Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Phys Rev Lett ; 121(2): 021603, 2018 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-30085729

RESUMO

We measured a considerable increase of the emitted radiation by 120 GeV/c electrons in an axially oriented lead tungstate scintillator crystal, if compared to the case in which the sample was not aligned with the beam direction. This enhancement resulted from the interaction of particles with the strong crystalline electromagnetic field. The data collected at the external lines of the CERN Super Proton Synchrotron were critically compared to Monte Carlo simulations based on the Baier-Katkov quasiclassical method, highlighting a reduction of the scintillator radiation length by a factor of 5 in the case of beam alignment with the [001] crystal axes. The observed effect opens the way to the realization of compact electromagnetic calorimeters or detectors based on oriented scintillator crystals in which the amount of material can be strongly reduced with respect to the state of the art. These devices could have relevant applications in fixed-target experiments, as well as in satellite-borne γ telescopes.

2.
Phys Rev Lett ; 115(2): 025504, 2015 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-26207480

RESUMO

The radiation emitted by 855 MeV electrons via planar channeling and volume reflection in a 30.5-µm-thick bent Si crystal has been investigated at the MAMI (Mainzer Mikrotron) accelerator. The spectral intensity was much more intense than for an equivalent amorphous material, and peaked in the MeV range in the case of channeling radiation. Differently from a straight crystal, also for an incidence angle larger than the Lindhard angle, the spectral intensity remains nearly as high as for channeling. This is due to volume reflection, for which the intensity remains high at a large incidence angle over the whole angular acceptance, which is equal to the bending angle of the crystal. Monte Carlo simulations demonstrated that incoherent scattering significantly influences both the radiation spectrum and intensity, either for channeling or volume reflection. In the latter case, it has been shown that incoherent scattering increases the radiation intensity due to the contribution of volume-captured particles. As a consequence, the experimental spectrum becomes a mixture of channeling and pure volume reflection radiations. These results allow a better understanding of the radiation emitted by electrons subjected to coherent interactions in bent crystals within a still-unexplored energy range, which is relevant for possible applications for innovative and compact x-ray or γ-ray sources.

3.
Phys Rev Lett ; 115(1): 015503, 2015 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-26182106

RESUMO

A bent lithium niobate strip was exposed to a 400-GeV/c proton beam at the external lines of CERN Super Proton Synchrotron to probe its capabilities versus coherent interactions of the particles with the crystal such as channeling and volume reflection. Lithium niobate (LiNbO3) exhibits an interplanar electric field comparable to that of Silicon (Si) and remarkable piezoelectric properties, which could be exploited for the realization of piezo-actuated devices for the control of high-energy particle beams. In contrast to Si and germanium (Ge), LiNbO3 shows an intriguing effect; in spite of a low channeling efficiency (3%), the volume reflection maintains a high deflection efficiency (83%). Such discrepancy was ascribed to the high concentration (10(4) per cm2) of dislocations in our sample, which was obtained from a commercial wafer. Indeed, it has been theoretically shown that a channeling efficiency comparable with that of Si or Ge would be attained with a crystal at low defect concentration (less than ten per cm2). To better understand the role of dislocations on volume reflection, we have worked out computer simulation via dynecharm++ Monte Carlo code to study the effect of dislocations on volume reflection. The results of the simulations agree with experimental records, demonstrating that volume reflection is more robust than channeling in the presence of dislocations.

4.
Phys Rev Lett ; 112(13): 135503, 2014 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-24745437

RESUMO

We report the observation of efficient steering of a 855 MeV electron beam at MAMI (MAinzer MIkrotron) facilities by means of planar channeling and volume reflection in a bent silicon crystal. A 30.5 µm thick plate of (211) oriented Si was bent to cause quasimosaic deformation of the (111) crystallographic planes, which were used for coherent interaction with the electron beam. The experimental results are analogous to those recorded some years ago at energy higher than 100 GeV, which is the only comparable study to date. Monte Carlo simulations demonstrated that rechanneling plays a considerable role in a particle's dynamics and hinders the spoiling of channeled particles. These results allow a better understanding of the dynamics of electrons subject to coherent interactions in a bent silicon crystal in the sub-GeV energy range, which is relevant for realization of innovative x-ray sources based on channeling in periodically bent crystals.

5.
Phys Rev Lett ; 111(25): 255502, 2013 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-24483748

RESUMO

The radiation emitted by 120 GeV/c electrons traversing a single bent crystal under multiple volume reflection orientation is investigated. Multiple volume reflection in one crystal occurs as a charged particle impacts on a bent crystal at several axial channeling angles with respect to a crystal axis. The resulting energy-loss spectrum of electrons was very intense over the full energy range up to the nominal energy of the beam. As compared to the radiation emission by an individual volume reflection, the energy-loss spectrum is more intense and peaks at an energy 3 times greater. Experimental results are compared to a theoretical approach based on the direct integration of the quasiclassical Baier and Katkov formula. In this way, it is possible to determine the mean number of photons emitted by each electron and, thus, to extract the single-photon spectrum, which is broad and intense. The soft part of the radiation spectrum is due to the contribution of coherent interaction between electrons and several reflecting planes intersecting the same crystal axis, whereas the hard part is mainly connected to coherent bremsstrahlung induced by correlated scattering of electrons by atomic strings (string of strings scattering and radiation). The radiation generation by multiple volume reflection takes place over a broad angular range of the incident beam with respect to coherent bremsstrahlung and channeling radiation in straight crystals. Therefore, this type of radiation can be exploited for applications, such as beam dump and collimation devices for future linear colliders.

6.
Phys Rev Lett ; 110(17): 175502, 2013 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-23679744

RESUMO

A graded Si(1-x)Ge(x) crystal has been manufactured for operation with high-energy protons to excite coherent interactions of the particles with the crystal such as channeling and volume reflection. The crystal had the shape of a parallelepiped though its (111) atomic planes were curved at a radius of 25.6 m because of the graded Ge content. The crystal was exposed to a 400 GeV/c proton beam at the external lines of CERN Super Proton Synchrotron to probe its capability to steer high-energy particles. Measured deflection efficiency was 62.0% under planar channeling and 96.0% under volume reflection. Such values are critically compared to their counterparts for a standard bent Si crystal under peer conditions. A Monte Carlo simulation of the dynamics of channeled and volume reflected particles in a graded crystal including the effect of Ge impurities and of lattice dislocations has been carried out. We found that the effect of crystal imperfections spoiled the efficiency of channeling while it negligibly affected the performance of volume reflection. We finally propose the usage of the graded crystal as a primary scatterer to aid halo collimation for the new generation of hadronic machines. As a unique feature, a properly cut graded crystal circumvents the problem of the miscut angle, which is currently a severe limitation for implementation of crystal-assisted collimation.

7.
Phys Rev Lett ; 106(1): 018501, 2011 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-21231775

RESUMO

Strong electric discharges associated with thunderstorms can produce terrestrial gamma-ray flashes (TGFs), i.e., intense bursts of x rays and γ rays lasting a few milliseconds or less. We present in this Letter new TGF timing and spectral data based on the observations of the Italian Space Agency AGILE satellite. We determine that the TGF emission above 10 MeV has a significant power-law spectral component reaching energies up to 100 MeV. These results challenge TGF theoretical models based on runaway electron acceleration. The TGF discharge electric field accelerates particles over the large distances for which maximal voltages of hundreds of megavolts can be established. The combination of huge potentials and large electric fields in TGFs can efficiently accelerate particles in large numbers, and we reconsider here the photon spectrum and the neutron production by photonuclear reactions in the atmosphere.

8.
Phys Rev Lett ; 105(12): 128501, 2010 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-20867680

RESUMO

Terrestrial gamma-ray flashes (TGFs) are very short bursts of high-energy photons and electrons originating in Earth's atmosphere. We present here a localization study of TGFs carried out at gamma-ray energies above 20 MeV based on an innovative event selection method. We use the AGILE satellite Silicon Tracker data that for the first time have been correlated with TGFs detected by the AGILE Mini-Calorimeter. We detect 8 TGFs with gamma-ray photons of energies above 20 MeV localized by the AGILE gamma-ray imager with an accuracy of ∼5-10° at 50 MeV. Remarkably, all TGF-associated gamma rays are compatible with a terrestrial production site closer to the subsatellite point than 400 km. Considering that our gamma rays reach the AGILE satellite at 540 km altitude with limited scattering or attenuation, our measurements provide the first precise direct localization of TGFs from space.

9.
Sci Rep ; 5: 17398, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-26620423

RESUMO

The control of electronic and thermal transport through material interfaces is crucial for numerous micro and nanoelectronics applications and quantum devices. Here we report on the engineering of the electro-thermal properties of semiconductor-superconductor (Sm-S) electronic cooler junctions by a nanoscale insulating tunnel barrier introduced between the Sm and S electrodes. Unexpectedly, such an interface barrier does not increase the junction resistance but strongly reduces the detrimental sub-gap leakage current. These features are key to achieving high cooling power tunnel junction refrigerators, and we demonstrate unparalleled performance in silicon-based Sm-S electron cooler devices with orders of magnitudes improvement in the cooling power in comparison to previous works. By adapting the junctions in strain-engineered silicon coolers we also demonstrate efficient electron temperature reduction from 300 mK to below 100 mK. Investigations on junctions with different interface quality indicate that the previously unexplained sub-gap leakage current is strongly influenced by the Sm-S interface states. These states often dictate the junction electrical resistance through the well-known Fermi level pinning effect and, therefore, superconductivity could be generally used to probe and optimize metal-semiconductor contact behaviour.

10.
Rev Sci Instrum ; 86(4): 045102, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25933892

RESUMO

Silicon/germanium flat/bent crystals are thin devices able to efficiently deflect charged particle GeV-energy beams up to a few hundreds of µrad; moreover, high intensity photons can be efficiently produced in the so-called Multi-Volume Reflection (MVR) and Multiple Volume Reflections in One Crystal (MVROC) conditions. In the last years, the research interest in this field has moved to the dynamic studies of light negative leptons in the low energy range: the possibility to deflect negative particles and to produce high intensity γ sources via the coherent interactions with crystals in the sub-GeV energy range has been proved by the ICE-RAD (Interaction in Crystals for Emission of RADiation) Collaboration at the MAinzer MIkrotron (MAMI, Germany). This paper describes the setup used by the ICE-RAD experiment for the crystals characterization (both in terms of deflection and radiation emission properties): a high precision goniometer is used to align the crystals with the incoming beam, while a silicon based profilometer and an inorganic scintillator reconstruct, respectively, the particle position and the photon spectra after the samples. The crystals manufacturing process and their characterization, the silicon profilometer commissioning at the CERN PS T9 beamline, and the commissioning of the whole setup installed at MAMI are presented.

11.
Med Phys ; 27(11): 2609-16, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11128314

RESUMO

In order to ensure an early diagnosis of breast cancer, an imaging system must fulfil extremely stringent requirements in terms of dynamic range, contrast resolution and spatial resolution. Furthermore, in order to reduce the dose delivered to the patient, a high efficiency of the detector device should be provided. In this paper the SYRMEP/FRONTRAD (SYnchrotron Radiation for MEdical Physics/FRONTier RADiology) mammography project, based on synchroton radiation and a novel solid state pixel detector, is briefly described. Particular relevance is given to the fact that the radiographic image is obtained by means of a scanning technique, which allows the possibility of utilizing a scanning step smaller than the pixel size. With this procedure, a convolution between the real image and the detector point spread function (PSF) is actually acquired: by carefully measuring the detector PSF, it is possible to apply a post-processing procedure (filtered deconvolution), which reconstructs images with enhanced spatial resolution. The image acquisition modality and the deconvolution algorithm are herein described, and some test object images, with spatial resolution enhanced by means of the filtered deconvolution procedure, are presented. As discussed in detail in this paper, this procedure allows us to obtain a spatial resolution determined by the scanning step, rather than by the pixel size.


Assuntos
Neoplasias da Mama/diagnóstico , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Humanos , Mamografia/métodos , Modelos Estatísticos , Radiometria
12.
Med Phys ; 28(8): 1610-9, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11548930

RESUMO

Recently, new imaging modalities based on the detection of weak phase perturbations effects, among which are phase contrast and diffraction imaging, have been developed by several researchers. Due to their high sensitivity to weakly absorbing details, these techniques seem to be very promising for applications in the medical field. On the other hand, digital radiology is undergoing a wide diffusion, and its benefits are presently very well understood. Up to now, however, the strong pixel size constraints associated with phase contrast pattern detection limited the possibility of exploiting the advantages of phase contrast in digital radiology applications. In this paper, an innovative setup capable of removing the pixel size constraints, and thus opening the way to low dose digital phase contrast imaging, is described. Furthermore, we introduce an imaging technique based on the detection of radiation scattered at small angles: the information extracted from the sample is increased at no dose expense. We believe that several radiological fields, mammography being the first important example, may benefit from the herein described innovative imaging techniques.


Assuntos
Diagnóstico por Imagem/métodos , Processamento de Imagem Assistida por Computador , Radiografia/métodos , Humanos , Mamografia/métodos , Imagens de Fantasmas , Espalhamento de Radiação , Software , Raios X
13.
Phys Med Biol ; 42(8): 1565-73, 1997 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-9279906

RESUMO

We present images of a mammographic test object obtained using a linear array silicon pixel detector capable of single-photon counting. The detector pixel size was 200 x 300 microns2 and images were acquired by scanning the test object between the laminar detector and the x-ray source with a scanning step of 100 microns. A molybdenum anode tube was used with two different filtrations: 2 mm aluminium and 25 microns molybdenum. Conventional film-screen images were also obtained in order to compare spatial and contrast resolution. In our digital images it is possible to recognize low-contrast details having dimensions smaller than or equal to the dimensions of details visible by means of a clinical mammographic unit. The detection of microcalcifications smaller than 150 microns was possible only when using the Mo filtration. However a copper wire of 50 microns diameter was detectable when embedded in a simulated tissue. We discuss in detail the mean glandular doses (MGDs) delivered during the image acquisition. The MGDs necessary to obtain good-quality images are always smaller than at a conventional mammographic unit. Since MGDs depend on the x-ray spectrum, the dose reduction becomes larger when the applied spectrum is harder than in film-screen acquisition (Al filtration and 35 kVp).


Assuntos
Mamografia/instrumentação , Mamografia/métodos , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador , Feminino , Humanos , Molibdênio , Fótons , Doses de Radiação , Sensibilidade e Especificidade , Silício
14.
Phys Med Biol ; 43(10): 2845-52, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9814522

RESUMO

Phase contrast x-ray imaging is a powerful technique for the detection of low-contrast details in weakly absorbing objects. This method is of possible relevance in the field of diagnostic radiology. In fact, imaging low-contrast details within soft tissue does not give satisfactory results in conventional x-ray absorption radiology, mammography being a typical example. Nevertheless, up to now all applications of the phase contrast technique, carried out on thin samples, have required radiation doses substantially higher than those delivered in conventional radiological examinations. To demonstrate the applicability of the method to mammography we produced phase contrast images of objects a few centimetres thick while delivering radiation doses lower than or comparable to doses needed in standard mammographic examinations (typically approximately 1 mGy mean glandular dose (MGD)). We show images of a custom mammographic phantom and of two specimens of human breast tissue obtained at the SYRMEP bending magnet beamline at Elettra, the Trieste synchrotron radiation facility. The introduction of an intensifier screen enabled us to obtain phase contrast images of these thick samples with radiation doses comparable to those used in mammography. Low absorbing details such as 50 microm thick nylon wires or thin calcium deposits (approximately 50 microm) within breast tissue, invisible with conventional techniques, are detected by means of the proposed method. We also find that the use of a bending magnet radiation source relaxes the previously reported requirements on source size for phase contrast imaging. Finally, the consistency of the results has been checked by theoretical simulations carried out for the purposes of this experiment.


Assuntos
Diagnóstico por Imagem/métodos , Mamografia/métodos , Biópsia , Diagnóstico por Imagem/instrumentação , Humanos , Microscopia de Contraste de Fase , Radiografia/métodos , Síncrotrons , Raios X
15.
Science ; 327(5966): 663-5, 2010 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-20044540

RESUMO

Pulsars are known to power winds of relativistic particles that can produce bright nebulae by interacting with the surrounding medium. These pulsar wind nebulae are observed by their radio, optical, and x-ray emissions, and in some cases also at TeV (teraelectron volt) energies, but the lack of information in the gamma-ray band precludes drawing a comprehensive multiwavelength picture of their phenomenology and emission mechanisms. Using data from the AGILE satellite, we detected the Vela pulsar wind nebula in the energy range from 100 MeV to 3 GeV. This result constrains the particle population responsible for the GeV emission and establishes a class of gamma-ray emitters that could account for a fraction of the unidentified galactic gamma-ray sources.

16.
Phys Rev Lett ; 102(8): 084801, 2009 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-19257744

RESUMO

The interactions of 400 GeV protons with different sequences of bent silicon crystals have been investigated at the H8 beam line of the CERN Super Proton Synchrotron. The multiple volume reflection of the proton beam has been studied in detail on a five-crystal reflector measuring an angular beam deflection theta = 52.96 +/- 0.14 microrad. The efficiency was found larger than 80% for an angular acceptance at the reflector entrance of 70 microrad, with a maximal efficiency value of epsilon = 0.90 +/- 0.01 +/- 0.03.

17.
Phys Rev Lett ; 101(23): 234801, 2008 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-19113559

RESUMO

The trend of volume reflection parameters (deflection angle and efficiency) in a bent (110) silicon crystal has been investigated as a function of the crystal curvature with 400 GeV/c protons on the H8 beam line at the CERN Super Proton Synchrotron. This Letter describes the analysis performed at six different curvatures showing that the optimal radius for volume reflection is approximately 10 times greater than the critical radius for channeling. A strong scattering of the beam by the planar potential is also observed for a bend radius close to the critical one.

18.
Radiology ; 208(3): 709-15, 1998 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-9722850

RESUMO

A linear-array, silicon pixel detector, capable of counting single photons, was applied to mammography by using a synchrotron radiation beam. Images were obtained of both a mammographic phantom and a breast-tissue sample. The phantom image was acquired with a mean glandular dose of 0.32 mGy. This detector combined with a synchrotron radiation beam allows acquisition of high-contrast, low-dose images of soft tissues.


Assuntos
Mama/efeitos da radiação , Transferência Linear de Energia , Mamografia/instrumentação , Imagens de Fantasmas , Radiometria/instrumentação , Silício , Feminino , Humanos , Fótons , Doses de Radiação , Intensificação de Imagem Radiográfica/instrumentação
19.
Radiology ; 215(1): 286-93, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10751500

RESUMO

The authors evaluated the effect on mammographic examinations of the use of synchrotron radiation to detect phase-perturbation effects, which are higher than absorption effects for soft tissue in the energy range of 15-25 keV. Detection of phase-perturbation effects was possible because of the high degree of coherence of synchrotron radiation sources. Synchrotron radiation images were obtained of a mammographic phantom and in vitro breast tissue specimens and compared with conventional mammographic studies. On the basis of grades assigned by three reviewers, image quality of the former was considerably higher, and the delivered dose was fully compatible.


Assuntos
Mamografia/métodos , Síncrotrons , Absorção , Mama/efeitos da radiação , Feminino , Humanos , Mamografia/instrumentação , Variações Dependentes do Observador , Imagens de Fantasmas , Doses de Radiação , Intensificação de Imagem Radiográfica/instrumentação , Intensificação de Imagem Radiográfica/métodos , Espalhamento de Radiação , Fatores de Tempo , Difração de Raios X/instrumentação , Filme para Raios X , Ecrans Intensificadores para Raios X , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA