Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Electrophoresis ; 33(9-10): 1449-57, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22648814

RESUMO

In this work, the use of the ionic liquid (IL) 1,3-dipentylimidazolium hexafluorophosphate ([PPIm][PF6]) as an alternative extractant for IL dispersive liquid-liquid microextraction (IL-DLLME) of a group of pesticides and metabolites (2-aminobenzimidazole, carbendazim/benomyl, thiabendazole, fuberidazole, carbaryl, 1-naphthol, and triazophos) from soils is described. After performing an initial ultrasound-assisted extraction (USE), the IL-DLLME procedure was applied for the extraction of these organic analytes from soil extracts. Separation and quantification was achieved by high-performance liquid chromatography (HPLC) with fluorescence detection (FD). Calibration, precision, and accuracy of the described USE-IL-DLLME-HPLC-FD method using [PPIm][PF6] as an alternative extractant was evaluated with two soils of different physicochemical properties. Accuracy percentages were in the range 93-118% with RSD values below 20%. A comparison of the performance of [PPIm][PF6] versus that of the so-common 1-hexyl-3-methylimidazolium hexafluorophosphate ([HMIm][PF6]) was accomplished. Results indicate a comparable extraction efficiency with both ILs, being slightly higher with [HMIm][PF6] for the metabolite 2-aminobenzimidazole, and slightly higher with [PPIm][PF6] for triazophos. In all cases, LODs were in the low ng/g range (0.02-14.2 ng/g for [HMIm][PF6] and 0.02-60.5 ng/g for [PPIm][PF6]). As a result, the current work constitutes a starting point for the use of the IL [PPIm][PF6] for further analytical approaches.


Assuntos
Imidazóis/química , Líquidos Iônicos/química , Microextração em Fase Líquida/métodos , Resíduos de Praguicidas/isolamento & purificação , Poluentes do Solo/isolamento & purificação , Benzimidazóis/análise , Benzimidazóis/isolamento & purificação , Carbamatos/análise , Carbamatos/isolamento & purificação , Cromatografia Líquida de Alta Pressão , Naftóis/análise , Naftóis/isolamento & purificação , Organotiofosfatos/análise , Organotiofosfatos/isolamento & purificação , Resíduos de Praguicidas/análise , Reprodutibilidade dos Testes , Poluentes do Solo/análise , Espectrometria de Fluorescência , Triazóis/análise , Triazóis/isolamento & purificação
2.
Electrophoresis ; 30(10): 1624-46, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19360778

RESUMO

The first on-line coupling of CE with MS detection more than 20 years ago provided a very powerful technique with a wide variety of applications, among which food analysis is of special interest, especially that dealing with food safety and food quality applications, the major topics of public interest nowadays. With this review article, we would like to show the most recent applications of CE-MS in both fields by recompiling and commenting articles published between January 2004 and October 2008. Although both applications are difficult to separate from each other, we have included in this work two main sections dealing with each specific field. Future trends will also be discussed.


Assuntos
Eletroforese Capilar , Análise de Alimentos/métodos , Contaminação de Alimentos/análise , Espectrometria de Massas , Manipulação de Alimentos/métodos
3.
Anal Bioanal Chem ; 395(7): 2387-95, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19779926

RESUMO

Room temperature ionic liquids (RTILs) have been used as extraction solvents in dispersive liquid-liquid microextraction (DLLME) for the determination of eight multi-class pesticides (i.e. thiophanate-methyl, carbofuran, carbaryl, tebuconazole, iprodione, oxyfluorfen, hexythiazox, and fenazaquin) in table grapes and plums. The developed method involves the combination of DLLME and high-performance liquid chromatography with diode array detection. Samples were first homogenized and extracted with acetonitrile. After evaporation and reconstitution of the extract in water containing sodium chloride, a quick DLLME procedure that used the ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate ([C(6)MIM][PF(6)]) and methanol was developed. The RTIL dissolved in a very small volume of acetonitrile was directed injected in the chromatographic system. The comparison between the calibration curves obtained from standards and from spiked sample extracts (matrix-matched calibration) showed the existence of a strong matrix effect for most of the analyzed pesticides. A recovery study was also developed with five consecutive extractions of the two types of fruits spiked at three concentration levels. Mean recovery values were in the range of 72-100% for table grapes and 66-105% for plum samples (except for thiophanate-methyl and carbofuran, which were 64-75% and 58-66%, respectively). Limits of detection (LODs) were in the range 0.651-5.44 microg/kg for table grapes and 0.902-6.33 microg/kg for plums, representing LODs below the maximum residue limits (MRLs) established by the European Union in these fruits. The potential of the method was demonstrated by analyzing 12 commercial fruit samples (six of each type).


Assuntos
Fracionamento Químico/métodos , Líquidos Iônicos/química , Praguicidas/química , Prunus/química , Vitis/química , Cromatografia Líquida de Alta Pressão , Análise de Alimentos , Contaminação de Alimentos , Estrutura Molecular , Temperatura
4.
J Chromatogr A ; 1211(1-2): 33-42, 2008 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-18849040

RESUMO

Multi-walled carbon nanotubes (MWCNTs) have been used for the first time as solid-phase extraction (SPE) sorbents for the extraction of eight organophosphorus pesticides (i.e. ethoprophos, diazinon, chlorpyriphos-methyl, fenitrothion, malathion, chlorpyriphos, fenamiphos and buprofezin) from different commercial fruit juices (i.e. apple, grape, orange and pineapple). The developed method, which involves SPE and direct gas chromatography with nitrogen phosphorus detection analysis, is very fast, simple and cheap: only 1:1 dilution with Milli-Q water and pH adjustment to 6.0 of 10 mL of juice is necessary prior to a quick MWCNTs-SPE procedure that used only 40 mg of stationary phase (MWCNTs of 10-15 nm o.d., 2-6 nm i.d. and 0.1-10 microm length). Mean recovery values were above 73% for all the pesticides and fruit juices (between 77 and 101% for apple juice, 75 and 103% for grape juice, 73 and 103% for orange juice and 73 and 93% for pineapple juice) with a relative standard deviation (RSD) lower than 8.5% in all cases. Matrix matched calibration was carried out for each sample matrix since statistical differences between the calibration curves constructed is pure solvent and in the reconstructed juice extracts were found. Limits of detection ranged between 1.85 and 7.32 microg/L (which also represents LODs between 1.85 and 7.34 microg/kg) well below the European Union maximum residue limits for the raw fruits. The proposed method, which is demonstrated to be quick, cheap, accurate and highly selective, was also applied to the analysis of this group of pesticides in several commercial juices in which none of the selected pesticides were found.


Assuntos
Bebidas/análise , Frutas/química , Nanotubos de Carbono , Compostos Organofosforados/análise , Praguicidas/análise , Extração em Fase Sólida/métodos , Calibragem , Cromatografia Gasosa/economia , Cromatografia Gasosa/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Extração em Fase Sólida/economia
5.
J Chromatogr A ; 1185(1): 151-4, 2008 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-18280487

RESUMO

The analysis of a group of seven pesticides (i.e. six fungicides: pyrimethanil, procymidone, nuarimol, fenarimol, benalaxyl and penconazole and one insecticide: pirimicarb) in tomato samples by micellar electrokinetic chromatography is investigated. For this purpose, reversed electrode polarity stacking mode and solid-phase microextraction (SPME) have been used as on-line and off-line preconcentration procedures, respectively. Tomato samples were first homogenized and extracted with acetone. After suitable evaporation and reconstitution of the extract in water, a SPME procedure using poly(dimethylsiloxane)/divinylbenzene fibers was used. Due to the strong influence of the sample matrix in the extraction, a matrix matched calibration of spiked tomato samples was developed. The method was found to be linear between 0.5 and 2.5 mg/kg. Limits of detection achieved are below the maximum residue limits established by the European Union and Spain legislation as well as by the Codex Alimentarius (except for penconazole). The potential of the method was demonstrated by analyzing 12 tomato samples (of ecological and non-ecological production) taken from regional cultivars. No residues of the selected pesticides were detected in any of the samples.


Assuntos
Cromatografia Capilar Eletrocinética Micelar/métodos , Resíduos de Praguicidas/análise , Solanum lycopersicum/química , Microextração em Fase Sólida/métodos , Pirimidinas/análise , Verduras/química
6.
J Sep Sci ; 31(20): 3612-9, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18837477

RESUMO

In the present work, a GC method with nitrogen-phosphorus detection (NPD) was developed for the simultaneous determination of eight organophosphorus pesticide (OPP) residues (i.e., ethoprofos, diazinon, chlorpyrifos-methyl, fenitrothion, malathion, chlorpyrifos, fenamiphos, and buprofezin) in water samples. Preconcentration of the water samples was carried out using an SPE procedure with multiwalled carbon nanotubes (MWCNTs) of 10-15 nm od, 2-6 nm id, and 0.1-10 microm length as stationary phase. Extraction parameters, such as the amount of MWCNTs, sample volume, pH, and type and amount of the eluent were optimized. The most favorable conditions were as follows: 40 mg MWCNTs, 800 mL water, pH 6.0, and 20 mL dichloromethane, respectively. The MWCNTs-SPE-GC-NPD method was applied to the determination of these pesticides in real water samples: mineral and ground water as well as run-off water from an agricultural area collected shortly before opening out onto the sea. A recovery study was developed with five consecutive extractions of the three types of water spiked at three concentration levels (n = 15). Mean recovery values were in the range of 75-116% for mineral water (RSD < 6.3%), 67-119% for ground water (RSD < 5.8%), and 57-81% for run-off waters (RSDs < 6.9%), except for fenamiphos (mean recovery values between 40 and 84% for the three types of waters, RSDs < 8.9%). LODs were in the low ng/L level (i.e., levels below the maximum residue limits (MRLs) established by the European Union (EU) legislation for these compounds in waters). The proposed method was also applied to the analysis of six water samples (two of each type: mineral, ground, and run-off waters) in which no residues of the selected pesticides were found. Results show that the MWCNTs used in this work have a high adsorbability of the pesticides under study. The main advantage of the use of these MWCNTs is their low cost when compared with those MWCNTs previously used in the literature and with conventional SPE cartridges.

7.
J Chromatogr A ; 1165(1-2): 52-7, 2007 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-17681518

RESUMO

In this work an analytical method for the determination of abamectin residues in avocados is developed using high-performance liquid chromatography (HPLC) with fluorescence (FL) detection. A pre-column derivatization with trifluoroacetic anhydride (TFAA) and N-methylimidazole (NMIM) was carried out. The mobile phase consisted of water, methanol and acetonitrile (5:47.5:47.5 v/v/v) and was pumped at a rate of 1 mL/min (isocratic elution). The fluorescence detector was set at an excitation wavelength of 365 nm and an emission wavelength of 470 nm. Homogenized avocado samples were extracted twice with acetonitrile:water 8:2 (v/v) and cleaned using C(18) solid-phase extraction (SPE) cartridges. Recovery values were in the range 87-98% with RSD values lower than 13%. The limits of detection (LODs) and quantification (LOQs) of the whole method were 0.001 and 0.003 mg/kg, respectively. These values are lower than the maximum residue limit (MRL) established by the European Union (EU) and the Spanish legislation in avocado samples.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Ivermectina/análogos & derivados , Persea/química , Resíduos de Praguicidas/isolamento & purificação , Extração em Fase Sólida/métodos , Espectrometria de Fluorescência/métodos , Ivermectina/química , Ivermectina/isolamento & purificação , Resíduos de Praguicidas/química
8.
J Chromatogr A ; 1218(42): 7415-37, 2011 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-21704317

RESUMO

Over the last years, liquid-phase microextraction (LPME) in its different application modes (single drop microextraction, dispersive liquid-liquid microextraction and hollow fiber-LPME) has been increasingly applied for the extraction of both inorganic and organic analytes from different matrices. Its advantages over conventional extraction procedures (simplicity, effectiveness, rapidity and low consumption of organic solvents) has also attracted its application in the complex food analysis field, in which it has clearly provided good and challenging results. A comprehensive review dealing with those articles published since its introduction till the end of March 2011 is presented, offering also a critical vision of the analytical potential of LPME for the analysis of foods.


Assuntos
Análise de Alimentos , Microextração em Fase Líquida , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas em Tandem
9.
J Chromatogr A ; 1218(31): 5352-61, 2011 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-21726875

RESUMO

In this work, a new method for the determination of eleven quinolone antibiotics (moxifloxacin, lomefloxacin, danofloxacin, ciprofloxacin, levofloxacin, marbofloxacin, enrofloxacin, difloxacin, pefloxacin, oxolinic acid and flumequine) in different water samples using dispersive solid-phase extraction (dSPE) and capillary zone electrophoresis with diode-array detection was developed. Oxidized multi-walled carbon nanotubes (o-MWCNTs) were used for the first time as stationary phases for the off-line preconcentration by dSPE of the antibiotics. A 65 mM phosphate buffer at pH 8.5 was found adequate for analyte separation while large volume sample stacking with polarity switching of the analytes dissolved in water containing 10% (v/v) of acetonitrile was carried out in order to improve the sensitivity. dSPE parameters, such as sample volume and pH, o-MWCNT amount, volume and type of eluent in dSPE were optimized. Application of the developed method to the analysis of spiked Milli-Q, mineral, tap, and wastewater samples resulted in good recoveries values ranging from 62.3 to 116% with relative standard deviation values lower than 7.7% in all cases. Limits of detection were in the range of 28-94 ng/L. The proposed method is very fast, simple, repeatable, accurate and highly selective.


Assuntos
Antibacterianos/análise , Eletroforese Capilar/métodos , Nanotubos de Carbono/química , Quinolonas/análise , Quinolonas/isolamento & purificação , Extração em Fase Sólida/métodos , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/isolamento & purificação , Adsorção , Eletroforese Capilar/instrumentação , Oxirredução , Extração em Fase Sólida/instrumentação
10.
J Chromatogr A ; 1217(16): 2618-41, 2010 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-19914625

RESUMO

Since the first report in 1991, carbon nanotubes (CNTs) have shown great possibilities for a wide variety of processes and applications, which include their use as electrodes, sensors (gas, enzymatic, etc.), nanoprobes, electronic materials, field emitters, etc. The combination of structures, dimensions and topologies has provided physical and chemical attractive properties that are unparalleled by most known materials. Their applications have also reached the Analytical Chemistry field in which CNTs are being used as matrices in matrix assisted laser desorption ionization, stationary phases in either gas chromatography, high performance liquid chromatography or capillary electrochromatography, also as pseudostationary phases in capillary electrophoresis, etc. as well as new solid-phase extraction (SPE) materials. Concerning this last application the number of works has considerably increased in the last five years. This review article pretends to focus on the most important features and different applications of SPE using CNTs (including matrix solid-phase dispersion and solid-phase microextraction) covering articles published since their introduction up to now (September 2009).


Assuntos
Nanotubos de Carbono/química , Extração em Fase Sólida/métodos , Compostos Inorgânicos/química , Nanotubos de Carbono/ultraestrutura , Praguicidas/química , Preparações Farmacêuticas/química , Ácidos Ftálicos/química
11.
J Chromatogr A ; 1216(43): 7336-45, 2009 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-19700165

RESUMO

This paper describes a dispersive liquid-liquid microextraction (DLLME) procedure using room temperature ionic liquids (RTILs) coupled to high-performance liquid chromatography with diode array detection capable of quantifying trace amounts of eight pesticides (i.e. thiophanate-methyl, carbofuran, carbaryl, tebuconazole, iprodione, oxyfluorfen, hexythiazox and fenazaquin) in bananas. Fruit samples were first homogenized and extracted (1g) with acetonitrile and after suitable evaporation and reconstitution of the extract in 10 mL of water, a DLLME procedure using 1-hexyl-3-methylimidazolium hexafluorophosphate ([C(6)MIM][PF(6)]) as extraction solvent was used. Experimental conditions affecting the DLLME procedure (sample pH, sodium chloride percentage, ionic liquid amount and volume of disperser solvent) were optimized by means of an experimental design. In order to determine the presence of a matrix effect, calibration curves for standards and fortified banana extracts (matrix matched calibration) were studied. Mean recovery values of the extraction of the pesticides from banana samples were in the range of 69-97% (except for thiophanate-methyl and carbofuran, which were 53-63%) with a relative standard deviation lower than 8.7% in all cases. Limits of detection achieved (0.320-4.66 microg/kg) were below the harmonized maximum residue limits established by the European Union (EU). The proposed method, was also applied to the analysis of this group of pesticides in nine banana samples taken from the local markets of the Canary Islands (Spain). To the best of our knowledge, this is the first application of RTILs as extraction solvents for DLLME of pesticides from samples different than water.


Assuntos
Fracionamento Químico/métodos , Frutas/química , Líquidos Iônicos/química , Musa/química , Resíduos de Praguicidas/análise , Extratos Vegetais/análise , Acetona , Acetonitrilas , Calibragem , Cromatografia Líquida de Alta Pressão , Interpretação Estatística de Dados , Análise de Alimentos/métodos , Concentração de Íons de Hidrogênio , Metanol , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Cloreto de Sódio , Espanha , Temperatura
12.
Electrophoresis ; 29(21): 4412-21, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18956435

RESUMO

In this work, NACE with UV detection is combined with SPE using multi-walled carbon nanotubes (MWCNT) as stationary phase to determine a group of seven pesticides (pirimicarb, pyrifenox, penconazol, carbendazim, cyromazine, pyrimethanil and cyprodinil) in mineral water samples using ametryn as internal standard. The optimized BGE, consisting of a mixture of MeOH and ACN (1:2 v/v) with 90 mM SDS and 20.5 mM HClO(4), was satisfactory to get a good resolution of the seven compounds in less than 13 min. On-line preconcentration was carried out by electrokinetic injection of the sample dissolved in 78:22 v/v MeOH/ACN, 1.11 mM HClO(4). Repeatability was studied for the same day (n=4), for nine different days (n=36) and for four different capillaries. RSD values were appropriate in all cases, i.e. in the range 4.3-9.4% between different capillaries. MWCNT of 10-15 nm od, 2-6 nm id and 0.1-10 mum length were used as SPE materials for the preconcentration of these pesticides from water samples. SPE parameters influencing the enrichment were optimized and the most favorable conditions were as follows: the amount of stationary phase, eluent, sample pH and sample volume were 40 mg MWCNT, 10 mL ACN and 10 mL dichloromethane containing 5% v/v formic acid, pH 8.0, and 750 mL, respectively. Mean recovery values ranged between 53 and 94% for Milli-Q water and between 47 and 93% for mineral waters (RSD values were in the range 2-16%). The method allowed the determination of these pesticides at concentrations below the maximum residue limits established by the European Union legislation (LOD in the range 27-58 ng/L). When the cost, amount and type of the carbon nanotubes used in this work are compared with those carbon nanotubes previously used in the literature it is clear that the proposed materials can be used as economical stationary phases, even cheaper than conventional SPE cartridges.


Assuntos
Águas Minerais/análise , Nanotubos de Carbono , Praguicidas/análise , Poluentes da Água/análise , Calibragem , Eletroforese Capilar , Extração em Fase Sólida
13.
Electrophoresis ; 28(11): 1805-14, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17476718

RESUMO

In this work, a new multiresidue analytical method based on MEKC with UV detection combined with SPE as off-line preconcentration strategy, and reversed-electrode polarity stacking mode (REPSM) as on-line stacking procedure, has been developed for the monitoring of 12 pesticides (carbendazim, pirimicarb, metalaxyl, pyrimethanil, procymidone, nuarimol, azoxystrobin, tebufenozide, fenarimol, benalaxyl, penconazole, and tetradifon) that are currently being used in the Canary Islands (Spain). The optimized MEKC buffer, consisting of 100 mM sodium tetraborate and 30 mM SDS at pH 8.5 with 6% v/v 1-propanol, provided baseline resolution of the 12 pesticides in less than 20 min. The developed method was applied to the analysis of mineral, stagnant, and tap water samples. The proposed SPE-REPSM-MEKC-UV method showed high extraction efficiencies with detection limits (LODs) at the low ng/L level providing LOD values down to 64 ng/L for these real samples.


Assuntos
Cromatografia Capilar Eletrocinética Micelar/métodos , Resíduos de Praguicidas/análise , Extração em Fase Sólida/métodos , Poluentes Químicos da Água/análise , Reprodutibilidade dos Testes , Espectrofotometria Ultravioleta
14.
Electrophoresis ; 28(22): 4072-81, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17957661

RESUMO

In this work, a new method for the determination in white wines of 12 pesticides widely used in vine cultivars (namely, carbendazim, pirimicarb, metalaxyl, pyrimethanil, procymidone, nuarimol, azoxystrobin, tebufenozide, fenarimol, benalaxyl, penconazole, and tetradifon) using solid-phase microextraction (SPME) and MEKC with diode-array detection (DAD) was developed. The MEKC buffer consisted of 100 mM sodium tetraborate and 30 mM SDS at pH 8.5 with 6% v/v 1-propanol. Reversed-electrode polarity stacking mode (REPSM) was applied as on-line preconcentration strategy. In order to carry out an effective and sensitive determination of these pesticides in wine samples, an off-line SPME procedure was optimized by means of an experimental design. After studying the extraction performance of different SPME coatings, PDMS/divinylbenzene (PDMS/DVB) fibers were found the most appropriate for the extraction of most of these pesticides. Carbendazim and metalaxyl could not be extracted from wine samples. Calibration curves for extracted standards and fortified white wines were studied in order to determine the presence of a matrix effect. The combination of both preconcentration procedures (SPME and REPSM) allowed the determination of ten of these pesticides in white wines at concentrations between 0.054 and 0.113 mg/L. (i.e., levels well below the maximum residue limits (MRLs) allowed for these compounds in wine grapes). Ten homemade wines were they analyzed with the optimized method demonstrating the usefulness of the proposed procedure.


Assuntos
Cromatografia Capilar Eletrocinética Micelar/métodos , Praguicidas/análise , Vinho/análise , Contaminação de Alimentos , Concentração Máxima Permitida , Resíduos de Praguicidas/análise , Praguicidas/toxicidade , Microextração em Fase Sólida , Vitis/toxicidade , Vinho/toxicidade
15.
J Sep Sci ; 30(18): 3240-6, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18027361

RESUMO

In this work, the determination of 11 pesticides (pirimicarb, metalaxyl, pyrimethanil, procymidone, nuarimol, azoxystrobin, tebufenozide, fenarimol, benalaxyl, penconazole, and tetradifon) in rose wines by micellar EKC (MEKC) using reversed electrode polarity stacking mode (REPSM) as online preconcentration strategy is described. The MEKC buffer consisted of 100 mM sodium tetraborate and 30 mM SDS at pH 8.5 with 6% v/v 1-propanol. A solid-phase microextraction (SPME) procedure using PDMS/divinylbenzene (PDMS/DVB) fibers was applied to extract the selected pesticides from the rose wine samples. The comparison between the calibration curves obtained from hydroalcoholic solutions (12% v/v ethanol) and from rose wines (matrix matched calibration) showed the existence of a strong matrix effect. Furthermore, a comparison with calibration curves obtained with white wine samples also showed significant differences for most of the analyzed pesticides. As a result, a matrix matched calibration was developed. Quantitative extraction from spiked wine samples was carried out in triplicate at two levels of concentration (range 0.18-6.00 mg/L). LODs between 0.040 and 0.929 mg/L were achieved, which are below the maximum residue limits (MRLs) established for wine grapes (except for pirimicarb) by the EU and Spain legislation as well as by the Codex Alimentarius. The established method - which is solvent free, cost effective, and fast - was also applied to the analysis of several homemade rose wine samples and a commercial one. Two of the selected pesticides were found in some of the analyzed samples.


Assuntos
Cromatografia Capilar Eletrocinética Micelar/métodos , Praguicidas/análise , Rosa/química , Vinho/análise , Calibragem , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA