Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Phys Chem Lett ; 6(15): 2969-75, 2015 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-26267190

RESUMO

Characteristics of nanoscale materials are often different from the corresponding bulk properties providing new, sometimes unexpected, opportunities for applications. Here we investigate the properties of 8 nm colloidal nanoparticles of MAPbBr3 perovskites and contrast them to the ones of large microcrystallites representing a bulk. X-ray spectroscopies provide an exciton binding energy of 0.32 ± 0.10 eV in the nanoparticles. This is 5 times higher than the value of bulk crystals (0.084 ± 0.010 eV), and readily explains the high fluorescence quantum yield in nanoparticles. In the bulk, at high excitation concentrations, the fluorescence intensity has quadratic behavior following the Saha-Langmuir model due to the nongeminate recombination of charges forming the emissive exciton states. In the nanoparticles, a linear dependence is observed since the excitation concentration per particle is significantly less than one. Even the bulk shows linear emission intensity dependence at lower excitation concentrations. In this case, the average excitation spacing becomes larger than the carrier diffusion length suppressing the nongeminate recombination. From these considerations we obtain the charge carrier diffusion length in MAPbBr3 of 100 nm.


Assuntos
Compostos de Cálcio/química , Óxidos/química , Titânio/química , Medições Luminescentes , Nanopartículas/química , Espectroscopia Fotoeletrônica , Fótons
2.
Inorg Chem ; 37(23): 6078-6083, 1998 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-11670746

RESUMO

The Fe-O and Fe-N bond lengths at two iron sites of the mixed-valence complex [Fe(3)O(OOCC(CH(3))(3))(6)(C(5)H(5)N)(3)] show a pronounced temperature dependence; the bonds from two of the Fe atoms to the central oxygen atoms vary by more than 0.10 Å on cooling to 10 K whereas the bond from the third iron atom is essentially invariant. The variation is such that the longest Fe-O bonds at ambient temperature are the shorter ones at 10 K, with the crossover occurring at about 90 K. The bonds to the axial pyridine ligand show the opposite dependence. The variation is attributed to an equilibrium between different configurations, which interconvert through vibronic coupling, a process that involves electron transfer between the metal atoms. The position of the absorption edge for each of the iron atoms has been determined by resonance-diffraction experiments at the Fe K edge, performed at four different temperatures. At each temperature, the order of the absorption edges corresponds to that of the experimentally determined bond lengths. The crossover near 90 K is confirmed by the resonance experiments. The absorption-edge positions are related to the formal oxidation state by calibration with reference complexes of known oxidation state. The experiments demonstrate the close relation between the changes in coordination geometry and the oxidation states of the iron atoms.

3.
Rev Sci Instrum ; 79(8): 085105, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19044378

RESUMO

A new dedicated high-resolution high-throughput powder diffraction beamline has been built, fully commissioned, and opened to general users at the Advanced Photon Source. The optical design and commissioning results are presented. Beamline performance was examined using a mixture of the NIST Si and Al(2)O(3) standard reference materials, as well as the LaB6 line-shape standard. Instrumental resolution as high as 1.7 x 10(-4) (DeltaQQ) was observed.

4.
J Synchrotron Radiat ; 15(Pt 5): 427-32, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18728312

RESUMO

A dedicated high-resolution high-throughput X-ray powder diffraction beamline has been constructed at the Advanced Photon Source (APS). In order to achieve the goals of both high resolution and high throughput in a powder instrument, a multi-analyzer detector system is required. The design and performance of the 12-analyzer detector system installed on the powder diffractometer at the 11-BM beamline of APS are presented.


Assuntos
Difração de Raios X/métodos , Desenho de Equipamento/métodos , Difração de Pó/métodos , Síncrotrons/instrumentação , Difração de Raios X/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA