Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Anal Chem ; 83(6): 2279-85, 2011 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-21344864

RESUMO

We report a method for combining the detection of single molecules (digital) and an ensemble of molecules (analog) that is capable of detecting enzyme label from 10(-19) M to 10(-13) M, for use in high sensitivity enzyme-linked immunosorbent assays (ELISA). The approach works by capturing proteins on microscopic beads, labeling the proteins with enzymes using a conventional multistep immunosandwich approach, isolating the beads in an array of 50-femtoliter wells (Single Molecule Array, SiMoA), and detecting bead-associated enzymatic activity using fluorescence imaging. At low concentrations of proteins, when the ratio of enzyme labels to beads is less than ∼1.2, beads carry either zero or low numbers of enzymes, and protein concentration is quantified by counting the presence of "on" or "off" beads (digital regime). (1) At higher protein concentrations, each bead typically carries multiple enzyme labels, and the average number of enzyme labels present on each bead is quantified from a measure of the average fluorescence intensity (analog regime). Both the digital and analog concentration ranges are quantified by a common unit, namely, average number of enzyme labels per bead (AEB). By combining digital and analog detection of singulated beads, a linear dynamic range of over 6 orders of magnitude to enzyme label was achieved. Using this approach, an immunoassay for prostate specific antigen (PSA) was developed. The combined digital and analog PSA assay provided linear response over approximately four logs of concentration ([PSA] from 8 fg/mL to 100 pg/mL or 250 aM to 3.3 pM). This approach extends the dynamic range of ELISA from picomolar levels down to subfemtomolar levels in a single measurement.


Assuntos
Ensaio de Imunoadsorção Enzimática/métodos , Animais , Bovinos , Humanos , Limite de Detecção , Masculino , Microesferas , Antígeno Prostático Específico/sangue , Antígeno Prostático Específico/metabolismo , Fatores de Tempo , beta-Galactosidase/metabolismo
2.
Clin Chem ; 57(12): 1712-21, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21998342

RESUMO

BACKGROUND: Measurement of prostate-specific antigen (PSA) in prostate cancer patients following radical prostatectomy (RP) has been hindered by the limit of quantification of available assays. Because radical prostatectomy removes the tissue responsible for PSA production, postsurgical PSA is typically undetectable with current assay methods. Evidence suggests, however, that more sensitive determination of PSA status following RP could improve assessment of patient prognosis and response to treatment and better target secondary therapy for those who may benefit most. We developed an investigational digital immunoassay with a limit of quantification 2 logs lower than current ultrasensitive third-generation PSA assays. METHODS: We developed reagents for a bead-based ELISA for use with high-density arrays of femtoliter-volume wells. Anti-PSA capture beads with immunocomplexes and associated enzyme labels were singulated within the wells of the arrays and interrogated for the presence of enzymatic product. We characterized analytical performance, compared its accuracy with a commercially available test, and analyzed longitudinal serum samples from a pilot study of 33 RP patients. RESULTS: The assay exhibited a functional sensitivity (20% interassay CV) <0.05 pg/mL, total imprecision <10% from 1 to 50 pg/mL, and excellent agreement with the comparator method. All RP samples were well within the assay measurement capability. PSA concentrations following surgery were found to be predictive of prostate cancer recurrence risk over 5 years. CONCLUSIONS: The robust 2-log improvement in limit of quantification relative to current ultrasensitive assays and the validated analytical performance of the assay allow for accurate assessment of PSA status after RP.


Assuntos
Ensaio de Imunoadsorção Enzimática/métodos , Antígeno Prostático Específico/sangue , Processamento Eletrônico de Dados , Humanos , Masculino , Microquímica/métodos , Pessoa de Meia-Idade , Projetos Piloto , Prostatectomia , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/cirurgia , Análise Serial de Proteínas/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
3.
Resuscitation ; 84(3): 351-6, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22885094

RESUMO

OBJECTIVE: To conduct a pilot study to evaluate the prognostic potential of serum tau protein measurements to predict neurological outcome 6 months following resuscitation from cardiac arrest. METHODS: In this retrospective observational study, we employed a new ultra sensitive digital immunoassay technology to examine serial serum samples from 25 cardiac arrest patients to examine tau release into serum as a result of brain hypoxia, and probe for its significance predicting six-month neurological outcome. Serial blood samples were obtained from resuscitated cardiac arrest survivors during their first five days in an intensive care unit, and serum total tau was measured. Cerebral function assessments were made using Cerebral Performance Categorization (CPC) at discharge from the ICU and six months later. Tau data were analyzed in the context of 6-month CPC scores. RESULTS: Tau elevations ranged from modest (<10 pg/mL) to very high (hundreds of pg/mL), and exhibited unexpected bi-modal kinetics in some patients. Early tau elevations appeared within 24h of cardiac arrest, and delayed elevations appeared after 24-48 h. In patients with delayed elevations, areas under the curves of tau concentration vs. hours since cardiac arrest were highly predictive of 6-month outcome (P<0.0005). CONCLUSION: High-sensitivity serum tau measurements combined with an understanding of tau release kinetics could have utility for hypoxic brain injury assessment and prediction of cerebral function outcome.


Assuntos
Isquemia Encefálica/sangue , Circulação Cerebrovascular/fisiologia , Parada Cardíaca/complicações , Recuperação de Função Fisiológica , Ressuscitação/métodos , Proteínas tau/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Isquemia Encefálica/complicações , Isquemia Encefálica/diagnóstico , Feminino , Seguimentos , Parada Cardíaca/fisiopatologia , Parada Cardíaca/terapia , Humanos , Imunoensaio , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Prognóstico , Estudos Retrospectivos
4.
J Immunol Methods ; 372(1-2): 177-86, 2011 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-21821036

RESUMO

The quantitative measurement of inflammatory cytokines in blood has been limited by insufficient sensitivity of conventional immunoassays. This limitation has prevented the widespread clinical monitoring of cytokine concentrations in chronic inflammatory diseases. We applied a sensitive, single molecule detection technology to measure TNF-α and IL-6 in the plasma of patients with Crohn's disease (CD), before and after treatment with anti-TNF-α therapy. Plasma from 17 patients with CD was collected prior to initiation of anti-TNF-α therapy, and the Crohn's disease activity index (CDAI) was determined for each patient. A sub-set of these patients returned for follow up 12 weeks after treatment started. Plasma from age- and gender-matched controls was also collected. Digital ELISAs were developed for TNF-α and IL-6, and the plasma concentrations of these cytokines were determined using digital ELISA. The limits of detection of the TNF-α and IL-6 digital ELISAs were 0.008 pg/mL and 0.006 pg/mL, respectively. Both cytokines were detected in all samples using digital ELISA and the concentrations of TNF-α and IL-6 in the plasma of patients with CD were (3.6±0.9) pg/mL and (10.9±11.2) pg/mL, respectively. TNF-α levels in patients and healthy controls were not significantly different, but the IL-6 levels in plasma were significantly elevated in patients compared to controls. After therapy, the mean reduction of the concentrations of free TNF-α and IL-6 were 46% and 58%, respectively. Digital ELISA provided the first quantitative measurements of TNF-α and IL-6 concentrations in the plasma of all patients in a population with CD. The changes in cytokine concentrations after therapy--which could be quantified because of the high sensitivity of digital ELISA--could be used for monitoring therapeutic efficacy.


Assuntos
Anti-Inflamatórios/uso terapêutico , Doença de Crohn/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Interleucina-6/sangue , Fator de Necrose Tumoral alfa/sangue , Adalimumab , Adolescente , Adulto , Idoso , Anticorpos Monoclonais/uso terapêutico , Anticorpos Monoclonais Humanizados , Certolizumab Pegol , Doença de Crohn/sangue , Doença de Crohn/tratamento farmacológico , Ensaio de Imunoadsorção Enzimática/normas , Seguimentos , Humanos , Fragmentos Fab das Imunoglobulinas/uso terapêutico , Infliximab , Limite de Detecção , Masculino , Pessoa de Meia-Idade , Polietilenoglicóis/uso terapêutico , Sensibilidade e Especificidade , Fator de Necrose Tumoral alfa/antagonistas & inibidores , Adulto Jovem
5.
PLoS One ; 6(12): e28263, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22194817

RESUMO

Amyloid ß (Aß) peptides are proteolytic products from amyloid precursor protein (APP) and are thought to play a role in Alzheimer disease (AD) pathogenesis. While much is known about molecular mechanisms underlying cerebral Aß accumulation in familial AD, less is known about the cause(s) of brain amyloidosis in sporadic disease. Animal and postmortem studies suggest that Aß secretion can be up-regulated in response to hypoxia. We employed a new technology (Single Molecule Arrays, SiMoA) capable of ultrasensitive protein measurements and developed a novel assay to look for changes in serum Aß42 concentration in 25 resuscitated patients with severe hypoxia due to cardiac arrest. After a lag period of 10 or more hours, very clear serum Aß42 elevations were observed in all patients. Elevations ranged from approximately 80% to over 70-fold, with most elevations in the range of 3-10-fold (average approximately 7-fold). The magnitude of the increase correlated with clinical outcome. These data provide the first direct evidence in living humans that ischemia acutely increases Aß levels in blood. The results point to the possibility that hypoxia may play a role in the amyloidogenic process of AD.


Assuntos
Peptídeos beta-Amiloides/sangue , Parada Cardíaca/sangue , Parada Cardíaca/complicações , Hipóxia/sangue , Hipóxia/etiologia , Fragmentos de Peptídeos/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Bioensaio , Encéfalo/metabolismo , Encéfalo/patologia , Feminino , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Admissão do Paciente , Ressuscitação , Fatores de Tempo
6.
Nat Biotechnol ; 28(6): 595-9, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20495550

RESUMO

The ability to detect single protein molecules in blood could accelerate the discovery and use of more sensitive diagnostic biomarkers. To detect low-abundance proteins in blood, we captured them on microscopic beads decorated with specific antibodies and then labeled the immunocomplexes (one or zero labeled target protein molecules per bead) with an enzymatic reporter capable of generating a fluorescent product. After isolating the beads in 50-fl reaction chambers designed to hold only a single bead, we used fluorescence imaging to detect single protein molecules. Our single-molecule enzyme-linked immunosorbent assay (digital ELISA) approach detected as few as approximately 10-20 enzyme-labeled complexes in 100 microl of sample (approximately 10(-19) M) and routinely allowed detection of clinically relevant proteins in serum at concentrations (<10(-15) M) much lower than conventional ELISA. Digital ELISA detected prostate-specific antigen (PSA) in sera from patients who had undergone radical prostatectomy at concentrations as low as 14 fg/ml (0.4 fM).


Assuntos
Proteínas Sanguíneas/análise , Ensaio de Imunoadsorção Enzimática/métodos , Microquímica/métodos , Humanos , Masculino , Antígeno Prostático Específico/sangue , Prostatectomia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA