Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Rapid Commun Mass Spectrom ; 28(15): 1697-704, 2014 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-24975250

RESUMO

RATIONALE: Polyamides (PA) are among the most used classes of polymers because of their attractive properties. Depending on the nature and proportion of the co-monomers used for their synthesis, they can exhibit a very large range of melting temperatures (Tm ). This study aims at the correlation of data from mass spectrometry (MS) with differential scanning calorimetry (DSC) and X-ray diffraction analyses to relate molecular structure to physical properties such as melting temperature, enthalpy change and crystallinity rate. METHODS: Six different PA copolymers with molecular weights around 3500 g mol(-1) were synthesized with varying proportions of different co-monomers (amino-acid AB/di-amine AA/di-acid BB). Their melting temperature, enthalpy change and crystallinity rate were measured by DSC and X-ray diffraction. Their structural characterization was carried out by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). Because of the poor solubility of PA, a solvent-free sample preparation strategy was used with 2,5-dihydroxybenzoic acid (2,5-DHB) as the matrix and sodium iodide as the cationizing agent. RESULTS: The different proportions of the repeating unit types led to the formation of PA with melting temperatures ranging from 115°C to 185°C. The structural characterization of these samples by MALDI-TOF-MS revealed a collection of different ion distributions with different sequences of repeating units (AA, BB; AB/AA, BB and AB) in different proportions according to the mixture of monomers used in the synthesis. The relative intensities of these ion distributions were related to sample complexity and structure. They were correlated to DSC and X-ray results, to explain the observed physical properties. CONCLUSIONS: The structural information obtained by MALDI-TOF-MS provided a better understanding of the variation of the PA melting temperature and established a structure-properties relationship. This work will allow future PA designs to be monitored.


Assuntos
Nylons/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Varredura Diferencial de Calorimetria , Cristalização , Conformação Molecular , Nylons/análise , Estatística como Assunto , Relação Estrutura-Atividade , Temperatura de Transição , Difração de Raios X
2.
Rapid Commun Mass Spectrom ; 26(11): 1347-54, 2012 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-22555928

RESUMO

RATIONALE: Polyamides (PA) belong to the most used classes of polymers because of their attractive chemical and mechanical properties. In order to monitor original PA design, it is essential to develop analytical methods for the characterization of these compounds that are mostly insoluble in usual solvents. METHODS: A low molecular weight polyamide (PA11), synthesized with a chain limiter, has been used as a model compound and characterized by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). In the solvent-based approach, specific solvents for PA, i.e. trifluoroacetic acid (TFA) and hexafluoroisopropanol (HFIP), were tested. Solvent-based sample preparation methods, dried-droplet and thin layer, were optimized through the choice of matrix and salt. Solvent-based (thin layer) and solvent-free methods were then compared for this low solubility polymer. Ultra-high-performance liquid chromatography/electrospray ionization (UHPLC/ESI)-TOF-MS analyses were then used to confirm elemental compositions through accurate mass measurement. RESULTS: Sodium iodide (NaI) and 2,5-dihydroxybenzoic acid (2,5-DHB) are, respectively, the best cationizing agent and matrix. The dried-droplet sample preparation method led to inhomogeneous deposits, but the thin-layer method could overcome this problem. Moreover, the solvent-free approach was the easiest and safest sample preparation method giving equivalent results to solvent-based methods. Linear as well as cyclic oligomers were observed. Although the PA molecular weights obtained by MALDI-TOF-MS were lower than those obtained by (1)H NMR and acido-basic titration, this technique allowed us to determine the presence of cyclic and linear species, not differentiated by the other techniques. TFA was shown to induce modification of linear oligomers that permitted cyclic and linear oligomers to be clearly highlighted in spectra. CONCLUSIONS: Optimal sample preparation conditions were determined for the MALDI-TOF-MS analysis of PA11, a model of polyamide analogues. The advantages of the solvent-free and solvent-based approaches were shown. Molecular weight determination using MALDI was discussed.


Assuntos
Nylons/química , Cromatografia Líquida de Alta Pressão , Gentisatos/química , Peso Molecular , Nylons/classificação , Iodeto de Sódio/química , Solubilidade , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
3.
Anal Chim Acta ; 808: 3-9, 2014 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-24370089

RESUMO

The structural characterization of polyamides (PA) was achieved by tandem mass spectrometry (MS/MS) with a laser induced dissociation (LID) strategy. Because of interferences for precursor ions selection, two chemical modifications of the polymer end groups were proposed as derivatization strategies. The first approach, based on the addition of a trifluoroacetic acid (TFA) molecule, yields principally to complementary bn and yn product ions. This fragmentation types, analogous to those obtained with peptides or other PA, give only poor characterization of polymer end-groups [1]. A second approach, based on the addition of a basic diethylamine (DEA), permits to fix the charge and favorably direct the fragmentation. In this case, bn ions were not observed. The full characterization of ω end group structure was obtained, in addition to the expected yn and consecutive fragment ions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA