Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 49(2): 619-631, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34387718

RESUMO

PURPOSE: 4-18F-Fluoro-m-hydroxyphenethylguanidine (18F-4F-MHPG) and 3-18F-fluoro-p-hydroxyphenethylguanidine (18F-3F-PHPG) were developed for quantifying regional cardiac sympathetic nerve density using tracer kinetic analysis. The aim of this study was to evaluate their performance in cardiomyopathy patients. METHODS: Eight cardiomyopathy patients were scanned with 18F-4F-MHPG and 18F-3F-PHPG. Also, regional resting perfusion was assessed with 13N-ammonia. 18F-4F-MHPG and 18F-3F-PHPG kinetics were analyzed using the Patlak graphical method to obtain Patlak slopes Kp (mL/min/g) as measures of regional nerve density. Patlak slope polar maps were used to evaluate the pattern and extent of cardiac denervation. For comparison, "retention index" (RI) values (mL blood/min/mL tissue) were also calculated and used to assess denervation. Perfusion polar maps were used to estimate the extent of hypoperfusion. RESULTS: Patlak analysis of 18F-4F-MHPG and 18F-3F-PHPG kinetics was successful in all subjects, demonstrating the robustness of this approach in cardiomyopathy patients. Substantial regional denervation was observed in all subjects, ranging from 25 to 74% of the left ventricle. Denervation zones were equal to or larger than the size of corresponding areas of hypoperfusion. The two tracers provided comparable metrics of regional nerve density and the extent of left ventricular denervation. 18F-4F-MHPG exhibited faster liver clearance than 18F-3F-PHPG, reducing spillover from the liver into the inferior wall. 18F-4F-MHPG was also metabolized more consistently in plasma, which may allow application of population-averaged metabolite corrections. CONCLUSION: The advantages of 18F-4F-MHPG (more rapid liver clearance, more consistent metabolism in plasma) make it the better imaging agent to carry forward into future clinical studies in patients with cardiomyopathy. TRIAL REGISTRATION: Registered at the ClinicalTrials.gov website (NCT02669563). URL: https://clinicaltrials.gov/ct2/show/NCT02669563.


Assuntos
Cardiomiopatias , Tomografia por Emissão de Pósitrons , Cardiomiopatias/diagnóstico por imagem , Coração/diagnóstico por imagem , Coração/inervação , Humanos , Cinética , Tomografia por Emissão de Pósitrons/métodos , Simpatectomia , Sistema Nervoso Simpático/diagnóstico por imagem
2.
J Labelled Comp Radiopharm ; 62(12): 835-842, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31361048

RESUMO

Fluorine-18 labeled hydroxyphenethylguanidines were recently developed in our laboratory as a new class of PET radiopharmaceuticals for quantifying regional cardiac sympathetic nerve density in heart disease patients. Studies of 4-[18 F]fluoro-m-hydroxyphenethylguanidine ([18 F]4F-MHPG) and 3-[18 F]fluoro-p-hydroxyphenethylguanidine ([18 F]3F-PHPG) in human subjects have shown that these radiotracers can be used to generate high-resolution maps of regional sympathetic nerve density using the Patlak graphical method. Previously, these compounds were synthesized using iodonium salt precursors, which provided sufficient radiochemical yields for on-site clinical PET studies. However, we were interested in exploring new methods that could offer significantly higher radiochemical yields. Spirocyclic iodonium ylide precursors have recently been established as an attractive new approach to radiofluorination of electron-rich aromatic compounds, offering several advantages over iodonium salt precursors. The goal of this study was to prepare a spirocyclic iodonium ylide precursor for synthesizing [18 F]4F-MHPG and evaluate its efficacy in production of this radiopharmaceutical. Under optimized automated reaction conditions, the iodonium ylide precursor provided radiochemical yields averaging 7.8% ± 1.4% (n = 8, EOS, not decay corrected), around threefold higher than those achieved previously using an iodonium salt precursor. With further optimization and scale-up, this approach could potentially support commercial distribution of [18 F]4F-MHPG to PET centers without on-site radiochemistry facilities.


Assuntos
Radioisótopos de Flúor/química , Guanidina/química , Guanidina/síntese química , Técnicas de Química Sintética , Halogenação , Marcação por Isótopo , Radioquímica
4.
J Nucl Cardiol ; 23(5): 960-969, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27146882

RESUMO

BACKGROUND: In type I diabetes (T1DM), alterations in LV function may occur due to changes in innervation, metabolism, and efficiency. OBJECTIVES: We evaluated the association between sympathetic nerve function, oxidative metabolism, resting blood flow, LV efficiency and function in healthy diabetics, and assessed gender differences. METHODS: Cross-sectional study of 45 subjects with T1DM, 60% females, age 34 ± 13 years, and 10 age-matched controls. Positron emission tomography (PET) imaging with [(11)C]acetate and [(11)C]meta-hydroxyephedrine was performed, in addition to cardiac magnetic resonance imaging. RESULTS: There were no significant differences in LV function, innervation, or oxidative metabolism between T1DM and controls. Cardiac oxidative metabolism was positively associated with higher levels of sympathetic activation, particularly in women. Diabetic women had significantly lower efficiency compared with diabetic men. Resting flow was significantly higher in diabetic women compared with diabetic men, and tended to be higher in female controls as well. CONCLUSIONS: Measures of myocardial function, metabolism, blood flow, and sympathetic activation were preserved in young, otherwise healthy, T1DM patients. However, T1DM women presented with greater myocardial oxidative metabolism requirements than men. Ongoing studies are evaluating changes over time.


Assuntos
Diabetes Mellitus Tipo 1/fisiopatologia , Cardiomiopatias Diabéticas/fisiopatologia , Efedrina/farmacocinética , Ventrículos do Coração/fisiopatologia , Volume Sistólico , Sistema Nervoso Simpático/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Adulto , Velocidade do Fluxo Sanguíneo , Circulação Coronária , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/diagnóstico por imagem , Cardiomiopatias Diabéticas/diagnóstico por imagem , Cardiomiopatias Diabéticas/etiologia , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Caracteres Sexuais , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia
5.
J Endocr Soc ; 8(6): bvae049, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38617812

RESUMO

Context: Functional positron emission tomography (PET) imaging for the characterization of pheochromocytoma and paraganglioma (PCC/PGL) and for detection of metastases in malignant disease, offers valuable clinical insights that can significantly guide patient treatment. Objective: This work aimed to evaluate a novel PET radiotracer, 3-[18F]fluoro-para-hydroxyphenethylguanidine (3-[18F]pHPG), a norepinephrine analogue, for its ability to localize PCC/PGL. Methods: 3-[18F]pHPG PET/CT whole-body scans were performed on 16 patients (8 male:8 female; mean age 47.6 ± 17.6 years; range, 19-74 years) with pathologically confirmed or clinically diagnosed PCC/PGL. After intravenous administration of 304 to 475 MBq (8.2-12.8 mCi) of 3-[18F]pHPG, whole-body PET scans were performed at 90 minutes in all patients. 3-[18F]pHPG PET was interpreted for abnormal findings consistent with primary tumor or metastasis, and biodistribution in normal organs recorded. Standardized uptake value (SUV) measurements were obtained for target lesions and physiological organ distributions. Results: 3-[18F]pHPG PET showed high radiotracer uptake and trapping in primary tumors, and metastatic tumor lesions that included bone, lymph nodes, and other solid organ sites. Physiological biodistribution was universally present in salivary glands (parotid, submandibular, sublingual), thyroid, heart, liver, adrenals, kidneys, and bladder. Comparison [68Ga]DOTATATE PET/CT was available in 10 patients and in all cases showed concordant distribution. Comparison [123I]meta-iodobenzylguanidine [123I]mIBG planar scintigraphy and SPECT/CT scans were available for 4 patients, with 3-[18F]pHPG showing a greater number of metastatic lesions. Conclusion: We found the kinetic profile of 3-[18F]pHPG PET affords high activity retention within benign and metastatic PCC/PGL. Therefore, 3-[18F]pHPG PET imaging provides a novel modality for functional imaging and staging of malignant paraganglioma with advantages of high lesion affinity, whole-body coregistered computed tomography, and rapid same-day imaging.

6.
Nucl Med Mol Imaging ; 58(2): 86-91, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38510819

RESUMO

Transarterial radioembolization using yttrium-90 (90Y) therapy has become a standard modality of treatment for primary and metastatic liver malignancies due to its high efficacy rate and relatively low risk of adverse effects compared to other forms of locoregional and systemic therapies. Non-target distribution of radio embolic beads and adjacent structure radiation are the two most common adverse effects. However, these are rarely encountered due to thorough imaging and mapping studies prior to 90Y therapy. We present the case of a 66-year-old male who developed a radiation-induced gastric ulcer following 90Y therapy with negative pre-procedural imaging and mapping who was retrospectively found to have an accessory artery from the left hepatic artery to the gastric antrum.

7.
RSC Med Chem ; 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39185448

RESUMO

The most prominent myocardial voltage-gated sodium channel, NaV1.5, is a major drug target for treating cardiovascular disease. However, treatment determination and therapeutic development are complicated partly by an inadequate understanding of how the density of SCN5A, the gene that encodes NaV1.5, relates to treatment response and disease prognosis. To address these challenges, imaging agents derived from NaV1.5 blocking therapeutics have been employed in positron emission tomography (PET) imaging to infer how SCN5A expression relates to human disease in vivo. Herein, we describe the preparation of a novel fluorine-18 labelled analogue of lidocaine, a known NaV1.5 inhibitor, and compare this agent to a previously described analogue. Evidence from rodent and non-human primate PET imaging experiments suggests that the imaging utility of these agents may be limited by rapid metabolism and clearance.

8.
Bioorg Med Chem Lett ; 23(6): 1612-6, 2013 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-23416009

RESUMO

A new cardiac sympathetic nerve imaging agent, [(18)F]4-fluoro-m-hydroxyphenethylguanidine ([(18)F]4F-MHPG), was synthesized and evaluated. The radiosynthetic intermediate [(18)F]4-fluoro-m-tyramine ([(18)F]4F-MTA) was prepared and then sequentially reacted with cyanogen bromide and NH4Br/NH4OH to afford [(18)F]4F-MHPG. Initial bioevaluations of [(18)F]4F-MHPG (biodistribution studies in rats and kinetic studies in the isolated rat heart) were similar to results previously reported for the carbon-11 labeled analog [(11)C]4F-MHPG. The neuronal uptake rate of [(18)F]4F-MHPG into the isolated rat heart was 0.68ml/min/g wet and its retention time in sympathetic neurons was very long (T1/2 >13h). A PET imaging study in a nonhuman primate with [(18)F]4F-MHPG provided high quality images of the heart, with heart-to-blood ratios at 80-90min after injection of 5-to-1. These initial kinetic and imaging studies of [(18)F]4F-MHPG suggest that this radiotracer may allow for more accurate quantification of regional cardiac sympathetic nerve density than is currently possible with existing neuronal imaging agents.


Assuntos
Meios de Contraste/síntese química , Guanidinas/síntese química , Metoxi-Hidroxifenilglicol/química , Fenetilaminas/síntese química , Animais , Meios de Contraste/farmacocinética , Radioisótopos de Flúor/química , Guanidinas/farmacocinética , Meia-Vida , Coração/diagnóstico por imagem , Macaca mulatta , Metoxi-Hidroxifenilglicol/farmacocinética , Miocárdio/metabolismo , Fenetilaminas/farmacocinética , Tomografia por Emissão de Pósitrons , Ratos , Distribuição Tecidual
9.
Nucl Med Biol ; 116-117: 108315, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36680983

RESUMO

The report describes an updated, fully automated method for the production of [11C]butyrate, validated for use in clinical studies. A commercially available GE Tracerlab FXM synthesis module was reconfigured to allow for air-free introduction of n-propyl magnesium chloride and to incorporate Sep-Pak cartridges to simplify and shorten the purification process, as compared to purifying the product using traditional HPLC. The method takes 20 min from end-of-bombardment and reliably produces injectable doses of [11C]butyrate (8029 ± 1628 MBq (217 ± 44 mCi), 14 % radiochemical yield based on [11C]CO2, non-decay corrected) in high radiochemical purity (>97 %), n = 3. With radiotracer in hand, PET scans of rats confirmed uptake of the radiopharmaceutical in the brain. Rat biodistribution data was obtained and used in conjunction with OLINDA software to determine an estimated human total body effective dose of 3.20 × 10-3 mSv/MBq (1.19 × 10-2 rem/mCi), along with preliminary rodent PET imaging that confirmed brain uptake. Lastly, our first human [11C]butyrate PET studies using a dynamic bolus injection technique (n = 5), with a graphical Logan analysis using a white matter reference region, confirmed good radiotracer uptake in the brain and with relatively more prominent uptake in the cerebellar hemispheres, vermis, cingulum cortex and the thalami.


Assuntos
Butiratos , Radiometria , Humanos , Ratos , Animais , Radiometria/métodos , Distribuição Tecidual , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos
10.
Radiology ; 265(1): 240-7, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22843766

RESUMO

PURPOSE: To determine whether cardiac sympathetic denervation in idiopathic Parkinson disease (IPD) affects the left ventricle in a distinct regional pattern versus a more global pattern with use of carbon 11 (11C) meta-hydroxyephedrine (HED) positron emission tomography (PET). MATERIALS AND METHODS: This prospective study was approved by the institutional review board and was compliant with HIPAA. Informed consent was obtained from all subjects. Cardiac PET was performed with 11C HED in 27 patients with IPD (20 men and seven women aged 50-74 years; mean age, 62 years±6 [standard deviation]). 11C HED retention indexes (RIs), which reflect nerve density and integrity, were determined. RIs for 33 healthy control subjects (15 men and 18 women aged 20-78 years; mean age, 47 years±17) were used as a control database. Patients with IPD were compared with control subjects by using z score analysis. Global and segmental measurements of sympathetic denervation were expressed as percentage extent, z score severity, and severity-extent product (SEP). Group comparisons were performed with the Student t test. RESULTS: The mean 11C HED RI was 0.086 mL of blood per minute per milliliter tissue±0.015 for control subjects and 0.043 mL of blood per minute per milliliter tissue±0.016 for patients with IPD (P<0001). When compared with normative data from the control database, profound cardiac denervation (global extent>50%) was seen in most patients (19 of 27 patients, 70%). Four patients had normal 11C HED studies and four had mild denervation (global extent<25%). The mean global denervation extent was 62%±38, the mean severity z score was -2.7±1.2, and the mean SEP was -202±131 (range, -358 to 0). Segmental analysis revealed relative sparing of anterior and proximal septal segments (mean extent, 48%-51%; mean severity z score, -2.47 to -2.0; mean SEP, -167 to -139), with lateral and proximal inferior segments more severely affected (mean extent, 68%-73%; mean severity z score, -2.8 to -2.62; mean SEP, -271 to -230). Patients with normal findings or preserved denervation did not significantly differ in mean age (t=1.09) or disease duration (t=0.44) compared to patients with severe sympathetic denervation. CONCLUSION: Cardiac sympathetic denervation in IPD is extensive, with a segmental pattern that involves the proximal lateral left ventricular wall most severely, with relative sparing of the anterior and proximal septal walls.


Assuntos
Efedrina/análogos & derivados , Sistema de Condução Cardíaco/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/inervação , Coração/diagnóstico por imagem , Coração/inervação , Doença de Parkinson/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Sistema Nervoso Simpático/diagnóstico por imagem , Idoso , Radioisótopos de Carbono , Estudos de Casos e Controles , Meios de Contraste , Feminino , Sistema de Condução Cardíaco/patologia , Ventrículos do Coração/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/patologia , Estudos Prospectivos , Sistema Nervoso Simpático/patologia
11.
ACS Med Chem Lett ; 11(11): 2325-2330, 2020 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-33214848

RESUMO

Radiolabeled guanidines such as meta-iodobenzylguanidine (MIBG) find utility in nuclear medicine as both diagnostic imaging agents and radiotherapeutics and, over the years, numerous methods for incorporating radionuclides into guanidines have been developed. In connection with a project developing new positron emission tomography (PET) radiotracers for cardiac sympathetic nerve density, we had cause to prepare [11C]3F-PHPOG. However, it quickly became apparent that radiolabeling of guanidine scaffolds with carbon-11 has remained challenging, and historical methods lack compatibility with modern automated radiochemistry synthesis platforms and current Good Manufacturing Practice (cGMP) requirements. To address this challenge, we report a new automated method for radiolabeling guanidines with carbon-11. The method was used to prepare a series of [11C]guanidines in good radiochemical yield (8-76% by radio-HPLC) and was found to have broad substrate scope and tolerance of unprotected OH and NH functional groups. The method was used to synthesize [11C]3F-PHPOG for preclinical imaging, and suitability of the radiotracer for preclinical use was demonstrated through preliminary cardiac PET in New Zealand white rabbits which revealed good cardiac uptake and expected retention in the heart.

12.
ACS Chem Neurosci ; 11(3): 427-435, 2020 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-31898886

RESUMO

Development of positron emission tomography (PET) imaging agents capable of quantifying tau aggregates in neurodegenerative disorders such as Alzheimer's disease (AD) is of enormous importance in the field of dementia research. The aim of the present study was to conduct first-in-man imaging studies with the potential novel tau imaging agent [18F]N-methyl lansoprazole ([18F]NML). Herein we report validation of the synthesis of [18F]NML for clinical use by labeling the trifluoromethyl group via radiofluorination of the corresponding gem-difluoro enol ether precursor. This is the first use of this method for clinical production of PET radiotracers and confirmed that it can be readily implemented at multiple production facilities to provide [18F]NML in good noncorrected radiochemical yield (3.4 ± 1.5 GBq, 4.6% ± 2.6%) and molar activity (120.1 ± 186.3 GBq/µmol), excellent radiochemical purity (>97%), and suitable for human use (n = 15). With [18F]NML in hand, we conducted rodent biodistribution, estimates of human dosimetry, and preliminary evaluation of [18F]NML in human subjects at two imaging sites. Healthy controls (n = 4) and mildly cognitively impaired (MCI) AD patients (n = 6) received [18F]NML (tau), [18F]AV1451 (tau), and [18F]florbetaben or [18F]florbetapir (amyloid) PET scans. A single progressive supranuclear palsy (PSP) patient also received [18F]NML and [18F]AV1451 PET scans. [18F]NML showed good brain uptake, reasonable pharmacokinetics, and appropriate imaging characteristics in healthy controls. The mean ± SD of the administered mass of [18F/19F]NML was 2.01 ± 2.17 µg (range, 0.16-8.27 µg) and the mean administered activity was 350 ± 62 MBq (range, 199-403 MBq). There were no adverse or clinically detectable pharmacologic effects in any of the 11 subjects, and no significant changes in vital signs were observed. However, despite high affinity for tau in vitro, brain retention in MCI/AD and PSP patients was low, and there was no evidence of specific signals in vivo that corresponded to tau. Although it is still unclear why clinical translation of the radiotracer was unsuccessful, we nevertheless conclude that further development of [18F]NML as a tau PET imaging agent is not warranted at this time.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Compostos de Anilina/farmacologia , Disfunção Cognitiva/diagnóstico por imagem , Etilenoglicóis/farmacologia , Lansoprazol/farmacologia , Distribuição Tecidual/efeitos dos fármacos , Idoso , Idoso de 80 Anos ou mais , Encéfalo/efeitos dos fármacos , Encéfalo/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons/métodos
13.
EJNMMI Radiopharm Chem ; 5(1): 24, 2020 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-33175263

RESUMO

BACKGROUND: In the US, EU and elsewhere, basic clinical research studies with positron emission tomography (PET) radiotracers that are generally recognized as safe and effective (GRASE) can often be conducted under institutional approval. For example, in the United States, such research is conducted under the oversight of a Radioactive Drug Research Committee (RDRC) as long as certain requirements are met. Firstly, the research must be for basic science and cannot be intended for immediate therapeutic or diagnostic purposes, or to determine the safety and effectiveness of the PET radiotracer. Secondly, the PET radiotracer must be generally recognized as safe and effective. Specifically, the mass dose to be administered must not cause any clinically detectable pharmacological effect in humans, and the radiation dose to be administered must be the smallest dose practical to perform the study and not exceed regulatory dose limits within a 1-year period. In our experience, the main barrier to using a PET radiotracer under RDRC approval is accessing the required information about mass and radioactive dosing. RESULTS: The University of Michigan (UM) has a long history of using PET radiotracers in clinical research studies. Herein we provide dosing information for 55 radiotracers that will enable other PET Centers to use them under the approval of their own RDRC committees. CONCLUSIONS: The data provided herein will streamline future RDRC approval, and facilitate further basic science investigation of 55 PET radiotracers that target functionally relevant biomarkers in high impact disease states.

14.
Circ Cardiovasc Imaging ; 11(12): e007965, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30558502

RESUMO

BACKGROUND: Disease-induced damage to cardiac autonomic nerve populations is associated with an increased risk of sudden cardiac death. The extent of cardiac sympathetic denervation, assessed using planar scintigraphy or positron emission tomography, has been shown to predict the risk of arrhythmic events in heart failure patients staged for implantable cardioverter defibrillator therapy. The goal of this study was to perform first-in-human evaluations of 4-[18F]fluoro-meta-hydroxyphenethylguanidine and 3-[18F]fluoro-para-hydroxyphenethylguanidine, 2 new positron emission tomography radiotracers developed for quantifying regional cardiac sympathetic nerve density. METHODS AND RESULTS: Cardiac positron emission tomography studies with 4-[18F]fluoro-meta-hydroxyphenethylguanidine and 3-[18F]fluoro-para-hydroxyphenethylguanidine were performed in normal subjects (n=4 each) to assess their imaging properties and organ kinetics. Patlak graphical analysis of their myocardial kinetics was evaluated as a technique for generating nerve density metrics. Whole-body biodistribution studies (n=4 each) were acquired and used to calculate human radiation dosimetry estimates. Patlak analysis proved to be an effective approach for quantifying regional nerve density. Using 960 left ventricular volumes of interest, across-subject Patlak slopes averaged 0.107±0.010 mL/min per gram for 4-[18F]fluoro-meta-hydroxyphenethylguanidine and 0.116±0.010 mL/min per gram for 3-[18F]fluoro-para-hydroxyphenethylguanidine. Tracer uptake was highest in heart, liver, kidneys, and salivary glands. Urinary excretion was the main elimination pathway. CONCLUSIONS: 4-[18F]fluoro-meta-hydroxyphenethylguanidine and 3-[18F]fluoro-para-hydroxyphenethylguanidine each produce high-quality positron emission tomography images of the distribution of sympathetic nerves in human heart. Patlak analysis provides reproducible measurements of regional cardiac sympathetic nerve density at high spatial resolution. Further studies of these tracers in heart failure patients will be performed to identify the best agent for clinical development. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02385877.


Assuntos
Guanidinas/farmacocinética , Sistema de Condução Cardíaco/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico , Fenetilaminas/farmacocinética , Tomografia por Emissão de Pósitrons/métodos , Sistema Nervoso Simpático/diagnóstico por imagem , Adulto , Feminino , Radioisótopos de Flúor , Sistema de Condução Cardíaco/metabolismo , Insuficiência Cardíaca/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Sistema Nervoso Simpático/metabolismo , Distribuição Tecidual , Adulto Jovem
15.
J Med Chem ; 50(9): 2078-88, 2007 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-17419605

RESUMO

The norepinephrine transporter (NET) substrates [123I]-m-iodobenzylguanidine (MIBG) and [11C]-m-hydroxyephedrine (HED) are used as markers of cardiac sympathetic neurons and adrenergic tumors (pheochromocytoma, neuroblastoma). However, their rapid NET transport rates limit their ability to provide accurate measurements of cardiac nerve density. [11C]Phenethylguanidine ([11C]1a) and 12 analogues ([11C]1b-m) were synthesized and evaluated as radiotracers with improved kinetics for quantifying cardiac nerve density. In isolated rat hearts, neuronal uptake rates of [11C]1a-m ranged from 0.24 to 1.96 mL min-1 (g wet wt)-1, and six compounds had extremely long neuronal retention times (clearance T1/2 > 20 h) due to efficient vesicular storage. Positron emission tomography (PET) studies in nonhuman primates with [11C]1e, N-[11C]guanyl-m-octopamine, which has a slow NET transport rate, showed improved myocardial kinetics compared to HED. Compound [11C]1c, [11C]-p-hydroxyphenethylguanidine, which has a rapid NET transport rate, avidly accumulated into rat pheochromocytoma xenograft tumors in mice. These encouraging findings demonstrate that radiolabeled phenethylguanidines deserve further investigation as radiotracers of cardiac sympathetic innervation and adrenergic tumors.


Assuntos
Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Guanidinas/síntese química , Guanina/análogos & derivados , Coração/inervação , Neurônios/metabolismo , Octopamina/análogos & derivados , Compostos Radiofarmacêuticos/síntese química , Sistema Nervoso Simpático/metabolismo , Animais , Radioisótopos de Carbono , Guanidinas/química , Guanidinas/farmacocinética , Guanidinas/farmacologia , Guanina/síntese química , Guanina/química , Guanina/farmacocinética , Coração/diagnóstico por imagem , Técnicas In Vitro , Macaca mulatta , Masculino , Camundongos , Camundongos Nus , Proteínas da Membrana Plasmática de Transporte de Norepinefrina/metabolismo , Octopamina/síntese química , Octopamina/química , Octopamina/farmacocinética , Feocromocitoma , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/química , Compostos Radiofarmacêuticos/farmacologia , Ratos , Relação Estrutura-Atividade , Sistema Nervoso Simpático/citologia , Distribuição Tecidual , Ensaios Antitumorais Modelo de Xenoenxerto
16.
J Nucl Med ; 58(2): 326-331, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27539837

RESUMO

The objective of this study was to detect regional patterns of cardiac sympathetic denervation in idiopathic Parkinson disease (IPD) using 11C-hydroxyephedrine (11C-HED) PET and determine the denervation rate over 2 y. METHODS: We obtained 62 cardiac 11C-HED PET scans in 39 patients (30 men and 9 women; mean age ± SD, 61.9 ± 5.9 y), including 23 patients with follow-up scans at 2 y. We derived 11C-HED retention indices (RIs; mL of blood/min/mL of tissue) reflecting nerve density and integrity for 480 left ventricular (LV) sectors. We compared IPD patients with 33 healthy controls using z score analysis; RI values ≤ 2.5 SDs were considered abnormal. We expressed global and regional LV denervation as the percentage extent of z score severity and severity-extent product (SEP) on 9-segment bullseye maps and decline in cardiac sympathetic innervation as the 2-y difference in SEP (diff-SEP). RESULTS: Baseline 11C-HED PET in the 39 IPD patients revealed an RI mean of 0.052 ± 0.022 mL of blood/min/mL of tissue. In comparison with data from normal controls, 12 patients had normal 11C-HED PET, 5 showed mild denervation (percentage extent < 30%), and 22 had moderate to severe denervation (percentage extent > 30%, z score ≤ 2.5 SD). In the 23 paired PET scans, worsening cardiac denervation (global diff-SEP > 9) occurred in 14 of 23 (60.9%) patients over 2 y, including percentage LV abnormality (59% increasing to 66%), z-severity (-2.4 down to -2.5), and SEP (-195 to -227) (P = 0.0062). We found a mean annual decline of 4.6% ± 5.6 (maximum, 13%) in 11C-HED retention from a baseline global RI mean of 0.0481 ± 0.0218 to 0.0432 ± 0.0220 (P = 0.0009). At baseline, 5 patients with normal uptake had no interval change; 3 with mild denervation developed interval decline in lateral and inferior segments (diff-SEP -82 to -99) compared with anterior and septal segments (-65 to -79), whereas the reverse pattern occurred in 15 patients with severe baseline denervation. CONCLUSION: Progressive decline in cardiac sympathetic neural integrity in IPD patients occurs at a modest rate over 2 y on 11C-HED scans with marked heterogeneity and a regional pattern of involvement and decline.


Assuntos
Doenças do Sistema Nervoso Autônomo/diagnóstico por imagem , Efedrina/análogos & derivados , Coração/diagnóstico por imagem , Coração/inervação , Doença de Parkinson/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Idoso , Doenças do Sistema Nervoso Autônomo/etiologia , Progressão da Doença , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/complicações , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Auton Neurosci ; 205: 87-92, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28325598

RESUMO

BACKGROUND: This study evaluated whether measuring the electrochemical skin conductance (ESC), as an indirect measure of sudomotor function, may be also a reliable surrogate for early cardiovascular autonomic neuropathy (CAN). METHODS: Longitudinal study included 37 type 1 diabetes (T1D) subjects (mean age 38±13years, duration 15±7years, HbA1c 7.9±1.1%, no known complications at baseline), and 40 age-matched healthy control (HC) subjects. Mean hands ESC (ESChands) and feet (ESCfeet) were measured with the SUDOSCAN (Impeto Medical, France). CAN was assessed with heart rate variability (HRV) studies (ANSAR Inc., PA), cardiovascular autonomic reflex tests (deep-breathing, Valsalva, postural test), and positron emission tomography with sympathetic analogue [11C]meta-hydroxyephedrine. Associations between measures of CAN and ESC were estimated using Spearman correlations. Longitudinal changes were analyzed using paired t-test. RESULTS: At baseline, there were no differences between T1D and HC in ESChands (69±14 vs. 69±13µS; P=0.84) or ESCfeet (82±8 vs. 78±9µS; P=0.12), while some indices of HRV and Valsalva ratio were significantly lower in T1D vs. HC. T1D subjects experienced a significant decline in both ESChands and ESCfeet at 12months (mean change -7.2±11.6µS, P=0.0006; -2.8±7.3µS, P=0.023 respectively). No significant correlations were consistently found between ESC and measures of CAN at baseline or at 12months. CONCLUSION: Comparing patients with T1D to controls, no differences in ESC were observed at baseline. The associations between ESC and established measures of CAN were inconsistent, which does not support ESC as a reliable surrogate for CAN. While both hands and feet ESC declined over time, the significance of this finding is unclear and warrants further reliability testing.


Assuntos
Sistema Nervoso Autônomo/fisiopatologia , Diabetes Mellitus Tipo 1/fisiopatologia , Neuropatias Diabéticas/fisiopatologia , Neuropatia de Pequenas Fibras/fisiopatologia , Adulto , Feminino , Pé/fisiopatologia , Mãos/fisiopatologia , Frequência Cardíaca , Humanos , Estudos Longitudinais , Masculino , Projetos Piloto , Manobra de Valsalva
18.
ACS Chem Neurosci ; 8(7): 1530-1542, 2017 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-28322043

RESUMO

Fluorine-18 labeled phenethylguanidines are currently under development in our laboratory as radiotracers for quantifying regional cardiac sympathetic nerve density using PET imaging techniques. In this study, we report an efficient synthesis of 18F-hydroxyphenethylguanidines consisting of nucleophilic aromatic [18F]fluorination of a protected diaryliodonium salt precursor followed by a single deprotection step to afford the desired radiolabeled compound. This approach has been shown to reliably produce 4-[18F]fluoro-m-hydroxyphenethylguanidine ([18F]4F-MHPG, [18F]1) and its structural isomer 3-[18F]fluoro-p-hydroxyphenethylguanidine ([18F]3F-PHPG, [18F]2) with good radiochemical yields. Preclinical evaluations of [18F]2 in nonhuman primates were performed to compare its imaging properties, metabolism, and myocardial kinetics with those obtained previously with [18F]1. The results of these studies have demonstrated that [18F]2 exhibits imaging properties comparable to those of [18F]1. Myocardial tracer kinetic analysis of each tracer provides quantitative metrics of cardiac sympathetic nerve density. Based on these findings, first-in-human PET studies with [18F]1 and [18F]2 are currently in progress to assess their ability to accurately measure regional cardiac sympathetic denervation in patients with heart disease, with the ultimate goal of selecting a lead compound for further clinical development.


Assuntos
Guanidinas , Coração/inervação , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Sistema Nervoso Simpático/diagnóstico por imagem , Animais , Avaliação Pré-Clínica de Medicamentos , Guanidinas/sangue , Guanidinas/síntese química , Guanidinas/química , Coração/diagnóstico por imagem , Técnicas In Vitro , Isomerismo , Cinética , Macaca mulatta , Masculino , Estrutura Molecular , Compostos Radiofarmacêuticos/sangue , Compostos Radiofarmacêuticos/síntese química , Compostos Radiofarmacêuticos/química , Ratos Sprague-Dawley
19.
J Nucl Med ; 58(8): 1216-1223, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28302759

RESUMO

Sarcosine is a known substrate of proton-coupled amino acid transporters (PATs), which are overexpressed in selected tissues and solid tumors. Sarcosine, an N-methyl derivative of the amino acid glycine and a metabolic product of choline, plays an important role for prostate cancer aggressiveness and progression. Methods:11C-radiolabeled sarcosine was tested as a new PET imaging probe in comparison with 11C-choline in 2 prostate cancer tumor xenograft models (DU-145 and PC-3). We characterized 11C-sarcosine transport in PC-3 and LNCaP tumor cells and performed 11C-sarcosine PET with CT in the first human subject with localized Gleason 4 + 3 prostate cancer. Target metabolite analyses of sarcosine and its natural precursors, glycine and choline, were performed from independent human prostate tissues. Results: In vitro assays indicated blockage of 11C-sarcosine uptake into PC-3 and LNCaP tumor cells by excess unlabeled (cold) sarcosine. 5-hydroxy-l-tryptophan, but not 2-aminobicyclo-(2,2,1)-heptane-2-carboxylic acid, competitively inhibited 11C-sarcosine tumor cell uptake, confirming PAT-mediated transport. In vivo tumor-to-background ratios (TBRs) obtained from 11C-sarcosine PET were significantly elevated compared with 11C-choline in DU-145 (TBR: 1.92 ± 0.11 for 11C-sarcosine vs. 1.41 ± 0.13 for 11C-choline [n = 10; P < 0.002]) and PC-3 tumors (TBR: 1.89 ± 0.2 for 11C-sarcosine vs. 1.34 ± 0.16 for 11C-choline [n = 7; P < 0.002]). 11C-sarcosine produced high-contrast images in 1 case of localized clinically significant prostate cancer. Target metabolite analyses revealed significant stepwise increases of sarcosine, glycine, and choline tissue levels from benign prostate tissue to localized prostate cancer and subsequently metastatic disease. 11C-sarcosine showed a favorable radiation dosimetry with an effective dose estimate of 0.0045 mSv/MBq, resulting in 2.68 mSv for a human subject (600-MBq dose). Conclusion:11C-sarcosine is a novel radiotracer for PATs and shows initial utility for prostate cancer imaging, with potential benefit over commonly used 11C-choline.


Assuntos
Sistemas de Transporte de Aminoácidos/metabolismo , Radioisótopos de Carbono , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/metabolismo , Prótons , Sarcosina/metabolismo , Linhagem Celular Tumoral , Humanos , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Radiometria , Sarcosina/farmacocinética , Distribuição Tecidual
20.
J Diabetes Complications ; 31(9): 1437-1443, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28709739

RESUMO

AIMS: To assess the role of oxidative stress in mediating adverse outcomes in metabolic syndrome (MetS) and resultant cardiovascular autonomic neuropathy (CAN), and to evaluate the effects of lifestyle interventions on measures of oxidative stress and CAN in subjects with MetS. METHODS: Pilot study in 25 non-diabetic subjects with MetS (age 49±10years, 76% females) participating in a 24-week lifestyle intervention (supervised aerobic exercise/Mediterranean diet), and 25 age-matched healthy controls. CAN was assessed by cardiovascular reflex tests, heart rate variability (HRV) and PET imaging with sympathetic analog [11C] meta-hydroxyephedrine ([11C]HED). Specific oxidative fingerprints were measured by liquid-chromatography/mass-spectrometry (LC/MS). RESULTS: At baseline, MetS subjects had significantly higher oxidative stress markers [3-nitrotyrosine (234±158 vs. 54±47µmol/mol tyrosine), ortho-tyrosine (59±38 vs. 18±10µmol/molphenylalanine, all P<0.0001], and impaired HRV at rest and during deep breathing (P=0.039 and P=0.021 respectively) compared to controls. Twenty-four-week lifestyle intervention significantly reduced all oxidative stress markers (all P<0.01) but did not change any of the CAN measures. CONCLUSIONS: Subjects with MetS present with signs of CAN and increased oxidative stress in the absence of diabetes. The 24-week lifestyle intervention was effective in ameliorating oxidative stress, but did not improve measures of CAN. Larger clinical trials with longer duration are required to confirm these findings.


Assuntos
Doenças do Sistema Nervoso Autônomo/etiologia , Doenças Cardiovasculares/etiologia , Síndrome Metabólica/complicações , Síndrome Metabólica/terapia , Estresse Oxidativo , Comportamento de Redução do Risco , Programas de Redução de Peso/métodos , Adulto , Sistema Nervoso Autônomo/fisiopatologia , Doenças do Sistema Nervoso Autônomo/epidemiologia , Doenças Cardiovasculares/epidemiologia , Sistema Cardiovascular/fisiopatologia , Estudos Transversais , Dieta Mediterrânea , Exercício Físico/fisiologia , Feminino , Humanos , Estilo de Vida , Masculino , Síndrome Metabólica/epidemiologia , Síndrome Metabólica/fisiopatologia , Pessoa de Meia-Idade , Estresse Oxidativo/fisiologia , Projetos Piloto , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA