1.
J Appl Clin Med Phys ; 25(1): e14235, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38059633

RESUMO

PURPOSE: The purpose of this investigation was to assess the effect of visceral adipose tissue volume (VA) on reader efficacy in diagnosing and characterizing small bowel Crohn's disease using lower exposure CT enterography (CTE). Secondarily, we investigated the effect of lower exposure and VA on reader diagnostic confidence. METHODS: Prospective paired investigation of 256 CTE, 129 with Crohn's disease, were reconstructed at 100% and simulated 50% and 30% exposure. The senior author provided the disease classification for the 129 patients with Crohn's disease. Patient VA was measured, and exams were evaluated by six readers for presence or absence of Crohn's disease and phenotype using a 0-10-point scale. Logistic regression models assessed the effect of VA on sensitivity and specificity. RESULTS: The effect of VA on sensitivity was significantly reduced at 30% exposure (odds radio [OR]: 1.00) compared to 100% exposure (OR: 1.12) (p = 0.048). There was no statistically significant difference among the exposures with respect to the effect of visceral fat on specificity (p = 0.159). The study readers' probability of agreement with the senior author on disease classification was 60%, 56%, and 53% at 100%, 50%, and 30% exposure, respectively (p = 0.004). When detecting low severity Crohn's disease, readers' mean sensitivity was 83%, 75%, and 74% at 100%, 50%, and 30% exposure, respectively (p = 0.002). In low severity disease, sensitivity also tended to increase as visceral fat increased (ORs per 1000 cm3 increase in visceral fat: 1.32, 1.31, and 1.18, p = 0.010, 0.016, and 0.100, at 100%, 50%, and 30% exposure). CONCLUSIONS: While the interaction is complex, VA plays a role in detecting and characterizing small bowel Crohn's disease when exposure is altered, particularly in low severity disease.


Assuntos
Doença de Crohn , Enteropatias , Humanos , Doença de Crohn/diagnóstico por imagem , Gordura Intra-Abdominal/diagnóstico por imagem , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos
2.
Skeletal Radiol ; 50(4): 693-703, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32948903

RESUMO

OBJECTIVE: To evaluate the feasibility of producing 2-dimensional (2D) virtual noncontrast images and 3-dimensional (3D) bone models from dual-energy computed tomography (DECT) arthrograms and to determine whether this is best accomplished using 190 keV virtual monoenergetic images (VMI) or virtual unenhanced (VUE) images. MATERIALS AND METHODS: VMI and VUE images were retrospectively reconstructed from patients with internal derangement of the shoulder or knee joint who underwent DECT arthrography between September 2017 and August 2019. A region of interest was placed in the area of brightest contrast, and the mean attenuation (in Hounsfield units [HUs]) was recorded. Two blinded musculoskeletal radiologists qualitatively graded the 2D images and 3D models using scores ranging from 0 to 3 (0 considered optimal). RESULTS: Twenty-six patients (mean age ± SD, 57.5 ± 16.8 years; 6 women) were included in the study. The contrast attenuation on VUE images (overall mean ± SD, 10.5 ± 16.4 HU; knee, 19.3 ± 10.7 HU; shoulder, 5.0 ± 17.2 HU) was significantly lower (p < 0.001 for all comparisons) than on VMI (overall mean ± SD, 107.7 ± 43.8 HU; knee, 104.6 ± 31.1 HU; shoulder, 109.6 ± 51.0 HU). The proportion of cases with optimal scores (0 or 1) was significantly higher with VUE than with VMI for both 2D and 3D images (p < 0.001). CONCLUSIONS: DECT arthrography can be used to produce 2D virtual noncontrast images and to generate 3D bone models. The VUE technique is superior to VMI in producing virtual noncontrast images.


Assuntos
Artrografia , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Estudos de Viabilidade , Feminino , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X
3.
Skeletal Radiol ; 50(5): 955-965, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33037447

RESUMO

OBJECTIVE: To determine whether a simulated low-dose metal artifact reduction (MAR) CT technique is comparable with a clinical dose MAR technique for shoulder arthroplasty evaluation. MATERIALS AND METHODS: Two shoulder arthroplasties in cadavers and 25 shoulder arthroplasties in patients were scanned using a clinical dose (140 kVp, 300 qrmAs); cadavers were also scanned at half dose (140 kVp, 150 qrmAs). Images were reconstructed using a MAR CT algorithm at full dose and a noise-insertion algorithm simulating 50% dose reduction. For the actual and simulated half-dose cadaver scans, differences in SD for regions of interest were assessed, and streak artifact near the arthroplasty was graded by 3 blinded readers. Simulated half-dose scans were compared with full-dose scans in patients by measuring differences in implant position and by comparing readers' grades of periprosthetic osteolysis and muscle atrophy. RESULTS: The mean difference in SD between actual and simulated half-dose methods was 2.42 HU (95% CI [1.4, 3.4]). No differences in streak artifact grades were seen in 13/18 (72.2%) comparisons in cadavers. In patients, differences in implant position measurements were within 1° or 1 mm in 149/150 (99.3%) measurements. The inter-reader agreement rates were nearly identical when readers were using full-dose (77.3% [232/300] for osteolysis and 76.9% [173/225] for muscle atrophy) and simulated half-dose (76.7% [920/1200] for osteolysis and 74.0% [666/900] for muscle atrophy) scans. CONCLUSION: A simulated half-dose MAR CT technique is comparable both quantitatively and qualitatively with a standard-dose technique for shoulder arthroplasty evaluation, demonstrating that this technique could be used to reduce dose in arthroplasty imaging.


Assuntos
Artefatos , Tomografia Computadorizada por Raios X , Algoritmos , Artroplastia , Cadáver , Humanos , Metais , Imagens de Fantasmas
4.
J Appl Clin Med Phys ; 22(2): 138-144, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33368998

RESUMO

PURPOSE: The purpose of this study was to assess the effect of obesity and iterative reconstruction on the ability to reduce exposure by studying the accuracy for detection of low-contrast low-attenuation (LCLA) liver lesions on computed tomography (CT) using a phantom model. METHODS: A phantom with four unique LCLA liver lesions (5- to 15-mm spheres, -24 to -6 HU relative to 90-HU background) was scanned without ("thin" phantom) and with ("obese" phantom) a 5-cm thick fat-attenuation ring at 150 mAs (thin phantom) and 450 mAs (obese phantom) standard exposures and at 33% and 67% exposure reductions. Images were reconstructed using standard filtered back projection (FBP) and with iterative reconstruction (Adaptive Model-Based Iterative Reconstruction strength 3, ADMIRE). A noninferiority analysis of lesion detection was performed. RESULTS: Mean area under the curve (AUC) values for lesion detection were significantly higher for the thin phantom than for the obese phantom regardless of exposure level (P < 0.05) for both FBP and ADMIRE. At 33% exposure reduction, AUC was noninferior for both FBP and ADMIRE strength 3 (P < 0.0001). At 67% exposure reduction, AUC remained noninferior for the thin phantom (P < 0.0035), but was no longer noninferior for the obese phantom (P ≥ 0.7353). There were no statistically significant differences in AUC between FBP and ADMIRE at any exposure level for either phantom. CONCLUSIONS: Accuracy for lesion detection was not only significantly lower in the obese phantom at all relative exposures, but detection accuracy decreased sooner while reducing the exposure in the obese phantom. There was no significant difference in lesion detection between FBP and ADMIRE at equivalent exposure levels for either phantom.


Assuntos
Algoritmos , Neoplasias Hepáticas , Humanos , Obesidade , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador
5.
Emerg Radiol ; 28(1): 103-117, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32483665

RESUMO

Dual energy computed tomography (DECT), also known as spectral CT, refers to advanced CT technology that separately acquires high and low energy X-ray data to enable material characterization applications for substances that exhibit different energy-dependent x-ray absorption behavior. DECT supports a variety of post-processing applications that add value in routine clinical CT imaging, including material selective and virtual non-contrast images using two- and three-material decomposition algorithms, virtual monoenergetic imaging, and other material characterization techniques. Following a review of acquisition and post-processing techniques, we present a case-based approach to highlight the added value of DECT in common clinical scenarios. These scenarios include improved lesion detection, improved lesion characterization, improved ease of interpretation, improved prognostication, inherently more robust imaging protocols to account for unexpected pathology or suboptimal contrast opacification, length of stay reduction, reduced utilization by avoiding unnecessary follow-up examinations, and radiation dose reduction. A brief discussion of post-processing workflow approaches, challenges, and solutions is also included.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Meios de Contraste , Humanos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador
6.
AJR Am J Roentgenol ; 215(2): 425-432, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32374668

RESUMO

OBJECTIVE. The purpose of this study was to compare a combined dual-energy CT (DECT) and single-energy CT (SECT) metal artifact reduction technique with a SECT metal artifact reduction technique for detecting lesions near an arthroplasty in a phantom model. MATERIALS AND METHODS. Two CT phantoms with a cobalt chromium sphere attached to a titanium rod, simulating an arthroplasty, within a background of soft-tissue attenuation containing spherical lesions (range, 10-20 mm) around the head and stem of different attenuations from the background (range of attenuation, 10-70 HU) were scanned with a single CT scanner individually (unilateral) and together (bilateral) with the following three dose-equivalent techniques: the currently used clinical protocol (140 kVp, 300 Reference mAs); 100 kVp; and DECT (100 kVp and 150 kVp with a tin filter). Three radiologists reviewed the datasets to identify lesions. Nonparametric AUC was estimated for each reader with each technique. Multireader ANOVA was performed to compare AUCs. Multiple-variable logistic regression analysis was used to identify factors affecting sensitivity and specificity. RESULTS. Accuracy was lower (p < 0.001) for the DECT 130-keV technique than for the 100-, 70-, and 140-kVp techniques. Sensitivity was higher with unilateral arthroplasties (p = 0.037), with greater contrast differences from background (p < 0.001), and with the SECT 100-kVp technique versus other techniques (p < 0.001). The difference in specificities of modalities was not statistically significant (p = 0.148). CONCLUSION. Combining DECT and SECT techniques does not provide additional benefits for lesion detection as opposed to using SECT alone.


Assuntos
Artefatos , Ligas de Cromo , Prótese Articular , Titânio , Tomografia Computadorizada por Raios X/métodos , Artroplastia , Imagens de Fantasmas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton
7.
AJR Am J Roentgenol ; 214(6): 1199-1205, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32286868

RESUMO

OBJECTIVE. The purpose of this study was to assess if dual-source dual-energy CT (DS-DECT) can be used with lower radiation doses and contrast material volumes than single-energy CT (SECT) in children and young adults. MATERIALS AND METHODS. This retrospective study included 85 consecutive children and young adults (age range, 1 month old to 19 years old; 81 male, 70 female) who underwent contrast-enhanced DS-DECT of the chest (n = 41) or the abdomen and pelvis (n = 44) on second- or third-generation dual-source CT scanners (Somatom Flash or Force, Siemens Healthineers) for clinically indicated reasons. We included 66 age-, sex-, body region-, and weight-matched patients who underwent SECT on the same scanner. Patients were scanned with either SECT (with automatic exposure control using both CARE kV [Siemens Healthineers] and CARE Dose 4D [Siemens Healthineers]) or DS-DECT (with CARE Dose 4D). Two pediatric radiologists assessed clinical indications, radiologic findings, image quality, and any study limitations (noise or artifacts). Patient demographics (age, sex, weight), scan parameters (tube voltage, tube current-time product, pitch, section thickness), CT dose descriptors (volume CT dose index, dose-length product, size-specific dose estimate [SSDE]), and contrast material volume were recorded. Descriptive statistics, paired t test, and Cohen kappa test were performed. RESULTS. Mean patient ages and weights ± SD in DS-DECT (10 ± 6 years old, 38 ± 23 kg) and SECT (11 ± 7 years old, 43 ± 29 kg) groups were not significantly different (p > 0.05). Respective SSDEs for chest DS-DECT (4.0 ± 2.1 mGy), chest SECT (6.1 ± 4.4 mGy), abdomen-pelvis DS-DECT (5.0 ± 5.0 mGy), and abdomen-pelvis SECT (8.3 ± 4.0 mGy) were significantly different (p = 0.003-0.005). Contrast material volume for DS-DECT examinations was 19-22% lower compared with the weight- and body region-matched scans obtained with SECT. Image quality of DECT was acceptable in all patients. CONCLUSION. In children and young adults, chest and abdomen-pelvis DS-DECT enables substantial radiation dose and contrast volume reductions compared with weight- and region-matched SECT.


Assuntos
Meios de Contraste/administração & dosagem , Doses de Radiação , Proteção Radiológica/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos , Adulto Jovem
8.
J Comput Assist Tomogr ; 44(2): 223-229, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32195800

RESUMO

OBJECTIVES: This study aimed to assess if dual-energy computed tomography (DECT) quantitative analysis and radiomics can differentiate normal liver, hepatic steatosis, and cirrhosis. MATERIALS AND METHODS: Our retrospective study included 75 adult patients (mean age, 54 ± 16 years) who underwent contrast-enhanced, dual-source DECT of the abdomen. We used Dual-Energy Tumor Analysis prototype for semiautomatic liver segmentation and DECT and radiomic features. The data were analyzed with multiple logistic regression and random forest classifier to determine area under the curve (AUC). RESULTS: Iodine quantification (AUC, 0.95) and radiomic features (AUC, 0.97) differentiate between healthy and abnormal liver. Combined fat ratio percent and mean mixed CT values (AUC, 0.99) were the strongest differentiators of healthy and steatotic liver. The most accurate differentiating parameters of normal liver and cirrhosis were a combination of first-order statistics (90th percentile), gray-level run length matrix (short-run low gray-level emphasis), and gray-level size zone matrix (gray-level nonuniformity normalized; AUC, 0.99). CONCLUSION: Dual-energy computed tomography iodine quantification and radiomics accurately differentiate normal liver from steatosis and cirrhosis from single-section analyses.


Assuntos
Fígado Gorduroso/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Diagnóstico Diferencial , Estudos de Avaliação como Assunto , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estudos Retrospectivos
9.
AJR Am J Roentgenol ; 210(3): 593-600, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29231758

RESUMO

OBJECTIVE: The objective of this study was to compare reader accuracy detecting lesions near hardware in a CT phantom model at different radiation exposures using an advanced metal artifact reduction (MAR) algorithm and standard filtered back projection (FBP) techniques and to determine if radiation exposure could be decreased using MAR without compromising lesion detectability. MATERIALS AND METHODS: A CT phantom manufactured with spherical lesions of various sizes (10-20 mm) and attenuations (20-50 HU) embedded around cobalt-chromium spheres attached to titanium rods, simulating an arthroplasty, was scanned on a single CT scanner (FLASH, Siemens Healthcare) at 140 kVp and 0.6-mm collimation using clinical-dose (300 Quality Reference mAs [Siemens Healthcare]), low-dose (150 Quality Reference mAs), and high-dose (600 Quality Reference mAs) protocols. Images reconstructed with iterative MAR, advanced modeled iterative reconstruction (ADMIRE), and FBP with identical parameters were anonymized and independently reviewed by three radiologists. Accuracies for detecting lesions, measured as AUC, sensitivity, and specificity, were compared. RESULTS: Accuracy using MAR was significantly higher than that using FBP at all exposures (p values ranged from < 0.001 to 0.021). Sensitivity was also higher for MAR than for FBP at all exposures. Specificity was very high for both reconstruction techniques at all exposures with no significant differences. Accuracy of low-dose MAR was higher than and not inferior to standard-dose and high-dose FBP. MAR was significantly more sensitive than FBP in detecting smaller lesions (p = 0.021) and lesions near high streak artifact (p < 0.001). CONCLUSION: MAR improves reader accuracy to detect lesions near hardware and allows significant reductions in radiation exposure without compromising accuracy compared with FBP in a CT phantom model.


Assuntos
Artefatos , Metais , Próteses e Implantes , Doses de Radiação , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos , Variações Dependentes do Observador , Imagens de Fantasmas
10.
J Comput Assist Tomogr ; 42(4): 623-629, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29613990

RESUMO

PURPOSE: The purpose of this study was to compare quantitative and qualitative measures of aortic, cardiac, and respiratory motion artifact between high-pitch dual-source (DS) and single-source (SS) computed tomography pulmonary angiography (CTPA) protocols. METHODS: This institutional review board-approved, Health Insurance Portability and Accountability Act-compliant study retrospectively reviewed 80 non-electrocardiogram-gated CTPA examinations acquired with a second-generation DS system at 100 kVp following 50 mL iodinated contrast injection - 40 consecutive SS and 40 consecutive DS studies. Quantitative measures of aortic, left ventricular, and diaphragmatic motion were recorded as the maximal excursion of a structure's "double image," and 3 independent readers performed qualitative motion assessments. Pulmonary arterial contrast enhancement, image noise, and radiation dose metrics were recorded. Statistical analyses were performed with 1-way analysis of variance and Fisher exact test. RESULTS: Dual source outperformed SS technique in both quantitative and qualitative measures of motion. Mean distances between motion-artifact double images were reduced with DS protocol at each location (all P ≤ 0.004), and DS examinations were more likely to receive an assessment of no motion in all locations (all P < 0.0001). The DS protocol demonstrated increases in contrast enhancement, although increased image noise resulted in lower enhancement to noise ratio. Mean radiation dose was 60% lower using the DS protocol. CONCLUSION: High-pitch DS CTPA significantly reduces artifacts resulting from ascending aortic, cardiac, and diaphragmatic motion.


Assuntos
Artefatos , Angiografia por Tomografia Computadorizada/métodos , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Estudos Retrospectivos , Razão Sinal-Ruído , Adulto Jovem
11.
Eur Radiol ; 27(8): 3283-3289, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28091793

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the impact of attenuation-based kilovoltage (kV) pair selection in dual source dual energy (DSDE)-pulmonary embolism (PE) protocol examinations on radiation dose savings and image quality. METHODS: A prospective study was carried out on 118 patients with suspected PE. In patients in whom attenuation-based kV pair selection selected the 80/140Sn kV pair, the pre-scan 100/140Sn CTDIvol (computed tomography dose index volume) values were compared with the pre-scan 80/140Sn CTDIvol values. Subjective and objective image quality parameters were assessed. RESULTS: Attenuation-based kV pair selection switched to the 80/140Sn kV pair ("switched" cohort) in 63 out of 118 patients (53%). The mean 100/140Sn pre-scan CTDIvol was 8.8 mGy, while the mean 80/140Sn pre-scan CTDIvol was 7.5 mGy. The average estimated dose reduction for the "switched" cohort was 1.3 mGy (95% CI 1.2, 1.4; p < 0.001), representing a 15% reduction in dose. After adjusting for patient weight, mean attenuation was significantly higher in the "switched" vs. "non-switched" cohorts in all five pulmonary arteries and in all lobes on iodine maps. CONCLUSIONS: This study demonstrates that attenuation-based kV pair selection in DSDE examination is feasible and can offer radiation dose reduction without compromising image quality. KEY POINTS: • Attenuation-based kV pair selection in dual energy examination is feasible. • It can offer radiation dose reduction to approximately 50% of patients. • Approximate 15% reduction in radiation dose was achieved using this technique. • The image quality is not compromised by use of attenuation-based kV pair selection.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia por Tomografia Computadorizada/normas , Embolia Pulmonar/diagnóstico por imagem , Doses de Radiação , Radiografia Torácica/métodos , Radiografia Torácica/normas , Adulto , Idoso , Peso Corporal , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Artéria Pulmonar/diagnóstico por imagem
12.
Radiology ; 280(2): 475-82, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26937709

RESUMO

Purpose To assess image noise, contrast-to-noise ratio (CNR) and detectability of low-contrast, low-attenuation liver lesions in a semianthropomorphic phantom by using either a discrete circuit (DC) detector and filtered back projection (FBP) or an integrated circuit (IC) detector and iterative reconstruction (IR) with changes in radiation exposure and phantom size. Materials and Methods An anthropomorphic phantom without or with a 5-cm-thick fat-mimicking ring (widths, 30 and 40 cm) containing liver inserts with four spherical lesions was scanned with five exposure settings on each of two computed tomography scanners, one equipped with a DC detector and the other with an IC detector. Images from the DC and IC detector scanners were reconstructed with FBP and IR, respectively. Image noise and lesion CNR were measured. Four radiologists evaluated lesion presence on a five-point diagnostic confidence scale. Data analyses included receiver operating characteristic (ROC) curve analysis and noninferiority analysis. Results The combination of IC and IR significantly reduced image noise (P < .001) (with the greatest reduction in the 40-cm phantom and at lower exposures) and improved lesion CNR (P < .001). There was no significant difference in area under the ROC curve between detector-reconstruction combinations at fixed exposure for either phantom. Reader accuracy with IC-IR was noninferior at 50% (100 mAs [effective]) and 25% (300 mAs [effective]) exposure reduction for the 30- and 40-cm phantoms, respectively (adjusted P < .001 and .04 respectively). IC-IR improved readers' confidence in the presence of a lesion (P = .029) independent of phantom size or exposure level. Conclusion IC-IR improved objective image quality and lesion detection confidence but did not result in superior diagnostic accuracy when compared with DC-FBP. Moderate exposure reductions maintained comparable diagnostic accuracy for both detector-reconstruction combinations. Lesion detection in the 40-cm phantom was inferior at smaller exposure reduction than in the 30-cm phantom. (©) RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Artefatos , Fígado/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Imagens de Fantasmas , Exposição à Radiação/estatística & dados numéricos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Humanos , Tomografia Computadorizada Multidetectores/estatística & dados numéricos , Doses de Radiação , Razão Sinal-Ruído
13.
Radiology ; 280(2): 436-45, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27077382

RESUMO

Purpose To compare the diagnostic accuracy and image quality of computed tomographic (CT) enterographic images obtained at half dose and reconstructed with filtered back projection (FBP) and sinogram-affirmed iterative reconstruction (SAFIRE) with those of full-dose CT enterographic images reconstructed with FBP for active inflammatory terminal or neoterminal ileal Crohn disease. Materials and Methods This retrospective study was compliant with HIPAA and approved by the institutional review board. The requirement to obtain informed consent was waived. Ninety subjects (45 with active terminal ileal Crohn disease and 45 without Crohn disease) underwent CT enterography with a dual-source CT unit. The reference standard for confirmation of active Crohn disease was active terminal ileal Crohn disease based on ileocolonoscopy or established Crohn disease and imaging features of active terminal ileal Crohn disease. Data from both tubes were reconstructed with FBP (100% exposure); data from the primary tube (50% exposure) were reconstructed with FBP and SAFIRE strengths 3 and 4, yielding four datasets per CT enterographic examination. The mean volume CT dose index (CTDIvol) and size-specific dose estimate (SSDE) at full dose were 13.1 mGy (median, 7.36 mGy) and 15.9 mGy (median, 13.06 mGy), respectively, and those at half dose were 6.55 mGy (median, 3.68 mGy) and 7.95 mGy (median, 6.5 mGy). Images were subjectively evaluated by eight radiologists for quality and diagnostic confidence for Crohn disease. Areas under the receiver operating characteristic curves (AUCs) were estimated, and the multireader, multicase analysis of variance method was used to compare reconstruction methods on the basis of a noninferiority margin of 0.05. Results The mean AUCs with half-dose scans (FBP, 0.908; SAFIRE 3, 0.935; SAFIRE 4, 0.924) were noninferior to the mean AUC with full-dose FBP scans (0.908; P < .003). The proportion of images with inferior quality was significantly higher with all half-dose reconstructions than with full-dose FBP (mean proportion: 0.117 for half-dose FBP, 0.054 for half-dose SAFIRE 3, 0.054 for half-dose SAFIRE 4, and 0.017 for full-dose FBP; P < .001). Conclusion The diagnostic accuracy of half-dose CT enterography with FBP and SAFIRE is statistically noninferior to that of full-dose CT enterography for active inflammatory terminal ileal Crohn disease, despite an inferior subjective image quality. (©) RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Doença de Crohn/diagnóstico por imagem , Ileíte/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Doença de Crohn/complicações , Feminino , Trato Gastrointestinal/diagnóstico por imagem , Humanos , Ileíte/complicações , Íleo/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
14.
AJR Am J Roentgenol ; 207(2): 378-85, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27186794

RESUMO

OBJECTIVE: The purpose of this study was to compare iterative metal artifact reduction (iMAR), a new single-energy metal artifact reduction technique, with filtered back projection (FBP) in terms of attenuation values, qualitative image quality, and streak artifacts near shoulder and hip arthroplasties and observer ability with these techniques to detect pathologic lesions near an arthroplasty in a phantom model. MATERIALS AND METHODS: Preoperative and postoperative CT scans of 40 shoulder and 21 hip arthroplasties were reviewed. All postoperative scans were obtained using the same technique (140 kVp, 300 quality reference mAs, 128 × 0.6 mm detector collimation) on one of three CT scanners and reconstructed with FBP and iMAR. The attenuation differences in bones and soft tissues between preoperative and postoperative scans at the same location were compared; image quality and streak artifact for both reconstructions were qualitatively graded by two blinded readers. Observer ability and confidence to detect lesions near an arthroplasty in a phantom model were graded. RESULTS: For both readers, iMAR had more accurate attenuation values (p < 0.001), qualitatively better image quality (p < 0.001), and less streak artifact (p < 0.001) in all locations near arthroplasties compared with FBP. Both readers detected more lesions (p ≤ 0.04) with higher confidence (p ≤ 0.01) with iMAR than with FBP in the phantom model. CONCLUSION: The iMAR technique provided more accurate attenuation values, better image quality, and less streak artifact near hip and shoulder arthroplasties than FBP; iMAR also increased observer ability and confidence to detect pathologic lesions near arthroplasties in a phantom model.


Assuntos
Artroplastia de Quadril , Artroplastia do Ombro , Prótese de Quadril , Prótese de Ombro , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Feminino , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
15.
AJR Am J Roentgenol ; 205(3): 592-8, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26295647

RESUMO

OBJECTIVE: The purposes of this study were to determine the differences in estimated volumetric CT dose index (CTDIvol) obtained from the topogram before abdominal and pelvic MDCT in adult and pediatric patients using a scan type-based algorithm for selecting kilovoltage (CARE kV) and a fixed and a weight-based Quality Reference mAs for selecting tube (gmAs) current-exposure time product, in comparison with standard protocols, and to determine the bias and variability of estimated CTDIvol vis-à-vis actual CTDIvol using the standard protocols. MATERIALS AND METHODS: During a 14-month period, 312 adult and pediatric patients referred for abdominal and pelvic MDCT were included in the study. For all patients, the estimated CTDIvol based on the topogram was recorded: protocol A, CARE kV on and 210 gmAs; protocol B, CARE kV on and 1 gmAs times patient weight (in pounds); and protocol C (standard protocol), CARE kV off, 120 kVp, and 1 gmAs times patient weight (in pounds). For the pediatric patients, estimated CTDIvol for the standard protocol D was calculated with 120 kVp and 150 gmAs. All patients were scanned with the standard protocols, and the actual CTDIvol was recorded. Linear regression models compared the CTDIvol of the three protocols in adults and the fourth for children. The estimated and actual CTDIvol were compared using a t test. RESULTS: Protocol B yielded the lowest estimated CTDIvol (mean, 13.2 mGy for adults and 3.5 mGy for pediatric patients). The estimated CTDIvol overestimated the actual CTDIvol by, on average, 1.07 mGy for adults and 0.3 mGy for children. CONCLUSION: CARE kV appears to reduce estimated CTDIvol vis-à-vis standard protocols only when a weight-based gmAs is used. Prescan estimated CTDIvol calculations appear to generally overestimate actual CTDIvol.


Assuntos
Tomografia Computadorizada Multidetectores/instrumentação , Doses de Radiação , Adolescente , Adulto , Algoritmos , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Radiografia Abdominal
16.
Radiology ; 272(1): 154-63, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24620913

RESUMO

PURPOSE: To measure the effect of reduced radiation exposure on low-contrast low-attenuation liver lesion detection in an anthropomorphic abdominal phantom by using filtered back projection (FBP) and sinogram-affirmed iterative reconstruction. MATERIALS AND METHODS: Eighteen radiologists blinded to phantom and study design interpreted randomized image data sets that contained 36 spherical simulated liver lesions of three sizes and three attenuation differences (5-mm diameter: 12, 18, and 24 HU less than the 90-HU background attenuation of the simulated liver insert; 10- and 15-mm diameter: 6, 12, and 18 HU less than the 90-HU background attenuation) scanned with four discrete exposure settings and reconstructed by using FBP and sinogram-affirmed iterative reconstruction. Response assessment included region-level lesion presence or absence on a five-point diagnostic confidence scale. Statistical evaluation included multireader multicase receiver operating characteristic curve analysis, with nonparametric methods and noninferiority analysis at a margin of -0.10. RESULTS: Pooled accuracy at 75% exposure for both FBP and sinogram-affirmed iterative reconstruction was noninferior to 100% exposure (P = .002 and P < .001, respectively). Subsequent exposure reductions resulted in a significant decrease in accuracy. When the smallest (5-mm-diameter) lesions were excluded from analysis, sinogram-affirmed iterative reconstruction was superior to FBP at 100% exposure (P = .011), and sinogram-affirmed iterative reconstruction at 25% and 50% exposure reduction was noninferior to FBP at 100% exposure (P ≤ .013). Reader confidence was greater with sinogram-affirmed iterative reconstruction than with FBP for 10- and 15-mm lesions (2.94 vs 2.76 and 3.62 vs 3.52, respectively). CONCLUSION: In this low-contrast low-attenuation liver lesion model, a 25% exposure reduction maintained noninferior diagnostic accuracy. However, detection was inferior with each subsequent exposure reduction, regardless of reconstruction method. Sinogram-affirmed iterative reconstruction and FBP performed equally well at modest exposure reduction (25%-50%). Readers had higher confidence levels with sinogram-affirmed iterative reconstruction for the 10- and 15-mm lesions.


Assuntos
Hepatopatias/diagnóstico por imagem , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Software
17.
Radiology ; 272(3): 749-56, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24814177

RESUMO

PURPOSE: To compare images acquired with 50% tube exposure with a dual-source computed tomographic (CT) scanner and reconstructed with sinogram-affirmed iterative reconstruction (SAFIRE) with 100% exposure images reconstructed with filtered back projection (FBP) for reader ability to detect stones, reader confidence, and findings outside the urinary tract. MATERIALS AND METHODS: In this HIPAA-compliant, institutional review board-approved study, imaging examinations in 99 patients with urolithiasis were assessed. Data from both tubes were reconstructed with FBP; data from the primary tube only were reconstructed with SAFIRE. Seven readers evaluated randomized studies for calculi in nine regions. Reader confidence was scored by using a five-point scale. Ancillary findings were noted. Nonparametric methods for clustered data were used to estimate the area under the receiver operating characteristic curves with 95% confidence intervals to test for noninferiority of 50% exposure with SAFIRE. RESULTS: Calculi were found in 113 locations (pyelocalyceal ureter, 86; proximal ureter, seven; midureter, four; distal ureter, 15; bladder, one) and not found in 752 locations. Mean area under the receiver operating characteristic curve for FBP was 0.879 (range, 0.607-0.967) and for SAFIRE, 0.883 (range, 0.646-0.971; 95% confidence interval: -0.025, 0.031). The SAFIRE images were not significantly inferior to FBP images (P = .001). Reader confidence levels for images with stones were similar with FBP and SAFIRE (P = .963). For the 52 patients who had extraurinary findings, readers reported them correctly in 74.4% (271 of 364) and 72.0% (262 of 364) of cases (P = .215) for FBP and SAFIRE, respectively. For the nine patients with potentially important findings per the reference standard, the detection rates were 44% (28 of 63) and 33% (21 of 63, P = .024), respectively. For the 43 patients with unimportant or likely unimportant findings, the false detection rates were 15% (44 of 301) and 14% (43 of 301, P = .756), respectively. CONCLUSION: The 50% tube exposure CT images reconstructed with SAFIRE were not inferior to 100% exposure images reconstructed with FBP for diagnosis of urolithiasis, without decreases in reader confidence.


Assuntos
Algoritmos , Armazenamento e Recuperação da Informação/métodos , Proteção Radiológica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Urolitíase/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Skeletal Radiol ; 43(12): 1729-35, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25172218

RESUMO

OBJECTIVE: Iterative metal artifact reduction (IMAR) is a sinogram inpainting technique that incorporates high-frequency data from standard weighted filtered back projection (WFBP) reconstructions to reduce metal artifact on computed tomography (CT). This study was designed to compare the image quality of IMAR and WFBP in total shoulder arthroplasties (TSA); determine the optimal amount of WFBP high-frequency data needed for IMAR; and compare image quality of the standard 3D technique with that of a faster 2D technique. MATERIALS AND METHODS: Eight patients with nine TSA underwent CT with standardized parameters: 140 kVp, 300 mAs, 0.6 mm collimation and slice thickness, and B30 kernel. WFBP, three 3D IMAR algorithms with different amounts of WFBP high-frequency data (IMARlo, lowest; IMARmod, moderate; IMARhi, highest), and one 2D IMAR algorithm were reconstructed. Differences in attenuation near hardware and away from hardware were measured and compared using repeated measures ANOVA. Five readers independently graded image quality; scores were compared using Friedman's test. RESULTS: Attenuation differences were smaller with all 3D IMAR techniques than with WFBP (p < 0.0063). With increasing high-frequency data, the attenuation difference increased slightly (differences not statistically significant). All readers ranked IMARmod and IMARhi more favorably than WFBP (p < 0.05), with IMARmod ranked highest for most structures. The attenuation difference was slightly higher with 2D than with 3D IMAR, with no significant reader preference for 3D over 2D. CONCLUSIONS: IMAR significantly decreases metal artifact compared to WFBP both objectively and subjectively in TSA. The incorporation of a moderate amount of WFBP high-frequency data and use of a 2D reconstruction technique optimize image quality and allow for relatively short reconstruction times.


Assuntos
Artefatos , Metais , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Articulação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Algoritmos , Análise de Variância , Artroplastia , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Med Phys ; 51(1): 103-112, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37962008

RESUMO

BACKGROUND: Studies of tin spectral filtration have demonstrated potential in reducing radiation dose while maintaining image quality for unenhanced computed tomography (CT) scans. The extent of dose reduction, however, was commonly measured using the change in the scanner's reported CTDIvol . This method does not account for how tin filtration affects patient organ and effective dose. PURPOSE: To investigate the effect of tin filtration on patient organ and effective dose for CT Lung Cancer Screening (LCS) and CT Colonography (CTC). METHODS: A previously-developed Monte Carlo program was adapted to model a 96-row CT scanner (Somatom Force, Siemens Healthineers) with tin filtration capabilities at 100 kV (100Sn) and 150 kV (150Sn). The program was then validated using experimental CTDIvol measurements at all available kV (70-150 kV) and tin-filtered kV options (100Sn and 150Sn). After validation, the program simulated LCS scans of the chest and CTC scan of the abdomen-pelvis for a population of 53 computational patient models from the extended cardiac-torso family. Each scan was performed using three different spectra: 120 kV, 100Sn, and 150Sn. CTDIvol -normalized organ doses and DLP-normalized effective doses, commonly referred to as dose conversion factors, were compared between the different spectra. RESULTS: For all LCS and CTC scans, CTDIvol -normalized organ doses and DLP-normalized effective doses increased with increasing beam hardness (120 kV, 100Sn, 150 Sn). For LCS, relative for 120 kV, conversion factors for 100Sn produced a median increase in effective dose of 9%, with organ dose increases of 8% to lung, 5% to breast, 15% to thyroid, and 3% to skin. Conversion factors for 150Sn produced a median increase in effective dose of 20%, with organ dose increases of 16%, 18%, 26%, and 12% to these same organs, respectively. For CTC, relative for 120 kV, conversion factors for 100Sn produced a median increase in effective dose of 12%, with organ dose increases of 9% to colon, 10% to liver, 11% to stomach, and 4% to skin. Conversion factors for 150Sn produced a median increase in effective dose of 21%, with organ dose increases of 16%, 17%, 19%, and 10% to these same organs, respectively. CONCLUSIONS: Results show that dose conversion factors are greater when using tin filtration and should be considered when evaluating tin's potential for dose reduction.


Assuntos
Colonografia Tomográfica Computadorizada , Neoplasias Pulmonares , Humanos , Estanho , Doses de Radiação , Detecção Precoce de Câncer , Neoplasias Pulmonares/diagnóstico por imagem
20.
AJR Am J Roentgenol ; 200(6): 1298-303, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23701068

RESUMO

OBJECTIVE: The purpose of this article is to determine the decrease in volume CT dose index (CTDI(vol)) and dose-length product (DLP) achieved by switching from fixed quality reference tube current protocols with automatic tube current modulation to protocols adjusting the quality reference tube current, slice collimation, and peak kilovoltage according to patient weight. MATERIALS AND METHODS: All adult patients who underwent CT examinations of the abdomen or abdomen and pelvis during 2010 using weight-based protocols who also underwent a CT examination in 2008 or 2009 using fixed quality reference tube current protocols were identified from the radiology information system. Protocol pages were electronically retrieved, and the CT model, examination date, scan protocol, CTDI(vol), and DLP were extracted from the DICOM header or by optical character recognition. There were 15,779 scans with dose records for 2700 patients. Changes in CTDI(vol) and DLP were compared only between examinations of the same patient and same CT system model for examinations performed in 2008 or 2009 and those performed in 2010. The final analysis consisted of 1117 comparisons in 1057 patients, and 1209 comparisons in 988 patients for CTDI(vol) and DLP, respectively. RESULTS: The change to a weight-based protocol resulted in a statistically significant reduction in CTDI(vol) and DLP on three MDCT system models (p < 0.001). The largest average CTDI(vol) decrease was 13.9%, and the largest average DLP decrease was 16.1% on a 64-MDCT system. Both the CTDI(vol) and DLP decreased the most for patients who weighed less than 250 lb (112.5 kg). CONCLUSION: Adjusting the CT protocol by selecting parameters according to patient weight is a viable method for reducing CT radiation dose. The largest reductions occurred in the patients weighing less than 250 lb.


Assuntos
Peso Corporal , Tomografia Computadorizada Multidetectores/métodos , Doses de Radiação , Proteção Radiológica/métodos , Radiografia Abdominal/métodos , Adulto , Protocolos Clínicos , Feminino , Humanos , Modelos Lineares , Masculino , Tomografia Computadorizada Multidetectores/instrumentação , Seleção de Pacientes , Radiografia Abdominal/instrumentação , Estudos Retrospectivos