Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Ultrasound Med ; 35(6): 1167-76, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27105950

RESUMO

OBJECTIVES: This study assessed the use of 3-dimensional (3D) speckle-tracking echocardiography for noninvasive monitoring and diagnosis of acute rejection in heart transplant recipients. METHODS: Fifteen heart transplant recipients underwent 32 endomyocardial biopsies; echocardiography was performed within 3 hours before biopsy. Twenty-four biopsies (acute rejection-negative group) showed grade 0 or 1A rejection, and 8 biopsies (acute rejection-positive group) showed grade 1B or higher rejection (based on the International Society for Heart and Lung Transplantation criteria). Two-dimensional, M-mode, pulsed Doppler, and tissue Doppler echocardiography were performed to assess conventional heart structure and function, and 3D full-volume echocardiography was recorded and analyzed. RESULTS: Global peak longitudinal strain was significantly lower in the acute rejection-negative group compared to the positive group (mean ± SD, -7.38% ± 1.34% versus -10.88% ± 3.81%; P = .017). Differences in left ventricular global peak radial strain (28.79% ± 10.79% versus 24.32% ± 5.24%; P= .272), global peak circumferential strain (-12.16% ± 4.87% versus -12.61% ± 2.38%; P = .806), and ejection fraction (49.42% ± 12.17% versus 50.68% ± 7.26%; P = .824) between the negative and positive groups were not significant. Significant correlations were observed between the left ventricular ejection fraction and global peak longitudinal, global peak radial, and global peak circumferential (r = -0.72; P < .001; r = 0.60; P < 0.001; and r = -0.69; P < 0.001, respectively). Receiver operating characteristic curve analysis showed that a global peak longitudinal strain cutoff value of less than -9.55% could predict grade 1B or higher rejection with sensitivity of 87.50% and specificity of 54.17%. CONCLUSIONS: Three-dimensional speckle-tracking echocardiography-derived global peak longitudinal strain is a useful parameter for detecting acute rejection; thus, 3D speckle-tracking echocardiography can monitor dynamic and acute rejection (≥1B) in heart transplant recipients.


Assuntos
Ecocardiografia Tridimensional/métodos , Rejeição de Enxerto/diagnóstico por imagem , Transplante de Coração , Doença Aguda , Biópsia , Feminino , Rejeição de Enxerto/patologia , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
2.
Echocardiography ; 32(6): 983-92, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25251548

RESUMO

AIMS: To observe the geometric changes in aortic-mitral valve coupling (AMC) on three-dimensional transesophageal echocardiography and the factors leading to decreased mitral regurgitation (MR) after coronary artery bypass grafting (CABG). METHODS AND RESULTS: This study included 23 patients undergoing CABG for coronary artery disease. Fifteen patients with moderate to severe MR were separately analyzed to determine whether the severity of MR influences the geometric change in AMC. Echocardiographic examinations were performed pre- and post-CABG, and the studied parameters were obtained using Siemens Auto Valve Analysis software. The effective mitral regurgitant orifice area, left ventricular ejection fraction (LVEF), end-diastolic volume (EDV), and end-systolic volume (ESV) were measured pre- and post-CABG using Philips QLAB software. Ischemic MR, EDV, and ESV significantly decreased (all P < 0.05) and LVEF significantly improved (P < 0.05) after CABG. There were no significant differences between the pre- and post-CABG mitral valve (MV) parameters, aortic valve parameters, aortic-mitral annular angle, or centroid distance (all P > 0.05). Patients with moderate to severe MR exhibited the same results. CONCLUSION: The results of this study show that CABG does not cause an acute change in the geometry of AMC. Improved left ventricular function might increase the closing force of the MV, leading to decreased MR after CABG alone. MR significantly improved after CABG alone without MV treatment in the present study. This result may help to guide surgeons in choosing the optimal surgical methods for individual patients.


Assuntos
Valva Aórtica/diagnóstico por imagem , Ponte de Artéria Coronária/efeitos adversos , Ecocardiografia Tridimensional/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Valva Mitral/diagnóstico por imagem , Ponte de Artéria Coronária/métodos , Ecocardiografia Transesofagiana/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA