Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Artif Organs ; 39(7): 569-75, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25810063

RESUMO

Evidence suggests a major role for von Willebrand factor (vWF) in left ventricular assist device (LVAD)-associated bleeding. However, the mechanisms of vWF degradation during LVAD support are not well understood. We developed: (i) a simple and inexpensive vortexer model; and (ii) a translational LVAD mock circulatory loop to perform preclinical investigations of LVAD-associated vWF degradation. Whole blood was obtained from LVAD patients (n = 8) and normal humans (n = 15). Experimental groups included: (i) blood from continuous-flow LVAD patients (baseline vs. post-LVAD, n = 8); (ii) blood from normal humans (baseline vs. 4 h in vitro laboratory vortexer, ∼ 2400 rpm, shear stress ∼175 dyne/cm(2) , n = 8); and (iii) blood from normal humans (baseline vs. 12 h HeartMate II mock circulatory loop, 10 000 rpm, n = 7). vWF multimers and degradation fragments were characterized with electrophoresis and immunoblotting. Blood from LVAD patients, blood exposed to in vitro supraphysiologic shear stress, and blood circulated through an LVAD mock circulatory loop demonstrated a similar profile of decreased large vWF multimers and increased vWF degradation fragments. A laboratory vortexer and an LVAD mock circulatory loop reproduced the pathologic degradation of vWF that occurs during LVAD support. Both models are appropriate for preclinical studies of LVAD-associated vWF degradation.


Assuntos
Coração Auxiliar/efeitos adversos , Hemorragia/etiologia , Fator de von Willebrand/metabolismo , Humanos , Multimerização Proteica , Proteólise , Estresse Mecânico , Fator de von Willebrand/química
2.
Circ Heart Fail ; 11(9): e004638, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30354363

RESUMO

Background Gastrointestinal bleeding from angiodysplasia is a major problem in continuous-flow left ventricular assist device (LVAD) patients. LVAD shear stress causes pathologic degradation of VWF (von Willebrand factor). A mechanistic relationship between VWF degradation and angiodysplasia has not been explored. We tested 2 novel hypotheses: (1) clinical hypothesis: VWF fragments are elevated in LVAD patients that develop angiodysplasia and (2) in vitro hypothesis: VWF fragments generated during LVAD support alter angiogenesis, which may contribute to angiodysplasia. Methods and Results Clinical study: Paired blood samples were collected from continuous-flow LVAD patients (n=35). VWF was quantified with immunoblotting. In vitro experiments: (1) To investigate whether LVAD support alters angiogenesis, human endothelial cells were cultured with LVAD patient plasma (n=11). To investigate mechanism, endothelial cells were cultured with VWF fragments produced by exposing human VWF and ADAMTS-13 (VWF protease) to LVAD-like shear stress (175 dyne/cm2, n=8). Clinical study results: in all patients (n=35, mean support 666±430 days), LVAD support degraded high-molecular-weight VWF multimers ( P<0.0001) into low-molecular-weight VWF multimers ( P<0.0001) and VWF fragments ( P<0.0001). In patients with gastrointestinal bleeding from angiodysplasia (n=7), VWF fragments were elevated ( P=0.02) versus nonbleeders. In contrast, in patients with gastrointestinal bleeding without angiodysplasia, VWF fragments were not elevated versus nonbleeders ( P=0.96). In vitro experiments results: LVAD patient plasma caused abnormal angiogenesis with reduced tubule length ( P=0.04) and migration ( P=0.05). Similarly, endothelial cells grown with VWF degradation fragments exhibited reduced tubule length ( P<0.001) and migration ( P=0.01). Conclusions LVAD patients who bled from angiodysplasia had higher levels of VWF fragments than nonbleeders and gastrointestinal bleeders without angiodysplasia. VWF fragments caused abnormal angiogenesis in vitro. These findings suggest that VWF fragments may be a mechanistic link between LVAD support, abnormal angiogenesis, angiodysplasia, and gastrointestinal bleeding.


Assuntos
Angiodisplasia/etiologia , Hemorragia Gastrointestinal/etiologia , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Neovascularização Fisiológica , Função Ventricular Esquerda , Fator de von Willebrand/metabolismo , Adulto , Idoso , Angiodisplasia/sangue , Angiodisplasia/diagnóstico , Angiodisplasia/fisiopatologia , Biomarcadores/sangue , Estudos de Casos e Controles , Células Cultivadas , Feminino , Hemorragia Gastrointestinal/sangue , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/fisiopatologia , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Células Endoteliais da Veia Umbilical Humana/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Proteólise , Resultado do Tratamento
3.
J Thorac Cardiovasc Surg ; 151(6): 1747-1754.e1, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26971377

RESUMO

BACKGROUND: Nonsurgical bleeding is a frequent complication of continuous-flow left ventricular assist device (LVAD) support. Abnormal von Willebrand factor (vWF) metabolism plays a major role. However, the relationship between LVAD speed and vWF degradation is unknown. Recent evidence has demonstrated that supraphysiologic shear stress from continuous-flow LVADs accelerates vWF degradation and causes an acquired vWF deficiency and bleeding. To manage LVAD-associated bleeding, it has been proposed that reduced LVAD speed may decrease shear stress and thereby reduce pathologic vWF metabolism. However, there are little published data to support this clinical practice. We tested the hypothesis that reduced continuous-flow LVAD speed decreases vWF degradation. METHODS: Whole blood was collected from patients before and after the implantation of a HeartMate II continuous-flow LVAD (n = 10) to quantify in vivo vWF degradation. In parallel, to evaluate the relationship between LVAD rpm and vWF degradation, whole blood was collected from human donors (n = 30). Single-donor units of blood circulated in an ex vivo HeartMate II mock circulatory loop for 12 hours at 11,400, 10,000, or 8600 rpm (n = 10/each rpm group). vWF multimers and degradation fragments were characterized with electrophoresis and immunoblot analysis. Paired Student t tests were performed within each group. ANOVA with Tukey post hoc test was performed across groups. RESULTS: In patients, LVAD support reduced large vWF multimers and significantly (P < .05) increased vWF degradation fragments. The profile of vWF degradation was nearly identical between LVAD patients and blood circulated in the LVAD mock circulatory loop. At 11,400, 10,000, and 8600 rpm, decreased large vWF multimers and significantly increased vWF degradation fragments were noted. vWF degradation fragments were not statistically different across the 3 rpm groups or versus LVAD patients, which suggested that LVAD rpm did not influence vWF degradation. CONCLUSIONS: Reduced LVAD speed (within the clinical operational range) did not significantly decrease vWF degradation in a mock circulatory loop with human blood. During bleeding events, reduced LVAD speed, itself, may not diminish vWF degradation.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Doenças de von Willebrand/sangue , Fator de von Willebrand/análise , Adulto , Idoso , Eletroforese em Gel de Poliacrilamida , Feminino , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Estresse Mecânico , Doenças de von Willebrand/etiologia
4.
Tissue Eng Part A ; 22(3-4): 386-95, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26871863

RESUMO

Cartilage has a poor healing response, and few viable options exist for repair of extensive damage. Hyaluronic acid (HA) hydrogels seeded with mesenchymal stem cells (MSCs) polymerized through UV crosslinking can generate functional tissue, but this crosslinking is not compatible with indirect rapid prototyping utilizing opaque anatomic molds. Methacrylate-modified polymers can also be chemically crosslinked in a cytocompatible manner using ammonium persulfate (APS) and N,N,N',N'-tetramethylethylenediamine (TEMED). The objectives of this study were to (1) compare APS/TEMED crosslinking with UV crosslinking in terms of functional maturation of MSC-seeded HA hydrogels; (2) generate an anatomic mold of a complex joint surface through rapid prototyping; and (3) grow anatomic MSC-seeded HA hydrogel constructs using this alternative crosslinking method. Juvenile bovine MSCs were suspended in methacrylated HA (MeHA) and crosslinked either through UV polymerization or chemically with APS/TEMED to generate cylindrical constructs. Minipig porcine femoral heads were imaged using microCT, and anatomic negative molds were generated by three-dimensional printing using fused deposition modeling. Molded HA constructs were produced using the APS/TEMED method. All constructs were cultured for up to 12 weeks in a chemically defined medium supplemented with TGF-ß3 and characterized by mechanical testing, biochemical assays, and histologic analysis. Both UV- and APS/TEMED-polymerized constructs showed increasing mechanical properties and robust proteoglycan and collagen deposition over time. At 12 weeks, APS/TEMED-polymerized constructs had higher equilibrium and dynamic moduli than UV-polymerized constructs, with no differences in proteoglycan or collagen content. Molded HA constructs retained their hemispherical shape in culture and demonstrated increasing mechanical properties and proteoglycan and collagen deposition, especially at the edges compared to the center of these larger constructs. Immunohistochemistry showed abundant collagen type II staining and little collagen type I staining. APS/TEMED crosslinking can be used to produce MSC-seeded HA-based neocartilage and can be used in combination with rapid prototyping techniques to generate anatomic MSC-seeded HA constructs for use in filling large and anatomically complex chondral defects or for biologic joint replacement.


Assuntos
Artroplastia de Quadril , Cartilagem , Ácido Hialurônico/química , Hidrogéis/química , Células-Tronco Mesenquimais , Engenharia Tecidual/métodos , Animais , Bovinos , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/metabolismo , Metacrilatos/química , Suínos , Porco Miniatura
5.
J Thorac Cardiovasc Surg ; 149(1): 281-9, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25439775

RESUMO

OBJECTIVES: Bleeding is an important source of morbidity in patients with a left ventricular assist device. Evidence suggests a major role for von Willebrand factor. However, limited data exist to explain the mechanism(s) of von Willebrand factor degradation during left ventricular assist device support. We investigated whether left ventricular assist device-related shear stress and a disintegrin and metalloproteinase with a thrombospondin type 1 motif, member 13 (ADAMTS-13, the von Willebrand factor protease) altered von Willebrand factor metabolism. METHODS: Whole blood was collected from patients (n = 8) with a left ventricular assist device. von Willebrand factor multimers and degradation fragments were characterized with electrophoresis and immunoblotting. To investigate mechanisms, an in vitro model was developed to generate the supraphysiologic shear stress of a continuous-flow left ventricular assist device. Normal human blood (n = 8) was cycled in a laboratory vortexer (∼2400 rpm, shear stress ∼175 dyne/cm(2), 4 hours) to reproduce the pathologic degradation of von Willebrand factor that occurs during left ventricular assist device support. To investigate the specific mechanistic roles of shear stress and ADAMTS-13 in von Willebrand factor degradation, purified von Willebrand factor protein ± ADAMTS-13 protease were exposed to supraphysiologic shear stress in the vortexer. von Willebrand factor multimers and 11 von Willebrand factor degradation fragments were characterized with electrophoresis and immunoblotting. RESULTS: Left ventricular assist device support reduced large von Willebrand factor multimers and significantly increased 10/11 von Willebrand factor degradation fragments (P < .05). Normal human blood exposed to supraphysiologic shear stress in the vortexer demonstrated the same profile of von Willebrand factor degradation fragments as in a patient with a left ventricular assist device. Supraphysiologic shear stress alone caused modest mechanical demolition of large von Willebrand factor multimers into smaller multimers but did not greatly generate von Willebrand factor fragments. In the presence of supraphysiologic shear stress, ADAMTS-13 completely eliminated large von Willebrand factor multimers and generated statistically significant amounts of 11/11 von Willebrand factor degradation fragments (P < .05). The profile of von Willebrand factor fragments generated was identical to the profile that was observed in vivo in patients with a left ventricular assist device. CONCLUSIONS: Supraphysiologic shear stress alone causes physical demolition of large von Willebrand factor multimers into smaller von Willebrand factor multimers. In the setting of supraphysiologic shear stress, ADAMTS-13 cleaves large von Willebrand factor multimers into von Willebrand factor degradation fragments. ADAMTS-13 may be a therapeutic target to reduce von Willebrand factor degradation and bleeding complications in patients with a left ventricular assist device.


Assuntos
Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Hemorragia/etiologia , Fragmentos de Peptídeos/sangue , Função Ventricular Esquerda , Fator de von Willebrand/metabolismo , Proteínas ADAM/sangue , Proteína ADAMTS13 , Estudos de Casos e Controles , Insuficiência Cardíaca/fisiopatologia , Hemorragia/sangue , Humanos , Modelos Biológicos , Peso Molecular , Fragmentos de Peptídeos/química , Desenho de Prótese , Proteólise , Fatores de Risco , Estresse Mecânico , Resultado do Tratamento , Fator de von Willebrand/química
6.
JACC Heart Fail ; 3(11): 860-9, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26454844

RESUMO

OBJECTIVES: The aim of this study was to investigate a potential therapy for left ventricular assist device (LVAD)-associated bleeding. BACKGROUND: Nonsurgical bleeding is the most frequent complication of LVAD support. Recent evidence has demonstrated that supraphysiological shear stress from continuous-flow LVADs accelerates von Willebrand factor (vWF) metabolism by the action of a disintegrin and metalloproteinase with a thrombospondin type 1 motif, member 13 (ADAMTS-13) (the vWF protease). An acquired vWF deficiency causes bleeding. This suggests that ADAMTS-13 is a clinical target to reduce vWF degradation. We tested the hypothesis that inhibition of ADAMTS-13 with doxycycline, an inexpensive, clinically approved drug, reduces vWF degradation during shear stress. METHODS: Whole blood was collected from human donors (n = 15), and purified, recombinant ADAMTS-13 protein was obtained. An enzyme-linked immunosorbent assay (ELISA) was used to quantify the dose relationship between doxycycline and ADAMTS-13 activity prior to shear stress (n = 10). To determine the effect of shear stress, plasma and recombinant ADAMTS-13 were exposed to LVAD-like supraphysiological shear stress (approximately 175 dyne/cm(2)). vWF multimers and degradation fragments were characterized with electrophoresis and immunoblotting (n = 10). Förster resonance energy transfer was used to quantify plasma ADAMTS-13 activity (n = 10). An ELISA was used to quantify vWF:collagen binding activity. Platelet aggregometry was performed with adenosine 5'-diphosphate, collagen, and ristocetin (vWF-platelet pathway) agonism (n = 10). RESULTS: Doxycycline significantly decreased plasma ADAMTS-13 activity (p = 0.01) and the activity of recombinant human ADAMTS-13 protein by 21%. After plasma was exposed to shear stress, the same pattern of vWF degradation was observed as previously reported for LVAD patients, and vWF:collagen binding activity decreased significantly (p = 0.002). Doxycycline significantly decreased ADAMTS-13 activity (p = 0.04) and the activity of recombinant ADAMTS-13 by 18%, protected large vWF multimers from degradation, and significantly decreased the levels of the 5 smallest vWF fragments by 12 ± 2% (p < 0.05). As a result, vWF:collagen binding activity was significantly restored (p = 0.004). ADAMTS-13 inhibition with doxycycline did not hyperactivate platelets. CONCLUSIONS: Inhibition of ADAMTS-13 by doxycycline decreased vWF degradation and improved vWF function during supraphysiological shear stress without hyperactivating platelets. ADAMTS-13 is a clinical target to reduce vWF degradation, improve vWF function, and potentially reduce bleeding during LVAD support.


Assuntos
Proteínas ADAM/antagonistas & inibidores , Antibacterianos/uso terapêutico , Doxiciclina/uso terapêutico , Coração Auxiliar/efeitos adversos , Hemorragia/etiologia , Hemorragia/prevenção & controle , Fator de von Willebrand/metabolismo , Proteínas ADAM/metabolismo , Proteína ADAMTS13 , Antibacterianos/metabolismo , Doxiciclina/metabolismo , Insuficiência Cardíaca/terapia , Humanos , Desenho de Prótese , Resultado do Tratamento
7.
Biomaterials ; 35(1): 71-82, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24120037

RESUMO

Changes in tissue and organ stiffness occur during development and are frequently symptoms of disease. Many cell types respond to the stiffness of substrates and neighboring cells in vitro and most cell types increase adherent area on stiffer substrates that are coated with ligands for integrins or cadherins. In vivo cells engage their extracellular matrix (ECM) by multiple mechanosensitive adhesion complexes and other surface receptors that potentially modify the mechanical signals transduced at the cell/ECM interface. Here we show that hyaluronic acid (also called hyaluronan or HA), a soft polymeric glycosaminoglycan matrix component prominent in embryonic tissue and upregulated during multiple pathologic states, augments or overrides mechanical signaling by some classes of integrins to produce a cellular phenotype otherwise observed only on very rigid substrates. The spread morphology of cells on soft HA-fibronectin coated substrates, characterized by formation of large actin bundles resembling stress fibers and large focal adhesions resembles that of cells on rigid substrates, but is activated by different signals and does not require or cause activation of the transcriptional regulator YAP. The fact that HA production is tightly regulated during development and injury and frequently upregulated in cancers characterized by uncontrolled growth and cell movement suggests that the interaction of signaling between HA receptors and specific integrins might be an important element in mechanical control of development and homeostasis.


Assuntos
Ácido Hialurônico/farmacologia , Integrinas/fisiologia , Mecanotransdução Celular/efeitos dos fármacos , Mecanotransdução Celular/fisiologia , Células 3T3 , Animais , Proliferação de Células , Células Cultivadas , Matriz Extracelular/efeitos dos fármacos , Ventrículos do Coração/citologia , Ventrículos do Coração/efeitos dos fármacos , Humanos , Camundongos , Microscopia de Força Atômica , Ratos , Ratos Sprague-Dawley
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA