Rev Cardiovasc Med ; 24(5): 128, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-39076731

RESUMO

Pharmacological treatment is the cornerstone therapy of heart failure with reduced ejection fraction (HFrEF). In addition, several percutaneous techniques have been developed to treat symptomatic patients, with specific heart failure (HF) phenotypes (e.g., valvular heart disease) that require non-pharmacological treatment. Given their prognostic relevance, it is imperative to deliver high-level patient care. This review provides a clinical overview on the available data regarding transcatheter devices in the armamentarium of contemporary interventional cardiologists, focusing on the clinical and anatomical selection criteria.

2.
Catheter Cardiovasc Interv ; 102(2): 310-317, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37232290

RESUMO

BACKGROUND: The relationship between high postprocedural mean gradient (ppMG) and clinical events following mitral valve transcatheter edge-to-edge repair (MV-TEER) in patients with degenerative mitral regurgitation (DMR) is still debated. AIM: The purpose of this study was to evaluate the effect of elevated ppMG after MV-TEER on clinical events in patients with DMR at 1-year follow-up. METHODS: The study included 371 patients with DMR treated with MV-TEER enrolled in the "Multi-center Italian Society of Interventional Cardiology (GISE) registry of trans-catheter treatment of mitral valve regurgitation" (GIOTTO) registry. Patients were stratified in tertiles according to ppMG. Primary endpoint was a composite of all-cause death and hospitalization due to heart failure at 1-year follow-up. RESULTS: Patients were stratified as follows: 187 with a ppMG ≤ 3 mmHg, 77 with a ppMG > 3/=4 mmHg, and 107 with a ppMG > 4 mmHg. Clinical follow-up was available in all subjects. At multivariate analysis, neither a ppMG > 4 mmHg nor a ppMG ≥ 5 mmHg were independently associated with the outcome. Notably, the risk of elevated residual MR (rMR > 2+) was significantly higher in patients belonging to the highest tertile of ppMG (p = 0.009). The association of ppMG > 4 mmHg and rMR ≥ 2+ was strongly and independently associated with adverse events (hazard ratio: 1.98; 95% confidence interval: [1.10-3.58]). CONCLUSIONS: In a real-world cohort of patients suffering DMR and treated with MV-TEER, isolated ppMG was not associated with the outcome at 1-year follow-up. A high proportion of patients showed both elevated ppMG and rMR and their combination appeared to be a strong predictor of adverse events.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos
3.
Artigo em Inglês | MEDLINE | ID: mdl-36525378

RESUMO

OBJECTIVES: To explore the long-term clinical outcomes following intravascular lithotripsy (IVL) in calcified coronary lesions from a real-world population. BACKGROUND: IVL is a relatively new but promising modality for treating coronary calcified lesions, but there is a dearth of long-term outcome data from real-world patients. METHODS: This was a multicenter, observational study in which we enrolled all patients treated with IVL from November 2018 to February 2021 from eight centers in Europe and the United Kingdom. Procedural success, complications, and clinical outcomes (cardiac death, target vessel myocardial infarction [TVMI], target lesion revascularization [TLR], and MACE [major adverse cardiac events, the composite of cardiac death, TVMI, and TLR]) were assessed. RESULTS: In total, 273 patients with a mean age of 72 ± 9.1 years were treated with IVL. Major comorbidities included diabetes mellitus (n = 110, 40%) and chronic kidney disease (n = 45, 16%). Acute coronary syndrome accounted for 48% (n = 132) of patients, while 52% (n = 141) had stable angina. De novo lesions and in-stent restenosis accounted for 79% and 21% of cases, respectively. Intravascular imaging was used in 33% (n = 90) of patients. An upfront IVL strategy was adopted in 34% (n = 92), while the rest were bailout procedures. Adjuvant rotational atherectomy ("RotaTripsy") was required in 11% (n = 31) of cases. The procedural success was 99%. During a median follow-up of 687 days (interquartile range: 549-787), cardiac death occurred in 5% (n = 14), TVMI in 3% (n = 8), TLR in 6% (n = 16), and MACE rate was 11% (n = 30). CONCLUSION: This is the largest multicenter registry with a long-term follow-up showing the remarkably high procedural success of IVL use in calcified coronary lesions with low rates of hard endpoints and MACE.

5.
Catheter Cardiovasc Interv ; 99(4): 1277-1286, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34939726

RESUMO

OBJECTIVES: To evaluate the prognostic impact of baseline tricuspid annular plane systolic excursion/pulmonary artery systolic pressure (TAPSE/PASP) ratio, as an expression of the right ventricle-pulmonary artery (RV-PA) coupling, in patients with mitral regurgitation (MR) treated with the MitraClip. BACKGROUND: Impaired RV to PA coupling is considered a marker of RV dysfunction. METHODS: From February 2016 to February 2020, a total of 165 patients were evaluated and stratified in two groups according to a prespecified value of TAPSE/PASP ratio ≤ 0.36. RESULTS: The median patients' age was 79 (men: 62.4%). Sixty-three patients (38.1%) presented TAPSE/PASP ≤ 0.36 and were then compared with patients with TAPSE/PASP > 0.36. Functional MR etiology was more frequent in TAPSE/PASP ≤ 0.36 (71.4%; p = 0.046). Acute technical success was achieved in 92.7% of the population, without any significant difference between the two groups of study and with sustained results at 30-day (device success: 85.5%; procedural success: 84.8%). On multivariate Cox regression analysis, after correction for body mass index, chronic kidney disease and left ventricle ejection fraction ≥30% but <50%, TAPSE/PASP ≤ 0.36 remained a sustained predictor of mortality and hospitalization for heart failure at one year after MitraClip (hazard ratio: 3.87; 95% confidence interval: 1.83-8.22; p ≤ 0.001). Kaplan-Meier all-cause mortality and heart failure hospitalization rates at one year were consequently higher in patients with TAPSE/PASP ≤ 0.36 (39.4% vs. 14.8%; log-rank p ≤ 0.001). CONCLUSION: Baseline TAPSE/PASP ratio seems independently associated with all-cause mortality and heart failure hospitalization after MitraClip both in functional and degenerative MR.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Disfunção Ventricular Direita , Ventrículos do Coração , Humanos , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Prognóstico , Artéria Pulmonar/diagnóstico por imagem , Resultado do Tratamento , Função Ventricular Direita
6.
Catheter Cardiovasc Interv ; 98(6): E847-E854, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-33960624

RESUMO

AIMS: The aim of this proof-of-concept study was to investigate safety and efficacy of a CT-scan based patient-specific algorithm to maximize coronary clearance and secondarily to achieve anatomically correct commissural alignment with the Acurate Neo device. METHOD AND RESULTS: A total of 45 consecutive patients undergoing TAVR with the Acurate Neo THV were prospectively enrolled in the study. Mean age was 81.6 ± 5.5 years, mean STS score was 6.1 ± 3.7. Device success rate was 100%. Aim of the technique was to rotationally deploy the TAVR device with a commissure lying on the bisector between the coronary ostia as calculated on the pre-procedural CT-scan. At post-TAVR CT-scan, coronary clearance was achieved in 98% of patients with no cases of severe coronary artery overlap. In 42 out of 45 patients, THV was aligned or, at most, mildly misaligned; there were 2 cases of moderate misalignment without any case of severe misalignment. Post-TAVR selective coronary artery engagement was attempted and succeeded in all patients (100%). CONCLUSION: Our CT-scan based patient-specific algorithm is safe and proven to be effective in avoiding coronary artery overlap and providing commissural alignment with Acurate Neo in all treated patients.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 98(1): E145-E152, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33155757

RESUMO

OBJECTIVE: This study sought to investigate the procedural and mid-term outcomes of transcatheter aortic valve implantation for failed surgical bioprostheses (TAVI-ViV) with Portico device. BACKGROUND: Limited evidence coming from early experience on Portico system does not allow to fully assess safety and efficacy of this device in this ViV patients. METHODS: From January 2016 up to June 2019, 56 consecutive patients undergoing TAVI-ViV with Portico were prospectively included in our institutional TAVI database. RESULTS: The prevalent mechanism of failure was stenosis (58.9%); true internal diameter (ID) was <21 mm in 71.4% of cases. Device success rate were 69.6% with 14 (25%) patients showing a residual gradient ≥20 mmHg, 2 (3.6%) a PVL ≥ moderate and 1 (1.8%) required a second THV implantation due to device embolization. At 1-year follow-up 5 patients (8.9%) died whereas moderate SVD was reported in 2 (3.6%). Patients with a post-procedural mean gradient ≥20 mmHg showed a significantly higher rate of CV hospitalization (21.4% vs. 2.4%, p = .02) whereas no differences in procedural and 1-year outcomes were noticed according to true ID diameter or degeneration mode. Chimney stenting (ChT) was performed in 23 (41%) patients without significant differences in procedural and 1-year outcomes compared to non-ChT group. CONCLUSIONS: TAVI-ViV with Portico valve was associated with good procedural and 1-year outcomes, even in patients with features of high procedural and anatomical complexity.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 97(1): E135-E145, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32400068

RESUMO

OBJECTIVES: To investigate paravalvular leak (PVL) and devices success rates according to aortic angle (AA) in patients undergoing transcatheter aortic valve implantation (TAVI) with three new-generation self-expanding devices. BACKGROUND: The impact of aortic angle (AA) on TAVI device success and PVL rates is controversial. METHODS: This retrospective study included 392 patients submitted to TAVI for severe aortic stenosis with Portico, Evolut-R and Acurate-NEO, and available AA measurements at computed tomography (CT) angiography. AA was calculated from the implantation projection and was defined as the angle between the plane of aortic annulus and an ideal horizontal plane. Aorta was defined horizontal if AA>57° (75th percentile). RESULTS: In the horizontal group, the rates of moderate/severe PVL was higher in the Evolut-R group (20.8%), which was also characterized by a lower implant compared to that of Acurate-NEO, whereas device success was comparable among the three devices. AA was a significant predictor of moderate/severe PVLs (AUC 0.72, p = .002) only in the Evolut-R population. On multivariate analysis, calcium volume 850HU, bicuspid aortic valve, and implantation depth at the level of left coronary cusp were independent predictors of moderate/severe PVL. On univariate analysis in the horizontal aorta population, implantation depth was confirmed among the most significant predictors of moderate/severe PVL. CONCLUSIONS: Despite comparable device success rates, horizontal aorta represented a technical challenge only in the Evolut-R subgroup, which showed higher rates of moderate/severe PVL than Portico and Acurate-NEO, and was associated with a low implant.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Aorta , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Complicações Pós-Operatórias , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
9.
Echocardiography ; 38(11): 1913-1923, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34755379

RESUMO

BACKGROUND: Mitral valve (MV) repair with MitraClip system is a safe treatment option for high-risk patients with significant mitral regurgitation (MR). We aimed to characterize, by three-dimensional echocardiography (3D-E), changes occurring in MV after implantation of third generation MitraClip XTR device, with specific reference to the underlying MR mechanism (functional vs degenerative, FMR vs DMR). METHODS: We prospectively enrolled 59 patients, who underwent intra-procedural 3D-E before and after device deployment. Three-D datasets were analyzed off-line, using a dedicated semiautomatic software, to obtain parametric quantification of mitral anatomy. RESULTS: Post-procedural MR of mild or lesser degree was achieved in 40 patients (68%), with no differences between FMR and DMR (p 0.9). After MitraClip XTR implantation, the FMR group experienced an immediate annular resizing, with reduction of antero-posterior diameter (p 0.024) and sphericity index (p 0.017), next to a recovery of physiological saddle-shape, defined by lower non-planar angle (p ≤0.001) and higher annulus height to commissural width ratio (p ≤0.001). On the opposite, the DMR group revealed a significant decrease of maximum annular velocity (p 0.027), addressing a mechanic effect of the device deployment. Finally, baseline anterior mitral leaflet angle was found as an independent predictor of acute procedural result (OR 6.7, [CI 1.01-44.33], p 0.049). CONCLUSIONS: MitraClip XTR implantation acts in restoring the original mitral geometry, with distinctive effects according to MR mechanism. Three-D parametric quantification of MV sheds new light on changes occurring in the valvular apparatus, and helps identifying possible new predictors of acute procedural success.


Assuntos
Ecocardiografia Tridimensional , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Ecocardiografia Transesofagiana , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
10.
Cardiology ; 137(2): 114-120, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28324874

RESUMO

Percutaneous mitral valve repair (PMVR) with the MitraClip system (Abbott Vascular, Santa Clara, CA, USA) is a valid therapeutic option for patients with severe mitral regurgitation (MR) deemed to be at high or prohibitive surgical risk. Despite the reassuring data on efficacy and long-term durability of the procedure, the proportion of patients with residual or relapsing severe MR after MitraClip therapy is not negligible. In light of the detrimental prognostic impact of severe MR, repeat interventions are increasingly performed in clinical practice using different techniques. In high-risk settings, percutaneous procedures have proven to be effective and safe at reducing MR. Building on this, we sought to summarize the current landscape and clinical experience of reinterventions after failed MitraClip therapy, so as to assist physicians facing the clinical hurdle of proper treatment management after failed PMVR.


Assuntos
Cateterismo Cardíaco/instrumentação , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/terapia , Valva Mitral/diagnóstico por imagem , Idoso , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia Transesofagiana , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Recidiva , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
11.
Echocardiography ; 34(9): 1379-1381, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28612452

RESUMO

We present a case of a patient with severe mitral regurgitation referred to our Institution for an echocardiographic examination as part of the routine workup to assess the eligibility for mitral valve percutaneous repair with either the MitraClip or Cardioband systems. Echocardiography showed the presence of an unusual interatrial membrane in the left atrium that represented a contraindication for the puncture of the interatrial septum. The patient was finally deferred to percutaneous mitral valve replacement using transapical access.


Assuntos
Septo Interatrial/cirurgia , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Átrios do Coração/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Insuficiência da Valva Mitral/cirurgia , Idoso , Septo Interatrial/diagnóstico por imagem , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Comunicação Interatrial/complicações , Comunicação Interatrial/diagnóstico , Humanos , Masculino , Valva Mitral , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/etiologia
12.
Artigo em Inglês | MEDLINE | ID: mdl-38702260

RESUMO

BACKGROUND: Previous studies have investigated a 1 to 6-month short dual antiplatelet therapy (S-DAPT) after percutaneous coronary intervention (PCI) with modern drug eluting-stents to reduce bleeding events. OBJECTIVES: To investigate cardiovascular outcomes in patients at high bleeding risk (HBR) according to the Academic Research Consortium for High Bleeding Risk (ARC-HBR) criteria after PCI with the Synergy bioresorbable-polymer everolimus-eluting stents (EES). METHODS: We applied ARC-HBR criteria in the population of the prospective, single-arm, multicenter POEM (Performance of Bioresorbable Polymer-Coated Everolimus-Eluting Synergy Stent in Patients at HBR Undergoing Percutaneous Coronary Revascularization Followed by 1-Month Dual Antiplatelet Therapy) trial. The primary endpoint was a composite of cardiac death, myocardial infarction, or definite or probable stent thrombosis at 12 months. RESULTS: The original POEM cohort included 356 patients (80.4 %) fulfilling ARC-HBR criteria. Oral anticoagulant (OAC) usage and age ≥75 years were the most frequent major and minor ARC-HBR criteria, respectively. The ARC-HBR group was mainly represented by men (71.1 %), with 74.4 ± 9.3 years and a high burden of cardiovascular risk factors. DAPT was prescribed in 79.3 %, and single antiplatelet (SAPT) with OAC in 18.7 %. 12-month follow-up was completed in 96.2 %. The primary endpoint occurred in 5.2 % (95 % CI 3.29-8.10) of patients, whereas bleeding Academic Research Consortium type 3-5 occurred in 2.7 % (95 % CI, 1.39 %-5.05 %). CONCLUSION: Previous results of the POEM trial showed positive outcomes regarding ischemic and bleeding events with an S-DAPT regimen after Synergy EES. These results are also confirmed in sub-group analysis when ARC-HBR criteria are applied.

13.
Int J Cardiol ; 413: 132317, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38986745

RESUMO

AIM: The aims of this study were: i) to report the prevalence of low-risk patients with degenerative mitral regurgitation (DMR) undergoing mitral transcatheter edge-to-edge repair (M-TEER) in a real-world setting; ii) to evaluate the prognostic significance of EuroSCORE II; iii) to determine whether an optimal M-TEER provides a mortality benefit regardless of EuroSCORE-II. METHODS: We analyzed data from the GIOTTO registry that enrolled patients undergoing M-TEER in Italy. We included only patients with DMR. Two groups were defined: patients with EuroSCORE<4% and with EuroSCORE≥4%. A further stratification according to variables included in the EuroSCORE-II was made. Interaction between EuroSCORE-II and optimal procedural success was evaluated. Outcome of interest was all-cause death at 2-year. RESULTS: Among 1659 patients prospectively enrolled in the GIOTTO registry, 657 had DMR, 364 with an EuroSCORE<4% (53%) and 311 with an EuroSCORE≥4% (47%). Patients with lower EuroSCORE were older with less comorbidities. All-cause mortality was higher in patients with EuroSCORE≥ vs <4%. EuroSCORE II ≥ 4% was independently associated with an increased risk of mortality (HR 2.36, 95%CI 1.28-4.38, p = 0.007). Among variables included in the EuroSCORE-II, Left Ventricular Ejection Fraction<35% and systolic Pulmonary Artery Pressure ≥ 50mmhg were independent predictors of clinical outcome. Two-year all-cause death was higher in patients without optimal MR reduction regardless of the calculated surgical risk (p for interaction 0.3). CONCLUSION: More than half of patients with DMR undergoing M-TEER had a Euroscore<4% with a median age of 81. An optimally successful M-TEER was associated with a lower mortality regardless of EuroSCORE.

14.
Cardiovasc Revasc Med ; 55: 22-27, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37076413

RESUMO

BACKGROUND: TAVR is an established treatment for patients with severe symptomatic aortic stenosis. Different THV platforms are nowadays available, each of them with its inherent limitations and others are under development aiming at overcoming such limitations. We thus sought to investigate the performance and 1-year clinical outcome of a new generation, balloon expandable, THV: the Myval™ (Meril Life Sciences Pvt. Ltd., Vapi, Gujarat, India). METHODS: This registry included the first 100 consecutive patients (mean age 80.7 ± 7.7; STS 4.3 ± 3.3 %), who underwent transcatheter aortic valve implantation for severe stenosis of the native aortic valve from May 2020 to December 2020, in two Italian Centers. Clinical and procedural outcomes were defined according to VARC-3 criteria. RESULTS: Transfemoral Myval THV was successfully implanted in all patients, with no intra-hospital mortality (technical success 100 %): vascular access complications were all "minor" (16 %), and managed by compression/balloon inflation; no cases of annular rupture or coronary obstruction occurred; 5 % of patients required an in-hospital pacemaker implantation (PM). Device success was 99 %. Overall and cardiovascular mortality were 6 % (CI 5 %-7 %) and 4 % (CI 2 %-5 %) at 1- year, while 12 % (CI 9 %-14 %) and 7 % (6-9 %) at 2 years. A total of 9 % of the patients required a PM within 12 months, and no further PM implantation occurred afterwards. No cerebrovascular events, renal failure and myocardial infarction occurred between discharge and 2-year follow-up. No events of structural valve deterioration but a sustained improvement of echocardiographic parameters were observed. CONCLUSION: The Myval THV has a promising safety/efficacy profile at 2 year follow up. This performance should be further evaluated in the context of randomized trials to better elucidate its potential.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Resultado do Tratamento , Sistema de Registros , Desenho de Prótese
15.
Front Cardiovasc Med ; 10: 1199475, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37745092

RESUMO

Background: Third generation drug-eluting stents (DES) potentially offer better technical performance and reduced neointimal proliferation than previous generation DES. The XLIMIT non-inferiority trial evaluated the performance of the Xlimus (a novel sirolimus-eluting coronary stent system) in terms of endothelialization and tissue healing compared to the bioresorbable polymer Synergy DES. Methods: A total of 177 patients undergoing percutaneous coronary intervention (PCI) were randomized in a 2:1 ratio (2 Xlimus: 1 Synergy). The primary endpoints, defined as the in-stent neointimal volume weighted by the sum of the lengths of the implanted stent (ISNV) and the in-stent neointimal percent volume obstruction (%VO) were evaluated at 6-9 months by means of optical coherence tomography (OCT). Additional OCT parameters as well as clinical endpoints were also collected. Results: Most of the patients were males (77.4%), and the mean age was 64 years. One third of the population had stable angina/silent ischemia. A total of 300 stents (237 lesions) were analyzed: 198 (152 lesions) were in the Xlimus group, and 102 (85 lesions) in the Synergy group. The ISNV in the Xlimus group was 30.7 ± 24.5 mm3 while in the Synergy group it was 26.5 ± 26.7 mm3: the difference between the two means was 0.08 (-0, 04-0, 45), p = 0.018, thus meeting the non-inferiority hypothesis. The %VO was 16.3% ± 10.4% and 13.3% ± 10.8% in the Xlimus and Synergy groups, respectively: the difference between the two means was 3.0 (-0, 06-4, 2), (p = 0.01), thus meeting the non-inferiority hypothesis. No difference was found with respect to the secondary OCT endpoints as well as for clinical endpoints. Conclusions: The study results confirm that the biological interaction of the Xlimus and Synergy DES with the coronary artery is comparable, and that translates in very reassuring OCT parameters at follow-up: as such, the Xlimus is non-inferior to the Synergy. Clinical Trial Registration: ClinicalTrials.gov, identifier (NCT03745053).

16.
Am J Cardiol ; 200: 178-187, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37331223

RESUMO

Despite the growing experience with MitraClip in the broad spectrum of mitral regurgitation (MR), limited data are available regarding the independent prognostic role on survival of different mitral regurgitation etiology subtypes. We sought to evaluate the impact of flail leaflet etiology in a large series of patients with primary MR (PMR) who underwent MitraClip treatment. The study included 588 patients with significant PMR from the multicenter GIOTTO (Italian Society of Interventional Cardiology [GIse] registry Of Transcatheter treatment of mitral valve regurgitaTiOn), stratified into 2 groups according to MR etiology: flail+ (n = 300) and flail- (n = 288). The primary end point was a composite of cardiac death and first rehospitalization for heart failure (HF). To account for the baseline differences, patients were propensity score-matched 1:1. Flail leaflet etiology was present in about a half of the patients. Acute technical success was achieved in 98% of the overall cohort, with no significant differences between the study groups (p = 0.789). At the 2-year Kaplan-Meier analysis, the primary end point occurred in 13% of flail+ patients compared with 23% in flail- (p = 0.009). The flail+ group presented lower rates of both cardiac death and rehospitalization for HF, whereas a similar overall death rate was observed between the groups. A multivariate Cox regression analysis identified flail leaflet etiology as an independent predictor of favorable outcome in terms of the primary end point (hazard ratio 0.141, 95% confidence interval 0.049 to 0.401, p <0.001). After propensity score matching, flail+ patients had confirmed lower rates of cardiac mortality and rehospitalization for HF but similar rates of overall death. In conclusion, flail leaflet-related etiology was common in patients with PMR who underwent MitraClip treatment and was an independent predictor of midterm favorable clinical outcomes.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Prognóstico , Resultado do Tratamento , Modelos de Riscos Proporcionais , Insuficiência Cardíaca/complicações , Morte , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco/efeitos adversos
17.
Panminerva Med ; 65(4): 443-453, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37259492

RESUMO

BACKGROUND: The clinical impact of coronary artery disease (CAD) on the prognosis of patients undergoing MitraClip implantation is still unclear. METHODS: One thousand nine hundred fifty-three patients undergoing MitraClip implantation included in the multicenter GIOTTO Registry were stratified according to CAD. Endpoints were all-cause death, cardiac death, and re-hospitalization for heart failure at follow-up (median 15.8 months). RESULTS: Although younger, CAD patients were more symptomatic, had worse cardiovascular risk profile, higher burden of comorbidities, more frequently affected by functional MR, with higher left ventricle (LV) diameters and lower ejection fraction (EF). At follow-up, CAD patients showed higher rates of all-cause death (25.4% vs. 19.6%; P=0.002), cardiovascular death (14.0% vs. 10.1%; P=0.007) and re-hospitalization for heart failure (13.9% vs. 10.2%; P=0.011). Dividing the population according to mitral regurgitation (MR) etiology (functional vs. non-functional MR), no differences were observed between CAD and no-CAD patients. At multivariate logistic regression, NYHA III/IV class, prior heart failure hospitalization, severe chronic kidney disease, atrial fibrillation, LV end-diastolic diameter and LVEF<30% but not CAD resulted independent predictors of all-cause death. The same finding was confirmed even after propensity score adjustment. CONCLUSIONS: CAD did not show a relevant impact on mid-term prognosis per se, but seemed to identify a more complex and diseased cohort of patients with worse clinical and functional status.


Assuntos
Doença da Artéria Coronariana , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/cirurgia , Insuficiência Cardíaca/complicações , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Resultado do Tratamento
18.
EuroIntervention ; 19(11): e926-e936, 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-37946539

RESUMO

BACKGROUND: In the context of primary mitral regurgitation (PMR), the selection of patients for transcatheter edge-to-edge repair (TEER) does not include a systematic assessment of PMR-associated cardiac remodelling. AIMS: We aimed to investigate the epidemiology and prognostic significance of different phenotypes of extra-mitral valve (MV) cardiac involvement in a large series of patients with PMR referred for TEER. METHODS: The study included 654 patients from the multicentre Italian GIOTTO registry, stratified into groups according to extra-mitral valve (MV) cardiac involvement. The primary endpoint was all-cause death at 2-year follow-up. RESULTS: Patients with no cardiac involvement (NI; n=58), left heart involvement (LHI; n=343) and right heart involvement (RHI; n=253) were analysed. Acute technical success was achieved in 98% of patients. Kaplan-Meier curve analysis revealed significantly worse survival in patients with LHI and RHI (p=0.041). On multivariate Cox regression analysis, extra-MV cardiac involvement, haemoglobin level and technical success were independent predictors of the primary endpoint occurrence. CONCLUSIONS: Grading cardiac involvement may help refine risk stratification, since at least 1 group of extra-MV cardiac involvement represents in itself a negative predictor of midterm outcome.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estimativa de Kaplan-Meier , Análise Multivariada , Pacientes , Resultado do Tratamento , Cateterismo Cardíaco
20.
Cardiovasc Revasc Med ; 42: 161-170, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35361568

RESUMO

Over the last two decades there has been a significant shift towards the use of bioprostheses in the context of surgical aortic valve replacement, despite the well-known process of structural valve deterioration (SVD). This process has been extensively evaluated even though with many different definitions and methods, thus, the true long-term durability of surgical bioprostheses is not yet fully elucidated. Following the increasing implementation of the transcatheter aortic valve implantation (TAVI) technology, a better understanding of the long-term durability of transcatheter bioprostheses has become increasingly important as well, despite the limited availability of such data compared to the surgical experience. This lack of knowledge is a major barrier to the use of TAVI platforms to treat relatively younger patients. We thus aimed at providing an overview on long-term actual data concerning the durability of bioprostheses focusing on definition, incidence, and subsequent management of SVD of both surgical and transcatheter bioprosthetic aortic valves.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Desenho de Prótese , Falha de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento