Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
J Chir (Paris) ; 132(11): 454-8, 1995 Nov.
Artigo em Francês | MEDLINE | ID: mdl-8550712

RESUMO

The authors report about one observation of acute gastric volvulus on paraoesophageal hiatus hernia caused by a choledocholithiasis, requiring gastrectomy and choledochotomy in emergency. On the basis of this case they sum up the main characteristics of this complication of hiatus hernia and insist on a earlier diagnosis before stage of irreversible lesions.


Assuntos
Cálculos Biliares/complicações , Hérnia Hiatal/complicações , Volvo Gástrico/etiologia , Doença Aguda , Idoso , Idoso de 80 Anos ou mais , Colecistectomia , Coledocostomia , Feminino , Cálculos Biliares/cirurgia , Gastrectomia , Hérnia Hiatal/diagnóstico por imagem , Hérnia Hiatal/cirurgia , Humanos , Volvo Gástrico/diagnóstico por imagem , Volvo Gástrico/cirurgia , Tomografia Computadorizada por Raios X
2.
Ann Vasc Surg ; 15(2): 155-62, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11265078

RESUMO

Endovascular repair of abdominal aortic aneurysms (AAA) requires regular surveillance for early detection of endograft failure. CT scanning is the gold standard surveillance procedure. The purpose of this study was to assess the reliability of color duplex ultrasound (CDU) in comparison to CT scanning for detection of endoleaks and changes in aneurysmal diameter. From November 1996 to September 1999, a total of 41 patients treated by aortic endografting underwent regular surveillance with both CT scanning and CDU. There were 39 men and 2 women with a mean age of 71 years (range, 50-83). Endovascular treatment involved deployment of a straight aorto-aortic stent in 6 cases, bifurcated stent in 33, and aorta-to-unilateral iliac artery stent in 2. Stent deployment failed in one case; the procedure was conversion to open surgery. Primary or secondary endoleaks were detected in 17 patients (42%). Our findings indicated that CDU is less reliable than the CT scan for detection of endoleaks, but that reliability of CDU for surveillance of aneurysmal diameter is fair.


Assuntos
Angioplastia com Balão , Aneurisma da Aorta Abdominal/terapia , Complicações Pós-Operatórias/diagnóstico , Stents , Tomografia Computadorizada por Raios X , Ultrassonografia Doppler em Cores , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico , Falha de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA