Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Medicina (Kaunas) ; 60(4)2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38674172

RESUMO

Arterial occlusions of the retina are potentially sight-threatening diseases which often result in profound visual loss. The aim of this narrative review is to provide an overview of the aetiology, discuss major risk factors, describe the management and systemic assessments and evaluate existing therapies. For this review, an extensive literature search in PubMed was performed. Emboli from the heart or the carotid arteries can cause ophthalmic artery occlusion (OAO), central retinal artery occlusion (CRAO) and branch retinal artery occlusion (BRAO). Most patients with arterial occlusions have vascular risk factors such as arterial hypertension, hyperhomocysteinaemia, carotid stenosis and atrial fibrillation, which also increase the risk of cerebral stroke and myocardial infarction. Therapies such as ocular massage, thrombolysis and anterior chamber paracentesis have been suggested but are still equivocal. However, it is evident that retinal artery occlusion should be immediately treated and accompanied by interdisciplinary collaboration, since early diagnosis and the proper treatment of possible risk factors are important to reduce the risk of further damage, recurrences, other vascular diseases and mortality.


Assuntos
Oclusão da Artéria Retiniana , Humanos , Oclusão da Artéria Retiniana/diagnóstico , Oclusão da Artéria Retiniana/etiologia , Oclusão da Artéria Retiniana/terapia , Fatores de Risco , Hipertensão/complicações , Hipertensão/terapia
2.
Graefes Arch Clin Exp Ophthalmol ; 260(10): 3387-3394, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35471739

RESUMO

PURPOSE: To investigate the effect of font choice on reading parameters by using the RADNER Reading Charts printed in two fonts (Helvetica vs. Times Roman) equalized in terms of x-height. METHODS: This is a cross-sectional study of 40 participants with healthy eyes (18 to 60 years of age; mean: 42.13 ± 12.28 years). Reading performance was evaluated binocularly with RADNER Reading Charts printed in either Helvetica Neue (T1) Roman sans serif (Adobe) or Times New Roman PS Roman serif (Adobe). The test distance was 40 cm. Reading charts were presented in random order. Reading acuity (RA), mean reading speed of all sentences read (MEAN-ALL RS), mean reading speed from 0.8 logRAD to 0.3 logRAD (MEAN-RS), maximum reading speed (MAX-RS), and critical print size (CPS) were compared. RESULTS: The RA values obtained for the Helvetica and Times Roman fonts (in full logarithmic units of 0.1 logRAD) did not differ between the two fonts (mean for both fonts: - 0.128 ± 0.064 logRAD; 95% CI for both: - 0.148; - 0.107 logRAD). The differences in all other reading parameters between the two fonts were small and not statistically significant. The analyses revealed narrow confidence intervals and good coefficients of reliability. Except for the CPS (r = 0.49) and RA (equal for Helvetica and Times Roman), the correlations for all parameters were high, ranging from r = 0.92 to r = 0.98. CONCLUSION: The equivalent reading performance obtained with Helvetica and Times Roman (when equalized in x-height and layout) makes these font types interchangeable as standards for reading charts.


Assuntos
Leitura , Testes Visuais , Adulto , Estudos Transversais , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Acuidade Visual
3.
Ophthalmic Physiol Opt ; 42(6): 1180-1186, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35972034

RESUMO

PURPOSE: The purpose was to compare systematically the legibility of a font without serifs (Helvetica) and one with serifs (Times New Roman). METHODS: Three paragraphs that were equal in the number of words, syllables, characters, difficulty and reading length were printed at equal size, with equal spacing between the lines and equal layout (paperback style), in either the sans serif typeface Helvetica Neue T1 55 Roman (Adobe) or the serif typeface Times New Roman PS Roman (Adobe). They were also printed in newspaper format in the serif font. The paragraphs were presented in random order (Latin square design) to 36 participants between 18 and 38 years of age (wearing their best-corrected visual acuity). Reading duration was measured with a stopwatch. Reading time, reading speed and the number of reading errors were compared. RESULTS: For the paperback layout, no significant difference in reading time (p = 0.50) or reading speed (p = 0.56) was found between the two fonts. The correlation between the two fonts was high for both reading time and speed (r = 0.93). The mean number of reading errors was the same (0.31 ± 0.58 errors/text) for both fonts. There was a significant difference in reading time and speed between the paperback and the newspaper layout. CONCLUSION: The legibility of Helvetica and Times New Roman is similar when investigated under equivalent conditions. Thus, these two font types can be used as interchangeable standard typefaces.

4.
Graefes Arch Clin Exp Ophthalmol ; 257(6): 1295-1301, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30989362

RESUMO

PURPOSE: To investigate the age-related course of best-corrected visual acuity in healthy eyes. METHODS: Two hundred participants (400 eyes) 25 to 74 years of age (114 females, 86 males) were investigated, 20 per 5-year age group. Best-corrected visual acuity was measured monocularly with the ETDRS 2000 charts at a distance of 4 m (Precision Vision, Woodstock, IL, USA). Strict exclusion and termination criteria were used. RESULTS: Visual acuity did not change between ages 25 and 54 years (mean of the better eyes, - 0.18 ± 0.05 logMAR). A significant age-related break-point in visual acuity was found at the ages of 55-59 years. For all age groups, the overall mean visual acuity was - 0.15 ± 0.06 logMAR for the better eyes and - 0.13 ± 0.06 logMAR for the worse eyes. There was no difference between the right and left eyes (- 0.14 ± 0.06 logMAR). The visual acuity was better in the right eye in 29% (n = 58) of the participants, better in the left eye in 32% (n = 64), and the same in both eyes in 39% (n = 78). From ages 25 to 64 years, neither the better nor the worse eye had a visual acuity worse than 0.0 logMAR. CONCLUSION: Best-corrected visual acuity was constantly high until the age of 54 years. An age-related break-point appeared at 55 to 59 years of age. Until age 64, a minimal angle of resolution smaller than 1 min of arc (visual acuity better 0.0 logMAR) can be expected in healthy eyes.


Assuntos
Envelhecimento/fisiologia , Visão Monocular/fisiologia , Acuidade Visual/fisiologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Testes Visuais/métodos
5.
Optom Vis Sci ; 96(10): 768-779, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31592960

RESUMO

This review gives an overview of the current status of standardization by statistical evaluation of reading charts. First begun only 20 years ago, the statistical evaluation of reading charts now reflects an increasing clinical and scientific interest in standardized, comparable, and reproducible reading charts.For clinical or research purposes in human subjects, standardization of psychophysical tests and their test items by statistical evaluation is mandatory because it provides experimental control. Initial attempts at reading chart standardization were made by characterizing the test items, either in terms of a selection of unrelated words or in terms of sentences representing a constant number of characters, including spaces. As initiated by the RADNER Reading Charts, standardization of reading charts (and test items) by statistical evaluation has gained increasing clinical and scientific interest in the last two decades and has later also been applied to some of the other modern reading charts. A literature search was performed with respect to reading charts that (a) have been produced in accordance with the recommendations of the International Council of Ophthalmology (geometrical print size progression), (b) have been statistically analyzed, and/or (c) use clearly characterized test items (conceptually and statistically). These reading charts are as follows: the Bailey-Lovie Word Reading Charts, the Colenbrander Cards, the RADNER Reading Charts, the MNREAD Acuity Charts, the Smith-Kettlewell Reading Test (SKread Test), the C-Read Charts, and the Balsam Alabdulkader-Leat (BAL) Chart. The test items of these charts have been characterized either empirically or by statistical analysis and selection. The extent of the statistical evaluation of the reading charts varies. Despite their different methodological approaches, these reading charts represent an advancement that has made possible the useful comparison and reproducible evaluation of near visual performance.


Assuntos
Leitura , Testes Visuais/normas , Humanos , Idioma , Oftalmologia , Testes Visuais/instrumentação
7.
Graefes Arch Clin Exp Ophthalmol ; 254(1): 177-84, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26542120

RESUMO

PURPOSE: To investigate the reliability, validity, and statistical comparability of long paragraphs that were developed to be equivalent in construction and difficulty. METHODS: Seven long paragraphs were developed that were equal in syntax, morphology, and number and position of words (111), with the same number of syllables (179) and number of characters (660). For validity analyses, the paragraphs were compared with the mean reading speed of a set of seven sentence optotypes of the RADNER Reading Charts (mean of 7 × 14 = 98 words read). Reliability analyses were performed by calculating the Cronbach's alpha value and the corrected total item correlation. Sixty participants (aged 20-77 years) read the paragraphs and the sentences (distance 40 cm; font: Times New Roman 12 pt). Test items were presented randomly; reading length was measured with a stopwatch. RESULTS: Reliability analysis yielded a Cronbach's alpha value of 0.988. When the long paragraphs were compared in pairwise fashion, significant differences were found in 13 of the 21 pairs (p < 0.05). In two sequences of three paragraphs each and in eight pairs of paragraphs, the paragraphs did not differ significantly, and these paragraph combinations are therefore suitable for comparative research studies. The mean reading speed was 173.34 ± 24.01 words per minute (wpm) for the long paragraphs and 198.26 ± 28.60 wpm for the sentence optotypes. The maximum difference in reading speed was 5.55 % for the long paragraphs and 2.95 % for the short sentence optotypes. The correlation between long paragraphs and sentence optotypes was high (r = 0.9243). CONCLUSIONS: Despite good reliability and equivalence in construction and degree of difficulty, a statistically significant difference in reading speed can occur between long paragraphs. Since statistical significance should be dependent only on the persons tested, either standardizing long paragraphs for statistical equality of reading speed measurements or increasing the number of presented paragraphs is recommended for comparative investigations.


Assuntos
Leitura , Testes Visuais/instrumentação , Testes Visuais/normas , Acuidade Visual/fisiologia , Adulto , Extração de Catarata , Feminino , Humanos , Idioma , Masculino , Pessoa de Meia-Idade , Pseudofacia/fisiopatologia , Reprodutibilidade dos Testes , Visão Binocular/fisiologia , Vocabulário , Adulto Jovem
8.
Prog Retin Eye Res ; 101: 101262, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38574851

RESUMO

Patients who suffer from sight-threatening eye diseases share a desire to regain a comfortable reading ability. In light of the modern advances achieved in ophthalmic diagnosis and therapy, and because a significant lack of comparability between reading charts still exists, there is an increasing need for a worldwide standard in the form of a norm for diagnostic reading charts. Already, applied advancements such as digital print, which allow a calibration of the print sizes of reading charts in correctly progressing geometric proportions by using the actual height of a lower case "x" in millimeters (x-height), and psychophysically standardizing reading charts and their test items by applying modern statistical methods have significantly contributed to establishing a norm for reading charts. In 2020, a proposal of the British delegation was accepted by the International Organization for Standardization (ISO) group "Visual Optics and Optical Instruments," and a working group was established. Bearing in mind the efforts of the ISO with regard to an international norm, this review article is intended to (a) give an overview of the historical background and related normative approaches for diagnostic reading tests used in ophthalmology and optometry, (b) explain psychophysical and technical concerns, and (c) discuss the possibilities and limits of concepts that seem relevant to developing a modern standard for reading charts.


Assuntos
Leitura , Testes Visuais , Humanos , Testes Visuais/métodos , Testes Visuais/normas , Acuidade Visual/fisiologia , Oftalmologia/normas , Padrões de Referência
9.
Eye Vis (Lond) ; 9(1): 31, 2022 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-35965343

RESUMO

PURPOSE: To evaluate microscopically whether the print quality and accuracy of sizing of Landolt ring near vision charts are adequate for the calibration of reading charts. METHODS: Near vision charts with Landolt rings from Oculus GmbH (C-Test; Wetzlar, Germany), Precision Vision (Woodstock, IL) and the RADNER Charts were examined, as well as custom-made Landolt rings optimized for print quality. Microscopic investigations and measurements were performed by using a Huvitz HSZ 600 stereomicroscope (Nikon NIS Elements software) to evaluate the height of the Landolt rings, the thickness of the lines, and the width of the openings. The deviations from the mathematically correct values, which were calculated as given in the EN/ISO 8596 and by the International Council of Ophthalmology (ICO), were analyzed (calculated for a test distance of 40 cm). RESULTS: All the near vision charts showed notable deficiencies in print quality and aberrations from the nominal values in the height, thickness of the lines, and width of the openings. The openings were too narrow, whereas the height and thickness of the lines were larger than the nominal values. Even the openings of Landolt rings optimized for print quality were not always within an acceptable 5% tolerance and need further improvement. CONCLUSION: This study reports inaccuracies in the heights, thicknesses of the lines, and widths of the openings of Landolt rings in all the near vision charts investigated. The extent of these inaccuracies excludes such near vision charts as reference tests for the calibration of reading charts. The x-height in relation to the visual angle still seems to be the most reliable method for standardizing the print sizes for reading charts.

11.
Br J Ophthalmol ; 103(10): 1518-1523, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30573497

RESUMO

PURPOSE: To assess age-related differences in baseline measures of reading performance obtained from the RADNER Reading Charts in healthy eyes with best corrected (ETDRS) distance acuity. METHODS: Cross-sectional study of participants (n=200) aged 25-74 years (n=20 per 5 years age group). Best corrected distance visual acuity was measured monocularly with ETDRS 2000 Charts. Reading performance was evaluated binocularly with the RADNER Reading Charts. Reading acuity (RA), reading acuity score (RA score), mean reading speed (MEAN-RS), maximum reading speed, reading speed with a long paragraph, critical print size (CPS) and the logMAR/logRAD ratio were analysed. RESULTS: RA, RA score, CPS-1 (last logRAD with normal reading speed) and ETDRS acuity did not change significantly between age 25 and 54 years. Overall, the mean RA was -0.091±0.07 logRAD, and the RA score was -0.069±0.07 logRAD. The mean difference between the RA and best ETDRS acuity was 0.0603±0.055 logMAR (r=0.62; p<0.05). The logMAR/logRAD ratio was 87.75%±11.23%. The MEAN-RS ranged from 189±21.9 words per minute (wpm) for the group aged 70-74 years to 236±22.5 wpm for the group aged 40-44 years and correlated well with the long paragraph results (r=0.87). CONCLUSION: Best corrected RA, reading speed and ETDRS distance acuity were constant until the age of 54 years. An age-related break point was found between the groups aged 50-54 years and 55-59 years; for reading speed, the break point can be assumed to be within the age range of 50-54 years.


Assuntos
Envelhecimento/fisiologia , Leitura , Testes Visuais/instrumentação , Acuidade Visual/fisiologia , Adulto , Idoso , Estudos Transversais , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
12.
Surv Ophthalmol ; 64(1): 90-100, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30189234

RESUMO

PURPOSE: To present an overview of contemporary methods and metrics used to measure near vision, intermediate vision, and accommodation. METHODS: A search in PubMed was performed with the following key phrases: near vision, intermediate vision, objective and subjective methods for the measurement of accommodation. For subjective methods, we included only those that are most widely used, had a scientific evidence of its outcomes, and have an easy availability at the doctor's office. For objective methods, we included those aberrometers or autorefractometers that have been proven to give good repeatability and reproducibility in the study of changes in optical power of the eye along the accommodative process. RESULTS: Near vision should be tested at 40 cm and intermediate vision at 63 or 80 cm. Accommodation should be measured with objective methods such as autorefractometers or aberrometers. CONCLUSIONS: The standardization for the measurement of near and intermediate vision, as well as the reading charts, will facilitate the comparison of visual outcomes between studies. Measurement of accommodation should be performed with objective methods as subjective methods tend to overestimate the accommodative power.


Assuntos
Acomodação Ocular/fisiologia , Leitura , Refração Ocular/fisiologia , Testes Visuais/métodos , Acuidade Visual/fisiologia , Humanos
13.
J Cataract Refract Surg ; 34(4): 638-42, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18361987

RESUMO

PURPOSE: To develop 24 short Spanish optotype sentences for the construction of a test based on the Radner reading test to simultaneously measure near visual acuity and reading speed. SETTING: Department of Refractive Surgery, Vissum-Instituto de Oftalmológico de Alicante, Alicante, Spain. METHODS: Thirty-one sentences were constructed in Spanish following the procedure defined by Radner to obtain sentence optotypes with comparable structure and the same lexical and grammatical difficulty. Sentences were statistically selected and standardized in 60 patients divided into 2 groups by educational level. Group A (30 patients) had a university education and Group B (30 patients), a primary school education. The interval of reading time was defined as the overall mean +/-1.1 x SD. All sentences with a mean between 3.59 seconds and 4.04 seconds were selected for the reading charts. RESULTS: The mean age was 30.8 years +/- 6.2 (SD) in Group A and 37.3 +/- 10.7 years in Group B. The mean reading time was 3.8 +/- 0.9 seconds in all patients, 3.5 +/- 0.6 seconds in Group A, and 4.1 +/- 1.0 seconds in Group B. CONCLUSION: The 24 short single Spanish sentences were highly comparable in syntactical structure; number, position, and length of words; lexical difficulty; and reading length.


Assuntos
Leitura , Testes Visuais/métodos , Acuidade Visual/fisiologia , Vocabulário , Adulto , Escolaridade , Humanos , Idioma
14.
Br J Ophthalmol ; 101(3): 239-243, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27881374

RESUMO

PURPOSE: To add a new set of 24 sentence optotypes to the German version of the RADNER reading charts and to investigate whether sentences constructed based upon an optimised concept of sentence optotypes can be used together with the original 38 sentences. METHODS: Twenty-eight optimised sentence optotypes were constructed based upon the concept of sentence optotypes as established for the RADNER Reading Charts, with words having the same number of characters and syllables being placed in the same positions. The best comparable sentences were statistically selected in 30 volunteers. Reading speed and the number of errors were determined. Validity was analysed in comparison to a 111-word long standardised paragraph and 7 of the 38 original sentence optotypes. RESULTS: The mean reading speed obtained with the 28 sentences was 192.30±26.69 words per minute (wpm), as compared with 192.47±25.32 wpm for the 7 original sentence optotypes and 165.28±20.82 wpm for the long paragraph; 24 of the 28 optimised sentences met our selection criteria for reading speed/time (mean reading speed: 192.41±26.58). The mean number of reading errors was 0.10±0.30. The correlation between the 24 optimised sentence optotypes and the long paragraph was r=0.90. Reliability analyses yielded an overall Cronbach's α coefficient of 0.992. CONCLUSION: The 24 new sentence optotypes can be integrated into the existing set of 38 original sentences. Since all the statistical results obtained were similar to those of the original sentences, the best possible reliability had apparently already been achieved with the original sentence optotypes.


Assuntos
Idioma , Leitura , Testes Visuais/instrumentação , Visão Binocular/fisiologia , Vocabulário , Adolescente , Adulto , Idoso , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Reprodutibilidade dos Testes , Testes Visuais/métodos , Acuidade Visual/fisiologia
15.
Acta Ophthalmol ; 95(2): 211-216, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27572996

RESUMO

PURPOSE: To compare the reading time and reading speed measurements obtained with a stopwatch with those of an automated computer program for measuring reading speed and acuity (rad-rd© ; patent: AT 504635B1/10-2006). METHODS: The rad-rd© was used (in conjunction with a PC and microphone) for the computer-based measurements. In rotation, each of four examiners took a turn reading the 12 sentences from one of the four RADNER Reading Charts to three other examiners, who served as stoppers. The stoppers simultaneously measured the reading time with a stopwatch while a fifth investigator used the rad-rd© to obtain computerized measurements. The stopwatch measurements were then statistically compared with the rad-rd© measurements. RESULTS: The mean reading time obtained with the stopwatch measurements was 4.34 ± 0.57 seconds (196.21 ± 21.79 wpm), versus 4.44 ± 0.59 seconds (192.24 ± 22.20 wpm) by computer measurement (r = 0.84). Of the 144 stopwatch measurements, 97 (67.36%) were shorter, and 47 (32.64%) were equal to (n = 5) or longer than the computer measurements. The mean difference for the shorter measurements was -0.17 ± 0.1 seconds (3.91% of the mean reading time), and the mean difference for the longer measurements was 0.11 ± 0.1 seconds (2.53% of the mean reading time). Most differences ranged from -0.1 to 0.1 seconds (42.36%). The results did not differ significantly among the four stoppers. CONCLUSION: The rad-rd© is an accurate, automated computer program for measuring reading time. Stopwatch measurements, although subject to inaccuracy from several sources, remain a reliable and simple method for analysis of reading performance.


Assuntos
Biometria/métodos , Leitura , Software , Testes Visuais/métodos , Acuidade Visual/fisiologia , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes
16.
Am J Ophthalmol ; 142(4): 620-4, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17011854

RESUMO

PURPOSE: To evaluate the extent of the visual impairment caused by uveitis-associated cystoid macular edema (CME) and compare the results with lesion size. DESIGN: Observational case series. METHODS: setting: Uveitis outpatient clinic of the Department of Ophthalmology and Optometry, Medical University of Vienna. patient population: CME was verified in 30 eyes of 30 consecutive uveitis patients with optical coherence tomography and lesion size was assessed with retinal thickness analyzer. main outcome measures: Distance visual acuity (VA) (measured with Early Treatment Diabetic Retinopathy Study charts), reading acuity, and reading speed (tested with Radner Reading Charts). Results were compared with nonaffected partner eyes. RESULTS: Distance VA was logMAR 0.22 +/- 0.15 in CME eyes vs -0.02 +/- 0.17 in healthy controls. Reading acuity was 75% of logMAR in CME eyes vs 92% of logMAR in control eyes (P = .01). The mean reading speed was 148.4 +/- 36.6 words per minute in patients with CME vs 168.9 +/- 36.3 in patients without CME (P = .04). Reading acuity correlated with both lesion size and distance VA (r = 0.61; P = .01 and r = 0.53; P = .028, respectively). Neither anatomical classification of uveitis nor gender or age had a significant influence on the evaluated parameters. CONCLUSIONS: Reading acuity and reading speed were considerably more impaired than distance visual acuity. The assessed parameters showed a better correlation to lesion size and seem to be a better reflection of macular dysfunction. Analyzing reading function is an important factor when following patients with CME and evaluating success of treatment modalities.


Assuntos
Dislexia/fisiopatologia , Edema Macular/fisiopatologia , Leitura , Uveíte/fisiopatologia , Adolescente , Adulto , Criança , Feminino , Humanos , Edema Macular/diagnóstico , Masculino , Pessoa de Meia-Idade , Tomografia de Coerência Óptica , Testes Visuais/instrumentação , Acuidade Visual
17.
Eye Vis (Lond) ; 3: 29, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27844022

RESUMO

Presbyopia correction is mainly concerned with the goal of regaining an uncorrected reading performance. Since historic reading charts do not provide a unique standard that is applicable for the analysis of clinical and scientific reading performance, new standardized reading charts have been developed, in order to provide reading performance analyses analogous to modern single-optotype distance acuity measurements: the Bailey-Lovie Word Reading Chart, the Colenbrander English Continuous Text Near Vision Cards, the MNREAD Charts, and the RADNER Reading Charts. The last three are also meant to measure reading speed, thus allowing detailed analysis of the reading capabilities of the patient's functional vision. Furthermore, these reading charts can be declared homologated, based on the standards that were published for reading charts by the Visual Function Committee of the International Council of Ophthalmology (ICO) in 1988. Many research studies have shown that by analyzing the reading performance with homologated reading charts, valuable insight into the reading performance of patients suffering from various diseases can be obtained. These reading charts have also been successfully used in presbyopia research. It therefore seems evident that homologated, standardized reading charts facilitate not only research concerning functional vision in many fields of ophthalmology but also international communication about near visual performance. Homologated reading charts are available in almost all languages and have become a valuable tool in analyzing reading performance. We argue in this review that homologated reading charts are clearly a necessity for presbyopia research.

18.
Acta Ophthalmol ; 94(2): 182-6, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26408429

RESUMO

PURPOSE: To develop 28 short texts to be used as sentence optotypes in a Danish version of the Radner Reading Chart for the measurement of reading acuity and speed. METHOD: Forty-six short texts of comparable lexical and grammatical difficulty were constructed. The short texts were tested together with two longer reference texts in 100 persons with visual acuity 6/6, of which 50 were university students (age: 24.7 ± 3.1 years, 36% males) and 50 were blue-collar workers (37.2 ± 13.4 years, 54% males). Study parameters were mean reading speed and error rate per participant, and mean reading time, variance and number of errors per short text. RESULTS: The students read the short texts faster than the blue-collar workers (184 ± 21.4 words per minute (wpm) versus 163 ± 26.3 wpm, p < 0.0001). There was a high correlation between the reference texts and the short texts [Pearson's correlation coefficient = 0.89 (95% CI 0.83-0.92)]. The mean reading time for each of the short texts ranged from 4.4 s to 5.8 s with a mean of 4.96 ± 0.35 s, and the median number of errors was eight. Twenty-eight short texts were selected for sentence optotypes with mean reading times between 4.6 s and 5.2 s, a mean standard deviation of 1.2 s or less and a number of errors of 17 per 100 persons or less. CONCLUSION: Reading time uniformity in the Danish version of the Radner Reading Chart was comparable to that of the original German version. Education had an influence on reading performance that may warrant stratification for this parameter when reading tests are used in clinical trials.


Assuntos
Leitura , Testes Visuais/instrumentação , Acuidade Visual/fisiologia , Vocabulário , Adulto , Dinamarca , Escolaridade , Feminino , Humanos , Masculino , Adulto Jovem
19.
Arq Bras Oftalmol ; 79(4): 238-42, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27626148

RESUMO

PURPOSE: To develop 27 short sentence optotypes for the Portuguese version of the Radner Reading Charts. METHODS: Thirty-four Portuguese sentences were constructed following the concept of the Radner Reading Charts to obtain highly comparable sentences in terms of lexical difficulty, syntactical complexity, word length, number of syllables, and position of words. A long text (106 words) at the 5th grade reading level was also tested to assess the validity of the reading speeds obtained with the short sentences. The short sentences and long text were tested in 50 volunteers with similar educational backgrounds (mean age 30.98 years ± 6.99 years, range 19-47 years). Reading speeds were measured with a stop-watch and reported as words per minute (wpm). The reading time for each of the short sentences to be selected for the chart was defined as falling within the range of the mean ± 0.40 × standard deviation (SD). RESULTS: The overall mean reading speed for each of the short sentences was 235.43 ± 36.39 wpm. The 27 sentences with a mean between 220.8 and 250.0 wpm (overall mean ± 0.40 × SD) were selected for construction of the reading charts. The mean reading speed for the long text was 212.42 ± 26.20 wpm. Correlation between the selected short sentences and long text was high (r =0.86). Reliability analysis yielded an overall Cronbach's alpha coefficient of 0.97. CONCLUSIONS: The 27 short Portuguese sentences were highly comparable in terms of syntactical structure, number, position and length of words, lexical difficulty, and reading length. This reading test can overcome the limitations of the current tests for homogeneity and comparability, reducing subjectivity in the evaluation of the functional outcomes of medical and surgical ophthalmologic treatments.


Assuntos
Idioma , Leitura , Testes Visuais/métodos , Testes Visuais/normas , Adulto , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Portugal , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Fatores de Tempo , Acuidade Visual
20.
J Cataract Refract Surg ; 31(11): 2111-9, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16412924

RESUMO

PURPOSE: To determine whether preoperative reading tests can be used for differentiating visual impairments with regard to the diagnosis of cataract and age-related macular degeneration (ARMD). SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. METHODS: Reading performance of patients with nuclear cataract, posterior subcapsular cataract, and ARMD were evaluated with respect to reading acuity, maximum reading speed, and critical print size; normal-sighted participants were tested as controls. A multivariate discriminant analysis of the 4 groups (100 eyes of 100 participants) was performed to evaluate how many patients could be correctly diagnosed by significant differences in the tested reading parameters. Subsequently, the nuclear cataract and posterior subcapsular cataract patients were compared with cataract patients with coexisting ARMD. RESULTS: Distance visual acuity was comparable in the nuclear cataract, posterior subcapsular cataract, and ARMD groups (P>.05). Reading acuity was significantly reduced in posterior subcapsular cataract and ARMD patients compared with nuclear cataract patients and controls (P<.0001). No significant difference in maximum reading speed was found between the nuclear cataract patients and the controls (P = .07), whereas the maximum reading speed of the posterior subcapsular cataract and ARMD patients was significantly reduced (P<.0001). In the discriminant analysis, it was possible to assign the correct diagnosis to 72% of the nuclear cataract patients, 76% of the posterior subcapsular cataract patients, 72% of the ARMD patients, and 92% of the controls. Comparing the reading performance of nuclear cataract and posterior subcapsular cataract patients and cataract patients with coexisting ARMD showed that reading performance was significantly impaired in the comorbid patients (nuclear cataract and ARMD, P<.001; posterior subcapsular cataract and ARMD, P<.05). CONCLUSION: The high discriminant accuracy shows that this standardized reading test system is a valuable diagnostic tool for evaluating functional visual impairments when distance visual acuity alone cannot elucidate the origin of functional impairment. Considering the significant discrepancies in reading performance among patients with nuclear cataract, posterior subcapsular cataract, and ARMD, reading tests may relevantly improve the clinical evaluation of patients with visual loss, even of patients with ocular comorbidity.


Assuntos
Catarata/diagnóstico , Degeneração Macular/diagnóstico , Leitura , Transtornos da Visão/diagnóstico , Testes Visuais/métodos , Idoso , Catarata/classificação , Catarata/complicações , Análise Discriminante , Feminino , Humanos , Degeneração Macular/complicações , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Transtornos da Visão/etiologia , Testes Visuais/instrumentação , Acuidade Visual/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA