RESUMO
BACKGROUND: Stroke after durable left ventricular assist device (d-LVAD) implantation portends high mortality. The incidence of ischemic and hemorrhagic stroke and the impact on stroke outcomes of temporary mechanical circulatory support (tMCS) management among patients requiring bridge to d-LVAD with micro-axial flow-pump (mAFP, Abiomed) is unsettled. METHODS: Consecutive patients, who underwent d-LVAD implantation after being bridged with mAFP at 19 institutions, were retrospectively included. The incidence of early ischemic and hemorrhagic stroke after d-LVAD implantation (<60 days) and association of pre-d-LVAD characteristics and peri-procedural management with a specific focus on tMCS strategies were studied. RESULTS: Among 341 patients, who underwent d-LVAD implantation after mAFP implantation (male gender 83.6%, age 58 [48-65] years, mAFP 5.0/5.5 72.4%), the early ischemic stroke incidence was 10.8% and early hemorrhagic stroke 2.9%. The tMCS characteristics (type of mAFP device and access, support duration, upgrade from intra-aortic balloon pump, ECMELLA, ECMELLA at d-LVAD implantation, hemolysis, and bleeding) were not associated with ischemic stroke after d-LVAD implant. Conversely, the device model (mAFP 2.5/CP vs. mAFP 5.0/5.5: HR 5.6, 95%CI 1.4-22.7, p = 0.015), hemolysis on mAFP support (HR 10.5, 95% CI 1.3-85.3, p = 0.028) and ECMELLA at d-LVAD implantation (HR 5.0, 95% CI 1.4-18.7, p = 0.016) were associated with increased risk of hemorrhagic stroke after d-LVAD implantation. Both early ischemic (HR 2.7, 95% CI 1.9-4.5, p < 0.001) and hemorrhagic (HR 3.43, 95% CI 1.49-7.88, p = 0.004) stroke were associated with increased 1-year mortality. CONCLUSIONS: Among patients undergoing d-LVAD implantation following mAFP support, tMCS characteristics do not impact ischemic stroke occurrence, while several factors are associated with hemorrhagic stroke suggesting a proactive treatment target to reduce this complication.
Assuntos
Coração Auxiliar , Sistema de Registros , Humanos , Coração Auxiliar/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Incidência , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/epidemiologia , Insuficiência Cardíaca/terapia , AVC Isquêmico/etiologia , AVC Isquêmico/epidemiologia , Resultado do Tratamento , Acidente Vascular Cerebral Hemorrágico/etiologia , Acidente Vascular Cerebral Hemorrágico/epidemiologiaRESUMO
BACKGROUND: A growing proportion of transplant donors and recipients have a history of COVID-19 infection. This study sought to characterize clinical practice after recipient or donor COVID-19 infection. METHODS: An online survey was distributed to heart transplant clinicians through a professional society message board and social media. Responses were collected between September 29 and November 5, 2021. RESULTS: There were 222 health care professionals (68% transplant cardiologists, 22% transplant surgeons, 10% other) across diverse geographic regions who completed the survey. While there was significant variation in donor acceptance, as it relates to past and current COVID-19 infection, the respondents were fairly cautious: 28% would not typically accept a donor with a history of COVID-19 regardless of the infection course and > 80% would not accept donors who had evidence of myocardial dysfunction during past COVID-19 infection, or who died of COVID-19 or its complications. The timing of candidate reactivation on the waiting list after COVID-19 infection also varied and often diverged from scenarios addressed by social guidelines. Eighty-one percent of the respondents felt COVID-19 vaccine should be mandatory before transplant, but this rate varied by geographic region. CONCLUSION: Our results reflect evolving experience of the heart transplant field at a time of lack of high-quality evidence. In the absence of longer-term outcome data for donors and transplant candidates with history of COVID-19 infection, clinicians remain cautious; however, this approach will likely need to be refined as an increasing proportion of the population will continue to be infected with COVID-19.
Assuntos
COVID-19 , Transplante de Coração , COVID-19/epidemiologia , Vacinas contra COVID-19 , Humanos , Inquéritos e Questionários , Doadores de Tecidos , TransplantadosRESUMO
BACKGROUND: Cardiopulmonary bypass (CPB) during left ventricular assist device (LVAD) implantation provides circulatory support and allows for safe inspection of the left ventricle (LV), whereas circulatory support by veno-arterial extracorporeal life support (va-ECLS) or off-pump implantation may reduce postoperative bleeding and inflammatory response. METHODS: Retrospective analysis of 616 consecutive adult patients who received an LVAD via median sternotomy between January 1, 2015 and December 31, 2019. All patients undergoing concomitant intracardiac procedures other than closure of persistent foramen ovale or atrial septal defect and redo surgeries were excluded from the analysis. The remaining patients (n = 222) were divided into two groups and 1:1 propensity score-matched regarding preoperative parameters: patients who underwent LVAD implantation with LV inspection employing CPB (CPB group, n = 62) and without LV inspection on va-ECLS or off-pump (non-CPB group, n = 62). RESULTS: The groups were well balanced with regard to preoperative baseline characteristics (standard difference <0.1). Patients in the CPB group required more blood transfusions (median 2 vs. 0 units, p = 0.031) during surgery and in the first 24 h afterwards. The median intensive care unit stay was longer in the CPB group (18 vs. 11 days, p = 0.021). The CPB group showed an absence of perioperative stroke and a smaller number of events per patient-year for postoperative ischemic stroke (0.02 vs. 0.12, p = 0.003). 30-day survival (87% vs. 87.1%) and 1-year survival (80.3% vs. 74%) were similar in both groups (p = 0.78). CONCLUSION: Visual LV inspection on CPB may reduce the risk of postoperative ischemic stroke. Despite the negative effects of employing CPB in lieu of other intraoperative strategies, survival was similar in both groups.
Assuntos
Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Adulto , Ponte Cardiopulmonar , Oxigenação por Membrana Extracorpórea/métodos , Ventrículos do Coração , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Resultado do TratamentoRESUMO
BACKGROUND AND METHODS: Microaxial left ventricular assist devices are used increasingly for treating cardiogenic shock. We compared the short-term outcome of patients supported with different microaxial devices for cardiogenic shock. A retrospective propensity score-adjusted analysis was performed in cardiogenic shock patients treated with either the Impella CP (n = 64) or the Impella 5.0/5.5 (n = 62) at two tertiary cardiac care centers between 1/14 and 12/19. RESULTS: Patients in the Impella CP group were significantly older (69.6 ± 10.7 vs. 58.7 ± 11.9 years, p = .001), more likely in INTERMACS profile 1 (76.6% vs. 50%, p = .003) and post-C-reactive protein (CPR) (36% vs. 13%, p = .006). The median support time was 2.0 days [0.0, 5.3] in the CP group vs. 8.5 days [4.3, 15.8] in the 5.0/5.5 group (p < .001). The unadjusted 30-day survival was significantly higher in the Impella 5.0/5.5 group (58% vs. 36%, p = .021, odds ratio [OR] for 30-day survival on Impella 5.0/5.5 was 3.68 [95% confidence interval [CI]: [1.46-9.90]], p = .0072). After adjustment, the 30-day survival was similar for both devices (OR: 1.23, 95% CI: [0.34-4.18], p = .744). Lactate levels above 8 mmol/L and preoperative CPR were associated with a significant mortality increase in both cohorts (OR: 10.7, 95% CI: [3.45-47.34], p < .001; OR: 13.2, 95% CI: [4.28-57.89], p < .001, respectively). CONCLUSION: Both Impella devices offer a similar effect with regard to survival in cardiogenic shock patients. Preoperative CPR or lactate levels exceeding 8 mmol/L immediately before implantation have a poor prognosis on Impella CP and Impella 5.0/5.5.
Assuntos
Coração Auxiliar , Choque Cardiogênico , Humanos , Pontuação de Propensão , Estudos Retrospectivos , Choque Cardiogênico/terapia , Resultado do TratamentoRESUMO
The handling of left ventricular assist devices (LVADs) can be challenging for patients and requires appropriate training. The devices' usability impacts patients' safety and quality of life. In this study, an eye tracking supported human factors testing was performed to reveal problems during use and test the trainings' effectiveness. In total 32 HeartWare HVAD patients (including 6 pre-VAD patients) and 3 technical experts as control group performed a battery change (BC) and a controller change (CC) as an everyday and emergency scenario on a training device. By tracking the patients' gaze point, task duration and pump-off time were evaluated. Patients with LVAD support ≥1 year showed significantly shorter BC task duration than patients with LVAD support <1 year (p = 0.008). In contrast their CC task duration (p = 0.002) and pump-off times (median = 12.35 s) were higher than for LVAD support patients <1 year (median = 5.3 s) with p = 0.001. The shorter BC task duration for patients with LVAD support ≥1 year indicate that with time patients establish routines and gain confidence using their device. The opposite effect was found for CC task duration and pump-off times. This implies the need for intermittent re-training of less frequent tasks to increase patients' safety.
Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Tecnologia de Rastreamento Ocular , Humanos , Qualidade de Vida , Estudos Retrospectivos , Fatores de TempoRESUMO
AIMS: Haemodynamic load induces cardiac remodelling via mechano-transduction pathways, which can further trigger inflammatory responses. We hypothesized that particularly in an inflammatory disorder such as myocarditis, a therapeutic strategy is required which, in addition to providing adequate circulatory support, unloads the left ventricle, decreases cardiac wall stress, and mitigates inflammatory responses. METHODS AND RESULTS: Axial flow pumps such as the Impella systems comply with these requirements. Here, we report a potential mode-of-action of prolonged Impella support (PROPELLA concept) in fulminant myocarditis, including a decrease in cardiac immune cell presence, and integrin α1, α5, α6, α10 and ß6 expression during unloading. CONCLUSION: PROPELLA may provide benefits beyond its primary function of mechanical circulatory support in the form of additional disease-altering effects, which may contribute to enhanced myocardial recovery/remission in patients with chronic fulminant myocarditis.
Assuntos
Miocardite/terapia , Biópsia , Terapia Combinada , Circulação Extracorpórea/métodos , Humanos , Imunossupressores/uso terapêutico , Modelos Teóricos , Miocardite/etiologia , Miocardite/patologia , Miocardite/fisiopatologia , Miocárdio/patologia , Resultado do TratamentoRESUMO
BACKGROUND: Takotsubo syndrome is, by definition, a reversible form of acute heart failure. If cardiac output is severely reduced, Takotsubo syndrome can cause cardiogenic shock, and mechanical circulatory support can serve as a bridge to recovery. To date, there are no recommendations on when to use mechanical circulatory support and on which device is particularly effective in this context. Our aim was to determine the best treatment strategy. METHODS: A systematic literature research and analysis of individual patient data was performed in MEDLINE/PubMed according to PRISMA guidelines. Our research considered original works published until 31 July 2023. RESULTS: A total of 93 publications that met the inclusion criteria were identified, providing individual data from 124 patients. Of these, 62 (50%) were treated with veno-arterial extracorporeal life support (va-ECLS), and 44 (35.5%) received a microaxial left ventricular assist device (Impella). Eighteen patients received an Impella CP and twenty-one an Impella 2.5. An intra-aortic balloon pump (IABP) without other devices was used in only 13 patients (10.5%), while other devices (BiVAD or Tandem Heart) were used in 5 patients (4%). The median initial left ventricular ejection fraction was 20%, with no difference between the four device groups except for the IABP group, which was less affected by cardiac output failure (p = 0.015). The overall survival was 86.3%. Compared to the other groups, the time to cardiac recovery was shorter with Impella (p < 0.001). CONCLUSIONS: Though the Impella treatment is new, our analysis may show a significant benefit of Impella compared to other MCS strategies for cardiogenic shock in Takotsubo syndrome.
RESUMO
Early planned institution of temporary right ventricular assist device (RVAD) support with the CentriMag (Levitronix LLC, Waltham, MA, USA) in left ventricular assist device (LVAD) recipients was compared with permanent biventricular assist device (BVAD) or total artificial heart (TAH) support. Between 2007 and 2011, 77 patients (age range: 25-70 years) with preoperative evidence of biventricular dysfunction (University of Pennsylvania score >50; University of Michigan score >5) were included. Forty-six patients (38 men; median age 54.5 years, range: 25-70 years) underwent LVAD placement combined with temporary RVAD support (group A); in 31 patients (25 men; median age 56.7 years, range: 28-68 years), a permanent BVAD or TAH implantation (group B) was performed. Within 30 days, 12 patients from group A (26.08%) and 14 patients from group B (45.1%) died on mechanical support (P = 0.02). Thirty patients (65.2%) in group A were weaned from temporary RVAD support and three (6.5%) underwent permanent RVAD (HeartWare, Inc., Framingham, MA, USA) placement. A total of 26 patients (56.5%) were discharged home in group A versus 17 (54.8%) in group B (P = 0.56). Three patients (8.5%) received heart transplantation in group A and six (19.3%) in group B (P = 0.04). In group A, 90-day and 6-month survival was 54.3% (n = 25) versus 51.6% (n = 16) in group B (P = 0.66). In group A, 1-year survival was 45.6% (n = 21) versus 45.1% (n = 14) in group B (P = 0.81). The strategy of planned temporary RVAD support in LVAD recipients showed encouraging results if compared with those of a similar permanent BVAD/TAH population. Weaning from and removal of the temporary RVAD support may allow patients to be on LVAD support only despite preoperative biventricular dysfunction.
Assuntos
Insuficiência Cardíaca/cirurgia , Transplante de Coração/métodos , Coração Artificial , Coração Auxiliar , Disfunção Ventricular/cirurgia , Adulto , Idoso , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Risco , Resultado do TratamentoRESUMO
Transaxillary implantation of a temporary microaxial left ventricular assist device in patients suffering from cardiogenic shock is an established technique. We present a 77-year-old female patient with severe mitral regurgitation. She underwent minimally invasive surgical mitral valve replacement. After an uneventful postoperative course, the patient developed acute heart failure on the 11th postoperative day. Transthoracic echocardiography revealed new onset of Takotsubo cardiomyopathy with a severely decreased left ventricular ejection fraction. Implantation of a microaxial flow pump for left ventricular decompression was scheduled. Preoperative computed tomography revealed a rectangular course of the right subclavian artery. To advance the Impella, we employed an introducer fitted over the guidewire behind the Impella device as a 'cue stick' to move the rigid part of the pump forward to overcome the kinking using a 'shuffleboard technique'. The haemodynamic situation stabilized immediately after implantation. The Impella 5.5 was successfully weaned after 6 days of support. In the event of (rectangular) kinking of the subclavian artery, the 'shuffleboard technique' can be used for the successful positioning of the pump.
RESUMO
Implantation of a temporary percutaneous right ventricular assist device (RVAD) in patients with right heart failure after left ventricular assist device (LVAD) implantation is an established technique that may cause complications. We present a 60-year-old male patient who underwent urgent LVAD implantation. On the second postoperative day the patient developed acute right heart failure. We implanted a temporary percutaneous RVAD with two cannulas via the right internal jugular vein and the right femoral vein. Transesophageal echocardiography revealed severe pulmonary insufficiency. After performing re-sternotomy we anastomosed a prosthetic graft to the pulmonary trunk (PT), performed subxiphoid tunneling of the graft and replaced the transjugular outflow cannula. The pulmonary regurgitation caused by the percutaneous transvalvular cannula disappeared. In such case a direct anastomosis to the PT is the solution.
RESUMO
BACKGROUND: Impella 5.0 and 5.5 (summarized as Impella 5+) are microaxial, catheter-based left ventricular assist devices (LVAD) that are implanted via a vascular graft sutured to the axillary artery and provide blood flow of up to 5.5 liter/min. This study aims to investigate the incidence of long-term complications following circulatory support with Impella 5+. METHODS: A single-center retrospective analysis of 203 consecutive adult patients treated between January 2017 and September 2021 with a surgically implanted Impella 5.0 or 5.5 via a vascular graft sutured to the axillary artery. RESULTS: The median Impella support duration was 8 days. Of 203 patients, 78 (38.4%) died while on temporary mechanical circulatory support. Fifty-five (27.1%) were successfully weaned from Impella 5+ and 70 (34.5%) were bridged to a durable LVAD with a median follow-up time of 232 (IQR 68.5, 597) days after Impella 5+ explantation. In 119 of these patients, the Impella was explanted and the vascular graft was shortened, ligated, and pushed under the pectoralis muscle; in 6 patients early graft infection prompted complete graft removal during explantation. In addition, 13 patients (10.9%) developed a late-onset graft infection after a median of 86 days, requiring complete (n = 10) or partial (n = 2) explantation of the retained graft. In 1 patient, the graft infection was successfully treated by conservative therapy. Our analysis identified no specific risk factors for graft infections. Of the 203 patients, 5 (2.5%) developed a brachial plexus injury resulting in neurological dysfunction. CONCLUSIONS: In 10.9% of patients, retaining the vascular graft was complicated by a late graft infection. Complete explantation of the graft prosthesis may decrease the infection rate, but may in turn increase the risk of brachial plexus injury. On the other hand, this method offers the possibility of bedside explantation.
Assuntos
Coração Auxiliar , Choque Cardiogênico , Adulto , Humanos , Choque Cardiogênico/terapia , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos , Complicações Pós-Operatórias/etiologiaRESUMO
OBJECTIVES: Cardiogenic shock (CS) can occur in patients with Takotsubo syndrome (TTS). As TTS has received increasing attention and has been more closely researched, several aspects of the pathogenesis have been identified, particularly that an excessive release of catecholamines plays an important role. Nevertheless, evidence on specific therapy concepts is still lacking. As a result, TTS with severe hemodynamic instability and low cardiac output creates unique challenges, and mechanical circulatory support is needed with as few inotropic drugs as possible. METHODS: We present a 77-year-old female patient who underwent minimally invasive surgical mitral valve replacement. After an uneventful course, the patient developed acute heart failure eleven days after surgery. Transthoracic echocardiography (TTE) revealed a new onset of TTS. The patient needed left ventricular venting and full haemodynamic flow. We successfully implanted a microaxial left ventricular assist device (Impella 5.5) using the transaxillary approach. The haemodynamic situation stabilised immediately. The patient was weaned and the Impella 5.5 was explanted after five days. CONCLUSION: We present the first-in-man implantation of a transaxillary Impella 5.5 in a patient with TTS. The patient benefitted from Impella 5.5 therapy with full haemodynamic support and venting of the left ventricle.
Assuntos
Coração Auxiliar , Cardiomiopatia de Takotsubo , Feminino , Humanos , Idoso , Choque Cardiogênico/etiologia , Choque Cardiogênico/cirurgia , Coração Auxiliar/efeitos adversos , Cardiomiopatia de Takotsubo/complicações , Cardiomiopatia de Takotsubo/cirurgia , Resultado do Tratamento , Estudos RetrospectivosRESUMO
Ventricular septal defect (VSD) is a rare but severe complication of myocardial infarction (MI). Temporary mechanical circulatory support (MCS) can be used as a bridge to VSD closure, heart transplantation, or ventricular assist device. We describe the use of Impella device in this context based on a multicenter European retrospective registry (17 centers responded). Twenty-eight post-MI VSD patients were included (Impella device were 2.5 for 1 patient, CP for 20, 5.0 for 5, and unknown for 2). All patients were in cardiogenic shock with multiple organ failure (SAPS II 41 [interquantile range {IQR} = 27-53], lactate 4.0 ± 3.5 mmol/L) and catecholamine support (dobutamine 55% and norepinephrine 96%). Additional temporary MCS was used in 14 patients (50%), mainly extracorporeal life support (ECLS) (n = 9, 32%). Severe bleedings were frequent (50%). In-hospital and 1 year mortalities were 75%. Ventricular septal defect management was surgical for 36% of patients, percutaneous for 21%, and conservative for 43%. Only surgically managed patients survived (70% in-hospital survival). Type and combination of temporary MCS used were not associated with mortality (Impella alone or in combination with intra-aortic balloon pump [IABP] or ECLS, p = 0.84). Impella use in patients with post-MI VSD is feasible but larger prospective registries are necessary to further elucidate potential benefits of left ventricular unloading in this setting.
Assuntos
Comunicação Interventricular , Coração Auxiliar , Infarto do Miocárdio , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Infarto do Miocárdio/complicações , Infarto do Miocárdio/cirurgia , Choque Cardiogênico/etiologia , Choque Cardiogênico/cirurgia , Coração Auxiliar/efeitos adversos , Balão Intra-Aórtico/efeitos adversos , Sistema de Registros , Comunicação Interventricular/cirurgia , Resultado do TratamentoRESUMO
OBJECTIVES: Myocardial recovery allows for left ventricular assist device (LVAD) explantations after long-term support. Several surgical approaches, including interventional decommissioning, off-pump explantation using a custom-made plug and complete LVAD removal through redo sternotomy, have been described. We present the results from an evaluation of the long-term follow-up of patients who received a titanium sintered plug after LVAD explantation. METHODS: We performed a retrospective, European, multicentre analysis of patients who received a titanium sintered plug to seal the apical fixation ring after LVAD explantation. Data were collected from a questionnaire that included demographics, procedural details and follow-up information. RESULTS: Out of 54 contacted centres in 12 countries (n = 179 patients), a total of 68 patients were successfully included in the study. The median follow-up was 34 months (interquartile range: 17-58.5 months); 57 (84%) patients had >1-year follow-up. At the time of the last follow-up, 55 (81%) patients were alive, with a Kaplan-Meier 1-year survival of 90.1% (95% confidence interval: 84.0-98.1%) and a 5-year survival of 80.0% (95% confidence interval: 68.4-92.9%). One patient (1.5%) developed a plug infection originating from an infected part of the incorporated driveline and, after complete removal, is currently in good condition. No postoperative stroke has been reported after plug implantation. CONCLUSIONS: In this European multicentre study, the use of a custom-made titanium plug to close the apical fixation ring after LVAD explantation resulted in a low incidence of plug-related complications. With the volume of patients undergoing LVAD explantations after myocardial recovery increasing, the plug has evolved as a simple alternative to more invasive device explantation procedures or decommissioning with a high risk for infection of the remaining system or stroke.
Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Resultado do TratamentoRESUMO
BACKGROUND: The HeartMate 3 (HM 3; Abbott) left ventricular assist device (LVAD) has improved hemocompatibility-related adverse outcomes. In sporadic cases, external compression of the outflow graft causing obstruction (eOGO) can result from substance accumulation between the outflow graft and its bend relief. We sought to evaluate the prevalence, course, and clinical implications of eOGO in an international study. METHODS: A multicenter retrospective analysis of HM 3 LVADs implanted between November 2014 and April 2021 (n = 2108) was conducted across 17 cardiac centers in 8 countries. We defined eOGO as obstruction >25% in the cross-sectional area in imaging (percutaneous angiography, computed tomography, or intravascular ultrasound). The prevalence and annual incidence were calculated. Serious adverse events and outcomes (death, transplantation, or device exchange) were analyzed for eOGO cases. RESULTS: Of 2108 patients, 62 were diagnosed with eOGO at a median LVAD support duration of 953 (interquartile range, 600-1267) days. The prevalence of eOGO was 3.0% and the incidence at 1, 2, 3, 4, and 5 years of support was 0.6%, 2.8%, 4.0%, 5.2%, and 9.1%, respectively. Of 62 patients, 9 were observed, 27 underwent surgical revision, 15 underwent percutaneous stent implantation, 8 received a heart transplant, and 2 died before intervention. One patient underwent surgical revision and later stent implantation. The mortality with therapeutic intervention was 9/53 (17.0%). CONCLUSIONS: Although uncommon, HM 3 LVAD-supported patients might develop eOGO with an increasing incidence after 1 year of support. Although engineering efforts to reduce this complication are under way, clinicians must maintain a focus on early detection and remain vigilant.
RESUMO
PURPOSE OF REVIEW: As permanent support with ventricular assist devices (VADs) has become a reality and increasing numbers of patients are being supported for several years, the interactions between the VAD and the body and the management of complications during life-long support have gained the interest of clinicians and biomedical engineers. RECENT FINDINGS: Several interactions between the body and the implanted pump, including changes in the coagulation system, structure and function of the aortic valve, VAD-related infections, and technical failure as well as psychosocial aspects and their specific management have been described. SUMMARY: With enormous progress made in VAD technology, the incidence of complications has decreased over the years. However, with longer times of support, many aspects of the interaction between the implanted pump and the patient's body have been recognized. The management of these interactions and possible complications remain challenging, but it is possible to achieve long-term event-free VAD support.
Assuntos
Insuficiência Cardíaca/terapia , Ventrículos do Coração/patologia , Coração Auxiliar/efeitos adversos , Valva Aórtica , Cateterismo , Falha de Equipamento , Insuficiência Cardíaca/patologia , Hemodinâmica , Humanos , Hipertensão Pulmonar , Fatores de Risco , Tromboembolia , Fatores de Tempo , Disfunção Ventricular DireitaRESUMO
BACKGROUND: Significant right ventricular failure (RVF) complicating left ventricular assist device (LVAD) placement has been reported at 10-30%. Although primarily indicated for left ventricular failure, ventricular assist devices (VADs) have become utilized in a biventricular setup to combat right ventricular failure (RVF) following LVAD implantation. With the advent of continuous-flow LVADs (CF-LVADs) superseding their pulsatile predecessors, the shift towards CF-biventricular assist devices (CF-BiVADs) come with the prospect of improved outcomes over previous pulsatile BiVADs. We aim to review the literature and determine the outcomes of CF-BiVAD recipients. METHODS: A systematic review was performed to determine the outcomes of CF-BiVADs. Pre-operative demographics and device configuration data was collected. Primary outcomes evaluated were short-term survival, long-term survival, duration of support, and survival to transplant. Secondary outcomes evaluated included intensive care unit (ICU) and hospital length of stay (ICU-LOS and HLOS, respectively), pump thrombosis, pump exchange. Median and interquartile range was reported where appropriate. A major limitation was the likely overlap of cohorts across publications, which may have contributed to some selection bias. RESULTS: Of 1,282 screened, 12 publications were evaluated. Sample size ranged from 4 to 93 CF-BiVAD recipients, and follow-up ranged from 6 to 24 months. Mean age ranged from 34 to 52 years old. Forty-five percent of CF-BiVADs had right atrial (RA-) inflow cannulation, with the remaining being right ventricular (RV). Thirty-day survival was a median of 90% (IQR 82-97.8%) and 12-month survival was a median of 58.5% (IQR 47.5-62%). Where reported, rate of pump thrombosis (predominantly the right VAD) was a median of 31% (IQR 14-36%), although pump exchange was only 9% (IQR 1.5-12.5%). CONCLUSIONS: RVF post-LVAD implantation is a high morbidity and mortality complication. There is no on-label continuous-flow RVAD currently available. Thus, the modifications of LVADs for right ventricular support to combat pump thrombosis has resulted in various techniques. BiVAD recipients are predominantly transplant candidates, and complications of pump thrombosis and driveline infection whilst on wait-list are of great consequence. This study demonstrates the need for an on-label CF-BiVAD.
RESUMO
Outflow graft obstruction in left ventricular assist devices (LVADs) is a rare complication whose clinical presentation may be subtle. We present six cases of outflow graft obstruction in patients on HeartMate 3 LVAD detected between 648 and 1,222 days on support. Detection principles are described and treatment strategies discussed. Three patients were successfully managed with stents, one underwent surgical revision, one patient died despite emergency treatment, and the last patient without symptoms was listed for heart transplantation.
Assuntos
Coração Auxiliar/efeitos adversos , Falha de Prótese , Trombose/diagnóstico , Trombose/etiologia , Trombose/terapia , Adulto , Idoso , Feminino , Insuficiência Cardíaca/cirurgia , Humanos , Pessoa de Meia-Idade , ReoperaçãoRESUMO
The coronavirus disease 2019 (COVID-19) pandemic has potentiated the need for implementation of strict safety measures in the medical care of surgical patients - and especially in cardiac surgery patients, who are at a higher risk of COVID-19-associated morbidity and mortality. Such measures not only require minimization of patients' exposure to COVID-19 but also careful balancing of the risks of postponing nonemergent surgical procedures and providing appropriate and timely surgical care. We provide an overview of current evidence for preoperative strategies used in cardiac surgery patients, including risk stratification, telemedicine, logistical challenges during inpatient care, appropriate screening capacity, and decision-making on when to safely operate on COVID-19 patients. Further, we focus on perioperative measures such as safe operating room management and address the dilemma over when to perform cardiovascular surgical procedures in patients at risk.