Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Biomech Eng ; 139(10)2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-28753691

RESUMO

Homografts and synthetic grafts are used in surgery for congenital heart disease (CHD). Determining these materials' mechanical properties will aid in understanding tissue behavior when subjected to abnormal CHD hemodynamics. Homograft tissue samples from anterior/posterior aspects, of ascending/descending aorta (AA, DA), innominate artery (IA), left subclavian artery (LScA), left common carotid artery (LCCA), main/left/right pulmonary artery (MPA, LPA, RPA), and synthetic vascular grafts, were obtained in three orientations: circumferential, diagonal (45 deg relative to circumferential direction), and longitudinal. Samples were subjected to uniaxial tensile testing (UTT). True strain-Cauchy stress curves were individually fitted for each orientation to calibrate Fung model. Then, they were used to calibrate anisotropic Holzapfel-Gasser model (R2 > 0.95). Most samples demonstrated a nonlinear hyperelastic strain-stress response to UTT. Stiffness (measured by tangent modulus at different strains) in all orientations were compared and shown as contour plots. For each vessel segment at all strain levels, stiffness was not significantly different among aspects and orientations. For synthetic grafts, stiffness was significantly different among orientations (p < 0.042). Aorta is significantly stiffer than pulmonary artery at 10% strain, comparing all orientations, aspects, and regions (p = 0.0001). Synthetic grafts are significantly stiffer than aortic and pulmonary homografts at all strain levels (p < 0.046). Aortic, pulmonary artery, and synthetic grafts exhibit hyperelastic biomechanical behavior with anisotropic effect. Differences in mechanical properties among vascular grafts may affect native tissue behavior and ventricular/arterial mechanical coupling, and increase the risk of deformation due to abnormal CHD hemodynamics.


Assuntos
Aloenxertos , Aorta/fisiologia , Aorta/cirurgia , Artéria Pulmonar/fisiologia , Artéria Pulmonar/cirurgia , Estresse Mecânico , Enxerto Vascular , Adulto , Anisotropia , Fenômenos Biomecânicos , Simulação por Computador , Humanos , Hidrodinâmica , Pessoa de Meia-Idade , Modelos Biológicos
2.
J Biomech Eng ; 136(7)2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24441718

RESUMO

Stroke is the most devastating complication after ventricular assist device (VAD) implantation, with an incidence of 14%-47% despite improvements in device design and anticoagulation. This complication continues to limit the widespread implementation of VAD therapy. Patient-specific computational fluid dynamics (CFD) analysis may elucidate ways to reduce this risk. A patient-specific three-dimensional model of the aortic arch was generated from computed tomography. A 12 mm VAD outflow-graft (VAD-OG) "anastomosed" to the aorta was rendered. CFD was applied to study blood flow patterns. Particle tracks, originating from the VAD, were computed with a Lagrangian phase model and percentage of particles entering the cerebral vessels was calculated. Twelve implantation configurations of the VAD-OG and three particle sizes (2, 4, and 5 mm) were considered. Percentage of particles entering the cerebral vessels ranged from 6% for the descending aorta VAD-OG anastomosis, to 14% for the ascending aorta at 90 deg VAD-OG anastomosis. Values were significantly different among all configurations (X(2) = 3925, p < 0.0001). Shallower and more cephalad anastomoses prevented formation of zones of recirculation in the ascending aorta. In this computational model and within the range of anatomic parameters considered, the percentage of particles entering the cerebral vessels from a VAD-OG is reduced by nearly 60% by optimizing outflow-graft configuration. Ascending aorta recirculation zones, which may be thrombogenic, can also be eliminated. CFD methods coupled with patient-specific anatomy may aid in identifying the optimal location and angle for VAD-OG anastomosis to minimize stroke risk.


Assuntos
Vasos Sanguíneos , Coração Auxiliar/efeitos adversos , Embolia Intracraniana/etiologia , Embolia Intracraniana/prevenção & controle , Modelagem Computacional Específica para o Paciente , Próteses e Implantes , Aorta Torácica/fisiopatologia , Vasos Sanguíneos/fisiopatologia , Humanos , Hidrodinâmica , Tamanho da Partícula , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA