Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Heart Rhythm ; 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38762820

RESUMO

BACKGROUND: Implantable cardioverter-defibrillators last longer, and interest in reliable leads with targeted lead placement is growing. The OmniaSecure™ defibrillation lead is a novel small-diameter, catheter-delivered lead designed for targeted placement, based on the established SelectSecure SureScan MRI Model 3830 lumenless pacing lead platform. OBJECTIVE: This trial assessed safety and efficacy of the OmniaSecure defibrillation lead. METHODS: The worldwide LEADR pivotal clinical trial enrolled patients indicated for de novo implantation of a primary or secondary prevention implantable cardioverter-defibrillator/cardiac resynchronization therapy defibrillator, all of whom received the study lead. The primary efficacy end point was successful defibrillation at implantation per protocol. The primary safety end point was freedom from study lead-related major complications at 6 months. The primary efficacy and safety objectives were met if the lower bound of the 2-sided 95% credible interval was >88% and >90%, respectively. RESULTS: In total, 643 patients successfully received the study lead, and 505 patients have completed 12-month follow-up. The lead was placed in the desired right ventricular location in 99.5% of patients. Defibrillation testing at implantation was completed in 119 patients, with success in 97.5%. The Kaplan-Meier estimated freedom from study lead-related major complications was 97.1% at 6 and 12 months. The trial exceeded the primary efficacy and safety objective thresholds. There were zero study lead fractures and electrical performance was stable throughout the mean follow-up of 12.7 ± 4.8 months (mean ± SD). CONCLUSION: The OmniaSecure lead exceeded prespecified primary end point performance goals for safety and efficacy, demonstrating high defibrillation success and a low occurrence of lead-related major complications with zero lead fractures.

2.
Stud Health Technol Inform ; 220: 193-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27046577

RESUMO

Sensor enabled simulators may help in training and assessing clinical skill. Their are imitations on the locations current sensors can be placed without interfering with the clinical examination. In this study novel fabric force sensors were developed and tested. These sensors are soft and flexible and undetectable when placed in different locations in the simulator. Five sensors were added to our current sensor enabled breast simulator. Eight participants performed the clinical breast examination on the simulator and documented their findings. There was a significant relationship for both clinical breast examination time (r(6) = 0.99, p < 0.001) and average force (r(6) = 0.92, p < 0.005) between our current sensors and the new fabric sensors. In addition the senors were not noticed by the participants. These new sensors provide new methods to measure and assess clinical skill and performance.


Assuntos
Neoplasias da Mama/diagnóstico , Treinamento com Simulação de Alta Fidelidade/métodos , Palpação/instrumentação , Tato , Transdutores de Pressão , Competência Clínica , Vestuário , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Palpação/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA