstico por imagem , Resultado do Tratamento , Procedimentos Endovasculares/instrumentação , Desenho de Prótese , Fatores de Risco
12.
J Clin Med ; 13(11)2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38892949

RESUMO

Background: Endovascular treatment of lower-extremity peripheral disease (PAD) is associated with higher complication rates and suboptimal outcomes in women. Atherectomy has shown favourable outcomes in calcified lesions, minimising the incidence of stent placement caused by recoil or flow-limiting dissection. To date, there are no published mid-term outcomes evaluating the performance of atherectomy differentiated by sex. This study aims to evaluate sex-specific outcomes and prognostic factors affecting the results of atherectomy-assisted endovascular treatment in severe PAD. Methods: A retrospective analysis was conducted at a single centre in Germany, initiated by physicians and not sponsored by industry, on patients presenting with Rutherford categories ranging from III to V and featuring de novo occlusive or stenotic lesions of the superficial femoral (SFA) and/or popliteal arteries. The intervention involved rotational atherectomy-assisted angioplasty utilising the Jetstream (Boston, US®) device. The point of interest of this study was postinterventional clinical improvement as well as mid-term outcomes, including primary patency, over a targeted 2-year follow-up period. Statistical analysis utilised Cox regression (survival analysis) to calculate hazard ratios according to sex category. Comparative survival analysis was performed using the log-rank test and visually represented through Kaplan-Meier curves. Risk factors associated with absence of clinical improvement were examined across both sex groups utilising the chi-square or Fisher exact test, as appropriate. Results: A total of 98 patients (103 limbs) were initially included, with >75% having moderate-to-severe lesion calcification (>50%). A total of 84 patients (97 limbs, 62 male and 35 female) proceeded to a 2-year follow-up (mean 16.4 months for males and 16.1 for females) after a successful index procedure. Age distribution, Rutherford class, diabetes, chronic kidney disease (CKD), target vessel, lesion type, and length were balanced among both groups. Similar primary patency rates, of 89% among female and 91% among male limbs, were observed (p = 0.471). Female patients exhibited a lower rate of clinical improvement based on the Rutherford scale in comparison to males (80.6% vs. 94.5%, p = 0.048). CDK was the only significant prognostic factor across pooled data (odds ratio for CKD: 15.15, p < 0.001). Conclusions: Rotational atherectomy showed comparably high rates of mid-term primary patency, with low rates of bailout stent placement. These findings highlight the beneficial use of atherectomy in female patients who are per se at risk for higher rates of complications during and after endovascular interventions.

13.
J Clin Med ; 13(5)2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38592186

RESUMO

The aim of the study is to evaluate the safety and effectiveness of rotational atherectomy-assisted balloon angioplasty (BTK-RA) for the treatment of isolated below the knee (BTK) atherosclerotic lesions and to compare the outcomes to plain old balloon angioplasty (POBA). Between January 2020 and September 2023, 96 consecutive patients with chronic limb threatening ischemia (CTLI) and isolated BTK-lesions underwent POBA (group A) or BTK-RA (group B). The primary outcome measures were: periprocedural technical success, primary patency, postoperative increase of the ankle branchial index (ABI), target lesion revascularization (TLR), limb salvage, minor amputation and death. Both techniques had similar technical success, operative time, intraprocedural complications and bailout stent implantations, independently of the operator's experience. Group B had significantly higher primary patency rates (93.5% vs. 72.0%, respectively, p = 0.006), TLR (2.1% vs. 24%, p = 0.057), lower in-hospital stay (2.0-3.0 vs. 4.0-6.0 days, respectively, p < 0.001) and higher postoperative ABI (0.8-0.2 vs. 0.7-0.1, respectively, p = 0.008), compared to group A. Significant differences (POBA n: 20, 40%, BTK-RA n = 3, 6.5%) were found in minor amputation rates between the two groups (p < 0.001), while the respective limb salvage rates were similar in both groups (94.0% vs. 97.8%, p = 0.35). The use of BTK-RA for the treatment of BTK-lesions in patients with CTLI showed significant clinical advantages in comparison to POBA.

14.
Vasc Specialist Int ; 40: 12, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38661144

RESUMO

Purpose: This study aims to investigate whether routine screening for silent pulmonary embolism (PE) can be justified in patients with deep vein thrombosis (DVT). Materials and Methods: We retrospectively analyzed the medical records of 201 patients with lower-extremity DVT admitted to the vascular surgery department of a single tertiary university center between 2019 and 2023. All patients underwent clinical evaluation, basic laboratory exams, a whole-leg colored duplex ultrasound, and a computed tomography pulmonary angiography (CTPA), to screen for an occult, underlying PE. Results: The overall incidence of silent PE was 48.8%. The median admission D-dimer level was significantly higher in patients with silent PE than in those without PE (9.60 vs. 5.51 mg/L, P=0.001). A D-dimer value ≥5.14 mg/L was discriminant for predicting silent PE, with a sensitivity of 68.2% and a specificity of 59.3%. Silent PE was significantly more common on the right side, with the embolus located at the main pulmonary, lobar, segmental, and subsegmental arteries in 29.6%, 32.7%, 20.4%, and 17.3%, respectively. A higher incidence of occult PE was observed in patients with iliofemoral DVT (P=0.037), particularly when the thrombus extended to the inferior vena cava (P=0.003). Moreover, iliofemoral DVT was associated with a larger size and a more proximal location of the embolus (P=0.041). Multivariate logistic regression showed that male sex (odds ratio [OR]=2.46, 95% confidence interval [CI]: 1.39-3.53; P=0.026), cancer (OR=2.76, 95% CI: 1.45-4.07; P=0.017), previous venous thromboembolism (VTE) history (OR=2.67, 95% CI: 1.33-4.01; P=0.022), D-dimer value ≥5.14 mg/L (OR=2.24, 95% CI: 1.10-3.38; P=0.033), iliofemoral DVT (OR=2.13, 95% CI: 1.19-3.07; P=0.041), and thrombus extension to the IVC (OR=2.95, 95% CI: 1.43-4.47; P=0.009) served as independent predictors for silent PE. Conclusion: A high incidence of silent PE was observed in patients with lower-extremity DVT. Screening of patients with DVT who have the aforementioned predictive risk factors using CTPA for silent PE may be needed and justified for the efficient management of VTE and its long-term complications.

15.
Vasc Specialist Int ; 39: 14, 2023 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-37334473

RESUMO

Von Gierke disease, also known as glycogen storage disease type I, co-existent with an abdominal aortic aneurysm (AAA), is an extremely rare combination of diseases that requires challenging therapeutic measures. We present, for the first time in literature, the case of a 62-year-old female with von Gierke disease who required open surgical repair of an AAA with challenging neck anatomy outside of instructions for use of endovascular repair. Even though the surgical risks for life-threatening complications, such as pancreatitis, metabolic acidosis, and kidney failure, were high, the 6-month postoperative course was uneventful. Despite the invasiveness of the treatment, surgery to treat the AAA was safe and effective. Further data is needed to draw robust conclusions about the treatment of choice for those patients with diseases in co-existence with AAAs.

16.
J Clin Med ; 12(8)2023 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-37109133

RESUMO

BACKGROUND: Treatment of calcified popliteal artery lesions represents an ongoing challenge for vascular specialists. Biomechanical forces of external compression, torsion and elongation that occur with locomotion in the popliteal segment can lead to stent fractures and occlusions. The aim of our study was to assess the procedural success rate of atherectomy in combination with balloon angioplasty for isolated calcified popliteal artery lesions. METHODS: Between January 2020 and December 2022, 62 patients with isolated atherosclerotic lesions of the popliteal artery underwent endovascular treatment by use of rotational atherectomy (Phoenix, Philips USA, (subgroup A) or Jetstream, Boston USA, (subgroup B), atherectomy systems) and additional balloon angioplasty in two vascular centers. The primary outcome measures were: 1. periprocedural clinical and technical success (<30% residual stenosis and no need for bailout stenting due to flow-limiting dissection) and 2. postprocedural increase in the ankle brachial index of more than 0.1. RESULTS: The overall rate of bailout stenting was 4.8%, whereas the procedural success rate was 98.4%. The rate of procedural complications included 3.7% and 5.7% peripheral embolizations in the subgroups A and B, respectively, and no vessel perforations were noted. All embolizations were successfully treated by catheter aspiration or capture in the pre-treatment placed filter system. In addition, 1 (3.7%) pseudoaneurysm in the groin was reported in subgroup A and treated by surgical means. Median ABI of the affected limbs improved from 0.55 (0.2) to 0.70 (0.2) in subgroup A and from 0.50 (0.2) to 0.95 (0.1) in subgroup B (DABI of 0.15 versus 0.45, p < 0.001). CONCLUSIONS: The combination of rotational atherectomy and balloon angioplasty in the popliteal artery showed reproducible outcomes in 2 centers, with low incidence of complications and low rates of bail-out stenting. These findings may contribute to more liberal use of such devices especially in segments with high risk for stent factures and occlusions.

17.
Vasc Specialist Int ; 39: 39, 2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38044693

RESUMO

Endovascular aortic aneurysm sealing (EVAS) with the Nellix endograft was initially considered a groundbreaking and acceptable alternative to conventional endovascular aortic aneurysm repair, with encouraging initial results. However, long-term follow-up has revealed a high incidence of endograft-related complications, such as caudal migration and type Ia endoleaks, indicating the need for reintervention. Managing failed EVAS remains challenging and is an ongoing topic of discussion, especially for high-risk patients. We describe a 70-year-old female who initially underwent EVAS with a Nellix endograft and presented after 5 years of follow-up with caudal endograft migration and a type Ia endoleak. The patient was treated with endovascular implantation of an Altura stent-graft, a relatively new low-profile device with a similar double stent configuration. Device migration and endoleaks were undetectable at 12 months of follow-up, suggesting that the Altura might offer a safe and efficient approach in cases of Nellix proximal failure.

18.
J Cardiovasc Surg (Torino) ; 63(1): 20-24, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34792313

RESUMO

INTRODUCTION: The aim of this paper was to evaluate the current role of atherectomy techniques (ATH) in treatment of peripheral arterial disease (PAD) at below the knee (BTK) arteries. EVIDENCE ACQUISITION: The PubMed and Embase were searched (last search on 11 September 2021) for studies reporting on the early and mid-term outcomes of ATH in BTK vessels. Analysis included the data from six studies, with a total of 1062 PAD patients treated with various ATH techniques. We compared them the ATH outcomes with the contemporaneous outcomes of plain balloon angioplasty alone or with bailout stenting. Early safety and efficacy were accessed with perioperative and 30-day technical success (TS) rate, which included the primary patency of the treated BTK arterial segment. Evaluation of clinical performance was based on target limb revascularization (TLR) and on major limb adverse events (MALEs) rates. EVIDENCE SYNTHESIS: The current body of literature mainly includes retrospective observational studies, and the level of derived evidence is low. The mean perioperative and 30-day TS rate was 87.3%. The mean reported TLR and MALEs rates at 12 months were 6.6% and 4.7% respectively. The relevant rates in studies reporting at 24 months were 24.3% and 31.7% while in studies reporting at 36 months the rates were 37.0% and 23.0% respectively. CONCLUSIONS: Based in low-quality evidence, it seems that ATH in BTK vessels has a high safety, high efficacy profile and durable outcomes at 12 months. In the mid-term, the clinical success of ATH is compromised by increased TLR and MALEs rates. Comparison of ATH with other endovascular techniques in BTK treatment of PAD shows a slight lead of ATH at 1-year and equivalent clinical performance in the mid-term. Overall, ATH has a significant and potentially predominant role in treatment of BTK vessels.


Assuntos
Artérias , Aterectomia , Perna (Membro)/irrigação sanguínea , Doença Arterial Periférica/terapia , Artérias/diagnóstico por imagem , Artérias/fisiopatologia , Aterectomia/efeitos adversos , Humanos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
19.
Int Urol Nephrol ; 54(7): 1551-1563, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34811606

RESUMO

The coronavirus disease 2019 (COVID-19) is associated with increased mortality in patients with chronic kidney disease (CKD), dialysis patients and kidney transplant recipients (KTR). Cardiovascular complications, such as sudden arrhythmias, thromboembolic events, coronary events, cardiomyopathies and heart failure, may present in about 10-20% of patients with COVID-19. Patients with CKD, dialysis patients and KTR are all at increased cardiovascular risk and present with more cardiovascular complications after COVID-19 compared to the general population. During the pandemic, health care giving has rapidly changed by reducing elective outpatient reviews, which may refrain these high-risk patients from the appropriate management of their medical conditions, further increasing cardiovascular risk. Importantly, acute kidney injury (AKI) is another common complication of severe COVID-19 and associates with increased mortality. A large proportion of the AKI patients need renal replacement treatment, while 30% of them may not present renal function recovery and remain dialysis-dependent after discharge, thereby having potentially increased future cardiovascular risk. This review summarizes current knowledge regarding the cardiovascular events and mortality in patients with CKD or undergoing hemodialysis and in KTR.


Assuntos
Injúria Renal Aguda , COVID-19 , Transplante de Rim , Insuficiência Renal Crônica , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/terapia , COVID-19/complicações , COVID-19/epidemiologia , Humanos , Diálise Renal , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/terapia , Fatores de Risco
20.
Vasc Specialist Int ; 38: 13, 2022 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-35712874

RESUMO

Renal artery aneurysms (RAAs) are rare lesions with a prevalence of less than 1% in the general population. Renal arteriovenous malformations (AVMs) are rare lesions with an estimated incidence of less than 0.04%. The coexistence of these two clinical entities is extremely rare and narrows the available treatment options by endovascular or open surgery. We describe a case of a giant symptomatic RAA type III, which was combined with a high-flow renal AVM in the right kidney. Using two vascular plugs, the RAA was excluded successfully. The perfusion of the right kidney's lower pole was preserved by implantation of two covered stents in the inferior segmental renal artery.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA