Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Biomed Eng Online ; 12: 64, 2013 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-23827015

RESUMO

BACKGROUND: ECG (Electrocardiogram) measurements in home health care demands new sensor solutions. In this study, six different configurations of screen printed conductive ink electrodes have been evaluated with respect to electrode potential variations and electrode impedance. METHODS: The electrode surfaces consisted of a Ag/AgCl-based ink with a conduction line of carbon or Ag-based ink underneath. On top, a lacquer layer was used to define the electrode area and to cover the conduction lines. Measurements were performed under well-defined electro-chemical conditions in a physiologic saline solution. RESULTS: The results showed that all printed electrodes were stable and have a very small potential drift (less than 3 mV/30 min). The contribution to the total impedance was 2% of the set maximal allowed impedance (maximally 1 kΩ at 50 Hz), assuming common values of input impedance and common mode rejection ratio of a regular amplifier. CONCLUSION: Our conclusions are that the tested electrodes show satisfying properties to be used as elements in a skin electrode design that could be suitable for further investigations by applying the electrodes on the skin.


Assuntos
Eletrocardiografia/instrumentação , Impressão , Impedância Elétrica , Eletrodos , Humanos , Prata , Compostos de Prata , Pele , Propriedades de Superfície
2.
Med Biol Eng Comput ; 45(12): 1251-7, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17929069

RESUMO

Clothing with conductive textiles for health care applications has in the last decade been of an upcoming research interest. An advantage with the technique is its suitability in distributed and home health care. The present study investigates the electrical properties of conductive yarns and textile electrodes in contact with human skin, thus representing a real ECG-registration situation. The yarn measurements showed a pure resistive characteristic proportional to the length. The electrodes made of pure stainless steel (electrode A) and 20% stainless steel/80% polyester (electrode B) showed acceptable stability of electrode potentials, the stability of A was better than that of B. The electrode made of silver plated copper (electrode C) was less stable. The electrode impedance was lower for electrodes A and B than that for electrode C. From an electrical properties point of view we recommend to use electrodes of type A to be used in intelligent textile medical applications.


Assuntos
Microeletrodos , Telemetria/instrumentação , Têxteis , Engenharia Biomédica , Vestuário , Cobre , Condutividade Elétrica , Impedância Elétrica , Humanos , Poliésteres , Prata , Aço Inoxidável
3.
Artigo em Inglês | MEDLINE | ID: mdl-18003315

RESUMO

In this study we aim to explain the behavior of textile electrodes due to their construction techniques. Three textile electrodes were tested for electrode impedance and polarization potentials. The multifilament yarn (A) is favorable for its low thread resistance. Although, when knitted into electrodes, the staple fiber yarn (B) showed a comparable and satisfiable electrode impedance. The multifilament yarn had however a lower polarization potential drift then the other specimens. The monofilament yarn (C) had high electrode impedance and varying mean polarization potentials due to its conductive material and small contact area with the skin.


Assuntos
Vestuário , Eletrodos , Monitorização Ambulatorial/instrumentação , Têxteis , Condutividade Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Materiais , Monitorização Ambulatorial/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA