RESUMO
Acute and late radiation-induced injury on skin and subcutaneous tissues are associated with substantial morbidity in radiation therapy, interventional procedures and also are of concern in the context of nuclear or radiological accidents. Pathogenesis is initiated by depletion of acutely responding epithelial tissues and damage to vascular endothelial microvessels. Efforts for medical management of severe radiation-induced lesions have been made. Nevertheless, the development of strategies to promote wound healing, including stem cell therapy, is required. From 1997 to 2014, over 248 patients were referred to the Radiopathology Committee of Hospital de Quemados del Gobierno de la Ciudad de Buenos Aires (Burns Hospital) for the diagnosis and therapy of radiation-induced localized lesions. As part of the strategies for the management of severe cases, there is an ongoing research and development protocol on 'Translational Clinical Trial phases I/II to evaluate the safety and efficacy of adult mesenchymal stem cells from bone marrow for the treatment of large burns and radiological lesions'. The object of this work was to describe the actions carried out by the Radiopathology Committee of the Burns Hospital in a chronic case with more than 30 years of evolution without positive response to conventional treatments. The approach involved the evaluation of the tissular compromise of the lesion, the prognosis and the personalized treatment, including regenerative therapy.
Assuntos
Queimaduras/terapia , Hemangioma/radioterapia , Transplante de Células-Tronco Mesenquimais/métodos , Lesões por Radiação/terapia , Pele/lesões , Tecido Adiposo/citologia , Idoso , Argentina , Cadáver , Ensaios Clínicos como Assunto , Hemangioma/complicações , Hospitais , Humanos , Masculino , Células-Tronco Mesenquimais/citologia , Prognóstico , Lesões por Radiação/patologia , Radioterapia/efeitos adversos , Pele/efeitos da radiação , CicatrizaçãoRESUMO
Biological Dosimetry is a necessary support for national radiation protection programmes and emergency response schemes. The Latin American Biological Dosimetry Network (LBDNet) was formally founded in 2007 to provide early biological dosimetry assistance in case of radiation emergencies in the Latin American Region. Here are presented the main topics considered in the foundational document of the network, which comprise: mission, partners, concept of operation, including the mechanism to request support for biological dosimetry assistance in the region, and the network capabilities. The process for network activation and the role of the coordinating laboratory during biological dosimetry emergency response is also presented. This information is preceded by historical remarks on biological dosimetry cooperation in Latin America. A summary of the main experimental and practical results already obtained by the LBDNet is also included.
Assuntos
Proteção Radiológica/métodos , Liberação Nociva de Radioativos/prevenção & controle , Radiometria/métodos , Planejamento em Desastres/métodos , Humanos , Agências Internacionais , Cooperação Internacional , América LatinaRESUMO
The bottleneck in data acquisition during biological dosimetry based on a dicentric assay is the need to score dicentrics in a large number of lymphocytes. One way to increase the capacity of a given laboratory is to use the ability of skilled operators from other laboratories. This can be done using image analysis systems and distributing images all around the world. Two exercises were conducted to test the efficiency of such an approach involving 10 laboratories. During the first exercise (E1), the participant laboratories analysed the same images derived from cells exposed to 0.5 and 3 Gy; 100 images were sent to all participants for both doses. Whatever the dose, only about half of the cells were complete with well-spread metaphases suitable for analysis. A coefficient of variation (CV) on the standard deviation of â¼15 % was obtained for both doses. The trueness was better for 3 Gy (0.6 %) than for 0.5 Gy (37.8 %). The number of estimated doses classified as satisfactory according to the z-score was 3 at 0.5 Gy and 8 at 3 Gy for 10 dose estimations. In the second exercise, an emergency situation was tested, each laboratory was required to score a different set of 50 images in 2 d extracted from 500 downloaded images derived from cells exposed to 0.5 Gy. Then the remaining 450 images had to be scored within a week. Using 50 different images, the CV on the estimated doses (79.2 %) was not as good as in E1, probably associated to a lower number of cells analysed (50 vs. 100) or from the fact that laboratories analysed a different set of images. The trueness for the dose was better after scoring 500 cells (22.5 %) than after 50 cells (26.8 %). For the 10 dose estimations, the number of doses classified as satisfactory according to the z-score was 9, for both 50 and 500 cells. Overall, the results obtained support the feasibility of networking using electronically transmitted images. However, before its implementation some issues should be elucidated, such as the number and resolution of the images to be sent, and the harmonisation of the scoring criteria. Additionally, a global website able to be used for the different regional networks, like Share Points, will be desirable to facilitate worldwide communication.
Assuntos
Aberrações Cromossômicas/efeitos da radiação , Cromossomos Humanos/efeitos da radiação , Raios gama/efeitos adversos , Laboratórios/normas , Linfócitos/efeitos da radiação , Bioensaio , Relação Dose-Resposta à Radiação , Humanos , RadiometriaRESUMO
Well-defined protocols and quality management standards are indispensable for biological dosimetry laboratories. Participation in periodic proficiency testing by interlaboratory comparisons is also required. This harmonization is essential if a cooperative network is used to respond to a mass casualty event. Here we present an international intercomparison based on dicentric chromosome analysis for dose assessment performed in the framework of the IAEA Regional Latin American RLA/9/054 Project. The exercise involved 14 laboratories, 8 from Latin America and 6 from Europe. The performance of each laboratory and the reproducibility of the exercise were evaluated using robust methods described in ISO standards. The study was based on the analysis of slides from samples irradiated with 0.75 (DI) and 2.5 Gy (DII). Laboratories were required to score the frequency of dicentrics and convert them to estimated doses, using their own dose-effect curves, after the analysis of 50 or 100 cells (triage mode) and after conventional scoring of 500 cells or 100 dicentrics. In the conntional scoring, at both doses, all reported frequencies were considered as satisfactory, and two reported doses were considered as questionable. The analysis of the data dispersion among the dicentric frequencies and among doses indicated a better reproducibility for estimated doses (15.6% for DI and 8.8% for DII) than for frequencies (24.4% for DI and 11.4% for DII), expressed by the coefficient of variation. In the two triage modes, although robust analysis classified some reported frequencies or doses as unsatisfactory or questionable, all estimated doses were in agreement with the accepted error of ±0.5 Gy. However, at the DI dose and for 50 scored cells, 5 out of the 14 reported confidence intervals that included zero dose and could be interpreted as false negatives. This improved with 100 cells, where only one confidence interval included zero dose. At the DII dose, all estimations fell within ±0.5 Gy of the reference dose interval. The results obtained in this triage exercise indicated that it is better to report doses than frequencies. Overall, in both triage and conventional scoring modes, the laboratory performances were satisfactory for mutual cooperation purposes. These data reinforce the view that collaborative networking in the case of a mass casualty event can be successful.