1.
Opt Express ; 25(13): 14504-14515, 2017 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-28789036

RESUMO

Mid-infrared spectroscopy is an essential analytical method in science and industry. Unlike in the near-infrared range, grating spectrometers for the mid-infrared are rarely employed, mostly due to the limited availability and performance of suitable line array detectors. In this work, continuous-wave nonlinear-optical upconversion is used to enable mid-infrared spectroscopy. A broad spectral window between 3.7 and 4.7 µm is upconverted to 825 - 867 nm for detection on a silicon-camera-based near-infrared grating spectrometer with a high sensitivity down to sub-picowatt of input power. A theoretical model is presented that accurately describes the upconversion process and the total system behavior. Spectroscopic flame emission measurements demonstrate the applicability towards the analysis of highly dynamic processes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA