Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
2.
Radiologe ; 59(10): 898-905, 2019 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-31172246

RESUMO

BACKGROUND: It can be expected that the number of 7 T MRI systems for clinical use will increase in the future. On the other hand, almost no medical implant has been labeled MR conditional for 7 T, so far, leaving the question of implant safety unanswered to the MR operator. METHODS: In principle, the same interactions between magnetizable and electric conductive material apply at 7 T as known at lower magnetic field strengths. However, there are a few important differences that need to be taken into account to perform a profound risk-benefit analysis. After a more general introduction of technical differences between 3 and 7 T systems, the article will focus mainly on safety assessments with regard to interactions between implant and radiofrequency (RF) transmit fields. In addition, strategies to ensure access at 7 T will be discussed. RESULTS OF PRACTICAL RELEVANCE: Besides hazards due to the magnetic force which can be up to 2.3 times stronger at 7 T compared to 3 T, increased risks of RF-induced tissue heating are the most critical aspects. The resonant-length of an implant at 7 T is about 5 cm. Other than at 3 T, MR systems at 7 T are less standardized. Especially with regard to the RF transmit coil and transmission methods used, substantial differences need to be expected. Hence, it is important to critically question published safety assessments of implants and to have a thorough discussion about how this relates to the individual exposure scenario. For nonmagnetic implants without a dedicated 7 T safety evaluation, but which are 3 T MR conditional and have a certain minimum distance to the RF transmit coil, a consensus recommendation from the national network German Ultrahigh Field Imaging (GUFI) may be helpful.


Assuntos
Imageamento por Ressonância Magnética , Próteses e Implantes , Ondas de Rádio , Campos Magnéticos , Imageamento por Ressonância Magnética/efeitos adversos , Magnetismo
3.
Magn Reson Med ; 80(1): 239-247, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29194732

RESUMO

PURPOSE: A prerequisite for cardiac MR (CMR) imaging is adequate synchronization of image acquisition with the cardiac cycle. Electrocardiogram triggering may be hampered by electromagnetic interferences at high field strength. The purpose of this work is to evaluate the feasibility of Doppler ultrasound triggering for CMR image synchronization at 7T ultra-high-field MRI. METHODS: A custom-built Doppler ultrasound (DUS) trigger device was developed. Magnetic resonance compatibility was evaluated using E- and H-field probes and flip angle maps prior to the study. Cardiac MR was performed at 7T in 13 healthy subjects using DUS and pulse oximetry for triggering. For validation of the trigger signal, the electrocardiogram, pulse, and DUS signals were compared outside of the MR room. Breath-hold cine fast low-angle-shot sequences were acquired in short-axis and four-chamber view. Image quality was assessed by two senior radiologists and by measurement of endocardial blurring. RESULTS: The maximal change in E- and H-field distributions with and without transducer was 5%. No interferences were observed between DUS and MRI in the B1 maps and during CMR imaging. Validation of the DUS trigger signal resulted in a high correlation to the electrocardiographic signal of r = 0.99. Analysis of image and trigger quality revealed no significant differences. CONCLUSION: Doppler ultrasound was applied as a new trigger method in CMR at 7T. The transmission line and transducer were locally approved as 7T MR conditional, and were successfully tested for image synchronization at 7T. In the future, this method needs to be evaluated in a larger patient population. Magn Reson Med 80:239-247, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Ultrassonografia Doppler , Adulto , Artefatos , Eletrocardiografia , Radiação Eletromagnética , Estudos de Viabilidade , Feminino , Voluntários Saudáveis , Testes de Função Cardíaca , Humanos , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador , Masculino , Imagem Multimodal/métodos , Reprodutibilidade dos Testes , Adulto Jovem
4.
Eur J Nucl Med Mol Imaging ; 45(4): 593-601, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29282517

RESUMO

INTRODUCTION: Radiological assessment of brain tumors is widely based on the Radiology Assessment of Neuro-Oncology (RANO) criteria that consider non-specific T1 and T2 weighted images. Limitation of the RANO criteria is that they do not include metabolic imaging techniques that have been reported to be helpful to differentiate treatment related changes from true tumor progression. In the current study, we assessed if the combined use of MRI and PET with hybrid 11C-MET PET/MRI can improve diagnostic accuracy and diagnostic confidence of the readers to differentiate treatment related changes from true progression in recurrent glioma. METHODS: Fifty consecutive patients with histopathologically proven glioma were prospectively enrolled for a hybrid 11C-MET PET/MRI to differentiate recurrent glioma from treatment induced changes. Sole MRI data were analyzed based on RANO. Sole PET data and in a third evaluation hybrid 11C-MET-PET/MRI data were assessed for metabolic respectively metabolic and morphologic glioma recurrence. Diagnostic performance and diagnostic confidence of the reader were calculated for the different modalities, and the McNemar test and Mann-Whitney U Test were applied for statistical analysis. RESULTS: Hybrid 11C-MET PET/MRI was successfully performed in all 50 patients. Glioma recurrence was diagnosed in 35 of the 50 patients (70%). Sensitivity and specificity were calculated for MRI (86.11% and 71.43%), for 11C-MET PET (96.77% and 73.68%), and for hybrid 11C-MET-PET/MRI (97.14% and 93.33%). For diagnostic accuracy hybrid 11C-MET-PET/MRI (96%) showed significantly higher values than MRI alone (82%), whereas no significant difference was found for 11C-MET PET (88%). Furthermore, by rating on a five-point Likert scale significantly higher scores were found for diagnostic confidence when comparing 11C-MET PET/MRI (4.26 ± 0,777) to either PET alone (3.44 ± 0.705) or MRI alone (3.56 ± 0.733). CONCLUSION: This feasibility study showed that hybrid PET/MRI might strengthen RANO classification by adding metabolic information to conventional MRI information. Future studies should evaluate the clinical utility of the combined use of 11C-MET PET/MRI in larger patient cohorts.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Glioma/diagnóstico por imagem , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Radioisótopos de Carbono , Humanos , Metionina/análogos & derivados , Recidiva Local de Neoplasia/diagnóstico por imagem
5.
Eur Radiol ; 23(4): 1059-66, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23064714

RESUMO

OBJECTIVE: The aim of this study was to assess the feasibility of first-pass contrast-enhanced renal MR angiography (MRA) at 7 T. METHODS: In vivo first-pass contrast-enhanced high-field examinations were obtained in eight healthy subjects on a 7-T whole-body MRI. A custom-built body transmit/receive radiofrequency (RF) coil and RF system suitable for RF shimming were used for image acquisition. For dynamic imaging, gadobutrol was injected intravenously and coronal unenhanced, arterial and venous data sets using a T1-weighted spoiled gradient-echo sequence were obtained. Qualitative image analysis and assessment of artefact impairment were performed by two senior radiologists using a five-point scale (5 = excellent, 1 = non-diagnostic). SNR and CNR of the perirenal abdominal aorta and both main renal arteries were assessed. RESULTS: Qualitative image evaluation revealed overall high-quality delineation of all assessed segments of the unenhanced arterial vasculature (meanunenhanced 4.13). Nevertheless, the application of contrast agent revealed an improvement in vessel delineation of all the vessel segments assessed, confirmed by qualitative (meanunenhanced 4.13 to meancontrast-enhanced 4.85) and quantitative analysis (SNR meanunenhanced 64.3 to meancontrast-enhanced 98.4). CONCLUSION: This study demonstrates the feasibility and current constraints of ultra-high-field contrast-enhanced renal MRA relative to unenhanced MRA.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Compostos Organometálicos , Artéria Renal/anatomia & histologia , Adulto , Meios de Contraste , Feminino , Humanos , Masculino , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Radiologe ; 53(12): 1118-24, 2013 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-24221697

RESUMO

The unparalleled soft tissue contrast of magnetic resonance imaging (MRI) and the functional information obtainable with 18-F fluorodeoxyglucose positron emission tomography (FDG-PET) render MR-PET well-suited for oncological and psychiatric imaging. The lack of ionizing radiation with MRI also makes MR-PET a promising modality for oncology patients requiring frequent follow-up and pediatric patients. Lessons learned with PET computed tomography (CT) over the last few years do not directly translate to MR-PET. For example, in PET-CT the Hounsfield units derived from CT are used for attenuation correction (AC). As 511 keV photons emitted in PET examinations are attenuated by the patient's body CT data are converted directly to linear attenuation coefficients (LAC); however, proton density measured by MRI is not directly related to the radiodensity or LACs of biological tissue. Thus, direct conversion to LAC data is not possible making AC more challenging in simultaneous MRI-PET scanning. In addition to these constraints simultaneous MRI-PET acquisitions also improve on some solutions to well-known challenges of hybrid imaging techniques, such as limitations in motion correction. This article reports on initial clinical experiences with simultaneously acquired MRI-PET data, focusing on the potential benefits and limitations of MRI with respect to motion correction as well as metal and attenuation correction artefacts.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Humanos
7.
Magn Reson Med ; 68(5): 1593-9, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22287286

RESUMO

Determining the MR compatibility of medical implants and devices is becoming increasingly relevant. In most cases, the heating of conductive implants due to radiefrequency (RF) excitation pulses is measured by fluoroptic temperature sensors in relevant tests for approval. Another common method to determine these heating effects is MR thermometry using the proton resonance frequency. This method gives good results in homogeneous phantoms. However in many cases, technical shortcomings such as susceptibility artifacts prohibit exact proton resonance frequency thermometry near medical implants. Therefore, this work aimed at developing a fast T1-based method which allows controlled MR-related heating of a medical implant while simultaneously quantifying the spatial and temporal temperature distribution. To this end, an inversion recovery snapshot Fast Low-Angle Shot (FLASH) sequence was modified with additional off-resonant heating pulses. With an accelerated imaging method and a sliding-window technique, every 7.6 s a new temperature map could be generated with a spatial in-plane resolution of 2 mm. The temperature deviation from calculated temperature values to reference fluoroptic probe was found to be smaller than 1 K.


Assuntos
Transferência de Energia , Equipamentos e Provisões , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Termografia/instrumentação , Termografia/métodos , Análise de Falha de Equipamento/instrumentação , Análise de Falha de Equipamento/métodos , Temperatura
8.
J Magn Reson Imaging ; 36(3): 714-21, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22649028

RESUMO

PURPOSE: To investigate the feasibility of 7 Tesla (T) nonenhanced high field MR imaging of the renal vasculature and to evaluate the diagnostic potential of various nonenhanced T1-weighted (T1w) sequences. MATERIALS AND METHODS: Twelve healthy volunteers were examined on a 7T whole-body MR system (Magnetom 7T, Siemens Healthcare Sector) using a custom-built eight-channel radiofrequency (RF) transmit/receive body coil. Subsequent to RF shimming, the following sequences were acquired (i) fat-saturated two-dimensional (2D) FLASH, (ii) fat-saturated 3D FLASH, and a (iii) fat-saturated 2D time-of-flight MR angiography (TOF MRA). SNR and CNR were measured in the aorta and both renal arteries. Qualitative analysis was performed with regard to vessel delineation (5-point scale: 5 = excellent to 1 = nondiagnostic) and presence of artifacts (5-point scale: 5 = no artifact present to 1 = strong impairment). RESULTS: The inherently high signal intensity of the renal arterial vasculature in T1w imaging enabled moderate to excellent vessel delineation in all sequences. Qualitative (mean, 4.7) and quantitative analysis (SNR(mean) : 53.9; CNR(mean) : 28.0) demonstrated the superiority of TOF MRA, whereas 2D FLASH imaging provided poorest vessel delineation and was most strongly impaired by artifacts (overall impairment 3.7). The 3D FLASH MRI demonstrated its potential for fast high quality imaging of the nonenhanced arterial vasculature, providing homogeneous hyperintense vessel signal. CONCLUSION: Nonenhanced T1w imaging in general and, TOF MRA in particular, appear to be promising techniques for good quality nonenhanced renal artery assessment at 7 Tesla.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Artéria Renal/anatomia & histologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Med Phys ; 38(5): 2795-805, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21776816

RESUMO

PURPOSE: The use of magnetic resonance (MR) radiofrequency (RF) surface coils is a prerequisite for high-quality positron emission tomography (PET)/MR imaging. In lack of in-gantry transmission (TX) sources, the exact position of the RF coils is unknown in PET/MR, and may, therefore, lead to false attenuation correction (AC) of the emission (EM) data. The authors assess lesion and background quantification in AC-PET by mimicking different PET/MR imaging situations using a whole-body (WB) PET-only tomograph. METHODS: Phantom experiments were performed on a PET tomograph with 68 Ge-rod TX sources. First, a 15-cm plastic cylinder was filled uniformly with [18F]-FDG to simulate a head study. Second, a NEMA NU-2001 image quality phantom (35 x 25 x 25 cm3) was filled uniformly with [18F]-FDG to simulate torso imaging. The phantom contained six lesions (10-38 mm diameter, lesion-to-background ratio 6:1) centred around a 5 cm diameter lung insert. EM and TX measurements were acquired with and without MR head (cylinder) and surface (NU-2001 phantom) RF coils in place. The following imaging situations were mimicked in both head and torso phantom studies: (1) PET scan without MR coils in EM and TX for reference, (2) PET scan with coils in both EM and TX, and (3) PET scan with coils in EM but without coils in TX. Two more set-ups were performed for the torso phantom: (4) PET scan with coils in EM only and phantom shifted slightly compared to (3), and (5) PET scan with coils in EM and TX following local displacement of the surface coils. PET EM data (1)-(4) were corrected for attenuation and scatter using cold TX data. Imaging situations (1)-(3) were repeated with the cylinder phantom and head coil in a combined PET/MR prototype system employing template-based AC. RESULTS: Head phantom: In case the MR head coils were not accounted for during AC (3), central and peripheral background activity concentration was underestimated by 13%-19% when compared to the reference setup (1). The effects of MR coil omission during AC was replicated in the repeat study with the combined PET/MR prototype. Torso phantom: All lesions were equally visible on all AC-PET images. The effects of disregarding MR surface RF coils during AC [(3) vs (1)] were 4%, or less. A slightly higher bias was observed when accounting for the RF surface coils that were shifted between EM and TX (5). The effect of coil misalignment and neglect during AC on the quantification of the simulated lungs was insignificant compared to the noise levels in AC-PET. CONCLUSIONS: Unaccounted attenuation from MR surface coils causes a regional bias of AC-PET data in body regions near the MR coils. Bias of central regions was more noticeable in smaller-size objects. In torso studies with body surface coils, the visibility of central lesions on PET was unaffected by MR coils following incomplete AC. Coil misalignment of several cm between emission and attenuation images causes an error that was comparable to that arising from unaccounted MR coil attenuation but small compared to the average standard deviation of the activity concentration levels.


Assuntos
Artefatos , Imageamento por Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Tomografia por Emissão de Pósitrons/instrumentação , Técnica de Subtração/instrumentação , Imagem Corporal Total/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
J Frailty Aging ; 8(1): 21-26, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30734827

RESUMO

BACKGROUND: Changes in muscle fat composition as for example observed in sarcopenia, affect physical performance and muscular function, like strength and power. OBJECTIVES: The purpose of this study was to compare 6-point Dixon magnetic resonance imaging and multi-echo magnetic resonance spectroscopy sequences to quantify muscle fat. Setting, participants and measurements: Two groups were recruited (G1: 23 healthy young men (28 ± 4 years), G2: 56 men with sarcopenia (80 ± 5 years)). Proton density fat fraction was measured with a 6-point product and a 6-point prototype Dixon sequence in the left thigh muscle and with a high-speed multi-echo T2*-corrected H1 magnetic resonance spectroscopy sequence within the semitendinosus muscle of the left thigh. To evaluate the comparability among the different methods, Bland-Altman and linear regression analyses of the proton density fat fraction results were performed. RESULTS: Mean differences ± 1.96 * standard deviation between spectroscopy and 6pt Dixon sequences were 1.9 ± 3.3% and 1.5 ± 3.6% for the product and prototype sequences, respectively. High correlations were measured between the proton density fat fraction results of the 6-point Dixon sequences and spectroscopy (R = 0.95 for the product sequence and R = 0.97 for the prototype sequence). CONCLUSIONS: Dixon imaging and spectroscopy sequences show comparable accuracy for fat measurements in the thigh. Spectroscopy is a local measurement, whereas Dixon sequences provide maps of the fat distribution. The high correlations of the 6-point Dixon sequences with spectroscopy support their clinical use. They provide higher spatial resolution than spectroscopy, but are not suitable for a more complicated spectral analysis to separate extra- and intramyocellular lipids.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Músculo Esquelético/diagnóstico por imagem , Sarcopenia/diagnóstico por imagem , Coxa da Perna/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Reprodutibilidade dos Testes , Adulto Jovem
11.
AJNR Am J Neuroradiol ; 40(7): 1106-1111, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31147351

RESUMO

BACKGROUND AND PURPOSE: The pathophysiology of wall contrast enhancement in thrombosed intracranial aneurysms is incompletely understood. This in vivo study aimed to investigate wall microstructures with gadolinium-enhanced 7T MR imaging. MATERIALS AND METHODS: Thirteen patients with 14 thrombosed intracranial aneurysms were evaluated using a 7T whole-body MR imaging system with nonenhanced and gadolinium-enhanced high-resolution MPRAGE. Tissue samples were available in 5 cases, and histopathologic findings were correlated with 7T MR imaging to identify the gadolinium-enhancing microstructures. RESULTS: Partial or complete inner wall enhancement correlated with neovascularization of the inner wall layer and the adjacent thrombus. Additional partial or complete outer wall enhancement can be explained by formation of vasa vasorum in the outer aneurysm wall layer. The double-rim enhancement correlated with perifocal edema and wall histologic findings suggestive of instability. CONCLUSIONS: Two distinct aneurysm wall microstructures responsible for gadolinium enhancement not depictable at lower spatial resolutions can be visualized in vivo using high-resolution gadolinium-enhanced 7T MR imaging.


Assuntos
Aneurisma Intracraniano/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Trombose/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Gadolínio , Humanos , Interpretação de Imagem Assistida por Computador , Aneurisma Intracraniano/patologia , Masculino , Pessoa de Meia-Idade , Trombose/patologia
12.
Mol Imaging Biol ; 20(1): 4-20, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28971346

RESUMO

The 6th annual meeting to address key issues in positron emission tomography (PET)/magnetic resonance imaging (MRI) was held again in Tübingen, Germany, from March 27 to 29, 2017. Over three days of invited plenary lectures, round table discussions and dialogue board deliberations, participants critically assessed the current state of PET/MRI, both clinically and as a research tool, and attempted to chart future directions. The meeting addressed the use of PET/MRI and workflows in oncology, neurosciences, infection, inflammation and chronic pain syndromes, as well as deeper discussions about how best to characterise the tumour microenvironment, optimise the complementary information available from PET and MRI, and how advanced data mining and bioinformatics, as well as information from liquid biomarkers (circulating tumour cells and nucleic acids) and pathology, can be integrated to give a more complete characterisation of disease phenotype. Some issues that have dominated previous meetings, such as the accuracy of MR-based attenuation correction (AC) of the PET scan, were finally put to rest as having been adequately addressed for the majority of clinical situations. Likewise, the ability to standardise PET systems for use in multicentre trials was confirmed, thus removing a perceived barrier to larger clinical imaging trials. The meeting openly questioned whether PET/MRI should, in all cases, be used as a whole-body imaging modality or whether in many circumstances it would best be employed to give an in-depth study of previously identified disease in a single organ or region. The meeting concluded that there is still much work to be done in the integration of data from different fields and in developing a common language for all stakeholders involved. In addition, the participants advocated joint training and education for individuals who engage in routine PET/MRI. It was agreed that PET/MRI can enhance our understanding of normal and disrupted biology, and we are in a position to describe the in vivo nature of disease processes, metabolism, evolution of cancer and the monitoring of response to pharmacological interventions and therapies. As such, PET/MRI is a key to advancing medicine and patient care.


Assuntos
Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Humanos , Biópsia Líquida , Radioterapia Guiada por Imagem , Microambiente Tumoral
13.
Phys Med Biol ; 63(1): 015014, 2017 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-29116052

RESUMO

The aim was to investigate the quantitative performance of 124I PET/MRI for pre-therapy lesion dosimetry in differentiated thyroid cancer (DTC). Phantom measurements were performed on a PET/MRI system (Biograph mMR, Siemens Healthcare) using 124I and 18F. The PET calibration factor and the influence of radiofrequency coil attenuation were determined using a cylindrical phantom homogeneously filled with radioactivity. The calibration factor was 1.00 ± 0.02 for 18F and 0.88 ± 0.02 for 124I. Near the radiofrequency surface coil an underestimation of less than 5% in radioactivity concentration was observed. Soft-tissue sphere recovery coefficients were determined using the NEMA IEC body phantom. Recovery coefficients were systematically higher for 18F than for 124I. In addition, the six spheres of the phantom were segmented using a PET-based iterative segmentation algorithm. For all 124I measurements, the deviations in segmented lesion volume and mean radioactivity concentration relative to the actual values were smaller than 15% and 25%, respectively. The effect of MR-based attenuation correction (three- and four-segment µ-maps) on bone lesion quantification was assessed using radioactive spheres filled with a K2HPO4 solution mimicking bone lesions. The four-segment µ-map resulted in an underestimation of the imaged radioactivity concentration of up to 15%, whereas the three-segment µ-map resulted in an overestimation of up to 10%. For twenty lesions identified in six patients, a comparison of 124I PET/MRI to PET/CT was performed with respect to segmented lesion volume and radioactivity concentration. The interclass correlation coefficients showed excellent agreement in segmented lesion volume and radioactivity concentration (0.999 and 0.95, respectively). In conclusion, it is feasible that accurate quantitative 124I PET/MRI could be used to perform radioiodine pre-therapy lesion dosimetry in DTC.


Assuntos
Neoplasias Ósseas/secundário , Radioisótopos do Iodo/uso terapêutico , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos , Radiometria/métodos , Neoplasias da Glândula Tireoide/patologia , Algoritmos , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/radioterapia , Diferenciação Celular , Humanos , Processamento de Imagem Assistida por Computador/métodos , Dosagem Radioterapêutica , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/radioterapia
14.
AJNR Am J Neuroradiol ; 37(4): 636-41, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26564437

RESUMO

Giant intracranial aneurysms are rare vascular pathologies associated with high morbidity and mortality. The purpose of this in vivo study was to assess giant intracranial aneurysms and their wall microstructure by 7T MR imaging, previously only visualized in histopathologic examinations. Seven giant intracranial aneurysms were evaluated, and 2 aneurysms were available for histopathologic examination. Six of 7 (85.7%) showed intraluminal thrombus of various sizes. Aneurysm walls were depicted as hypointense in TOF-MRA and SWI sequences with excellent contrast ratios to adjacent brain parenchyma (range, 0.01-0.60 and 0.58-0.96, respectively). The triple-layered microstructure of the aneurysm walls was visualized in all aneurysms in TOF-MRA and SWI. This could be related to iron deposition in the wall, similar to the findings in 2 available histopathologic specimens. In vivo 7T TOF-MRA and SWI can delineate the aneurysm wall and the triple-layered wall microstructure in giant intracranial aneurysms.


Assuntos
Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/patologia , Angiografia por Ressonância Magnética/métodos , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino
15.
Circulation ; 99(8): 1054-61, 1999 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-10051300

RESUMO

BACKGROUND: The individual makeup of atherosclerotic plaque has been identified as a dominant prognostic factor. With the use of an intravascular magnetic resonance (MR) catheter coil, we evaluated the effectiveness of high-resolution MR in the study of the development of atherosclerotic lesions in heritable hyperlipidemic rabbits. METHODS AND RESULTS: Sixteen hyperlipidemic rabbits were investigated at the ages of 6, 12, 24, and 36 months. The aorta was studied with digital subtraction angiography and high-resolution MR with the use of a surface coil and an intravascular coil that consisted of a single-loop copper wire integrated in a 5F balloon catheter. Images were correlated with histological sections regarding wall thickness, plaque area, and plaque components. Digital subtraction angiography revealed no abnormalities in the 6- and 12-month-old rabbits and only mild stenoses in the 24- and 36-month-old rabbits. High-resolution imaging with surface coils resulted in an in-plane resolution of 234x468 microm. Delineation of the vessel wall was not possible in younger rabbits and correlated only poorly with microscopic measurements in the 36-month-old rabbits. Intravascular images achieved an in-plane resolution of 117x156 microm. Increasing thickness of the aortic wall and plaque area was observed with increasing age. In the 24- and 36-month-old animals, calcification could be differentiated from fibrous and fatty tissue on the basis of the T2-fast spin echo images, as confirmed by histological correlation. CONCLUSIONS: Atherosclerotic evolution of hyperlipidemic rabbits can be monitored with high-resolution intravascular MR imaging. Image quality is sufficient to determine wall thickness and plaque area and to differentiate plaque components.


Assuntos
Arteriosclerose/diagnóstico , Animais , Arteriosclerose/genética , Feminino , Imageamento por Ressonância Magnética , Coelhos
16.
Phys Med Biol ; 60(12): 4731-52, 2015 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-26040657

RESUMO

A simulation toolkit, GATE (Geant4 Application for Tomographic Emission), was used to develop an accurate Monte Carlo (MC) simulation of a fully integrated 3T PET/MR hybrid imaging system (Siemens Biograph mMR). The PET/MR components of the Biograph mMR were simulated in order to allow a detailed study of variations of the system design on the PET performance, which are not easy to access and measure on a real PET/MR system. The 3T static magnetic field of the MR system was taken into account in all Monte Carlo simulations. The validation of the MC model was carried out against actual measurements performed on the PET/MR system by following the NEMA (National Electrical Manufacturers Association) NU 2-2007 standard. The comparison of simulated and experimental performance measurements included spatial resolution, sensitivity, scatter fraction, and count rate capability. The validated system model was then used for two different applications. The first application focused on investigating the effect of an extension of the PET field-of-view on the PET performance of the PET/MR system. The second application deals with simulating a modified system timing resolution and coincidence time window of the PET detector electronics in order to simulate time-of-flight (TOF) PET detection. A dedicated phantom was modeled to investigate the impact of TOF on overall PET image quality. Simulation results showed that the overall divergence between simulated and measured data was found to be less than 10%. Varying the detector geometry showed that the system sensitivity and noise equivalent count rate of the PET/MR system increased progressively with an increasing number of axial detector block rings, as to be expected. TOF-based PET reconstructions of the modeled phantom showed an improvement in signal-to-noise ratio and image contrast to the conventional non-TOF PET reconstructions. In conclusion, the validated MC simulation model of an integrated PET/MR system with an overall accuracy error of less than 10% can now be used for further MC simulation applications such as development of hardware components as well as for testing of new PET/MR software algorithms, such as assessment of point-spread function-based reconstruction algorithms.


Assuntos
Simulação por Computador , Imageamento por Ressonância Magnética/instrumentação , Modelos Teóricos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/instrumentação , Validação de Programas de Computador , Algoritmos , Humanos , Imageamento por Ressonância Magnética/métodos , Método de Monte Carlo , Tomografia por Emissão de Pósitrons/métodos , Razão Sinal-Ruído
17.
Rofo ; 187(9): 777-87, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26308534

RESUMO

UNLABELLED: The aim of this paper is to inform physicians, especially radiologists and cardiologists, about the technical and electrophysiological background of MR imaging of patients with implanted cardiac pacemakers (PM) and to provide dedicated clinical practice guidelines how to perform MR exams in this patient group. The presence of a conventional PM system is not any more considered an absolute contraindication for MR imaging. The prerequisites for MR imaging on pacemaker patients include the assessment of the individual risk/benefit ratio as well as to obtain full informed consent about the off label character of the procedure and all associated risks. Furthermore the use of special PM-related (e.g. re-programming of the PM) and MRI-related (e.g. limitation of whole body SAR to 2 W/kg) precautions is required and needs to be combined with adequate monitoring during MR imaging using continuous pulsoximetry. MR conditional PM devices are tested and approved for the use in the MR environment under certain conditions, including the field strength and gradient slew rate of the MR system, the maximum whole body SAR value and the presence of MR imaging exclusion zones. Safe MR imaging of patients with MR conditional PM requires the knowledge of the specific conditions of each PM system. If MR imaging within these specific conditions cannot be guaranteed in a given patient, the procedure guidelines for conventional PM should be used. The complexity of MR imaging of PM patients requires close cooperation of radiologists and cardiologists. KEY POINTS: Conventional pacemaker systems are no longer an absolute but rather a relative contraindication for performing an MR examination. The procedural management of conventional pacemaker includes the assessment of the individual risk/benefit ratio, comprehensive patient informed consent about specific related risks and "off label" use, extensive PM- and MRI-related safety precautions as well as adequate monitoring techniques during the MR exam. Decisive for patient safety are precise understanding of, and compliance with, the terms of use for the specific MR-conditional pacemaker system. If the electrophysiological and MRI-specific conditions for use of MR-conditional pacemakers are not met or compliance with these conditions for use cannot be guaranteed, the device must be treated like a conventional pacemaker.


Assuntos
Segurança de Equipamentos/normas , Imageamento por Ressonância Magnética/normas , Marca-Passo Artificial/normas , Segurança do Paciente/normas , Contraindicações , Alemanha , Humanos , Guias de Prática Clínica como Assunto , Radiologia/normas
18.
Mol Imaging Biol ; 17(3): 297-312, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25672749

RESUMO

This paper summarises the proceedings and discussions at the third annual workshop held in Tübingen, Germany, dedicated to the advancement of the technical, scientific and clinical applications of combined PET/MRI systems in humans. Two days of basic scientific and technical instructions with "hands-on" tutorials were followed by 3 days of invited presentations from active researchers in this and associated fields augmented by round-table discussions and dialogue boards with specific themes. These included the use of PET/MRI in paediatric oncology and in adult neurology, oncology and cardiology, the development of multi-parametric analyses, and efforts to standardise PET/MRI examinations to allow pooling of data for evaluating the technology. A poll taken on the final day demonstrated that over 50 % of those present felt that while PET/MRI technology underwent an inevitable slump after its much-anticipated initial launch, it was now entering a period of slow, progressive development, with new key applications emerging. In particular, researchers are focusing on exploiting the complementary nature of the physiological (PET) and biochemical (MRI/MRS) data within the morphological framework (MRI) that these devices can provide. Much of the discussion was summed up on the final day when one speaker commented on the state of PET/MRI: "the real work has just started".


Assuntos
Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Animais , Cardiologia/métodos , Alemanha , Humanos , Processamento de Imagem Assistida por Computador/métodos , Oncologia/métodos , Neurologia/métodos
19.
Mol Imaging Biol ; 17(5): 595-608, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26286794

RESUMO

This paper summarises key themes and discussions from the 4th international workshop dedicated to the advancement of the technical, scientific and clinical applications of combined positron emission tomography (PET)/magnetic resonance imaging (MRI) systems that was held in Tübingen, Germany, from February 23 to 27, 2015. Specifically, we summarise the three days of invited presentations from active researchers in this and associated fields augmented by round table discussions and dialogue boards with specific topics. These include the use of PET/MRI in cardiovascular disease, paediatrics, oncology, neurology and multi-parametric imaging, the latter of which was suggested as a key promoting factor for the wider adoption of integrated PET/MRI. Discussions throughout the workshop and a poll taken on the final day demonstrated that attendees felt more strongly that PET/MRI has further advanced in both technical versatility and acceptance by clinical and research-driven users from the status quo of last year. Still, with only minimal evidence of progress made in exploiting the true complementary nature of the PET and MRI-based information, PET/MRI is still yet to achieve its potential. In that regard, the conclusion of last year's meeting "the real work has just started" still holds true.


Assuntos
Imageamento por Ressonância Magnética , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Alemanha , Humanos
20.
Rofo ; 176(2): 163-9, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14872368

RESUMO

PURPOSE: To combine whole-body multi-station three-dimensional contrast enhanced magnetic resonance angiography (3D CE MRA) using a self-developed rolling table platform with parallel imaging strategies (PAT) in order to increase the spatial resolution of the 3D MRA data sets. MATERIALS AND METHODS: Whole-body multi-station MRA was performed with a rolling table platform (AngioSURF) on 5 volunteers in two imaging series: 1) standard imaging protocol, 2) modified high-resolution protocol employing PAT using the generalized autocalibrating partially parallel acquisitions (GRAPPA) algorithm with an acceleration factor of 3. For an intra-individual comparison of the two MR examinations, the arterial vasculature was divided into 30 segments. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were calculated for all 30 arterial segments of each subject. Vessel segment depiction was qualitatively assessed applying a 5-point scale to each of the segments. Image reconstruction times were recorded for the standard as well as the PAT protocol. RESULTS: Compared to the standard protocol, PAT allowed for increased spatial resolution through a 3-fold reduction in mean voxel size for each of the 5 stations. Mean SNR and CNR values over all specified vessel segments decreased by a factor of 1.58 and 1.56, respectively. Despite the reduced SNR and CNR, the depiction of all specified vessel segments increased in PAT images, reflecting the increased spatial resolution. Qualitative comparison of standard and PAT images showed an increase in vessel segment conspicuity with more detailed depiction of intramuscular arterial branches in all volunteers. The time for image data reconstruction of all 5 stations was significantly increased from about 10 minutes to 40 minutes when using the PAT acquisition. CONCLUSION: The implementation of PAT into the concept of whole-body MRA enabled to increase the spatial resolution in all examined territories, which resulted in more detailed MR angiograms.


Assuntos
Vasos Sanguíneos/anatomia & histologia , Angiografia por Ressonância Magnética/métodos , Adulto , Algoritmos , Meios de Contraste , Interpretação Estatística de Dados , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Angiografia por Ressonância Magnética/instrumentação , Masculino , Músculos/irrigação sanguínea , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA