Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMC Ophthalmol ; 19(1): 132, 2019 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-31226955

RESUMO

BACKGROUND: Although the pathogenesis of glaucoma is not fully understood,an elevated intraocular pressure (IOP) is a major factor contributing to its development and progression. The aim of this study was to investigate the changes in the vessel densities of the macula and optic nerve head (ONH) after an acute elevation in the intraocular pressure (IOP) observed using optical coherence tomography angiography (OCTA). METHODS: This was a prospective comparative study of subjects with narrow anterior chamber angles who underwent laser peripheral iridotomies (LPIs). The IOP was measured before and one hour after the LPI. The retinal vessel densities of the macula and ONH were measured using OCTA at the baseline and one hour after the LPI. RESULTS: A total of 64 eyes of 51 individuals were enrolled in this study, and 58 eyes of 43 individuals finally completed the study with a mean IOP rise of 10.5 ± 7.6 mmHg after the LPI. Based on the magnitude of the rise in the IOP, we divided the subjects into three groups: group A = IOP rise ≤10 mmHg, group B = 10 mmHg < IOP rise ≤20 mmHg, and group C = IOP rise > 20 mmHg. The vessel density did not differ after the acute IOP elevation in either the macular region or papillary region in group A or group B (p > 0.05), but there was a significant difference in group C (p < 0.05). However, when the subjects were not separated into groups, the vessel densities of the ONH and macular region did not differ between the measurements obtained at the baseline and one hour after the LPI (p > 0.05). The correlation existed in peripapillary and macular vessel density (p < 0.05). CONCLUSION: In these subjects with narrow antenior chamber, an acute mild or moderate IOP elevation for one hour after the LPI did not affect the vessel density in the macula or ONH, as examined using OCTA. However, when the IOP rise was greater than 20 mmHg, the macular and papillary vessel density decreased significantly.


Assuntos
Câmara Anterior/patologia , Hipertensão Ocular/patologia , Vasos Retinianos/patologia , Doença Aguda , Idoso , Feminino , Humanos , Pressão Intraocular/fisiologia , Macula Lutea/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Disco Óptico/irrigação sanguínea , Estudos Prospectivos , Tomografia de Coerência Óptica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA