Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Spine Deform ; 8(5): 845-851, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32449035

RESUMO

STUDY DESIGN: Ex vivo porcine imaging study. OBJECTIVES: Quantitatively evaluate change in MRI signal at the discs caudal to spinal fusion instrumentation. Individuals who receive posterior spinal instrumentation are at risk of developing accelerated disc degeneration at adjacent levels. Degeneration is associated with a loss of biochemical composition and mechanical integrity of the disc, which can be noninvasively assessed through quantitative T2* (qT2*) MRI techniques. However, qT2* is sensitive to magnetic susceptibility introduced by metal. METHODS: Nine ex vivo porcine lumbar specimens were imaged with 3 T MRI. Fast spin-echo T2-weighted (T2w) images and gradient-echo qT2* maps were acquired, both without and with posterior spinal fusion instrumentation. Average T2* relaxation times of the nuclei pulposi (NP) were measured at the adjacent and sub-adjacent discs and measurements were compared using t tests before and after instrumentation. The size of the signal void and metal artifact were determined (modified ASTM F2119-07) within the vertebral body and spinal cord for both MRI sequences. The relationship between T2* signal loss and distance from the instrumentation was evaluated using Pearson's correlation. RESULTS: There was no significant difference between adjacent and sub-adjacent NP T2* relaxation time prior to instrumentation (p = 0.86). Following instrumentation, there was a significant decrease in the T2* relaxation time at the adjacent NP (average = 20%, p = 0.02), and no significant difference at the sub-adjacent NP (average = - 3%, p = 0.30). Furthermore, there was a significant negative correlation between signal loss and distance to disc (r = - 0.61, p < 0.01). CONCLUSIONS: Spinal fusion instrumentation interferes with T2* relaxation time measurements at the adjacent disc but not at the sub-adjacent discs. However, there is sufficient signal at the adjacent disc to quantify changes in the T2* relaxation time following spinal fusion. Hence, baseline MRI scan following spinal fusion surgery are required to interpret and track changes in disc health at the caudal discs. LEVEL OF EVIDENCE: N/A.


Assuntos
Imagem de Difusão por Ressonância Magnética , Degeneração do Disco Intervertebral/diagnóstico por imagem , Degeneração do Disco Intervertebral/etiologia , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Fusão Vertebral/efeitos adversos , Fusão Vertebral/instrumentação , Animais , Artefatos , Degeneração do Disco Intervertebral/patologia , Complicações Pós-Operatórias/patologia , Fusão Vertebral/métodos , Suínos
2.
Chem Commun (Camb) ; 50(38): 4884-7, 2014 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-24647792

RESUMO

Ruthenium(II) PNN complexes depolymerize many polyesters into diols and polycarbonates into glycols plus methanol via hydrogenation. Notably, polyesters with two methylene units between ester linkages depolymerize to carboxylic acids rather than diols. This methodology represents a new approach for producing useful chemicals from waste plastics.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA