Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Am J Cardiol ; 93(6): 747-50, 2004 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-15019883

RESUMO

The predictors of troponin release after percutaneous coronary intervention were prospectively assessed in 405 consecutive patients. Troponin release occurred frequently (27%) and was associated with complications during the procedure, including sapheneous vein graft interventions, multistent use, glycoprotein IIb/IIIa use, and a history of hypercholesterolemia.


Assuntos
Angioplastia Coronária com Balão , Infarto do Miocárdio/sangue , Infarto do Miocárdio/terapia , Troponina/sangue , Biomarcadores/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Período Pós-Operatório , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos
2.
J Am Soc Echocardiogr ; 16(2): 147-53, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12574741

RESUMO

The clinical applicability of a method for quantifying pericardial effusion (PE) was studied. The pericardial and cardiac volumes were determined from border tracings of 2-dimensional echocardiograms fitted with 3-dimensional disk models. The PE volume was the difference between pericardial and cardiac volumes. A phantom study included 54 cases with different volumes and viewing geometry showed a correlation coefficient r = 0.98 and an accuracy of +/- 6%. A clinical study included 20 cases showing that the estimated PE volume correlated well with that drained surgically (between 100 mL and 1200 mL): y = 0.81 x + 120 mL; r = 0.91, P <.0001. The percent error, determined by the standard error of the estimate (114 mL) over mean (548 mL), was 20%. Intraobserver variability was 4% and interobserver variability 6%. The 3-dimensional disk method provides a quick and convenient way to quantify PE from 2-dimensional echocardiograms with acceptable accuracy and reproducibility.


Assuntos
Interpretação de Imagem Assistida por Computador , Derrame Pericárdico/diagnóstico por imagem , Volume Cardíaco , Humanos , Variações Dependentes do Observador , Imagens de Fantasmas , Análise de Regressão , Estudos Retrospectivos , Ultrassonografia
4.
Echocardiography ; 23(5): 413-6, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16686628

RESUMO

This case report describes the occurrence of multiple coronary artery fistulae emptying into the left ventricle and includes a small communication into the left atrium. The initial diagnosis of a coronary artery fistula was made by standard and nonstandard transthoracic two-dimensional echocardiogram and Doppler interrogation. Later, multiple coronary fistulae communicating through a sinusoid and draining into the left-sided chambers were confirmed by angiography.


Assuntos
Fístula Arteriovenosa/diagnóstico , Anomalias dos Vasos Coronários/diagnóstico , Fístula Arteriovenosa/complicações , Débito Cardíaco Elevado/diagnóstico , Débito Cardíaco Elevado/etiologia , Angiografia Coronária , Anomalias dos Vasos Coronários/complicações , Ecocardiografia Doppler , Átrios do Coração/anormalidades , Átrios do Coração/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Ventrículos do Coração/anormalidades , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA