Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
J Prosthet Dent ; 2023 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-37353409

RESUMO

STATEMENT OF PROBLEM: Titanium dental implants produced by additive manufacturing have pores that, depending on their size and quantity, may improve osteogenic cell adhesion without impairing mechanical properties. A systematic review of in vitro studies on this topic is lacking. PURPOSE: The purpose of this systematic review was to answer the question "What is the influence of pores on osteogenic cell adhesion on titanium surfaces produced by additive manufacturing?". MATERIAL AND METHODS: The study was designed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) 2020 standards and registered in the Open Science Framework (OSF) (osf.io/baw59). A manual search of published articles without language or time restrictions was conducted in November 2022 in the electronic databases PubMed, Scopus, ScienceDirect, Embase, and in the nonpeer-reviewed literature via Google Scholar. RESULTS: A total of 1338 initial results were found, and after removing duplicates and applying eligibility criteria, 13 articles were included in this review that, according to the Joanna Briggs Institute (JBI) tool, presented a low risk of bias. Pores with larger diameters provide greater a surface area that favors cell filopodia adhesion and has interconnection that optimizes the transport of nutrients and oxygen and bone cell activity. CONCLUSIONS: The presence of pores on the surface of titanium produced by additive manufacturing increases the adhesion, migration, proliferation, and viability of osteogenic cells.

2.
J Prosthet Dent ; 2022 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-35418317

RESUMO

STATEMENT OF PROBLEM: The surface of titanium dental implants treated with a high-power laser has been reported to favor osseointegration, mainly by altering protein uptake. Despite the large number of articles that address the topic, the heterogeneity of methodologies and results makes an understanding of the treatment's benefits difficult, and a systematic review is needed. PURPOSE: The purpose of this systematic review was to further the knowledge on protein uptake on titanium surfaces that have undergone treatment with a high-power laser. MATERIAL AND METHODS: This review followed the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) guidelines and was registered with the Open Science Framework (OSF) (osf.io/gcbna). Searches were performed in PubMed, Scopus, Web of Science, Embase, and Google Scholar databases. The articles were selected in 2 steps by 2 independent reviewers according to the previously selected eligibility criteria. The risk of bias was analyzed by using the Joanna Briggs Institute (JBI)-adapted quasi-experimental study evaluation tool. RESULTS: The studies addressed have shown that applying a high-power laser to the implant surface, depending on its settings, generates topographical changes that can optimize the protein absorption process and thus accelerate the other biological processes. CONCLUSIONS: The studies identified in this systematic review showed that surface treatment with a high-power laser represents a promising technique with a positive influence on protein uptake and osseointegration.

3.
J Oral Implantol ; 41(1): 17-21, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23339297

RESUMO

The purpose of the study was to use scanning electron microscopy and energy dispersive x-ray spectrometry to assess possible morphologic and chemical changes after performing double-insertion and pullout tests of implants of different shapes and surface treatments. Four different types of implants were used-cylindrical machined-surface implants, cylindrical double-surface-treated porous implants, cylindrical surface-treated porous implants, and tapered surface-treated porous implants-representing a total of 32 screws. The implants were inserted into synthetic bone femurs, totaling 8 samples, before performing each insertion with standardized torque. After each pullout the implants were analyzed by scanning electron microscopy and energy dispersive x-ray spectrometry using a universal testing machine and magnified 35 times. No structural changes were detected on morphological surface characterization, only substrate accumulation. As for composition, there were concentration differences in the titanium, oxygen, and carbon elements. Implants with surface acid treatment undergo greater superficial changes in chemical composition than machined implants, that is, the greater the contact area of the implant with the substrate, the greater the oxide layer change. In addition, prior manipulation can alter the chemical composition of implants, typically to a greater degree in surface-treated implants.


Assuntos
Implantes Dentários , Materiais Dentários/química , Condicionamento Ácido do Dente , Substitutos Ósseos/química , Carbono/química , Corrosão Dentária , Implantação Dentária Endóssea/métodos , Planejamento de Prótese Dentária , Análise do Estresse Dentário/instrumentação , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Óxidos/química , Oxigênio/química , Poliuretanos/química , Porosidade , Espectrometria por Raios X , Estresse Mecânico , Propriedades de Superfície , Titânio/química , Torque
4.
Heliyon ; 10(14): e34564, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39113960

RESUMO

The aim of this study was to systematically review the literature to investigate whether silver nanoparticles (AgNPs) have an anti-inflammatory effect in vivo. The guidelines of PRISMA were applied, and a registration was made in PROSPERO. A personalized search of the PubMed, Web of Science, Scopus, Embase, Lilacs, and Google Scholar databases was conducted in September 2023. For the data analysis, the inverse variance in the random effects model was used. The tools of SYRCLE and GRADE were used to assess the risk of bias and the certainty of evidence, respectively. From the 9185 identified studies, 5685 duplicate studies were excluded; 52 were read in full text, and 7 were included in this review. Six studies were evaluated by the meta-analysis, and an increase in anti-inflammatory molecules (SMD -5.22; PI [-6.50, -3.94]) and an increase in anti-inflammatory ones (SMD 5.75; PI [3.79, 7.72]) were observed. Qualitative analysis showed a reduction in pro-inflammatory proteins and in the COX-2 pathway. It was concluded that AgNPs present an anti-inflammatory action in vivo through mechanisms involving the reduction of pro-inflammatory molecules and proteins, the increase of anti-inflammatory molecules, and selective inhibition of the COX-2 pathway.

5.
Int J Oral Maxillofac Implants ; 39(2): 235-242, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38657216

RESUMO

PURPOSE: To analyze the effectiveness of coating of abutments with antimicrobial agents and their influence on the physicochemical and biologic properties of the coated materials. MATERIALS AND METHODS: This work was registered in Open Science Framework (osf.io/6tkcp) and followed the PRISMA protocols. A search of two independent reviewers of articles published up to October 29, 2021, was performed in the Embase, PubMed, Science Direct, and Scopus databases. RESULTS: The databases found a total of 1,474 references. After excluding the duplicates, 1,050 remained. After reading the titles and abstracts and applying the inclusion criteria, 13 articles remained and were read in full. A total of 8 articles were included in this systematic review. Different antimicrobial agents have been used to coat abutments, including graphene oxide, polydopamine, titanium and zirconium nitride, lactoferrin, tetracycline, silver, and doxycycline with varied release times. Titanium-coated silver showed a better antimicrobial agent release time of up to 28 days. Chemical analysis confirmed the presence of antimicrobials on the surface after coating. Different pathogenic microorganisms, such as Streptococcus sanguinis, Streptococcus oralis, and Staphylococcus aureus, were inhibited when in contact with the coated surface. CONCLUSIONS: This review showed that there is still no consensus on which is the better antimicrobial agent and which coated materials have the better performance. However, the association of surface coating of abutments with antimicrobials is feasible and can benefit many patients, which can support their clinical use to favor the healing process and prevent infections that can lead to treatment failure with dental implants.


Assuntos
Anti-Infecciosos , Dente Suporte , Humanos , Anti-Infecciosos/farmacologia , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Dente Suporte/microbiologia , Propriedades de Superfície , Titânio/química
6.
Heliyon ; 10(4): e25525, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38384570

RESUMO

Objective: The aim of this study was to evaluate the roughness, hardness, and color change of pit and fissure sealants of two commercial brands (Fluroshield ™ and Ultraseal XT ™) incorporated with nanostructured silver vanadate nanomaterial decorated with silver nanoparticles (ß-AgVO3) in concentrations (0% - control, 2.5% and 5%). Material and methods: Two commercial brands Fluroshield TM and Ultraseal XT ™ were used to make the samples with dimensions of 6 × 6 × 4 mm. The control group was made according to the manufacturer's instructions and in the groups with the addition of ß-AgVO3, the nanomaterial was added proportionally by mass at percentages of 2.5% and 5%. Roughness properties were evaluated using a 3D Laser Confocal Microscope (n = 10), Knoop microhardness by Microdurometer (n = 10), and color change by Portable Color Spectrophotometer on the CIEDE2000 system (n = 10). Data were evaluated by one-way ANOVA with Bonferroni adjustment and Tukey's mean comparison test at a 5% significance level. Results: Ultraseal XT ™ sealant roughness showed a significant difference between concentrations with the highest mean for the 5% group (P = 0.010). Regarding the hardness, both sealants showed no significant difference between the groups. Fluroshield ™ sealant showed a significant difference in ΔE00 between the control-2.5% 24.93 (3.49) and control-5% 28.41 (2.58). Conclusion: It may be concluded that the incorporation of ß-AgVO3 influenced the increase in roughness for Ultraseal XT ™ pit and fissure sealant, did not interfere with the microhardness of both sealants, and promoted a change in the color of Fluroshield ™ sealant within clinically acceptable limits.

7.
Heliyon ; 10(9): e30108, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38774089

RESUMO

The objective of the systematic review is to find an answer to a question: "What is the influence of the building direction of titanium implants produced by additive manufacturing on their physical and mechanical properties?" This review followed the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA 2020) and was registered in the Open Science Framework (OSF) (osf.io/rdc84). Searches were performed in PubMed, Scopus, Science Direct, Embase, and Google Scholar databases on February 17th, 2024. Articles were chosen in 2 steps by 2 blinded reviewers based on previously selected inclusion criteria: In vitro studies that evaluated the influence of the impression direction of titanium implants produced by additive manufacturing on their physical and mechanical properties were selected. Articles were excluded that (1) did not use additive technology to obtain the implants, 2) used surfaces other than titanium, 3) did not evaluate the direction of impression, 4) Studies with only in vivo analyses, clinical studies, systematic reviews, book chapters, short communications, conference abstracts, case reports, and personal opinions.). In the initial search, 581 results were found. Of this total, 108 were excluded for duplication and, after applying the eligibility criteria, 16 articles were included in the present review. The risk of bias was analyzed using the RoBDEMAT. The risk of bias was analyzed using the RoBDEMAT. In addition, the coefficient of interagreement of the reviewers (Cohen's Kappa) and the certainty of evidence by GRADE were analyzed. In general, different impression angles showed variations in the physical and mechanical characteristics of the groups evaluated, including roughness, tensile strength, hardness, and modulus of elasticity. While some impression orientations resulted in greater strength or hardness, others showed greater elasticity or lower surface roughness. These findings suggest that print orientation plays a significant role in determining material properties. It can be concluded that printing directions influence the physical and mechanical properties of titanium implants and the studies included showed that the 0°, 45°, and 90° directions are the most evaluated as they present lower probabilities of structural anisotropies and provide better results in their roughness, hardness, tensile and compressive strength.

8.
J Dent ; 145: 104836, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38199325

RESUMO

OBJECTIVE: To investigate the impact of incorporating the antimicrobial nanomaterial ß-AgVO3 into orthodontic resin, focusing on degree of conversion, surface characteristics, microhardness, adhesion properties, and antimicrobial activity. METHODS: The 3 M Transbond XT resin underwent modification, resulting in three groups (Control, 2.5% addition, 5% addition) with 20 specimens each. Fourier transform infrared spectroscopy assessed monomer conversion. Laser confocal microscopy examined surface roughness, and microhardness was evaluated using Knoop protocols. Shear strength was measured before and after artificial aging on 36 premolar teeth. Microbiological analysis against S. mutans and S. sanguinis was conducted using the agar diffusion method. RESULTS: Degree of conversion remained unaffected by time (P = 0.797), concentration (P = 0.438), or their interaction (P = 0.187). The 5% group exhibited the lowest surface roughness, differing significantly from the control group (P = 0.045). Microhardness showed no significant differences between concentrations (P = 0.740). Shear strength was highest in the control group (P < 0.001). No significant differences were observed in the samples with or without thermocycling (P = 0.759). Microbial analysis revealed concentration-dependent variations, with the 5% group exhibiting the largest inhibition halo (P < 0.001). CONCLUSIONS: Incorporating ß-AgVO3 at 2.5% and 5% concentrations led to significant differences in surface roughness, adhesion, and antimicrobial activity. Overall, resin modification positively impacted degree of conversion, surface characteristics, microhardness, and antimicrobial activity. Further research is warranted to determine clinically optimal concentrations that maximize antimicrobial benefits while minimizing adverse effects on adhesion properties. CLINICAL SIGNIFICANCE: Incorporating ß-AgVO3 into orthodontic resin could improve patient quality of life by prolonging intervention durability and reducing the impact of cariogenic microorganisms. The study's findings also hold promise for the industry, paving the way for the development of new materials with antimicrobial properties for potential applications in the health sector.


Assuntos
Teste de Materiais , Nanopartículas Metálicas , Resistência ao Cisalhamento , Prata , Streptococcus mutans , Propriedades de Superfície , Vanadatos , Streptococcus mutans/efeitos dos fármacos , Humanos , Prata/química , Prata/farmacologia , Vanadatos/química , Vanadatos/farmacologia , Nanopartículas Metálicas/química , Espectroscopia de Infravermelho com Transformada de Fourier , Dureza , Cimentos de Resina/química , Streptococcus sanguis/efeitos dos fármacos , Braquetes Ortodônticos/microbiologia , Microscopia Confocal , Nanoestruturas/química , Aderência Bacteriana/efeitos dos fármacos , Compostos de Prata/farmacologia , Compostos de Prata/química
9.
Heliyon ; 10(13): e32075, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39091957

RESUMO

Background: This systematic review aimed to answer the question, "What is the efficacy of acupuncture treatment in patients with temporomandibular disorder (TMD) with myofascial pain?". Data sources and study selection: This study followed PRISMA guidelines and was registered in PROSPERO. The electronic search strategy was applied to the Scopus, PubMed, Embase, and Science Direct databases. As inclusion criteria, were selected randomized clinical articles that evaluated patients with myofascial pain symptoms treated by acupuncture without the restriction of time and language. Results: The search in the databases resulted in 286 articles, after removing the duplicates 251 were analyzed by title and abstract. Twenty were selected for full reading and 10 were included in the systematic review. The studies evaluated acupuncture treatments by puncture and laser, auriculotherapy by puncture and laser, and an occlusal device for treating myofascial TMD. Conclusions: Comparing acupuncture with placebo acupuncture, it was observed that it is effective for subjective pain relief and palpation of orofacial structures with immediate results; it should be noted that there is still no specific protocol and that the duration of treatment must be personalized. When comparing it with the occlusal device, the associated treatment has enhanced the results. Future studies are suggested by the current literature gap that prevents the determination of clinical guidelines for effective acupuncture treatment in TMD patients with myofascial pain. Practical implications: Laser and needle puncture acupuncture treatment and laser and needle puncture auriculotherapy have shown favorable results in short-term myofascial pain relief. The need for long-term studies to assess benefits and reduce possible biases is highlighted. Clinical trial registry name: PROSPERO (CRD42021271505).

10.
Dental Press J Orthod ; 29(2): e2423282, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38775601

RESUMO

OBJECTIVE: This study aimed to compare the insertion torque (IT), flexural strength (FS) and surface alterations between stainless steel (SS-MIs) and titanium alloy (Ti-MIs) orthodontic mini-implants. METHODS: Twenty-four MIs (2 x 10 mm; SS-MIs, n = 12; Ti-MIs, n = 12) were inserted on artificial bone blocks of 20 lb/ft3 (20 PCF) and 40 lb/ft3 (40 PCF) density. The maximum IT was recorded using a digital torque meter. FS was evaluated at 2, 3 and 4 mm-deflection. Surface topography and chemical composition of MIs were assessed by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). General linear and mixed models were used to assess the effect of the MI type, bone density and deflection on the evaluated outcomes. RESULTS: The IT of Ti-MIs was 1.1 Ncm greater than that obtained for the SS-MIs (p= 0.018). The IT for MIs inserted in 40 PCF test blocks was 5.4 Ncm greater than that for those inserted in 20 PCF test blocks (p < 0.001). SS-MIs inserted in higher density bone (40 PCF) had significantly higher flexural strength than the other groups, at 2 mm (98.7 ± 5.1 Ncm), 3 mm (112.0 ± 3.9 Ncm) and 4 mm (120.0 ± 3.4 Ncm) of deflection (p< 0.001). SEM evidenced fractures in the Ti-MIs. EDS revealed incorporation of 18% of C and 2.06% of O in the loaded SS-MIs, and 3.91% of C in the loaded Ti-MIs. CONCLUSIONS: Based on the findings of this in vitro study, it seems that SS-MIs offer sufficient stability and exhibit greater mechanical strength, compared to Ti-MIs when inserted into higher density bone.


Assuntos
Ligas Dentárias , Implantes Dentários , Resistência à Flexão , Teste de Materiais , Microscopia Eletrônica de Varredura , Procedimentos de Ancoragem Ortodôntica , Aço Inoxidável , Propriedades de Superfície , Titânio , Torque , Titânio/química , Aço Inoxidável/química , Procedimentos de Ancoragem Ortodôntica/instrumentação , Procedimentos de Ancoragem Ortodôntica/métodos , Ligas Dentárias/química , Técnicas In Vitro , Espectrometria por Raios X , Análise do Estresse Dentário , Humanos , Estresse Mecânico , Densidade Óssea
11.
Antibiotics (Basel) ; 12(6)2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37370313

RESUMO

Few studies have been able to elucidate the correlation of factors determining the strength of interaction between bacterial cells and substrate at the molecular level. The aim was to answer the following question: What biophysical factors should be considered when analyzing the bacterial adhesion strength on titanium surfaces and its alloys for implants quantified by atomic force microscopy? This review followed PRISMA. The search strategy was applied in four databases. The selection process was carried out in two stages. The risk of bias was analyzed. One thousand four hundred sixty-three articles were found. After removing the duplicates, 1126 were screened by title and abstract, of which 57 were selected for full reading and 5 were included; 3 had a low risk of bias and 2 moderated risks of bias. (1) The current literature shows the preference of bacteria to adhere to surfaces of the same hydrophilicity. However, this fact was contradicted by this systematic review, which demonstrated that hydrophobic bacteria developed hydrogen bonds and adhered to hydrophilic surfaces; (2) the application of surface treatments that induce the reduction of areas favorable for bacterial adhesion interfere more in the formation of biofilm than surface roughness; and (3) bacterial colonization should be evaluated in time-dependent studies as they develop adaptation mechanisms, related to time, which are obscure in this review.

12.
Heliyon ; 9(6): e17105, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37484223

RESUMO

The objective of the systematic review is to find an answer to a question: "Do surface treatments on titanium implants produced by additive manufacturing improve osseointegration, compared to untreated surfaces?". This review followed the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA 2020) and was registered in the International Prospective Register of Systematic Reviews (PROSPERO) (CRD42022321351). Searches were performed in PubMed, Scopus, Science Direct, Embase, and Google Scholar databases on March 22nd, 2022. Articles were chosen in 2 steps by 2 blinded reviewers based on previously selected inclusion criteria: articles in animals that addressed the influence of surface treatments on osseointegration in implants produced by additive manufacturing. Articles were excluded that (1) did not use titanium surface, 2) that did not evaluate surface treatments, 3) that did not described osseointegration, 4) Studies with only in vitro analyses, clinical studies, systematic reviews, book chapters, short communications, conference abstracts, case reports and personal opinions.). 1003 articles were found and, after applying the eligibility criteria, 17 were used for the construction of this review. All included studies found positive osseointegration results from performing surface treatments on titanium. The risk of bias was analyzed using the SYRCLE assessment tool. Surface treatments are proposed to promote changes in the microstructure and composition of the implant surface to favor the adhesion of bone cells responsible for osseointegration. It is observed that despite the benefits generated by the additive manufacturing process in the microstructure of the implant surface, surface treatments are still indispensable, as they can promote more suitable characteristics for bone-implant integration. It can be concluded that the surface treatments evaluated in this systematic review, performed on implants produced by additive manufacturing, optimize osseointegration, as it allows the creation of a micro-nano-textured structure that makes the surface more hydrophilic and allows better contact bone-implant.

13.
Cranio ; 40(3): 258-261, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-31905099

RESUMO

Introduction: This study aimed to evaluate the relationship between temporomandibular dysfunction (TMD), anxiety, and sleep disorder (DS) among dentistry students, relating the periods in which they are enrolled.Methods: The study consisted of 90 students: Group 1: 30 first-period students; Group 2: 30 fifth-period students; Group 3: 30 students from the ninth period. The participants responded to the RDC/TMD, Fletcher & Luckett questionnaires, and the Beck Anxiety Inventory to analyze symptoms of TMD, DS, and anxiety.Results: There was an association between TMD, DS, and the period studied. When related to moderate and severe anxiety, the group that had the highest incidence was Group 1 (first period students).Conclusion: The apprehension for what is new can influence the TMD and DS indices, while the greater concern for academic/professional performance can generate higher levels of anxiety.


Assuntos
Transtornos do Sono-Vigília , Transtornos da Articulação Temporomandibular , Ansiedade/complicações , Ansiedade/epidemiologia , Odontologia , Humanos , Prevalência , Transtornos do Sono-Vigília/complicações , Transtornos do Sono-Vigília/epidemiologia , Estudantes , Transtornos da Articulação Temporomandibular/complicações , Transtornos da Articulação Temporomandibular/epidemiologia
14.
Dent Mater ; 38(6): e174-e180, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35525686

RESUMO

OBJECTIVE: To explore the effect of adding different percentages of nanostructured silver vanadate decorated with silver nanoparticles (ß-AgVO3) to dental porcelains, evaluating the antimicrobial activity and the influence on the mechanical properties. METHODS: Thirty-six specimens were made, for each concentration, control group, 0.5%, 1%, 2.5% and 5%, using two commercial brands: IPS InLine and Noritake Cerabien ZR. For the analysis of mechanical properties, the Vickers microhardness test and the roughness test were performed. For the antimicrobial analysis, the XTT and CFU assays were performed. RESULTS: There was a statistically significant difference between groups for mechanical and microbiological analyses. SIGNIFICANCE: The modification of dental porcelains, with the incorporation of ß-AgVO3, influenced the mechanical properties of the material and demonstrated antimicrobial activity at certain concentrations.


Assuntos
Anti-Infecciosos , Nanopartículas Metálicas , Nanoestruturas , Anti-Infecciosos/farmacologia , Porcelana Dentária , Teste de Materiais , Prata/farmacologia , Propriedades de Superfície
15.
Braz Dent J ; 30(1): 47-51, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30864647

RESUMO

The purpose of thisin vitrostudy was to evaluate the influence of a new proposal of implant design and surgical protocol on primary stability in different bone densities. Four groups were tested (n=9): G1 - tapered, cone morse, Ø 4.3 mm x 10 mm in length (Alvim CM); G2 - experimental tapered; G3 - cylindrical, cone morse, Ø 4.0 mm x 11 mm in length (Titamax CM) and G4 - experimental cylindrical. The experimental implants were obtained from a design change in the respective commercial models. The insertion was performed in polyurethane (PU) blocks 0.24 g/cm3(20 pcf) and 0.64 g/cm3(40 pcf), according to different surgical protocols. The primary stability was measured by means of insertion torque (IT) and pullout test. Data were analyzed by ANOVA, Tukey's test (α=0.05) and Pearson's correlation. For IT and pullout, conventional and experimental implants showed no difference between them when inserted in the 20 pcf PU (p>0.05). In the 40 pcf PU, the modified implants exhibited greater IT (p<0.05) and lower pullout (p<0.05) compared to the respective conventional models. The implant design tested associated with the surgical protocol, positively influenced primary stability in higher density bones.


Assuntos
Implantes Dentários , Desenho de Prótese , Procedimentos Cirúrgicos Operatórios/métodos , Humanos , Poliuretanos
16.
Dental press j. orthod. (Impr.) ; 29(2): e2423282, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1557696

RESUMO

ABSTRACT Objective: This study aimed to compare the insertion torque (IT), flexural strength (FS) and surface alterations between stainless steel (SS-MIs) and titanium alloy (Ti-MIs) orthodontic mini-implants. Methods: Twenty-four MIs (2 x 10 mm; SS-MIs, n = 12; Ti-MIs, n = 12) were inserted on artificial bone blocks of 20 lb/ft3 (20 PCF) and 40 lb/ft3 (40 PCF) density. The maximum IT was recorded using a digital torque meter. FS was evaluated at 2, 3 and 4 mm-deflection. Surface topography and chemical composition of MIs were assessed by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). General linear and mixed models were used to assess the effect of the MI type, bone density and deflection on the evaluated outcomes. Results: The IT of Ti-MIs was 1.1 Ncm greater than that obtained for the SS-MIs (p= 0.018). The IT for MIs inserted in 40 PCF test blocks was 5.4 Ncm greater than that for those inserted in 20 PCF test blocks (p < 0.001). SS-MIs inserted in higher density bone (40 PCF) had significantly higher flexural strength than the other groups, at 2 mm (98.7 ± 5.1 Ncm), 3 mm (112.0 ± 3.9 Ncm) and 4 mm (120.0 ± 3.4 Ncm) of deflection (p< 0.001). SEM evidenced fractures in the Ti-MIs. EDS revealed incorporation of 18% of C and 2.06% of O in the loaded SS-MIs, and 3.91% of C in the loaded Ti-MIs. Conclusions: Based on the findings of this in vitro study, it seems that SS-MIs offer sufficient stability and exhibit greater mechanical strength, compared to Ti-MIs when inserted into higher density bone.


RESUMO Objetivo: O objetivo deste estudo foi comparar o torque de inserção (TI), a resistência flexural (RF) e as alterações de superfície em mini-implantes ortodônticos de aço inoxidável (MIs-Ai) e de liga de titânio (MIs-Ti). Métodos: Vinte e quatro MIs (2 x 10 mm; MIs-Ai, n = 12; MIs-Ti, n = 12) foram inseridos em blocos de osso artificial de densidades de 20 lb/ft3 (20 PCF) e 40 lb/ft3 (40 PCF). O torque máximo de inserção foi registrado por meio de um torquímetro digital. A resistência flexural foi avaliada nas deflexões de 2, 3 e 4 mm. Topografia de superfície e composição química dos MIs foram avaliadas por Microscopia Eletrônica de Varredura (MEV) e Espectroscopia de Energia Dispersiva de Raios X (EDS). Modelos lineares gerais e mistos foram utilizados para avaliar o efeito do tipo de MI, da densidade óssea e da deflexão nos desfechos avaliados. Resultados: O TI dos MIs-Ti foi 1,1 Ncm maior do que o obtido para os MIs-Ai (P = 0,018). O TI para MIs inseridos em blocos de teste de 40 PCF foi 5,4 Ncm maior do que para aqueles inseridos em blocos de teste 20 PCF (p < 0,001). MIs-Ai inseridos em osso de maior densidade (40 PCF) apresentaram resistência flexural significativamente maior do que outros grupos, em deflexões de 2 mm (98,7 ± 5,1 Ncm), 3 mm (112,0 ± 3,9 Ncm) e 4 mm (120,0 ± 3,4 Ncm) (p < 0,001). A MEV evidenciou fraturas nos MIs-Ti. A EDS revelou incorporação de 18% de C e 2,06% de O nos MIs-Ai e 3,91% de C nos MIs-Ti, ambos submetidos a testes mecânicos. Conclusões: Com base nos resultados desse estudo in vitro, os MIs-Ai aparentam oferecer adequada estabilidade e maior resistência mecânica, em comparação aos MIs-Ti, quando inseridos em osso de maior densidade.

17.
Braz. j. oral sci ; 22: e230282, Jan.-Dec. 2023. tab
Artigo em Inglês | LILACS, BBO | ID: biblio-1510253

RESUMO

Aim: Evaluate the roughness, microhardness and color change of different Bulk Fill resins when submitted to the condition of gastroesophageal reflux and bulimia. Methods: 60 specimens (n = 10) of Bulk-Fill composite resins were made: M1 ­ Filtek™; M2 ­ Tetric N-Ceram and M3 ­ OPUS, through a matrix 2x6 mm and light cured by the VALO light source. After polishing, initial analyzes (48 hours - T0) of surface roughness (Ra), microhardness (VHN) and color change (ΔE) were performed. To simulate the oral condition of severe gastroesophageal reflux and bulimia, the specimens were immersed in hydrochloric acid (S1) (pH 1.7) 4 minutes a day, for 7 days. Control group specimens were immersed in artificial saliva (S2). Subsequently to immersions, mechanical brushing was performed for 3 minutes, three times a day, simulating 7 days of brushing. And again, the analyzes of Ra, VHN and ΔE were performed (7 days - T1). Thus, hydrochloric acid immersion, mechanical brushing and Ra analysis were repeated at 14 days (T2) and 21 days (T3); and T2, T3 and T4 (3 years) for VHN and ΔE. Results: After Shapiro-Wilk statistical test, ANOVA and Tukey test with Bonferroni adjustment (p>0.05), M3 showed the lowest Ra at all times compared to the other resins, while the highest Ra was at T0. M1 and T1 showed higher VHN. And M2 and T4 showed higher ΔE. Conclusion: Bulk Fill resins can be indicated for patients with Gastroesophageal Reflux and Bulimia, nonetheless, Tetric N-Ceram resin showed the worst results


Assuntos
Cor , Resinas Compostas , Dureza , Ácido Clorídrico , Refluxo Gastroesofágico , Bulimia
18.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1528851

RESUMO

The present study analyzed the microhardness and degree of conversion of three Bulk Fill resins (M1 - Filtek Bulk Fill; M2 - Tetric N-Ceram Bulk Fill and M3 - Opus Bulk Fill) polymerized by single peak and polywave Light-emitting Diode Curing Lights. A total 90 test specimens (n=10) were obtained using a Teflon matrix for the purpose of testing microhardness; and for degree of conversion: 135 specimens (n=5) by using a 2 x 6 cm matrix. The specimens were light polymerized using 3 light sources (L1 - Optilight Max, L2 - Bluephase, L3 - VALO). They were kept in artificial saliva om an oven at 37±1°C during the experiment. The degree of conversion was measured by FTIR 24 h after obtaining each test specimen. The microhardness readouts were performed with a microdurometer at the time intervals of 48 hours (T0), 7 days (T1), 14 days (T2) and 21 days (T3). M1L3 was found to show the highest microhardness values in T2, and M1 showed the lowest degree of conversion in the deep third with L1. It was concluded that Filtek Bulk Fill resin showed the best results in comparison with the other resins.


El presente estudio analizó la microdureza y el grado de conversión de tres resinas Bulk Fill (M1 - Filtek Bulk Fill; M2 - Tetric N-Ceram Bulk Fill y M3 - Opus Bulk Fill) polimerizadas por lámparas de curado de diodo emisor de luz de pico único y polionda. Se obtuvieron un total de 90 especímenes de prueba (n=10) utilizando una matriz de teflón con el propósito de probar la microdureza; y para grado de conversión: 135 especímenes (n=5) utilizando una matriz de 2 x 6 cm. Las muestras se fotopolimerizaron utilizando 3 fuen- tes de luz (L1 - Optilight Max, L2 - Bluephase, L3 - VALO). Se mantuvieron en saliva artificial en estufa a 37 ±1°C durante el experimento. El grado de conversión se midió por FTIR 24 h después de obtener cada muestra de prueba. Las lecturas de microdureza se realizaron con un microdurómetro en los intervalos de tiempo de 48 horas (T0), 7 días (T1), 14 días (T2) y 21 días (T3). Se encontró que M1L3 mostraba los valores más altos de microdureza en T2, y M1 mostraba el grado más bajo de conversión en el tercio profundo con L1. Se concluyó que la resina Filtek Bulk Fill mostró los mejores resultados en comparación con las demás resinas.

19.
Rev. Fac. Odontol. Porto Alegre (Online) ; 62(1): 82-89, jan.-jun. 2021.
Artigo em Português | LILACS, BBO | ID: biblio-1443694

RESUMO

Objetivo: O objetivo deste estudo é fornecer ao cirurgião-dentista conhecimento sobre aspectos gerais da zircônia e abordar a introdução das diferentes gerações. Materiais e métodos: Foi realizada uma pesquisa eletrônica da literatura atual em inglês, incluindo artigos científicos publicados até 2019. Resultados: De acordo com os artigos selecionados, diferenças importantes foram encontradas em relação as novas composições da zircônia, sua microestrutura, diferenças no conteúdo da fase cúbica, e de ítria na fase tetragonal, levando a diferentes propriedades ópticas, mecânicas e de resistência ao envelhecimento. Conclusão: A zircônia é o material mais resistente disponível entre as cerâmicas, com diferenças mecânicas e ópticas entre os materiais disponíveis. A introdução das coroas monolíticas resolveu o problema de lascamento da porcelana de cobertura, mas foram necessárias modificações estruturais para fornecer adequada translucidez.


Purpose: This study aims to provide knowledge to clinicians about general aspects of zirconia and to approach the introduction of different zirconia generations. Methods:An electronic search of the English current literature was conducted including scientific articles published up to 2019. Results: According to the selected articles, important differences were found in terms of the novel compositions of zirconia, microstructures among the materials, differences in cubic phase content and yttria in the tetragonal phase, leading to different optical, mechanical and aging resistance properties. Conclusion: Zirconia is the most resistant material available among ceramics with mechanical and optical differences on available materials. The introduction of the monolithic crowns solving the veneering delamination but struc-tural modifications were necessary to provide adequate translucency


Assuntos
Zircônio/análise , Zircônio/uso terapêutico
20.
J. health sci. (Londrina) ; 23(1): https://revista.pgsskroton.com/index.php/JHealthSci/article/view/7618, 20210330.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1179417

RESUMO

The acrylic resin used for the prosthesis base accumulates biofilm, causing diseases such as stomatitis. The addition of some nanoparticles promotes antimicrobial action. This study incorporated the nanostructured silver vanadate decorated with silver nanoparticles (AgVO3) to the acrylic resin by two methods and evaluated the cytotoxicity for human gingival fibroblasts (HGF) and the released silver and vanadium ions. The concentrations of 0.5, 1, 2.5, and 5% of AgVO3 was incorporated by vacuum spatulation and polymeric film. The vacuum spatulation was performed for 60 s using the Turbomix equipment, and the polymeric film was obtained from the polymer solubilization in chloroform, the film was subjected to a cryogenic grinding, and the powder obtained was manually mixed at the monomer. HGF cell viability was assessed after 24 hours, 7 and 14 days by the MTT assay. The release of silver (Ag) and vanadium (V) ions were quantified by inductively coupled plasma mass spectrometry after 30 days. Kruskal-Wallis and Dunn's test were applied (α = 0.05). The HGF viability was inversely proportional to the incubation time. Both incorporation techniques and the negative and positive control groups presented significant statistical differences (p<0.05). The experimental groups presented no statistical difference compared to the negative control (p>0.05), except the vacuum spatulation group with 5% of AgVO3 that showed greater viability than the negative control (p=0.013) in 24 hours. The release of Ag and V ions was proportional to the concentration of AgVO3 The 5% group presented a significant difference compared to the other groups (p<0.05). In conclusion, the acrylic resin with and without the AgVO3 incorporation had a small cytotoxic potential for HGF in 24 hours, with a lower viability in longer contact times; the release of Ag and V ions was proportional to the concentration of AgVO3, not influencing cell viability. (AU)


A resina acrílica utilizada para a base da prótese acumula biofilme, causando doenças como a estomatite. A adição de algumas nanopartículas promove ação antimicrobiana. Este estudo incorporou o vanadato de prata nanoestruturado decorado com nanopartículas de prata (AgVO3) à resina acrílica por dois métodos e avaliou a citotoxicidade para fibroblastos gengivais humanos (HGF) e os íons prata e vanádio liberados. As concentrações de 0,5%, 1%, 2,5% e 5% de AgVO3 foram incorporadas por espatulação a vácuo e filme polimérico. A espatulação a vácuo foi realizada por 60 s no equipamento Turbomix, e o filme polimérico foi obtido a partir da solubilização do polímero em clorofórmio, o filme foi submetido a uma moagem criogênica e o pó obtido foi misturado manualmente ao monômero. A viabilidade celular de HGF foi avaliada após 24 horas, 7 e 14 dias pelo ensaio de MTT. A liberação de íons prata (Ag) e vanádio (V) foi quantificada por espectrometria de massa com plasma indutivamente acoplado após 30 dias. Os testes de Kruskal-Wallis e Dunn foram aplicados (α=0,05). A viabilidade de HGF foi inversamente proporcional ao tempo de incubação. As técnicas de incorporação e os grupos controle negativo e positivo apresentaram diferença estatisticamente significante (p<0,05). Os grupos experimentais não apresentaram diferença estatística em relação ao controle negativo (p>0,05), exceto o grupo de espatulação a vácuo com 5% de AgVO3 que apresentou maior viabilidade que o controle negativo (p = 0,013) em 24 horas. A liberação de íons Ag e V foi proporcional à concentração de AgVO3. O grupo 5% apresentou diferença significativa em relação aos demais grupos (p <0,05). Em conclusão, a resina acrílica com e sem a incorporação de AgVO3 apresentou um pequeno potencial citotóxico para o HGF em 24 horas, com menor viabilidade nos tempos de maior contato, e a liberação de íons Ag e V foi proporcional à concentração de AgVO3, não influenciando na viabilidade celular. (AU)

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA