Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Mol Genet Genomics ; 299(1): 36, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38492113

RESUMO

Previous studies have observed relationships between pancreatitis and gut microbiota; however, specific changes in gut microbiota abundance and underlying mechanisms in pancreatitis remain unknown. Metabolites are important for gut microbiota to fulfil their biological functions, and changes in the metabolic and immune environments are closely linked to changes in microbiota abundance. We aimed to clarify the mechanisms of gut-pancreas interactions and explore the possible role of metabolites and the immune system. To this end, we conducted two-sample Mendelian randomisation (MR) analysis to evaluate the casual links between four different types of pancreatitis and gut microbiota, metabolites, and inflammatory cytokines. A two-step MR analysis was conducted to further evaluate the probable mediating pathways involving metabolites and inflammatory cytokines in the causal relationship between pancreatitis and gut microbiota. In total, six potential mediators were identified in the causal relationship between pancreatitis and gut microbiota. Nineteen species of gut microbiota and seven inflammatory cytokines were genetically associated with the four types of pancreatitis. Metabolites involved in glucose and amino acid metabolisms were genetically associated with chronic pancreatitis, and those involved in lipid metabolism were genetically associated with acute pancreatitis. Our study identified alterations in the gut microbiota, metabolites, and inflammatory cytokines in pancreatitis at the genetic level and found six potential mediators of the pancreas-gut axis, which may provide insights into the precise diagnosis of pancreatitis and treatment interventions for gut microbiota to prevent the exacerbation of pancreatitis. Future studies could elucidate the mechanism underlying the association between pancreatitis and the gut microbiota.


Assuntos
Microbioma Gastrointestinal , Microbiota , Pancreatite , Humanos , Doença Aguda , Citocinas/genética , Microbioma Gastrointestinal/genética , Estudo de Associação Genômica Ampla , Pancreatite/genética , Análise da Randomização Mendeliana
2.
BMC Gastroenterol ; 23(1): 76, 2023 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-36927462

RESUMO

BACKGROUNDS AND AIMS: Complete and consecutive observation of the gastrointestinal (GI) tract continues to present challenges for current endoscopy systems. We developed a novel upper and mid gastrointestinal (UMGI) capsule endoscopy using the modified detachable string magnetically controlled capsule endoscopy (DS-MCE) and inspection method and aimed to assess the clinical application. METHODS: Patients were recruited to undergo UMGI capsule endoscopy followed by esophagogastroduodenoscopy. All capsule procedures in the upper gastrointestinal (UGI) tract were conducted under the control of magnet and string. The main outcome was technical success, and the secondary outcomes included visualization of the UMGI tract, examination time, diagnostic yield, compliance, and safety evaluation. RESULTS: Thirty patients were enrolled and all UMGI capsule procedures realized repeated observation of the esophagus and duodenum with detection rates of 100.0%, 80.0%, and 86.7% of Z-line, duodenal papilla, and reverse side of pylorus, respectively. String detachment was succeeded in 29 patients (96.7%) and the complete examination rate of UMGI tract was 95.45% (21/22). All UMGI capsule procedures were well tolerated with low discomfort score, and had a good diagnostic yield with per-lesion sensitivity of 96.2% in UGI diseases. No adverse events occurred. CONCLUSIONS: This new capsule endoscopy system provides an alternative screening modality for the UMGI tract, and might be indicated in cases of suspected upper and small bowel GI bleeding. Trial registration DS-MCE-UGI and SB, NCT04329468. Registered 27 March 2020, https://clinicaltrials.gov/ct2/results?cond=&term=NCT04329468 .


Assuntos
Endoscopia por Cápsula , Trato Gastrointestinal Superior , Humanos , Endoscopia por Cápsula/métodos , Esôfago , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiologia
3.
Clin Gastroenterol Hepatol ; 20(6): e1378-e1387, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34461303

RESUMO

BACKGROUND & AIMS: Both environmental factors, such as alcohol consumption and smoking, and genetic factors are strongly associated with the risk of developing chronic pancreatitis (CP). However, comprehensive understanding of their impacts on the progression of CP remains elusive. METHODS: A prospective cohort study was performed on a large cohort of CP patients with known genetic backgrounds. The cumulative incidence of pancreatic insufficiency after the onset of CP was analyzed using Kaplan-Meier survival curves. Multivariate Cox proportional hazards regression analysis also was performed. RESULTS: A total of 798 patients were enrolled in the study and followed up for 10.5 years. Rare pathogenic genotypes in the SPINK1, PRSS1, CTRC, or CFTR genes were identified in 410 (51.4%) patients. The development of pancreatic insufficiency was significantly earlier in patients with a history of smoking and/or alcohol consumption in both the positive (P < .001) and negative (P = .001) gene mutation groups. However, the development of pancreatic insufficiency did not differ significantly between patients with and without gene mutations despite alcohol and/or smoking status, with P values of .064 and .115, respectively. Multivariate Cox regression analysis showed that age at onset of CP (hazard ratio, [HR], 1.02; P < .001) and alcohol consumption (HR, 1.86; P < .001) were independent risk factors for the development of diabetes, while male sex (HR, 1.84; P = .022) and smoking (HR, 1.56; P = .028) were predictors of steatorrhea. CONCLUSIONS: Although rare pathogenic mutations in the 4 major susceptibility genes for CP were not correlated significantly with the development of pancreatic insufficiency, environmental factors (either alcohol consumption or smoking) significantly accelerated disease progression (ClinicalTrials.gov: NCT04574297).


Assuntos
Insuficiência Pancreática Exócrina , Pancreatopatias , Pancreatite Crônica , Insuficiência Pancreática Exócrina/genética , Humanos , Masculino , Mutação , Pancreatopatias/complicações , Pancreatite Crônica/complicações , Pancreatite Crônica/epidemiologia , Pancreatite Crônica/genética , Estudos Prospectivos , Fatores de Risco , Inibidor da Tripsina Pancreática de Kazal/genética
4.
Gastrointest Endosc ; 93(1): 133-139.e4, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32470426

RESUMO

BACKGROUND AND AIMS: Magnetically controlled capsule endoscopy (MCE) has become an efficient diagnostic modality for gastric diseases. We developed a novel automatic gastric lesion detection system to assist in diagnosis and reduce inter-physician variations. This study aimed to evaluate the diagnostic capability of the computer-aided detection system for MCE images. METHODS: We developed a novel automatic gastric lesion detection system based on a convolutional neural network (CNN) and faster region-based convolutional neural network (RCNN). A total of 1,023,955 MCE images from 797 patients were used to train and test the system. These images were divided into 7 categories (erosion, polyp, ulcer, submucosal tumor, xanthoma, normal mucosa, and invalid images). The primary endpoint was the sensitivity of the system. RESULTS: The system detected gastric focal lesions with 96.2% sensitivity (95% confidence interval [CI], 95.7%-96.5%), 76.2% specificity (95% CI, 75.97%-76.3%), 16.0% positive predictive value (95% CI, 15.7%-16.3%), 99.7% negative predictive value (95% CI, 99.74%-99.79%), and 77.1% accuracy (95% CI, 76.9%-77.3%) (sensitivity was 99.3% for erosions; 96.5% for polyps; 89.3% for ulcers; 87.2% for submucosal tumors; 90.6% for xanthomas; 67.8% for normal; and 96.1% for invalid images). Analysis of the receiver operating characteristic curve showed that the area under the curve for all positive images was 0.84. Image processing time was 44 milliseconds per image for the system and 0.38 ± 0.29 seconds per image for clinicians (P < .001). The kappa value of 2 times repeated reads was 1. CONCLUSIONS: The CNN faster-RCNN-based diagnostic program system showed good performance in diagnosing gastric focal lesions in MCE images.


Assuntos
Endoscopia por Cápsula , Gastropatias , Inteligência Artificial , Humanos , Redes Neurais de Computação , Curva ROC , Gastropatias/diagnóstico por imagem
5.
Dig Dis Sci ; 66(11): 4008-4016, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33433813

RESUMO

BACKGROUND AND AIMS: The high incidence of osteopathy among patients with chronic pancreatitis (CP) has garnered increased attention over recent years. The aims of this study were to assess the prevalence and risk factors for osteopathy in Chinese patients with CP. METHODS: This was a cross-sectional study of CP patients from a large center in China; patients were recruited between 31 January 2017 and 31 January 2018. Bone density and laboratory tests, including bone-related biochemical, inflammatory, and hormone parameters, were assessed prospectively. Differences between patients with and without osteopathy were analyzed. Logistic regression analysis was used to investigate associations between variables. RESULTS: In total, 104 CP patients were enrolled in this study (68.3% idiopathic and 31.7% alcoholic). According to the M-ANNHEIM classification, 87.5% of the patients were at an early stage (0-II). Osteopenia was diagnosed in 30.8% of patients and osteoporosis in 5.8%; thus, a total of 36.5% of patients presented with osteopathy. In multivariate analysis, the independent risk factors for osteopathy in CP patients were age (OR = 1.04; 95% CI = 1.00-1.08; P = 0.030), BMI (OR = 0.72; 95% CI = 0.58-0.89; P = 0.003), and PTH (OR = 0.96; 95% CI = 0.93-1.00; P = 0.022). CONCLUSIONS: This study is the first to report the prevalence of osteopathy in Chinese patients with CP. It found that age and low BMI are significant risk factors for osteopathy. Low PTH (but within the normal range) showed a weak association with osteopathy, which warrants further exploration.


Assuntos
Osteoporose/complicações , Pancreatite Crônica/complicações , Adulto , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco
6.
Gastrointest Endosc ; 91(6): 1379-1387, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31981648

RESUMO

BACKGROUND AND AIMS: Compared with conventional endoscopy, magnetically controlled capsule gastroscopy (MCCG) can be further optimized in gastric examination time and complete visualization of upper GI (UGI) mucosa. The second-generation MCCG (MCCG-2) was developed with higher image resolution and adaptive frame rate, and we aimed to evaluate its clinical availability for UGI examination in this study. METHODS: Consecutive patients undergoing MCCG examination between May to June 2019 were prospectively enrolled and randomized to swallow the first-generation MCCG (MCCG-1) or MCCG-2 in a 1:1 ratio. The main outcomes included visualization of the esophagus and duodenum, operation-related parameters, image quality, maneuverability, detection of lesions, and safety evaluation. RESULTS: Eighty patients were enrolled. In the MCCG-2 group, frames captured for esophageal mucosa and Z-line were 171.00 and 2.00, significantly increased from those in the MCCG-1 group (97.00 [P = .002] and .00 [P = .028], respectively). The gastric examination time was shortened from 7.78 ± .97 minutes to 5.27 ± .74 minutes (P < .001), with the total running time of the capsule extended from 702.83 minutes to 1001.99 minutes (P < .001). MCCG-2 also greatly improved the image quality (P < .001) and maneuverability (P < .01). No statistical difference existed in the detection of lesions between the 2 groups, and no adverse events occurred. CONCLUSIONS: MCCG-2 showed better performance in mucosal visualization, examination duration, and maneuverability, making better diagnosis of UGI diseases a possibility. (Clinical trial registration number: NCT03977935.).


Assuntos
Gastroscopia , Endoscopia por Cápsula , Características da Família , Humanos , Neoplasias Gástricas , Gravação em Vídeo
7.
BMC Gastroenterol ; 20(1): 364, 2020 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-33138792

RESUMO

BACKGROUND: A full spectrum of video capsule endoscopy (VCE) adverse events over the past two decades has not been evaluated. We aimed to determine pooled rates, predictors and temporal-trend of VCE adverse events over the past two decades. METHODS: Systematic search of PubMed and EMBASE for English-language publications reporting VCE adverse events (January 1, 2000 to March 31, 2019). Data were extracted independently by two investigators. Pooled VCE adverse event rates were calculated using the random or fixed model as appropriate. Predictors and temporal-trend of each adverse event were performed by meta-regression analyses. RESULTS: In total, 402 studies were identified, including 108,079 VCE procedures. Rate of retention, swallow disorder, aspiration, technical failure, and procedural adverse events were 0.73% (95% confidence interval [CI] 0.59-0.89%), 0.75% (95% CI 0.43-1.13%), 0.00% (95% CI 0.00-0.00%), 0.94% (95% CI 0.65-1.28%), 0.67% (95% CI 0.32-1.10%), respectively; incomplete examination rate of esophagus, stomach, small bowel, and colon were 9.05%, 7.69%, 12.08%, 19.19%, respectively. Patency capsule reduced retention rate by 5.04%, whereas known inflammatory bowel disease increased retention rate by 4.29%. Elder was the risk and protective factor for small bowel incomplete examination (0.30%) and swallow disorder (- 0.72%), respectively. Rates of retention and small bowel incomplete examination significantly declined over time (P = .0006 and P < .0001).. CONCLUSIONS: VCE adverse event rates were generally low, and retention and small bowel incomplete examination rates declined over the past two decades. Patients with known inflammatory bowel disease or elder should be alerted to high risk of retention or small bowel incomplete examination (PROSPERO: CRD42019139595).


Assuntos
Endoscopia por Cápsula , Doenças Inflamatórias Intestinais , Idoso , Endoscopia por Cápsula/efeitos adversos , Humanos , Intestino Delgado
8.
Endocr J ; 67(2): 113-123, 2020 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-31723088

RESUMO

Thyroglobulin measurement in the needle washout after fine-needle aspiration (FNA-Tg) served as an important measurement for suspicious recurrent or metastatic lesions. We conducted a pooled analysis to evaluate the diagnostic accuracy of FNA-Tg and searched electronic databases for original articles in English from 1993 through 2017. Finally, a total of 22 studies containing 2,670 lymph nodes (LNs) that enrolled participants with suspicious neck LNs during thyroid nodule workup or papillary thyroid cancer (PTC) follow-up were included. In our analysis, the overall pooled sensitivity for FNA-Tg was 0.91 (95%CI: 0.87-0.93), specificity was 0.94 (95% CI: 0.91-0.96). Meta regression revealed that the cutoff value and status of serum Tg were sources of heterogeneity for sensitivity, and the cutoff value was source of heterogeneity for specificity. Additionally, the cutoff value and status of serum Tg were sources of heterogeneity in the joint model. Subgroup analysis about cut-off value showed that the choice of 1 ng/mL had highest sensitivity, 40 ng/mL had highest specificity. At last, we arrived at the conclusion that FNA-Tg measurement had high specificity and sensitivity in the early detection of LNs metastases from PTC by our meta-analysis. The technique was simple and could be recommended to apply in any FNA facility, especially when LN were small-sized. Significantly, a better standardization of criteria for FNA-Tg detection and cutoff value was required to provide useful data and to improve management of PTC patients in the future.


Assuntos
Linfonodos/metabolismo , Tireoglobulina/metabolismo , Câncer Papilífero da Tireoide/metabolismo , Neoplasias da Glândula Tireoide/metabolismo , Biópsia por Agulha Fina , Humanos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Metástase Linfática/diagnóstico , Pescoço , Sensibilidade e Especificidade , Câncer Papilífero da Tireoide/diagnóstico , Câncer Papilífero da Tireoide/patologia , Neoplasias da Glândula Tireoide/diagnóstico , Neoplasias da Glândula Tireoide/patologia , Ultrassonografia
9.
Endoscopy ; 51(4): 360-364, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30822803

RESUMO

BACKGROUND: Esophageal capsule endoscopy is reported to be insufficiently accurate to replace esophagogastroduodenoscopy (EGD) because the passage of the capsule through the esophagus is passive and precludes a thorough investigation. We developed a modified capsule endoscopy technique, called detachable string magnetically controlled capsule endoscopy (DS-MCE), and performed a pilot study to assess the feasibility and safety of this novel technique. METHODS: 4 healthy volunteers and 21 patients with suspected esophageal disease first underwent DS-MCE followed by EGD within 1 week. Outcomes included technical success of DS-MCE, adverse events, discomfort, and diagnostic accuracy. RESULTS: DS-MCE was successfully carried out in all 25 participants. No adverse events were observed. Mean overall discomfort score during DS-MCE was 0.96 (range 0 - 3). DS-MCE diagnoses were in accordance with EGD in all 25 participants. The per-patient sensitivity of DS-MCE for esophageal disease detection was 100 %. The accuracy of DS-MCE for grading esophageal varices and reflux esophagitis were 66.7 % and 100 %, respectively. CONCLUSIONS: DS-MCE was a feasible, safe, and well-tolerated method for viewing the esophagus and proceeding with gastric examination after string detachment.


Assuntos
Endoscopia por Cápsula , Doenças do Esôfago/diagnóstico , Esôfago/diagnóstico por imagem , Imãs , Estômago/diagnóstico por imagem , Adulto , Endoscopia por Cápsula/instrumentação , Endoscopia por Cápsula/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Dig Dis Sci ; 64(7): 1908-1915, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30725289

RESUMO

BACKGROUND: Capsule endoscopy is currently available as a noninvasive and effective diagnostic modality to identify small bowel abnormalities, with a completion rate to the cecum between 75.1 and 95.6%. A novel magnetically controlled capsule endoscopy (MCE) system could facilitate passage of the capsule through the pylorus, thereby reducing the gastric transit time (GTT). OBJECTIVE: We performed this study to determine whether magnetic steering could improve the capsule endoscopy completion rate (CECR) compared to standard protocol. METHODS: Patients referred for MCE in our center from June 2017 to November 2017 were prospectively enrolled. Magnetic steering of the capsule through the pylorus was performed after standard gastric examination. CECR, GTT, pyloric transit time (PTT), and rapid gastric transit (GTT ≤ 30 min) rate were compared with a historical control group enrolled from January 2017 to May 2017. RESULTS: CECR was significantly higher in the intervention group (n = 107) than control group (n = 120) (100% vs. 94.2%, P = 0.02), with a significantly shorter GTT (22.2 vs. 84.5 min, P < 0.001) and PTT (4.4 vs. 56.7 min, P < 0.001). Rapid gastric transit rate in the intervention group was significantly higher than the control group (58.9% vs. 15.0%, P < 0.001). There were no statistical differences in the diagnostic yields between the two groups. CONCLUSIONS: Magnetic steering of capsule endoscopy improves small bowel CECR by reducing GTT, adding further support to MCE as a practical tool for noninvasive examination of both the stomach and small bowel. Trial registration ClinicalTrials.gov, ID: NCT03482661.


Assuntos
Endoscopia por Cápsula/métodos , Intestino Delgado/patologia , Magnetismo/métodos , Adulto , Cápsulas Endoscópicas , Endoscopia por Cápsula/instrumentação , Desenho de Equipamento , Feminino , Trânsito Gastrointestinal , Humanos , Intestino Delgado/fisiopatologia , Magnetismo/instrumentação , Imãs , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estômago/patologia , Estômago/fisiopatologia , Fatores de Tempo
11.
Dig Dis Sci ; 64(5): 1297-1304, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30560329

RESUMO

BACKGROUND AND AIMS: Good gastric preparation is essential for magnetically controlled capsule gastroscopy (MCCG) examination. This study aims to determine if repetitive position change after dimethicone premedication could further improve gastric cleanliness for MCCG. METHODS: Consecutive patients referred for MCCG in our center from May 7 to May 31, 2018 were prospectively enrolled and randomized to undergo repetitive position change for 15 min (position change group) or not (conventional group) after ingesting dimethicone. Primary outcome was gastric cleanliness score and secondary outcomes were detection rate of positive findings, number of lesions per patient, gastric examination time, and safety of MCCG. RESULTS: Totals of 43 and 40 were included in the position change and conventional groups, respectively. Gastric cleanliness score in the position change group was significantly higher than in the conventional group (21.2 ± 1.0 vs. 18.6 ± 2.0, P  < 0.001), as was the proportion of acceptable gastric cleanliness (gastric cleanliness score ≥ 18) (100% vs. 72.5%, P  < 0.001). There was no statistical difference in detection rate of positive findings between the two groups (27.9% vs. 27.5%, P  = 0.97). In the position change group, the gastric examination time was significantly reduced (13.2 ± 4.0 vs. 15.3 ± 5.1, P = 0.043). No adverse events were observed. CONCLUSIONS: Repetitive position change after dimethicone premedication significantly improves gastric cleanliness for MCCG examination. Clinical Trial Registration ClinicalTrials.gov, ID: NCT03514966.


Assuntos
Endoscopia por Cápsula/métodos , Jejum/fisiologia , Esvaziamento Gástrico/fisiologia , Gastroscopia/métodos , Posicionamento do Paciente/métodos , Neoplasias Gástricas/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Dimetilpolisiloxanos/administração & dosagem , Feminino , Esvaziamento Gástrico/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Método Simples-Cego , Adulto Jovem
12.
Gastrointest Endosc ; 88(4): 746-754, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30005825

RESUMO

BACKGROUNDS AND AIMS: Delayed gastric transit of the capsule may lead to incomplete small bowel examination, reducing the diagnostic yield. Thus, this study was designed to determine if magnetic steering could enhance capsule gastric emptying and mucosal visualization within the duodenum. METHODS: The intervention group comprised 100 patients undergoing magnetic-controlled capsule endoscopy between May to September 2017 in whom magnetic control was used to assist transpyloric passage of the capsule and duodenal inspection. A cohort of 100 patients who had undergone the procedure before May 2017 was randomly selected from the database as an historic control group in whom transpyloric movement of the capsule occurred spontaneously (without magnetic assistance). The difference in the pyloric transit time (PTT) and duodenal papilla detection rate (DPDR) between the 2 groups were compared, and related factors were also investigated. RESULTS: Transpyloric passage of the capsule under magnetic control was successfully performed in 59 patients (59%). Median PTT was greatly reduced in the intervention group from 58.38 minutes (range, 13.45-87.47) to 4.69 minutes (range, 1.56-55.00; P < .001), and DPDR was also greatly improved with magnetic steering (30.5% vs 9%, P < .001). Magnetic steering, male gender, and higher body mass index were independently associated with reduced gastric transit time and magnetic steering with an enhanced DPDR. CONCLUSIONS: Magnetic steering of the capsule can enhance gastric emptying of the capsule and may prove useful in nonobese and female patients who appeared to have longer gastric transit time and achieved a better DPDR than that under the action of peristalsis alone. (Clinical trial registration number: NCT03441945.).


Assuntos
Ampola Hepatopancreática/diagnóstico por imagem , Endoscopia por Cápsula/métodos , Trânsito Gastrointestinal , Adulto , Índice de Massa Corporal , Feminino , Humanos , Mucosa Intestinal/diagnóstico por imagem , Imãs , Masculino , Pessoa de Meia-Idade , Fatores Sexuais , Estômago
13.
Gastrointest Endosc ; 88(3): 466-474.e1, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29753039

RESUMO

BACKGROUND AND AIMS: Gastric cancer (GC) is the fourth most common cancer and the fourth leading cause of cancer death worldwide. In some Asian countries, screening EGD has greatly improved the survival rate. However, patients' discomfort and the need for sedation may limit adherence to screening programs. Previous studies have shown good tolerance and good agreement of magnetically controlled capsule gastroscopy (MCCG) with EGD. This study was designed to assess the application of MCCG in GC detection in an asymptomatic population. METHODS: In this observational cohort study, 3182 asymptomatic individuals undergoing MCCG in 99 participating medical examination centers from April to December 2016 were enrolled. Patients with ulcers and suspected malignancies were referred for gastroscopy and biopsy. The detection rate of GC and focal lesions were used to explore the application of MCCG in asymptomatic individuals. RESULTS: Seven patients (0.22%) were diagnosed with GC among the enrolled 3182 individuals, accounting for 0.74% (7/948) in patients over 50 years. No gender disparity was observed. EGD and biopsy confirmed adenocarcinoma in all cases of suspected malignancy. Benign polyps, gastric ulcers, and submucosal tumors were found in 10.4%, 4.9%, and 3.6% of patients, respectively. There was a trend for the prevalence of focal lesions to increase with age. MCCG examination proved to be safe. CONCLUSIONS: MCCG can detect cancer and benign lesions and is safe and clinically feasible in a large population. Studies of its role in a screening program should be considered.


Assuntos
Adenocarcinoma/diagnóstico , Endoscopia por Cápsula/métodos , Detecção Precoce de Câncer/métodos , Gastroscopia/métodos , Neoplasias Gástricas/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças Assintomáticas , Feminino , Humanos , Magnetismo , Masculino , Pessoa de Meia-Idade , Adulto Jovem
14.
Gastrointest Endosc ; 86(3): 519-524.e1, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28062312

RESUMO

BACKGROUND AND AIMS: Almost all studies on post-ERCP pancreatitis (PEP) have mainly involved patients with biliary diseases rather than chronic pancreatitis (CP), and the concept that CP seems to be a protective factor associated with PEP has not been studied in detail. The aim of this study was to determine the incidence of PEP in patients with CP at different clinical stages and to identify the predictive and protective factors of PEP in a large cohort. METHODS: In this observational cohort study, medical records of patients with CP (CP group) and biliary diseases (BD group) in a tertiary hospital from January 2011 to May 2015 were examined. The difference in the incidence of PEP between CP group and BD group and the risk of PEP at different clinical stages of CP were calculated by the χ2 test or the Fisher exact test. The predictive and protective factors for PEP were investigated by univariate and multivariate analysis. RESULTS: In total, 2028 ERCP procedures were performed in 1301 patients with CP and 2000 procedures in 1655 patients with BD. The overall incidence of PEP in CP group (4.5%) was similar to that in the BD group (4.8%; P = .747). However, CP patients had significantly lower rates of moderate and severe attacks (0% vs 1.3%, P < .01). According to the M-ANNHEIM classification, the PEP incidences of CP at stages 0, I, II, III, and IV were 4.4%, 5.1%, 3.8%, 2.0%, and 2.0%, respectively. CP patients at stage Ia had the highest PEP incidence (8.0%) among all CP patients, significantly higher than that at stages Ib + Ic (3.9%) and II (3.8%). Female gender, history of acute pancreatitis, and prior PEP were independent risk factors of PEP, whereas extracorporeal shock wave lithotripsy was a protective factor. CONCLUSIONS: Compared with BD patients, CP patients had similar incidence of PEP overall but lower grades of severity. The incidence of PEP in CP patients decreased significantly with disease progression. (Clinical trial registration number: NCT02781987.).


Assuntos
Doenças Biliares/cirurgia , Colangiopancreatografia Retrógrada Endoscópica , Pancreatopatias/cirurgia , Pancreatite/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Doença Aguda , Adulto , Idoso , China/epidemiologia , Estudos de Coortes , Constrição Patológica/cirurgia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Ductos Pancreáticos , Pancreatite Crônica , Fatores de Proteção , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores Sexuais
15.
16.
Gastrointest Endosc ; 89(4): 900-901, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30902215
17.
Adv Sci (Weinh) ; 11(38): e2402550, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39119875

RESUMO

Chronic pancreatitis (CP) is a complex disease with genetic and environmental factors at play. Through trio exome sequencing, a de novo SEC16A frameshift variant in a Chinese teenage CP patient is identified. Subsequent targeted next-generation sequencing of the SEC16A gene in 1,061 Chinese CP patients and 1,196 controls reveals a higher allele frequency of rare nonsynonymous SEC16A variants in patients (4.90% vs 2.93%; odds ratio [OR], 1.71; 95% confidence interval [CI], 1.26-2.33). Similar enrichments are noted in a French cohort (OR, 2.74; 95% CI, 1.67-4.50) and in a biobank meta-analysis (OR, 1.16; 95% CI, 1.04-1.31). Notably, Chinese CP patients with SEC16A variants exhibit a median onset age 5 years earlier than those without (40.0 vs 45.0; p = 0.012). Functional studies using three CRISPR/Cas9-edited HEK293T cell lines show that loss-of-function SEC16A variants disrupt coat protein complex II (COPII) formation, impede secretory protein vesicles trafficking, and induce endoplasmic reticulum (ER) stress due to protein overload. Sec16a+/- mice, which demonstrate impaired zymogen secretion and exacerbated ER stress compared to Sec16a+/+, are further generated. In cerulein-stimulated pancreatitis models, Sec16a+/- mice display heightened pancreatic inflammation and fibrosis compared to wild-type mice. These findings implicate a novel pathogenic mechanism predisposing to CP.


Assuntos
Estresse do Retículo Endoplasmático , Retículo Endoplasmático , Pancreatite Crônica , Adolescente , Adulto , Animais , Feminino , Humanos , Masculino , Camundongos , China , Modelos Animais de Doenças , Retículo Endoplasmático/metabolismo , Retículo Endoplasmático/genética , Estresse do Retículo Endoplasmático/genética , Predisposição Genética para Doença/genética , Complexo de Golgi/metabolismo , Complexo de Golgi/genética , Células HEK293 , Pancreatite Crônica/genética , Pancreatite Crônica/metabolismo
18.
BMJ ; 384: e078581, 2024 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-38443074

RESUMO

OBJECTIVE: To evaluate the diagnostic accuracy and safety of using magnetically guided capsule endoscopy with a detachable string (ds-MCE) for detecting and grading oesophagogastric varices in adults with cirrhosis. DESIGN: Prospective multicentre diagnostic accuracy study. SETTING: 14 medical centres in China. PARTICIPANTS: 607 adults (>18 years) with cirrhosis recruited between 7 January 2021 and 25 August 2022. Participants underwent ds-MCE (index test), followed by oesophagogastroduodenoscopy (OGD, reference test) within 48 hours. The participants were divided into development and validation cohorts in a ratio of 2:1. MAIN OUTCOME MEASURES: The primary outcomes were the sensitivity and specificity of ds-MCE in detecting oesophagogastric varices compared with OGD. Secondary outcomes included the sensitivity and specificity of ds-MCE for detecting high risk oesophageal varices and the diagnostic accuracy of ds-MCE for detecting high risk oesophagogastric varices, oesophageal varices, and gastric varices. RESULTS: ds-MCE and OGD examinations were completed in 582 (95.9%) of the 607 participants. Using OGD as the reference standard, ds-MCE had a sensitivity of 97.5% (95% confidence interval 95.5% to 98.7%) and specificity of 97.8% (94.4% to 99.1%) for detecting oesophagogastric varices (both P<0.001 compared with a prespecified 85% threshold). When using the optimal 18% threshold for luminal circumference of the oesophagus derived from the development cohort (n=393), the sensitivity and specificity of ds-MCE for detecting high risk oesophageal varices in the validation cohort (n=189) were 95.8% (89.7% to 98.4%) and 94.7% (88.2% to 97.7%), respectively. The diagnostic accuracy of ds-MCE for detecting high risk oesophagogastric varices, oesophageal varices, and gastric varices was 96.3% (92.6% to 98.2%), 96.9% (95.2% to 98.0%), and 96.7% (95.0% to 97.9%), respectively. Two serious adverse events occurred with OGD but none with ds-MCE. CONCLUSION: The findings of this study suggest that ds-MCE is a highly accurate and safe diagnostic tool for detecting and grading oesophagogastric varices and is a promising alternative to OGD for screening and surveillance of oesophagogastric varices in patients with cirrhosis. TRIAL REGISTRATION: ClinicalTrials.gov NCT03748563.


Assuntos
Endoscopia por Cápsula , Varizes Esofágicas e Gástricas , Varizes , Adulto , Humanos , Varizes Esofágicas e Gástricas/diagnóstico , Varizes Esofágicas e Gástricas/etiologia , Cirrose Hepática/complicações , Estudos Prospectivos
19.
Gastrointest Endosc ; 87(1): 321-322, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29241861
20.
IEEE Trans Cybern ; 53(4): 2275-2287, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34623292

RESUMO

This article investigates differential graphical games for linear multiagent systems with a leader on fixed communication graphs. The objective is to make each agent synchronize to the leader and, meanwhile, optimize a performance index, which depends on the control policies of its own and its neighbors. To this end, a distributed adaptive Nash equilibrium solution is proposed for the differential graphical games. This solution, in contrast to the existing ones, is not only Nash but also fully distributed in the sense that each agent only uses local information of its own and its immediate neighbors without using any global information of the communication graph. Moreover, the asymptotic stability and global Nash equilibrium properties are analyzed for the proposed distributed adaptive Nash equilibrium solution. As an illustrative example, the differential graphical game solution is applied to the microgrid secondary control problem to achieve fully distributed voltage synchronization with optimized performance.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA