Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Hepatol ; 75(4): 879-887, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34052255

RESUMO

BACKGROUND & AIMS: Sorafenib has been the standard of care for patients with advanced hepatocellular carcinoma and although immunotherapeutic approaches are now challenging this position, it retains an advantage in HCV-seropositive patients. We aimed to quantify the rate of tumour progression in patients receiving sorafenib and relate this figure to survival, both overall, and according to viral status. METHODS: Using serial data from an international clinical trial we applied a joint model to combine survival and progression over time in order to estimate the rate of tumour growth as assessed by tumour burden and serum alpha-fetoprotein, and the impact of treatment on liver function. RESULTS: High tumour burden at baseline was associated with an increased risk of death. In patients still alive at the end of the study, the progression in relation to tumour burden was very low compared to those who died within the study. Overall, the change in mean tumour burden was 0.12 mm per day or an absolute growth rate of 3.6 mm/month. Median doubling time was 665 days. For those who progressed above 0.12 mm per day or the 12% rate, median survival was 234 days compared to 384 days if the rate was below 12%. Tumour growth rate and serum alpha-fetoprotein rise were significantly lower in those who were HCV seropositive as was the rate of decline in liver function. These results were replicated in 2 independent patient groups. CONCLUSION: Our analysis suggests that sorafenib treatment is associated with improved survival in patients with advanced hepatocellular carcinoma mainly by decreasing the rate of tumour growth and liver function deterioration among patients with HCV infection. LAY SUMMARY: Among patients receiving sorafenib for advanced hepatocellular carcinoma the rate of tumour growth (as assessed by changes in tumour size and the biomarker alpha-fetoprotein) and the deterioration of liver function is less in those who have the hepatitis C virus, than in those who do not.


Assuntos
Crescimento e Desenvolvimento/efeitos dos fármacos , Hepatite C/complicações , Neoplasias Hepáticas/tratamento farmacológico , Sorafenibe/farmacologia , Adulto , Idoso , Carcinoma Hepatocelular/tratamento farmacológico , Carcinoma Hepatocelular/fisiopatologia , Feminino , Hepatite C/tratamento farmacológico , Humanos , Fígado/patologia , Testes de Função Hepática/métodos , Testes de Função Hepática/estatística & dados numéricos , Neoplasias Hepáticas/fisiopatologia , Masculino , Pessoa de Meia-Idade , Sorafenibe/uso terapêutico
2.
Clin Cancer Res ; 27(5): 1381-1390, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33303580

RESUMO

PURPOSE: Management of patients with cancer, specifically carboplatin dosing, requires accurate knowledge of glomerular filtration rate (GFR). Direct measurement of GFR is resource limited. Available models for estimated GFR (eGFR) are optimized for patients without cancer and either isotope dilution mass spectrometry (IDMS)- or non-IDMS-standardized creatinine measurements. We present an eGFR model for patients with cancer compatible with both creatinine measurement methods. EXPERIMENTAL DESIGN: GFR measurements, biometrics, and IDMS- or non-IDMS-standardized creatinine values were collected for adult patients from three cancer centers. Using statistical modeling, an IDMS and non-IDMS creatinine-compatible eGFR model (CamGFR v2) was developed. Its performance was compared with that of the existing models Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI), Modification of Diet in Renal Disease (MDRD), Full Age Spectrum (FAS), Lund-Malmö revised, and CamGFR v1, using statistics for bias, precision, accuracy, and clinical robustness. RESULTS: A total of 3,083 IDMS- and 4,612 non-IDMS-standardized creatinine measurements were obtained from 7,240 patients. IDMS-standardized creatinine values were lower than non-IDMS-standardized values in within-center comparisons (13.8% lower in Cambridge; P < 0.0001 and 19.3% lower in Manchester; P < 0.0001), and more consistent between centers. CamGFR v2 was the most accurate [root-mean-squared error for IDMS, 14.97 mL/minute (95% confidence interval, 13.84-16.13) and non-IDMS, 15.74 mL/minute (14.86-16.63)], most clinically robust [proportion with >20% error of calculated carboplatin dose for IDMS, 0.12 (0.09-0.14) and non-IDMS, 0.17 (0.15-0.2)], and least biased [median residual for IDMS, 0.73 mL/minute (-0.68 to 2.2) and non-IDMS, -0.43 mL/minute (-1.48 to 0.91)] eGFR model, particularly when eGFR was larger than 60 ml/minute. CONCLUSIONS: CamGFR v2 can utilize IDMS- and non-IDMS-standardized creatinine measurements and outperforms previous models. CamGFR v2 should be examined prospectively as a practice-changing standard of care for eGFR-based carboplatin dosing.


Assuntos
Creatinina/sangue , Creatinina/normas , Taxa de Filtração Glomerular , Modelos Estatísticos , Neoplasias/epidemiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias/sangue , Neoplasias/patologia , Prognóstico
3.
J Clin Hypertens (Greenwich) ; 22(1): 103-110, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31913578

RESUMO

This study examines the prevalence, awareness, treatment, and control of hypertension in Ulaanbaatar, Mongolia, using both the American Heart Association and conventional thresholds (130/80 and 140/90 mm Hg, respectively). In this randomized cross-sectional study, two-stage cluster sampling was used to obtain a sample of 4515 individuals aged ≥20 years. Hypertension was defined by the use of antihypertensives in the last 2 weeks or a blood pressure at or above the thresholds of 140/90 and 130/80 mm Hg. The mean age of the participants was 41.1 ± 14.0 years and 54.5% were women. Hypertension prevalence was 25.6% (using 140/90 mm Hg) and 46.5% (using 130/80 mm Hg). Prevalence increased with age and below 50 years men were consistently more likely to be hypertensive. Among hypertensive participants, the rates of awareness, treatment, and control were 69.7%, 46.8%, and 24.0% (using 140/90 mm Hg) and 49.1%, 25.8%, and 6.4% (using 130/80 mm Hg, respectively). Men had lower rates of awareness, treatment, and control compared with women, with the most pronounced differences at younger ages. This study shows that awareness, treatment, and control rates in Ulaanbaatar are better than in most low- and middle-income countries but are still suboptimal. The largest "care gap" was in young men where a regulatory requirement for annual workplace blood pressure screening has the potential to enhance care. A major hypertension control program has just been initiated in Ulaanbaatar.


Assuntos
Hipertensão , Adulto , Idoso , Anti-Hipertensivos/uso terapêutico , Conscientização , Pressão Sanguínea/efeitos dos fármacos , Estudos Transversais , Feminino , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Hipertensão/diagnóstico , Hipertensão/tratamento farmacológico , Hipertensão/epidemiologia , Masculino , Pessoa de Meia-Idade , Mongólia/epidemiologia , Prevalência
4.
JNCI Cancer Spectr ; 3(4): pkz068, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31750418

RESUMO

Important oncological management decisions rely on kidney function assessed by serum creatinine-based estimated glomerular filtration rate (eGFR). However, no large-scale multicenter comparisons of methods to determine eGFR in patients with cancer are available. To compare the performance of formulas for eGFR based on routine clinical parameters and serum creatinine not calibrated with isotope dilution mass spectrometry, we studied 3620 patients with cancer and 166 without cancer who had their glomerular filtration rate (GFR) measured with an exogenous nuclear tracer at one of seven clinical centers. The mean measured GFR was 86 mL/min. Accuracy of all models was center dependent, reflecting intercenter variability of isotope dilution mass spectrometry-creatinine measurements. CamGFR was the most accurate model for eGFR (root-mean-squared error 17.3 mL/min) followed by the Chronic Kidney Disease Epidemiology Collaboration model (root-mean-squared error 18.2 mL/min).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA