Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Clin Transplant ; 35(1): e14146, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33175401

RESUMO

Antihuman leukocyte antigen (HLA) antibodies restrict the access to cardiac allografts. Desensitization therapy is a major challenge in patients with cardiogenic shock waiting for urgent heart transplantation (HT). We retrospectively reviewed six patients (mean age of 37.5 years [16-70]) who underwent plasmapheresis (PP) under extracorporeal membrane oxygenation (ECMO) before transplant between January 2017 and September 2018. The average duration of follow-up was 25 months [20-32]. Mean fluorescence intensity (MFI) of HLA-specific antibodies was reported as follows: score 4 for MFI < 1000, score 6 for 1000 < MFI < 3000 and score 8 for MFI > 3000. The mean duration of ECMO support was 29 days [1-74] and 6.8 [1-29] PP sessions were performed per patient before transplant. The mean number of HLA-specific antibodies before HT was 9.6 for score 6 [4-13] and 5.8 for score 8 [1-12]. Four patients had major complications after transplantation (2 hemorrhagic shocks, 5 infectious events). Mean MFI reduction rate was 94% [79-100] for Class I and 44.2% for Class II [0-83]. Hospital survival was 100%, and early antibody-mediated rejection was diagnosed in one patient at 7 days after HT. Plasmapheresis under ECMO support was associated with favorable early outcomes in highly sensitized candidates for urgent heart transplantation.


Assuntos
Oxigenação por Membrana Extracorpórea , Transplante de Coração , Adulto , Antígenos HLA , Humanos , Estudos Retrospectivos , Choque Cardiogênico/terapia
2.
Eur Radiol ; 25(3): 760-6, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25304820

RESUMO

PURPOSE: We sought to determine the relation between major adverse cardiac events (MACE) and anatomical criteria assessed by coronary computed tomography angiography (CCTA) in patients with an anomalous coronary artery with an interarterial course (ACAIAC). MATERIAL AND METHODS: We selected CCTA studies of patients with an ACAIAC from a database of 4,160 examinations and studied anatomical criteria according to the presence of prior MACE, defined as syncope, unstable angina, myocardial infarction and resuscitated sudden cardiac death. RESULTS: There were 19 patients (18 males) with an ACAIAC during the study period (incidence 0.46 %). Seven patients with prior MACE were younger (26 years vs 59 years, p < 0.001), had a smaller minimal lumen area (3.6 mm(2) vs 9.0 mm(2), p = 0.001), a higher degree of area stenosis (57 % vs 24 %, p = 0.001), a longer interarterial course (14.7 vs 8.6 mm, p = 0.003) and a smaller proximal segment width (1.6 mm vs 2.5 mm, p = 0.02) compared with the 12 patients without prior MACE. All patients with MACE had the following concomitant anatomical characteristics: minimum lumen area ≤4 mm(2), an area stenosis ≥50 % and intra-arterial length >10 mm CONCLUSIONS: Prior MACE is associated with specific anatomical CCTA characteristics among patients with ACAIAC. CCTA may therefore contribute to distinguish patients at risk of adverse events.


Assuntos
Anomalias dos Vasos Coronários/patologia , Idoso , Angina Instável/etiologia , Angina Instável/patologia , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/patologia , Anomalias dos Vasos Coronários/diagnóstico por imagem , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/patologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
3.
Cardiovasc Diagn Ther ; 14(1): 59-71, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38434560

RESUMO

Background: Endomyocardial biopsies (EMB) are recommended for the detection of acute cardiac rejection (ACR) despite limited sensitivity. We report the long-term post-transplant results of Doppler echocardiography as a noninvasive alternative of routine EMB. Methods: Two cohorts of heart transplantation (HT) recipients were chronologically defined as follows: the Dual Monitoring Cohort (DMC) from January 1990 to December 1997 included patients who underwent routine EMB and Doppler echocardiography within 24 hours for ACR surveillance; and the "Echo-First Cohort" (EFC), including patients transplanted from January 1998 to December 2018 with Doppler echocardiography as first-line approach for ACR surveillance. Echocardiographic measurements of interest were collected: early diastolic (E) wave peak velocity; pressure half time (PHT) and isovolumetric relaxation time (IVRT). Post-transplant outcomes were reviewed and the Kaplan-Meier approach was used for survival estimates. Inter-operator variability for ultrasound measurements was investigated. Data were collected from medical records from January 2019 to December 2020. Results: A total of 228 patients were included, 99 patients in the DMC and 129 in the EFC. Overall, 5-, 10- and 15-year survival rates were 65.4%, 55.5% and 44.1% respectively, without any significant difference between the two cohorts (log rank test, P=0.71). Echocardiography variables and EMB findings were associated with a mean area under the receiver operating characteristic curve (AUC-ROC) of 0.73 [95% confidence interval (CI): 0.54-0.91], 0.74 (95% CI: 0.54-0.94) and 0.75 (95% CI: 0.57-0.94) respectively for E wave, PHT and IVRT. IVRT and PHT were significantly decreased, and E wave significantly increased, in case of histologically proven ACR. Inter-operator variability was not significant for E wave and IVRT measurements (P=0.13 and 0.30 respectively). Conclusions: Doppler echocardiography as a first-line method for surveillance of ACR did not impair long-term results after HT. These findings suggest that this non-invasive approach might be a reasonable alternative to systematic EMB, limiting risk and improving the quality of life.

5.
J Thorac Cardiovasc Surg ; 164(5): 1412-1420, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-33419559

RESUMO

OBJECTIVE: Standard surgical repair of acute type A aortic dissection is associated with high mortality rates, especially in high-risk patients. In an attempt to improve survival in frail patients, we evaluated the outcomes after ascending aorta wrapping in a high-risk patient cohort. METHODS: This single-center retrospective cohort study included all consecutive patients treated using ascending aorta wrapping for an acute type A aortic dissection from 2008 to 2019. The primary end points included 30-day mortality, survival during follow-up, and dissection-related mortality. Secondary end points included assessment of aortic remodeling after ascending aorta wrapping. Patients with an aortic anatomy suitable for adjunctive endografting of the ascending aorta were also identified. RESULTS: Thirty-five consecutive patients who underwent ascending aorta wrapping were included. Their median age was 77 years (range, 46-96 years). The 30-day all-cause mortality rate was 9%. Major complications occurred in 7 patients (21%), including early reinterventions in 11 (31%). Median follow-up was 36 months (range, 2.4-106.6; interquartile range, 72). The actuarial survival at 36 months was 82%. The dissection-related mortality was 11.4%. The median aortic growth of the nonwrapped descending thoracic aorta was 3.4 mm. Computed tomography scan analysis depicted that 88% of survivors were theoretical candidates for an additional endovascular procedure to exclude the primary entry tear. CONCLUSIONS: Aortic wrapping is associated with favorable early outcomes and a low rate of aortic events during follow-up. This therapeutic option should be considered for patients considered too fragile for standard surgical repair.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/etiologia , Dissecção Aórtica/cirurgia , Aorta/cirurgia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
6.
Arch Cardiovasc Dis ; 114(11): 715-726, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34620574

RESUMO

BACKGROUND: The number of heart transplantations (HTs) has decreased in France since 2017 (-5%/year) despite a stable rate of patients referred on the waiting list. Ex vivo heart perfusion (EVHP) is an innovative approach for organ preservation, reducing graft ischaemic time and facilitating continuous organ monitoring before transplantation. AIM: To report our preliminary experience of seven donor hearts preserved with EVHP, including the first heart resuscitated after circulatory-determined death in France. METHODS: Seven hearts were procured from donation after brain death (DBD) for HT or donation after circulatory-determined death (DCD) for research purposes (Protocol PFS20-004, Agence de la Biomédecine, La Plaine Saint-Denis, France). All grafts were preserved using the Organ Care System® (TransMedics Inc., Andover, MA, USA) for normothermic EVHP. Perfusion parameters were adjusted to achieve stable or decreasing arterial lactate trend consistent with suitability for organ transplantation. RESULTS: Indications for EVHP were assessment of a marginal graft in four cases, prolonged preservation in two cases (anticipated duration for retrieval of recipient's heart>3hours) and resuscitation after circulatory-determined death in one case. Median duration of EVHP was 270 (interquartile range 216-343) minutes. five were transplanted, with a median ex situ preservation time (ischaemic time+EVHP time) of 334 (interquartile range 326-444) minutes. The two other grafts were discarded for HT. Three recipients had extracorporeal life support after HT, and presented complete cardiac recovery within a week after HT. One patient died at day 11 because of septic shock. The 3-month survival rate was 75% among recipients. Three months after HT, the left ventricular ejection fraction was>60% in all cases. CONCLUSIONS: EVHP enabled safe prolonged preservation and assessment of marginal grafts. This approach provides an opportunity to expand the donor pool by resuscitating grafts from donors with extended criteria, including controlled DCD.


Assuntos
Transplante de Coração , Transplante de Coração/efeitos adversos , Humanos , Perfusão , Volume Sistólico , Doadores de Tecidos , Função Ventricular Esquerda
7.
J Heart Valve Dis ; 16(3): 216-24, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17578038

RESUMO

BACKGROUND AND AIM OF THE STUDY: The study aim was to compare, prospectively, the planimetry of aortic stenosis on 64-slice computed tomography (CT), with the area calculated by Doppler transthoracic echocardiography (TTE) in symptomatic patients evaluated before potential aortic valve replacement. METHODS: Fifty-two consecutive patients (27 males, 25 females; mean age 74 +/- 10 years) admitted to the authors' institution during 2005 were evaluated with 64-slice CT and Doppler TTE. The time interval between the two evaluations was 2 +/- 1 weeks. Planimetry of the anatomic orifice area (AOA) drawn on 64-slice CT was compared to the effective area determined by Doppler TTE by Bland and Altman analysis, and the anatomic area threshold value corresponding to a significant effective aortic stenosis (50.75 cm2) was determined by receiver operating characteristic (ROC) analysis. RESULTS: The aortic orifice area measured by 64-slice CT correlated well with the effective area (r = 0.76; p <0.0001), but was significantly greater, with a systematic overestimation (0.132 cm(2)) and a variability of 0.239 cm(2). There was good agreement between planimetry determined by two independent radiologists (difference = 0.002, variability = 0.115 cm(2)). ROC analysis showed that a threshold value of 0.95 cm(2) as measured by 64-slice CT planimetry identifies significant aortic stenosis with sensitivity, specificity, accuracy, positive and negative predictive values of 82%, 77%, 81%, 91% and 59%, respectively. CONCLUSION: 64-slice CT is a reproducible and reliable non-invasive method to evaluate aortic valve stenosis compared to the reference method of Doppler TTE. Indeed, the CT approach could replace the latter evaluation when measurements used in the continuity equation are inadequate.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia Doppler , Tomografia Computadorizada por Raios X/métodos , Idoso , Valva Aórtica/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade
9.
Ann Thorac Surg ; 104(2): e115-e117, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28734429

RESUMO

We report 4 cases of off-pump ascending aorta wrapping combined with ascending aorta stenting in retrograde Stanford A acute aortic dissection (SAAD). Since 2008, 18 patients have undergone wrapping of the ascending aorta at our institution. Four patients had a persistent circulating false lumen in the ascending aorta after wrapping, with a threat to the aortic root. We chose an endovascular approach with ascending aorta stenting. Follow-up computed tomography showed a reapplication of the intimal flap in the reinforced aorta. Ascending aorta stenting after aortic wrapping for retrograde SAAD is a safe and efficient technique to prevent proximal progression of the dissection.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Stents , Idoso , Dissecção Aórtica/diagnóstico , Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
10.
JACC Cardiovasc Interv ; 9(20): 2113-2120, 2016 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-27765304

RESUMO

OBJECTIVES: The study sought to assess the safety and efficacy of a minimally invasive strategy (MIS) (local anesthesia and conscious sedation) compared to general anesthesia (GA) among the largest published cohort of patients undergoing transcarotid transcatheter aortic valve replacement (TAVR). BACKGROUND: Transcarotid TAVR has been shown to be feasible and safe. There is, however, no information pertaining to the mode anesthesia in these procedures. METHODS: Between 2009 and 2014, 174 patients underwent transcarotid TAVR at 2 French centers. All patients were unsuitable for transfemoral TAVR due to severe peripheral vascular disease. An MIS was undertaken in 29.8% (n = 52) and GA in 70.1% (n = 122). One-year clinical outcomes were available in all patients and were described according to the Valve Academic Research Consortium-2 consensus. RESULTS: Transcarotid vascular access and transcatheter valve deployment was successful in all cases. Thirty-day mortality was 7.4% (n = 13) and 1-year all-cause and cardiovascular mortality were 12.6% (n = 22) and 8.0% (n = 14), respectively. According to the type of anesthesia, there was no between group difference in 30-day mortality (GA 7.3% vs. MIS 7.6%; p = 0.94), 1-year mortality (GA 13.9% vs. MIS 9.6%; p = 0.43), 1-month clinical efficacy (GA 85.2% vs. MIS 94.2%; p = 0.09), and early safety (GA 77.8% vs. MIS 86.5%; p = 0.18). There were 10 (5.7%) periprocedural cerebrovascular events: 4 strokes (2.2%) and 6 transient ischemic attacks (3.4%) among those treated with GA. There was neither stroke nor transient ischemic attack in the MIS group (p < 0.001). CONCLUSIONS: The transcarotid approach for TAVR is feasible using general or local anesthesia. A higher rate of perioperative strokes was observed with GA.


Assuntos
Anestesia Geral , Anestesia Local , Valva Aórtica/cirurgia , Artéria Carótida Primitiva , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Anestesia Geral/efeitos adversos , Anestesia Geral/mortalidade , Anestesia Local/efeitos adversos , Anestesia Local/mortalidade , Bases de Dados Factuais , Feminino , França , Humanos , Ataque Isquêmico Transitório/etiologia , Estimativa de Kaplan-Meier , Masculino , Modelos de Riscos Proporcionais , Punções , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
12.
J Thorac Cardiovasc Surg ; 125(5): 1022-9, 2003 May.
Artigo em Inglês | MEDLINE | ID: mdl-12771874

RESUMO

OBJECTIVE: Esmolol, an ultra-short-acting beta-blocker, is known to attenuate myocardial ischemia-reperfusion injury. The aim of this study was to compare the effects of esmolol and potassium on myocardial metabolism during continuous normothermic retrograde blood cardioplegia. METHODS: Forty-one patients operated on for isolated aortic valve stenosis were randomly assigned to continuous coronary infusion with either potassium or esmolol during cardiopulmonary bypass. Myocardial metabolism was assessed by measuring the transmyocardial gradient of oxygen content indexed to left ventricular mass of glucose, lactate, and nitric oxide. To do so, blood samples were simultaneously withdrawn upstream (in the cardioplegia line) and downstream of the myocardium (in the left coronary ostium) 10 and 30 minutes after aortic crossclamping. RESULTS: Although the cardioplegia flow rate and pressure were similar, esmolol markedly reduced the transmyocardial gradient of oxygen content indexed to left ventricular mass compared with potassium: 13 +/- 6 vs 20 +/- 6 mL of oxygen per liter of blood per 100 g of myocardium, respectively, at 10 minutes and 16 +/- 8 vs 24 +/- 8 mL of oxygen per liter of blood per 100 g of myocardium, respectively, at 30 minutes (P =.009). Coronary glucose and lactate transmyocardial gradients were similar in both groups, indicating adequate myocardial perfusion in all patients at all times. In addition, during retrograde cardioplegia, esmolol showed a lower nitric oxide release compared with that caused by potassium (39 +/- 49 micro mol x L(-1) for potassium vs 14 +/- 8 micro mol x L(-1) for esmolol at 10 minutes and 39 +/- 47 micro mol x L(-1) for potassium vs 6 +/- 8 micro mol x L(-1) for esmolol at 30 minutes, P =.05). However, hemodynamic parameters and plasma troponin I levels remained unchanged postoperatively between the 2 types of cardioplegia. CONCLUSION: Esmolol provides potent myocardial protection in hypertrophied hearts, at least in part, by reducing myocardial oxygen metabolism.


Assuntos
Antagonistas Adrenérgicos beta/uso terapêutico , Estenose da Valva Aórtica/cirurgia , Soluções Cardioplégicas , Isquemia Miocárdica/prevenção & controle , Potássio/uso terapêutico , Propanolaminas/uso terapêutico , Antagonistas Adrenérgicos beta/farmacologia , Idoso , Estenose da Valva Aórtica/complicações , Soluções Cardioplégicas/efeitos adversos , Ponte Cardiopulmonar , Humanos , Hipertrofia Ventricular Esquerda/complicações , Ácido Láctico/sangue , Tempo de Internação , Pessoa de Meia-Idade , Contração Miocárdica/efeitos dos fármacos , Isquemia Miocárdica/etiologia , Consumo de Oxigênio/efeitos dos fármacos , Potássio/farmacologia , Propanolaminas/farmacologia , Resultado do Tratamento , Troponina/sangue
13.
Heart Surg Forum ; 6(6): E146-7, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14722002

RESUMO

The left internal thoracic artery lpa r;LITA) is the preferred graft with the best patency rate in coronary artery bypass grafting (CABG). To maximize its use, we developed a technique of grafting 2 distant coronary arteries with the LITA, using its distal portion segmented to construct a Y graft with either the in situ LITA or right internal thoracic artery (RITA). We applied this technique in 51 patients. The distal segment of the LITA was used to create a Y graft in 4 different configurations according to coronary pathology. Offpump grafting was performed in 11% of cases. The use of a distal segment of the LITA was thus extended not only to the left anterior descending artery and branches but also to the circumflex and right coronary artery territories.


Assuntos
Anastomose de Artéria Torácica Interna-Coronária/métodos , Artéria Torácica Interna/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Artéria Torácica Interna/transplante , Pessoa de Meia-Idade , Coleta de Tecidos e Órgãos/métodos
14.
Ann Thorac Surg ; 97(5): 1590-6, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24518574

RESUMO

BACKGROUND: Conventional surgical treatment of Stanford type A acute aortic dissection (AAD) is associated with considerable in-hospital mortality. As regards very elderly or high-risk patients with type A AAD, some may meet the criteria for less invasive surgery likely to prevent the complications associated with aortic replacement. METHODS: We have retrospectively analyzed a cohort of patients admitted to our center for Stanford type A AAD and having undergone surgery between 2008 and 2012. The outcomes of the patients having had an aortic replacement under cardiopulmonary bypass (group A) have been compared with the outcomes of the patients who underwent off-pump wrapping of the ascending aorta (group B). RESULTS: Among the 54 patients admitted for Stanford type A AAD, 15 with a mean age of 77 years [46 to 94] underwent wrapping of the aorta. Regarding the new standard European system for cardiac operative risk evaluation (EuroSCORE II), the median result in our group B patients was 10.47 [5.02 to 30.07]. In-hospital mortality was 12.80% in group A and 6.6% in group B (p=0.66). For patients who underwent external wrapping of the ascending aorta, follow-up mortality rate was 13.3% with a median follow-up of 15 months [range 0 to 47]. CONCLUSIONS: The gold standard in cases of Stanford type A AAD consists of emergency surgical replacement of the dissected ascending aorta. In some cases in which the aortic root is not affected a less invasive surgical approach consisting of wrapping the dissected ascending aorta can be suggested as an alternative.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Causas de Morte , Mortalidade Hospitalar , Procedimentos Cirúrgicos Vasculares/métodos , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Angiografia/métodos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Ponte Cardiopulmonar/métodos , Estudos de Coortes , Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Ponte de Artéria Coronária sem Circulação Extracorpórea/mortalidade , Emergências , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/mortalidade , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/fisiopatologia , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Estatísticas não Paramétricas , Análise de Sobrevida , Fatores de Tempo , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/mortalidade
15.
J Thorac Cardiovasc Surg ; 148(5): 1903-11, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24685376

RESUMO

OBJECTIVE: Stentless xenograft bioprostheses may be the future valve of choice for aortic valve replacement. The study aim was to investigate the long-term clinical outcome after aortic valve replacement with the Medtronic Freestyle bioprosthesis (Medtronic Inc, Minneapolis, Minn). METHODS: Between April 1997 and November 2004, a total of 500 patients (mean age, 74.5±9.6 years; 52% were male) underwent aortic valve replacement with a Freestyle bioprosthesis, without population selection. The surgical procedure used a modified subcoronary technique in 479 patients and a complete root replacement in 21 patients, conducted with mini-extracorporeal circulation. Concomitant procedures included coronary artery bypass grafting in 122 patients (24%) and mitral valve repair/replacement in 11 patients. RESULTS: The mean cardiopulmonary bypass time was 98±26 minutes, and total aortic crossclamp time was 77±19 minutes. Operative mortality was 5.2%. The median follow-up time was 104.8±5.7 months. During this period, there were 224 deaths (n=122 cardiovascular and n=102 noncardiovascular deaths). The actuarial survivals from cardiovascular and valve-related mortality were 67%±3% and 70%±4%, respectively, at 10 years. Freedom from structural valve deterioration at 10 years was 94%±2%. The linearized structural valve deterioration incidence was 0.6% per patient/year. Multivariate Cox regression analysis revealed that older age, impaired renal function, and coronary artery disease were independent predictors of cardiovascular death. In the subgroup of patients aged less than 65 years at implantation (n=45), the actuarial cardiovascular survival was 83%±8% and freedom from structural valve deterioration was 89%±6% at 10 years. CONCLUSIONS: The use of the Freestyle bioprosthesis for aortic valve replacement resulted in good long-term cardiovascular survival and freedom from structural valve deterioration in this cohort regardless of age at implantation.


Assuntos
Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Ponte Cardiopulmonar , Feminino , França , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Duração da Cirurgia , Complicações Pós-Operatórias/mortalidade , Modelos de Riscos Proporcionais , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
16.
Eur J Cardiothorac Surg ; 46(4): 693-8; discussion 698, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24431170

RESUMO

OBJECTIVES: Trans-femoral and transapical are the most commonly used accesses for transcatheter aortic valve implantation (TAVI). However, when these approaches are unsuitable, alternative accesses are needed. We report a series of 19 patients undergoing TAVI through common carotid artery (CCA) access under local anaesthesia in order to assess its feasibility and safety. METHODS: From November 2008 to September 2013, 361 patients underwent TAVI at our institution. Nineteen of them (14 men) with mean age 82.2 ± 6.2 years, EuroSCORE 25.2 ± 15.7, Society of Thoracic Surgeons score 11.9 ± 5.1 and with severe peripheral arteriopathy were unsuitable for usual approaches and underwent TAVI through CCA access under local anaesthesia. Preoperative computed tomography assessed suitable carotid artery anatomy. Common carotid cross-clamping test allowed verifying patient's neurological status stability. An 18-Fr or 20-Fr sheath inserted into the CCA down into the ascending aorta was used for the delivery catheter. Valve implantation procedures were as usual. After sheath removal, the CCA was surgically purged and repaired. Feasibility and safety end points (VARC-2) were collected up to 30 days. RESULTS: Transcarotid insertion of the delivery sheath was successful in all cases (8 right, 11 left) and accurate deployment of the device was achieved in 18 patients (4 Edwards SAPIEN XT and 14 Medtronic CoreValve). There was 1 intraoperative death by annulus rupture during preimplant balloon valvuloplasty, and 1 in-hospital death due to multisystem organ failure. There was no myocardial infarction, stroke or major bleeding. Third-degree atrioventricular block requiring pacemaker implantation occurred in 3 patients. No vascular access-site, access-related or other TAVI-related complication occurred. Echocardiography revealed good prosthesis functioning with none, mild and moderate paravalvular leak in, respectively, 8, 9 and 1 patients. Patient ambulation was immediate after TAVI and hospital stay was 4.6 ± 2.3 days. CONCLUSIONS: TAVI through the CCA approach under local anaesthesia is feasible and safe. It allows continuous clinical neurological status monitoring with low risk of stroke, bleeding events, vascular access-site and access-related complications and immediate patient ambulation. It appears to be a valuable alternative access for patients who cannot undergo trans-femoral TAVI.


Assuntos
Anestesia Local/métodos , Artéria Carótida Primitiva/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Anestesia Local/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estudos de Coortes , Estudos de Viabilidade , Feminino , Humanos , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos
18.
Int J Cardiol ; 167(3): 687-92, 2013 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-22459396

RESUMO

OBJECTIVE: To assess the relation of aortic transvalvular gradient with outcomes following transcatheter aortic valve implantation (TAVI). BACKGROUND: Relatively little is known about the predictors of adverse outcomes in patients with severe aortic stenosis following TAVI. METHODS: We studied 126 consecutive patients (mean age 83.2 ± 6.3 years; 59% women) who underwent TAVI (23% transapical; 77% transfemoral) at our institution. All patients were followed for the incidence of major adverse cardiovascular events (MACE), including myocardial infarction, heart failure, stroke, and cardiovascular death. RESULTS: The acute procedural success rate was 98%; at 1 year, the cumulative incidence of MACE and cardiovascular death was 29% and 10%, respectively. In multivariable analyses adjusting for clinical and echocardiographic risk factors, presence of a baseline mean transvalvular gradient (MTG) <40 mmHg was a significant predictor of 30-day MACE in the total sample (OR 4.4, 95% CI 1.7-11.4; P=0.003) as well as in patients with an ejection fraction ≥ 50% (OR 10.3, 95% CI 3.0-33.4; P<0.001). In multivariable analyses, low MTG was also associated with 2-fold and 4-fold increased hazards for MACE (HR 4.2, 95% CI 2.0-8.9; P<0.001) and cardiovascular death (HR 4.2 95% CI 1.2-14.9; P=0.03), respectively, within 1 year following TAVI. CONCLUSION: Presence of a low MTG (<40 mmHg) prior to TAVI was associated with a greater risk of major adverse events, including cardiovascular death, up to 1 year following the procedure. Pre-procedural MTG could be used to identify patients at a high risk for adverse outcomes following TAVI.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Complicações Pós-Operatórias/fisiopatologia , Cuidados Pré-Operatórios , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Complicações Pós-Operatórias/diagnóstico , Cuidados Pré-Operatórios/métodos , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
19.
Int J Cardiol ; 168(1): 151-6, 2013 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-23079085

RESUMO

BACKGROUND: TAVI is an alternative solution for patients with aortic valve stenosis (AS) who are refused for conventional surgery. We sought to evaluate the incidence, characteristics, predictors and prognosis impact of serious hemorrhagic complications following transcatheter aortic valve implantation (TAVI). METHODS: One hundred and seventy one consecutive patients with symptomatic severe AS (83.5 ± 6.1 y; 53% women; mean EuroSCORE=22.1 ± 12.3) underwent transapical (TA) or transfemoral (TF) TAVI in our institution using Edwards SAPIEN© and Medtronic CoreValve© devices. The primary evaluated criterion was the incidence of any bleeding complication, according to the Valve Academic Research Consortium (VARC) criteria. RESULTS: VARC serious hemorrhagic complications occurred in 34.5% of patients (n=23 life-threatening/disabling (LT/D) and n=36 major bleedings). Most of these complications were related to access site complications (69%). Multivariable analysis revealed that TA access, low weight and underlying coronary artery diseases were independent predictors for development of serious bleeding. The mortality was significantly higher in patients with serious events compared to patients without bleeding (p=0.008, log-rank analysis). Although the survival didn't significantly differ in patients with major hemorrhagic events, subjects with LT/D bleeding events had a higher mortality than the subjects with no hemorrhagic complications (p<0.001, log-rank analysis). Occurrence of VARC LT/D event independently predicted all-cause mortality (HR=5.35 [2.51-11.43], p<0.001) during the first year following TAVI in multivariate Cox regression analysis. CONCLUSION: Severe bleeding is frequent following TAVI procedure and is mainly related to local hemorrhage. VARC LT/D events are associated with decreased survival after AS correction.


Assuntos
Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemorragia Pós-Operatória/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estudos de Coortes , Feminino , Seguimentos , Humanos , Incidência , Masculino , Hemorragia Pós-Operatória/diagnóstico , Valor Preditivo dos Testes , Prognóstico , Resultado do Tratamento
20.
Ann Thorac Surg ; 92(3): e49-50, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21871254

RESUMO

We describe off-pump wrapping of the ascending aorta in 3 high-risk patients with acute type A aortic dissection when the primary intimal tear was not located in the ascending aorta and in the absence of aortic insufficiency. A Teflon plaque (Bard Inc, Murray Hill, NJ) was tailored to tightly wrap the aorta from the coronary ostia to the innominate artery. The mean age of the patients was 80.3 years. All patients were at high risk for conventional surgery. A postoperative computed tomographic scan showed a reapplication of the intimal flap and containment of the false lumen in the reinforced ascending aorta in all patients.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Politetrafluoretileno , Telas Cirúrgicas , Procedimentos Cirúrgicos Vasculares/instrumentação , Doença Aguda , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/diagnóstico , Aneurisma da Aorta Torácica/diagnóstico , Feminino , Seguimentos , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Tomografia por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA