Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Neth Heart J ; 32(3): 130-139, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38214880

RESUMO

AIM: To evaluate changes in healthcare utilisation and comprehensive packages of care activities and procedures (referred in the Netherlands to as 'diagnose-behandelcombinatie (DBC) care products) during the implementation of the TeleCheck-AF approach (teleconsultation supported by app-based heart rate/rhythm monitoring) in a Dutch atrial fibrillation (AF) clinic. METHODS AND RESULTS: In the Maastricht University Medical Centre+ AF Clinic, data on healthcare utilisation and DBC care products for patients consulted by both a conventional approach in 2019 and the TeleCheck-AF approach in 2020 were analysed. A patient experience survey was performed. Thirty-seven patients (median age 68 years; 40% women) were analysed. With the conventional approach, 35 face-to-face consultations and 0 teleconsultations were conducted. After the implementation of TeleCheck-AF, the number of face-to-face consultations dropped by 80% (p < 0.001) and teleconsultations increased to 45 (p < 0.001). While 42 electrocardiograms (ECGs) and 25 Holter ECGs or echocardiograms were recorded when using the conventional approach, the number of ECGs decreased by 71% (p < 0.001) and Holter ECGs or echocardiograms by 72% (p < 0.001) with the TeleCheck-AF approach. The emergency department patient presentations showed no statistically significant change (p = 0.33). Overall, 57% of medium-weight DBC care products were changed to light-weight ones during implementation of the TeleCheck-AF approach. Patient satisfaction with the TeleCheck-AF approach was high. CONCLUSION: The implementation of TeleCheck-AF led to a change in healthcare utilisation, a change from medium-weight to light-weight DBC care products and a reduction in patient burden. These results created the basis for a new reimbursement code for the TeleCheck-AF approach in the Netherlands.

2.
Europace ; 25(3): 835-844, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36748247

RESUMO

AIMS: Although mobile health tools using photoplethysmography (PPG) technology have been validated for the detection of atrial fibrillation (AF), their utility for heart rate assessment during AF remains unclear. Therefore, we aimed to evaluate the accuracy of continuous PPG-based 1 min mean heart rate assessment during AF. METHODS AND RESULTS: Persistent AF patients were provided with Holter electrocardiography (ECG) (for ≥24 h) simultaneously with a PPG-equipped smartwatch. Both the PPG-based smartwatch and Holter ECG automatically and continuously monitored patients' heart rate/rhythm. ECG and PPG recordings were synchronized and divided into 1 min segments, from which a PPG-based and an ECG-based average heart rate estimation were extracted. In total, 47 661 simultaneous ECG and PPG 1 min heart rate segments were analysed in 50 patients (34% women, age 73 ± 8 years). The agreement between ECG-determined and PPG-determined 1 min mean heart rate was high [root mean squared error (RMSE): 4.7 bpm]. The 1 min mean heart rate estimated using PPG was accurate within ±10% in 93.7% of the corresponding ECG-derived 1 min mean heart rate segments. PPG-based 1 min mean heart rate estimation was more often accurate during night-time (97%) than day-time (91%, P < 0.001) and during low levels (96%) compared to high levels of motion (92%, P < 0.001). A neural network with a 10 min history of the recording did not further improve the PPG-based 1 min mean heart rate assessment [RMSE: 4.4 (95% confidence interval: 3.5-5.2 bpm)]. Only chronic heart failure was associated with a lower agreement between ECG-derived and PPG-derived 1 min mean heart rates (P = 0.040). CONCLUSION: During persistent AF, continuous PPG-based 1 min mean heart rate assessment is feasible in 60% of the analysed period and shows high accuracy compared with Holter ECG for heart rates <110 bpm.


Assuntos
Fibrilação Atrial , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Fibrilação Atrial/diagnóstico , Frequência Cardíaca , Fotopletismografia/métodos , Eletrocardiografia/métodos , Eletrocardiografia Ambulatorial , Algoritmos
3.
N Engl J Med ; 380(16): 1499-1508, 2019 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-30883054

RESUMO

BACKGROUND: Patients with recent-onset atrial fibrillation commonly undergo immediate restoration of sinus rhythm by pharmacologic or electrical cardioversion. However, whether immediate restoration of sinus rhythm is necessary is not known, since atrial fibrillation often terminates spontaneously. METHODS: In a multicenter, randomized, open-label, noninferiority trial, we randomly assigned patients with hemodynamically stable, recent-onset (<36 hours), symptomatic atrial fibrillation in the emergency department to be treated with a wait-and-see approach (delayed-cardioversion group) or early cardioversion. The wait-and-see approach involved initial treatment with rate-control medication only and delayed cardioversion if the atrial fibrillation did not resolve within 48 hours. The primary end point was the presence of sinus rhythm at 4 weeks. Noninferiority would be shown if the lower limit of the 95% confidence interval for the between-group difference in the primary end point in percentage points was more than -10. RESULTS: The presence of sinus rhythm at 4 weeks occurred in 193 of 212 patients (91%) in the delayed-cardioversion group and in 202 of 215 (94%) in the early-cardioversion group (between-group difference, -2.9 percentage points; 95% confidence interval [CI], -8.2 to 2.2; P = 0.005 for noninferiority). In the delayed-cardioversion group, conversion to sinus rhythm within 48 hours occurred spontaneously in 150 of 218 patients (69%) and after delayed cardioversion in 61 patients (28%). In the early-cardioversion group, conversion to sinus rhythm occurred spontaneously before the initiation of cardioversion in 36 of 219 patients (16%) and after cardioversion in 171 patients (78%). Among the patients who completed remote monitoring during 4 weeks of follow-up, a recurrence of atrial fibrillation occurred in 49 of 164 patients (30%) in the delayed-cardioversion group and in 50 of 171 (29%) in the early-cardioversion group. Within 4 weeks after randomization, cardiovascular complications occurred in 10 patients and 8 patients, respectively. CONCLUSIONS: In patients presenting to the emergency department with recent-onset, symptomatic atrial fibrillation, a wait-and-see approach was noninferior to early cardioversion in achieving a return to sinus rhythm at 4 weeks. (Funded by the Netherlands Organization for Health Research and Development and others; RACE 7 ACWAS ClinicalTrials.gov number, NCT02248753.).


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/terapia , Cardioversão Elétrica , Tempo para o Tratamento , Antagonistas Adrenérgicos beta/uso terapêutico , Idoso , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Bloqueadores dos Canais de Cálcio/uso terapêutico , Digoxina/uso terapêutico , Cardioversão Elétrica/efeitos adversos , Serviço Hospitalar de Emergência , Feminino , Frequência Cardíaca , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Recidiva , Resultado do Tratamento
4.
Europace ; 24(3): 384-389, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-34414430

RESUMO

AIMS: We hypothesize that in patients with paroxysmal atrial fibrillation (AF), verapamil is associated with lower AF progression compared to beta blockers or no rate control. METHODS AND RESULTS: In this pre-specified post hoc analysis of the RACE 4 randomized trial, the effect of rate control medication on AF progression in paroxysmal AF was analysed. Patients using Vaughan-Williams Class I or III antiarrhythmic drugs were excluded. The primary outcome was a composite of first electrical cardioversion (ECV), chemical cardioversion (CCV), or atrial ablation. Event rates are displayed using Kaplan-Meier curves and multivariable Cox regression analyses are used to adjust for baseline differences. Out of 666 patients with paroxysmal AF, 47 used verapamil, 383 used beta blockers, and 236 did not use rate control drugs. The verapamil group was significantly younger than the beta blocker group and contained more men than the no rate control group. Over a mean follow-up of 37 months, the primary outcome occurred in 17% in the verapamil group, 33% in the beta blocker group, and 33% in the no rate control group (P = 0.038). After adjusting for baseline characteristics, patients using verapamil have a significantly lower chance of receiving ECV, CCV, or atrial ablation compared to patients using beta blockers [hazard ratio (HR) 0.40, 95% confidence interval (CI) 0.19-0.83] and no rate control (HR 0.64, 95% CI 0.44-0.93). CONCLUSION: In patients with newly diagnosed paroxysmal AF, verapamil was associated with less AF progression, as compared to beta blockers and no rate control.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Ablação por Cateter/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/métodos , Humanos , Masculino , Resultado do Tratamento
5.
Europace ; 24(4): 565-575, 2022 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-34718525

RESUMO

AIMS: In atrial fibrillation (AF) patients, untreated sleep-disordered breathing (SDB) is associated with lower success rates of rhythm control strategies and as such structured SDB testing is recommended. Herein, we describe the implementation of a virtual SDB management pathway in an AF outpatient clinic and examine the utility and feasibility of this new approach. METHODS AND RESULTS: Prospectively, consecutive AF patients accepted for AF catheter ablation procedures without previous diagnosis of SDB were digitally referred to a virtual SDB management pathway and instructed to use WatchPAT-ONE (ITAMAR) for one night. Results were automatically transferred to a virtual sleep laboratory, upon which a teleconsultation with a sleep physician was planned. Patient experience was measured using surveys. SDB testing was performed in 119 consecutive patients scheduled for AF catheter ablation procedures. The median time from digital referral to finalization of the sleep study report was 18 [11-24] days. In total, 65 patients (55%) were diagnosed with moderate-to-severe SDB. Patients with SDB were prescribed more cardiovascular drugs and had higher body mass indices (BMI, 29 ± 3.3 vs. 27 ± 4.4kg/m2, P < 0.01). Patients agreed that WatchPAT-ONE was easy to use (91%) and recommended future use of this virtual pathway in AF outpatient clinics (86%). Based on this remote SDB testing, SDB treatment was recommended in the majority of patients. CONCLUSION: This novel virtual AF management pathway allowed remote SDB testing in AF outpatient clinics with a short time to diagnosis and high patient satisfaction. Structured SDB testing results in a high detection of previously unknown SDB in AF patients scheduled for AF ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Síndromes da Apneia do Sono , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Humanos , Polissonografia , Sono , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/terapia
6.
Europace ; 23(3): 345-352, 2021 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-32887994

RESUMO

During the coronavirus 2019 (COVID-19) pandemic, outpatient visits in the atrial fibrillation (AF) clinic of the Maastricht University Medical Centre (MUMC+) were transferred into teleconsultations. The aim was to develop anon-demand app-based heart rate and rhythm monitoring infrastructure to allow appropriatmanagement of AF through teleconsultation. In line with the fundamental aspects of integrated care, including actively involving patients in the care process and providing comprehensive care by a multidisciplinary team, we implemented a mobile health (mHealth) intervention to support teleconsultations with AF patients: TeleCheck-AF. The TeleCheck-AF approach guarantees the continuity of comprehensive AF management and supports integrated care through teleconsultation during COVID-19. It incorporates three important components: (i) a structured teleconsultation ('Tele'), (ii) a CE-marked app-based on-demand heart rate and rhythm monitoring infrastructure ('Check'), and (iii) comprehensive AF management ('AF'). In this article, we describe the components and implementation of the TeleCheck-AF approach in an integrated and specialized AF-clinic through teleconsultation. The TeleCheck-AF approach is currently implemented in numerous European centres during COVID-19.


Assuntos
Fibrilação Atrial/diagnóstico , COVID-19 , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Aplicativos Móveis , Consulta Remota/instrumentação , Smartphone , Potenciais de Ação , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Prestação Integrada de Cuidados de Saúde , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
7.
Europace ; 23(7): 1003-1015, 2021 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-33822029

RESUMO

AIMS: TeleCheck-AF is a multicentre international project initiated to maintain care delivery for patients with atrial fibrillation (AF) during COVID-19 through teleconsultations supported by an on-demand photoplethysmography-based heart rate and rhythm monitoring app (FibriCheck®). We describe the characteristics, inclusion rates, and experiences from participating centres according the TeleCheck-AF infrastructure as well as characteristics and experiences from recruited patients. METHODS AND RESULTS: Three surveys exploring centre characteristics (n = 25), centre experiences (n = 23), and patient experiences (n = 826) were completed. Self-reported patient characteristics were obtained from the app. Most centres were academic (64%) and specialized public cardiology/district hospitals (36%). Majority of the centres had AF outpatient clinics (64%) and only 36% had AF ablation clinics. The time required to start patient inclusion and total number of included patients in the project was comparable for centres experienced (56%) or inexperienced in mHealth use. Within 28 weeks, 1930 AF patients were recruited, mainly for remote AF control (31% of patients) and AF ablation follow-up (42%). Average inclusion rate was highest during the lockdown restrictions and reached a steady state at a lower level after easing the restrictions (188 vs. 52 weekly recruited patients). Majority (>80%) of the centres reported no problems during the implementation of the TeleCheck-AF approach. Recruited patients [median age 64 (55-71), 62% male] agreed that the FibriCheck® app was easy to use (94%). CONCLUSION: Despite different health care settings and mobile health experiences, the TeleCheck-AF approach could be set up within an extremely short time and easily used in different European centres during COVID-19.


Assuntos
Fibrilação Atrial , COVID-19 , Aplicativos Móveis , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Controle de Doenças Transmissíveis , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias , Avaliação de Resultados da Assistência ao Paciente , SARS-CoV-2
8.
Cardiology ; 146(3): 392-396, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33735889

RESUMO

Recently, we introduced the TeleCheck-AF approach, an on-demand mobile health (mHealth) infrastructure using app-based heart rate and rhythm monitoring for 7 days, to support long-term atrial fibrillation (AF) management through teleconsultation. Herein, we extend the mHealth approach to patients with recent-onset AF at the emergency department (ED). In the proposed TeleWAS-AF approach, on-demand heart rate and rhythm monitoring are used to support a wait-and-see strategy at the ED. All stable patients who present to the ED with recent-onset symptomatic AF and who are able to use mHealth solutions for heart rate and rhythm monitoring are eligible for this approach. Patients will receive both education on AF and instructions on the use of the mHealth technology before discharge from the ED. A case coordinator will subsequently check whether patients are able to activate the mHealth solution and to perform heart rate and rhythm measurements. Forty hours after AF onset, the first assessment teleconsultation with the physician will take place, determining the need for delayed cardioversion. After maximal 7 days of remote monitoring, a second assessment teleconsultation may occur, in which the rhythm can be reassessed and further treatment strategy can be discussed with the patients. This on-demand mHealth prescription increases patient involvement in the care process and treatment decision-making by encouraging self-management, while avoiding excess data-load requiring work-intensive and expensive data management. Implementation of the TeleWAS-AF approach may facilitate the management of AF in the ED and reduce the burden on the ED system, which enhances the capacity for health care utilization.


Assuntos
Fibrilação Atrial , Telemedicina , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/terapia , Cardioversão Elétrica , Serviço Hospitalar de Emergência , Frequência Cardíaca , Humanos
9.
Eur Heart J ; 41(5): 634-641, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31544925

RESUMO

BACKGROUND: Nurse-led integrated care is expected to improve outcome of patients with atrial fibrillation compared with usual-care provided by a medical specialist. METHODS AND RESULTS: We randomized 1375 patients with atrial fibrillation (64 ± 10 years, 44% women, 57% had CHA2DS2-VASc ≥ 2) to receive nurse-led care or usual-care. Nurse-led care was provided by specialized nurses using a decision-support tool, in consultation with the cardiologist. The primary endpoint was a composite of cardiovascular death and cardiovascular hospital admissions. Of 671 nurse-led care patients, 543 (81%) received anticoagulation in full accordance with the guidelines against 559 of 683 (82%) usual-care patients. The cumulative adherence to guidelines-based recommendations was 61% under nurse-led care and 26% under usual-care. Over 37 months of follow-up, the primary endpoint occurred in 164 of 671 patients (9.7% per year) under nurse-led care and in 192 of 683 patients (11.6% per year) under usual-care [hazard ratio (HR) 0.85, 95% confidence interval (CI) 0.69 to 1.04, P = 0.12]. There were 124 vs. 161 hospitalizations for arrhythmia events (7.0% and 9.4% per year), and 14 vs. 22 for heart failure (0.7% and 1.1% per year), respectively. Results were not consistent in a pre-specified subgroup analysis by centre experience, with a HR of 0.52 (95% CI 0.37-to 0.71) in four experienced centres and of 1.24 (95% CI 0.94-1.63) in four less experienced centres (P for interaction <0.001). CONCLUSION: Our trial failed to show that nurse-led care was superior to usual-care. The data suggest that nurse-led care by an experienced team could be clinically beneficial (ClinicalTrials.gov NCT01740037). TRIAL REGISTRATION NUMBER: ClinicalTrials.gov (NCT01740037).


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Acidente Vascular Cerebral , Idoso , Anticoagulantes/uso terapêutico , Fibrilação Atrial/terapia , Feminino , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Papel do Profissional de Enfermagem , Modelos de Riscos Proporcionais
10.
Pacing Clin Electrophysiol ; 41(10): 1336-1340, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30080928

RESUMO

BACKGROUND: Atrial tachyarrhythmias are common in patients with cardiac implantable electronic devices (CIEDs). Restoration of sinus rhythm by external electrical cardioversion (eECV) is frequently used to alleviate symptoms and to ensure optimal device function. OBJECTIVES: To evaluate the safety of eECV in patients with contemporary CIEDs and to assess the need for immediate device interrogation after eECV. METHODS: We conducted a retrospective observational study of 229 patients (27.9% female, age 69 ± 10 years) with a CIED (104 pacemakers, 69 implantable cardioverter defibrillators, and 56 biventricular devices) who underwent eECV between 2008 and 2016 in two centers. Data from device interrogation before eECV, immediately afterwards, and at first follow-up (FU) after eECV were collected. CIED-related complications and adverse events during and after eECV were recorded. RESULTS: No significant differences between right atrial (RA) and right ventricular (RV) sensing or threshold values before eECV, immediately afterwards, or at FU were observed. A small yet significant decrease was observed in RA and RV impedance immediately after eECV (484 Ω vs 462 Ω, P < 0.001 and 536 Ω vs 514 Ω, P < 0.001, respectively). The RV impedance did not recover to the baseline value (538 Ω vs 527 Ω, P  =  0.02). The impedance changes were without clinical consequences. No changes in left ventricular lead threshold or impedance values were measured. No CIED-related complications or adverse events were documented following eECV. CONCLUSION: eECV in patients with contemporary CIEDs is safe. There seems to be no need for immediate device interrogation after eECV.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Cardioversão Elétrica/métodos , Marca-Passo Artificial , Segurança do Paciente , Idoso , Feminino , Humanos , Masculino , Países Baixos , Estudos Retrospectivos
15.
Med Sci Sports Exerc ; 56(8): 1349-1354, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38597869

RESUMO

INTRODUCTION: Long-term endurance exercise is suspect to elevate the risk of atrial fibrillation (AF), but little is known about cardiovascular outcome and disease progression in this subgroup of AF patients. We investigated whether previous exercise level determines cardiovascular outcome. METHODS: In this post hoc analysis of the RACE 4 randomized trial, we analyzed all patients with a completed questionnaire on sports participation. Three subgroups were made based on lifetime sports hours up to randomization and previous compliance to the international physical activity guidelines. High lifetime hours of high dynamic activity patients were defined as more than 150 min·wk -1 of high-intensity physical exercise. The primary endpoint was a composite of cardiovascular death and hospital admissions. RESULTS: A total of 879 patients were analyzed, divided in 203 high lifetime hours of high dynamic activity, 192 high lifetime hours of activity, and 484 low lifetime hours of activity patients. Over a mean follow-up of 36 months (±14), the primary endpoint occurred in 61 out of 203 (30%) high lifetime hours of high dynamic activity, 53 out of 192 (27%) high lifetime hours of activity, and 135 out of 484 (28%) low lifetime hours of activity patients ( P = 0.74). During follow-up, 42 high lifetime hours of high dynamic activity (35%), 43 high lifetime hours of activity (32%), and 104 low lifetime hours of activity patients (34%) with paroxysmal AF received electrical or chemical cardioversion or atrial ablation ( P = 0.90). CONCLUSIONS: In patients included in the RACE 4, there seems to be no relation between previous activity levels and cardiovascular outcome and the need for electrical or chemical cardioversion or atrial ablation. Cardiovascular outcome was driven by AF-related arrhythmic events.


Assuntos
Fibrilação Atrial , Exercício Físico , Humanos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Hospitalização/estatística & dados numéricos , Progressão da Doença
16.
Clin Cardiol ; 47(1): e24161, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37872853

RESUMO

BACKGROUND: In the Rate Control versus Electrical Cardioversion Trial 7-Acute Cardioversion versus Wait and See, patients with recent-onset atrial fibrillation (AF) were randomized to either early or delayed cardioversion. AIM: This prespecified sub-analysis aimed to evaluate heart rate during AF recurrences after an emergency department (ED) visit identified by an electrocardiogram (ECG)-based handheld device. METHODS: After the ED visit, included patients (n = 437) were asked to use an ECG-based handheld device to monitor for recurrences during the 4-week follow-up period. 335 patients used the handheld device and were included in this analysis. Recordings from the device were collected and assessed for heart rhythm and rate. Optimal rate control was defined as a target resting heart rate of <110 beats per minute (bpm). RESULTS: In 99 patients (29.6%, mean age 67 ± 10 years, 39.4% female, median 6 [3-12] AF recordings) a total of 314 AF recurrences (median 2 [1-3] per patient) were identified during follow-up. The average median resting heart rate at recurrence was 100 ± 21 bpm in the delayed vs 112 ± 25 bpm in the early cardioversion group (p = .011). Optimal rate control was seen in 68.4% [21.3%-100%] and 33.3% [0%-77.5%] of recordings (p = .01), respectively. Randomization group [coefficient -12.09 (-20.55 to -3.63, p = .006) for delayed vs. early cardioversion] and heart rate on index ECG [coefficient 0.46 (0.29-0.63, p < .001) per bpm increase] were identified on multivariable analysis as factors associated with lower median heart rate during AF recurrences. CONCLUSION: A delayed cardioversion strategy translated into a favorable heart rate profile during AF recurrences.


Assuntos
Fibrilação Atrial , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Cardioversão Elétrica , Eletrocardiografia , Frequência Cardíaca , Recidiva , Ensaios Clínicos Controlados Aleatórios como Assunto
17.
Clin Res Cardiol ; 112(6): 834-845, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36773038

RESUMO

BACKGROUND: Sleep-disordered breathing (SDB) is prevalent in up to 50% of patients referred for atrial fibrillation (AF) catheter ablation (CA). Currently, it remains unclear how to improve pre-selection for SDB screening in patients with AF. AIM: We aimed to (1) assess the accuracy of the STOP-Bang screening questionnaire for detection of SDB within an AF population referred for CA; (2) derive a refined, AF-specific SDB score to improve pre-selection. METHODS: Consecutive AF patients referred for CA without a history of SDB and/or SDB screening were included. Patients were digitally referred to the previously implemented Virtual-SAFARI SDB screening and management pathway including a home sleep test. An apnoea-hypopnoea index (AHI) of  ≥ 15 was interpreted as moderate-to-severe SDB. Logistic regression analysis was used to assess characteristics associated with moderate-to-severe SDB to refine pre-selection for SDB screening. RESULTS: Of 206 included patients, 51% were diagnosed with moderate-to-severe SDB. The STOP-Bang questionnaire performed poorly in detecting SDB, with an area under the receiver operating characteristic curve (AUROC) of 0.647 (95% Confidence-Interval (CI) 0.573-0.721). AF-specific refinement resulted in the BOSS-GAP score. Therein, BMI with cut-off point ≥ 27 kg/m2 and previous stroke or transient ischaemic attack (TIA) were added, while tiredness and neck circumference were removed. The BOSS-GAP score performed better with an AUROC of 0.738 (95% CI 0.672-0.805) in the overall population. CONCLUSION: AF-specific refinement of the STOP-Bang questionnaire moderately improved detection of SDB in AF patients referred for CA. Whether questionnaires bring benefits for pre-selection of SDB compared to structural screening in patients with AF requires further studies. TRIAL REGISTRATION NUMBER: ISOLATION was registered NCT04342312, 13-04-2020.


Assuntos
Fibrilação Atrial , Síndromes da Apneia do Sono , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/epidemiologia , Inquéritos e Questionários , Polissonografia/métodos , Curva ROC
18.
Int J Cardiol Heart Vasc ; 42: 101086, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35873859

RESUMO

Atrial fibrillation (AF) is the most common sustained heart rhythm disorder and is often associated with symptoms that can significantly impact quality of life and daily functioning. Palpitations are the cardinal symptom of AF and many AF therapies are targeted towards relieving this symptom. However, up to two-third of patients also complain of dyspnea as a predominant self-reported symptom. In clinical practice it is often challenging to ascertain whether dyspnea represents an AF-related symptom or a symptom of concomitant cardiovascular and non-cardiovascular comorbidities, since common AF comorbidities such as heart failure and chronic obstructive pulmonary disease share similar symptoms. In addition, therapeutic approaches specifically targeting dyspnea have not been well validated. Thus, assessing and treating dyspnea can be difficult. This review describes the latest knowledge on the burden and pathophysiology of dyspnea in AF patients. We discuss the role of heart rhythm control interventions as well as the management of AF risk factors and comorbidities with the goal to achieve maximal relief of dyspnea. Given the different and often complex mechanistic pathways leading to dyspnea, dyspneic AF patients will likely profit from an integrated multidisciplinary approach to tackle all factors and mechanisms involved. Therefore, we propose an interdisciplinary and integrated care pathway for the work-up of dyspnea in AF patients.

19.
Clin Res Cardiol ; 111(5): 479-491, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34549333

RESUMO

AIM: We aimed to systematically review the available literature on mobile Health (mHealth) solutions, including handheld and wearable devices, implantable loop recorders (ILRs), as well as mobile platforms and support systems in atrial fibrillation (AF) detection and management. METHODS: This systematic review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. The electronic databases PubMed (NCBI), Embase (Ovid), and Cochrane were searched for articles published until 10 February 2021, inclusive. Given that the included studies varied widely in their design, interventions, comparators, and outcomes, no synthesis was undertaken, and we undertook a narrative review. RESULTS: We found 208 studies, which were deemed potentially relevant. Of these studies included, 82, 46, and 49 studies aimed at validating handheld devices, wearables, and ILRs for AF detection and/or management, respectively, while 34 studies assessed mobile platforms/support systems. The diagnostic accuracy of mHealth solutions differs with respect to the type (handheld devices vs wearables vs ILRs) and technology used (electrocardiography vs photoplethysmography), as well as application setting (intermittent vs continuous, spot vs longitudinal assessment), and study population. CONCLUSION: While the use of mHealth solutions in the detection and management of AF is becoming increasingly popular, its clinical implications merit further investigation and several barriers to widespread mHealth adaption in healthcare systems need to be overcome. Mobile health solutions for atrial fibrillation detection and management: a systematic review.


Assuntos
Fibrilação Atrial , Telemedicina , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Eletrocardiografia , Humanos
20.
Int J Cardiol ; 367: 29-37, 2022 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-35963443

RESUMO

BACKGROUND: The assessment of symptom-rhythm correlation (SRC) in patients with persistent atrial fibrillation (AF) is challenging. Therefore, we performed a novel mobile app-based approach to assess SRC in persistent AF. METHODS: Consecutive persistent AF patients planned for electrical cardioversion (ECV) used a mobile app to record a 60-s photoplethysmogram (PPG) and report symptoms once daily and in case of symptoms for four weeks prior and three weeks after ECV. Within each patient, SRC was quantified by the SRC-index defined as the sum of symptomatic AF recordings and asymptomatic non-AF recordings divided by the sum of all recordings. RESULTS: Of 88 patients (33% women, age 68 ± 9 years) included, 78% reported any symptoms during recordings. The overall SRC-index was 0.61 (0.44-0.79). The study population was divided into SRC-index tertiles: low (<0.47), medium (0.47-0.73) and high (≥0.73). Patients within the low (vs high) SRC-index tertile had more often heart failure and diabetes mellitus (both 24.1% vs 6.9%). Extrasystoles occurred in 19% of all symptomatic non-AF PPG recordings. Within each patient, PPG recordings with the highest (vs lowest) tertile of pulse rates conferred an increased risk for symptomatic AF recordings (odds ratio [OR] 1.26, 95% coincidence interval [CI] 1.04-1.52) and symptomatic non-AF recordings (OR 2.93, 95% CI 2.16-3.97). Pulse variability was not associated with reported symptoms. CONCLUSIONS: In patients with persistent AF, SRC is relatively low. Pulse rate is the main determinant of reported symptoms. Further studies are required to verify whether integrating mobile app-based SRC assessment in current workflows can improve AF management.


Assuntos
Fibrilação Atrial , Aplicativos Móveis , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Cardioversão Elétrica , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA