J Thorac Cardiovasc Surg ; 116(4): 628-32, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9766592

RESUMO

INTRODUCTION: In the United States, venovenous extracorporeal life support has traditionally been performed with atrial drainage and femoral reinfusion (atrio-femoral flow). Although flow reversal (femoro-atrial flow) may alter recirculation and extracorporeal flow, no direct comparison of these 2 modes has been undertaken. OBJECTIVE: Our goal was to prospectively compare atrio-femoral and femoro-atrial flow in adult venovenous extracorporeal life support for respiratory failure. METHODS: A modified bridge enabling conversion between atrio-femoral and femoro-atrial flow was incorporated in the extracorporeal circuit. Bypass was initiated in the direction that provided the highest pulmonary arterial mixed venous oxygen saturation, and the following measurements were taken: (1) maximum extracorporeal flow, (2) highest achievable pulmonary arterial mixed venous oxygen saturation, and (3) flow required to maintain the same pulmonary arterial mixed venous oxygen saturation in both directions. Flow direction was then reversed, and the measurements were repeated. Data were compared with paired t tests and are presented as mean +/- standard deviation. RESULTS: Ten patients were studied, and 9 were included in the data analysis. Femoro-atrial bypass provided (1) higher maximal extracorporeal flow (femoro-atrial flow = 55.6 +/- 9.8 mL/kg per minute, atrio-femoral flow = 51.1 +/- 11.1 mL/kg per minute; P = .04) and (2) higher pulmonary arterial mixed venous oxygen saturation (femoroatrial flow = 89.9% +/- 6.6%, atrio-femoral flow = 83.2% +/- 4.2%; P = .006); (3) furthermore, it required less flow to maintain an equivalent pulmonary arterial mixed venous oxygen saturation (femoro-atrial flow = 37.0 +/- 12.2 mL/kg per minute, atrio-femoral flow = 46.4 +/- 8.8 mL/kg per minute; P = .04). CONCLUSIONS: During venovenous extracorporeal life support, femoro-atrial bypass provided higher maximal extracorporeal flow, higher pulmonary arterial mixed venous oxygen saturation, and required comparatively less flow to maintain an equivalent mixed venous oxygen saturation than did atrio-femoral bypass.


Assuntos
Oxigenação por Membrana Extracorpórea/instrumentação , Veia Femoral , Átrios do Coração , Cuidados para Prolongar a Vida/instrumentação , Insuficiência Respiratória/terapia , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Cateteres de Demora , Feminino , Humanos , Masculino , Oxigênio/sangue , Estudos Prospectivos , Artéria Pulmonar , Resultado do Tratamento
2.
J Crit Care ; 13(1): 26-36, 1998 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9556124

RESUMO

OBJECTIVES: The purpose of this article is to evaluate outcome in adult patients with severe respiratory failure managed with an approach using (1) limitation of end inspiratory pressure, (2) inverse ratio ventilation, (3) titration of PEEP by SvO2, (4) intermittent prone positioning, (5) limitation of FiO2, (6) diuresis, (7) transfusion, and (8) extracorporeal life support (ECLS) if patients failed to respond. PATIENTS AND METHODS: This study was designed as a retrospective review in the intensive care unit of a tertiary referral hospital. One-hundred forty-one consecutive patients with hypoxic (n = 135) or hypercarbic (n = 6) respiratory failure referred for consideration of ECLS between 1990 and 1996. Overall, initial PaO2/FiO2 (P/F) ratio was 75+/-5 (median = 66). RESULTS: Lung recovery occurred in 67% of patients and 62% survived. Forty-one patients improved without ECLS (83% survived); 100 did not and were supported with ECLS (54% survived). Survival was greater in patients cannulated within 12 hours of arrival (59%) compared with those cannulated after 12 hours (40%, P < .05). Multiple logistic regression identified age, duration of mechanical ventilation before transfer, four or more dysfunctional organs, and the requirement for ECLS as independent predictors of mortality. CONCLUSIONS: An approach that emphasizes lung protection and early implementation of extracorporeal life support is associated with high rates of survival in patients with severe respiratory failure.


Assuntos
Cuidados para Prolongar a Vida , Respiração com Pressão Positiva/métodos , Síndrome do Desconforto Respiratório/terapia , Adolescente , Adulto , Fatores Etários , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Síndrome do Desconforto Respiratório/mortalidade , Fatores de Risco , Análise de Sobrevida , Resultado do Tratamento
3.
ASAIO J ; 44(4): 263-6, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-9682951

RESUMO

Traditionally, adult sepsis has been considered a contraindication to extracorporeal life support (ECLS). The objective of this study was to review the authors' institutional experience with a subgroup of adult patients requiring ECLS for severe respiratory failure and sepsis. Hospital records from 100 consecutive adult patients with respiratory failure placed on ECLS between 1990 and 1996 were retrospectively reviewed. Patients with sepsis as a primary indication were identified, and blood culture data reviewed. Data were analyzed with t tests and chi-square and are presented as mean +/- standard deviation. Multiple logistic regression determined the impact of sepsis and positive blood cultures (PBCs) on survival. Fourteen patients required ECLS for sepsis; 36 had PBCs during hospitalization (15 before or during ECLS). Septic patients had lower pre-ECLS PaO2/FIO2 ratios (septic: 53 +/- 14 mmHg, nonseptic: 70 +/- 68 mmHg, p = 0.04). Patients with PBCs before or during ECLS were younger (PBC: 29 +/- 6 years, no PBC: 35 +/- 13 years, p = 0.003), remained on ECLS longer (PBC: 485 +/- 336 hours, no PBC: 232 +/- 212 hours, p = 0.01), and were more frequently cannulated within 12 hours (PBC: 15/15, no PBC 60/85 p = 0.02). Neither group differed in organ dysfunction (incidence or type), frequency of respiratory recovery, or survival. Neither sepsis nor positive blood cultures were independently predictive of mortality. Sepsis and positive blood cultures do not adversely affect outcome in adult patients with respiratory failure requiring ECLS.


Assuntos
Cuidados para Prolongar a Vida/métodos , Insuficiência Respiratória/complicações , Sepse/complicações , Adulto , Idoso , Distribuição de Qui-Quadrado , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Respiração Artificial , Insuficiência Respiratória/microbiologia , Insuficiência Respiratória/terapia , Estudos Retrospectivos , Sepse/microbiologia , Sepse/terapia , Testes Sorológicos , Resultado do Tratamento
4.
ASAIO J ; 43(5): M745-9, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9360145

RESUMO

Extraction of protein bound liver failure toxins, such as unconjugated bilirubin, short chain fatty acids, and aromatic amino acids has been reported using hemodiafiltration with albumin in the dialysate, but the characteristics of such a system have not been described. Therefore, bilirubin clearance using albumin dialysate hemodiafiltration was evaluated in the setting of different dialysate albumin concentrations, varying temperature and pH. An in vitro continuous hemodiafiltration circuit was used with single pass countercurrent dialysis. Unconjugated bilirubin was added to bovine blood and filtered across a polyalkyl sulfone (PAS) hemofilter using matched filtration and dialysate flow rates. The serial bilirubin content was measured and first order clearance kinetics verified. The clearance rate constants were calculated for three dialysate groups of different albumin concentration at constant temperature and pH (group 1: 10 g/dl albumin, n = 5; 2 g/dl albumin, n = 5; normal saline, n = 5), and three groups of different temperature and pH at constant albumin dialysate concentration (group 2: pH = 7.0, temperature = 20 degrees C, n = 5; pH = 7.5, temperature = 20 degrees C, n = 5; pH = 7.0, temperature = 40 degrees C, n = 5). Comparisons were made with ANOVA and Tukey post hoc analysis. When albumin was used in the dialysate, the 2 g/dl group cleared bilirubin 3.1 times faster than saline alone (p = 0.001), and the 10 g/dl group was superior to both (p = 0.001). There were no measurable differences between the 2 g/dl groups at the various temperatures tested (p = 0.08), but the clearance was less at a pH of 7.5 (p = 0.015). The clearance of unconjugated bilirubin is greatly enhanced with the use of albumin containing dialysates when compared to traditional crystalloid hemodiafiltration, is greater at lower pH, and seems to be unaffected by temperature.


Assuntos
Bilirrubina/sangue , Bilirrubina/isolamento & purificação , Hemodiafiltração/métodos , Albuminas , Animais , Bovinos , Estudos de Avaliação como Assunto , Hemodiafiltração/instrumentação , Soluções para Hemodiálise , Encefalopatia Hepática/sangue , Encefalopatia Hepática/terapia , Humanos , Concentração de Íons de Hidrogênio , Técnicas In Vitro , Temperatura
5.
ASAIO J ; 45(1): 47-9, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-9952006

RESUMO

Patients with acute hepatic failure (AHF) have elevated levels of inflammatory cytokines such as tumor necrosis factor alpha (TNF-alpha) and interleukin 6 (IL-6). Recently, we have shown selective hemodiafiltration with albumin dialysis, as an extracorporeal liver support device (ECLVS), to be effective in the clearance of multiple toxins that are elevated in AHF. Our objective was to evaluate whether ECLVS would be effective in the clearance of TNF-alpha and IL-6. An in vitro continuous hemodiafiltration circuit was used with single pass counter-current dialysis. A known amount of recombinant rat TNF-alpha and IL-6 was added to heparinized bovine blood and filtered across a polyalkyl sulfone hemofilter using matched filtration and dialysate flow rates. During 4 hours, the serial TNF-alpha and IL-6 concentrations were measured in the circulating blood, and the content of each cytokine was calculated using mass balance. For each cytokine, clearance was determined for two dialysate groups at constant temperature and pH (group 1: dialysate = 0.9 normal saline, n = 5; group 2: dialysate = albumin 2 gm/dl, n = 5). Analysis of data was performed using ANOVA and Student's t-test. There was improved clearance of TNF-alpha and IL-6 when albumin was used in the dialysate (81+/-0.09% of the initial TNF-alpha and 77+/-0.04% of the IL-6 quantities) compared with when 0.9 normal saline was used as the dialysate (58+/-0.14% of the initial TNF-alpha and 56+/-0.18% of the IL-6 quantities); p < 0.03. An ECLVS utilizing hemodiafiltration with albumin dialysis is more effective than conventional hemofiltration in the clearance of TNF-alpha and IL-6 and, therefore, may benefit patients with acute hepatic failure.


Assuntos
Albuminas/administração & dosagem , Hemodiafiltração/métodos , Soluções para Hemodiálise/administração & dosagem , Interleucina-6/sangue , Fator de Necrose Tumoral alfa/farmacocinética , Análise de Variância , Animais , Bovinos , Humanos , Concentração de Íons de Hidrogênio , Ratos , Cloreto de Sódio/administração & dosagem
7.
Ann Surg ; 226(4): 544-64; discussion 565-6, 1997 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9351722

RESUMO

OBJECTIVE: The authors retrospectively reviewed their experience with extracorporeal life support (ECLS) in 100 adult patients with severe respiratory failure (ARF) to define techniques, characterize its efficacy and utilization, and determine predictors of outcome. SUMMARY BACKGROUND DATA: Extracorporeal life support maintains gas exchange during ARF, providing diseased lungs an optimal environment in which to heal. Extracorporeal life support has been successful in the treatment of respiratory failure in infants and children. In 1990, the authors instituted a standardized protocol for treatment of severe ARF in adults, which included ECLS when less invasive methods failed. METHODS: From January 1990 to July 1996, the authors used ECLS for 100 adults with severe acute hypoxemic respiratory failure (n = 94): paO2/FiO2 ratio of 55.7+/-15.9, transpulmonary shunt (Qs/Qt) of 52+/-22%, or acute hypercarbic respiratory failure (n = 6): paCO2 84.0+/-31.5 mmHg, despite and after maximal conventional ventilation. The technique included venovenous percutaneous access, lung "rest," transport on ECLS, minimal anticoagulation, hemofiltration, and optimal systemic oxygen delivery. RESULTS: Overall hospital survival was 54%. The duration of ECLS was 271.9+/-248.6 hours. Primary diagnoses included pneumonia (49 cases, 53% survived), adult respiratory distress syndrome (45 cases, 51 % survived), and airway support (6 cases, 83% survived). Multivariate logistic regression modeling identified the following pre-ECLS variables significant independent predictors of outcome: 1) pre-ECLS days of mechanical ventilation (p = 0.0003), 2) pre-ECLS paO2/FiO2 ratio (p = 0.002), and 3) age (years) (p = 0.005). Modeling of variables during ECLS showed that no mechanical complications were independent predictors of outcome, and the only patient-related complications associated with outcome were the presence of renal failure (p < 0.0001) and significant surgical site bleeding (p = 0.0005). CONCLUSIONS: Extracorporeal life support provides life support for ARF in adults, allowing time for injured lungs to recover. In 100 patients selected for high mortality risk despite and after optimal conventional treatment, 54% survived. Extracorporeal life support is extraordinary but reasonable treatment in severe adult respiratory failure. Predictors of survival exist that may be useful for patient prognostication and design of future prospective studies.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Respiratória/terapia , Adolescente , Adulto , Causas de Morte , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Pneumonia/complicações , Radiografia , Síndrome do Desconforto Respiratório/complicações , Testes de Função Respiratória , Insuficiência Respiratória/sangue , Insuficiência Respiratória/diagnóstico por imagem , Insuficiência Respiratória/etiologia , Estudos Retrospectivos , Índice de Gravidade de Doença
8.
J Surg Res ; 94(2): 167-71, 2000 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11104657

RESUMO

BACKGROUND: Stable and reproducible large animal models of hepatic failure, which allow the assessment of liver-assist devices, are not available. Our objective was to develop a physiologically stable animal model of hepatic failure on which the safety and efficacy of an extracorporeal liver-assist device can be tested. We hypothesized that a surgical model which consists of an end-to-side portocaval shunt combined with common bile duct ligation and transection would create hepatic failure with: (1) elevations in amino transferases, total bilirubin, and ammonia; (2) a decrease in the ratio of branched chain to aromatic amino acids; and (3) histologic evidence of hepatic injury. METHODS: Eleven mongrel dogs underwent common bile duct transection and an end-to-side portocaval shunt. Aminotransferases (AST, ALT), total bilirubin, ammonia, and branched chain and aromatic amino acids were measured prior to operation (baseline) and after 9 days. A necropsy was performed on Postoperative Day 9 and liver biopsies were obtained for histology. RESULTS: By Postoperative Day 9, AST, ALT, total bilirubin, and ammonia values were significantly elevated compared to baseline (P < 0.02). The ratio of branched chain to aromatic amino acids was significantly reduced compared to baseline (P < 0.003). There was histologic evidence of cholestasis and inflammation. CONCLUSION: Portocaval shunt with common bile duct transection produces liver failure with elevations in aminotransferases, total bilirubin, and ammonia, a decreased branched chain to aromatic amino acid ratio, and histologic inflammation. Unlike ischemic or chemically induced models of liver failure, the dogs were hemodynamically and neurologically stable. This model can be used to test the safety and efficacy of liver-assist devices aimed at temporizing the detoxification functions of the failing liver.


Assuntos
Falência Hepática/fisiopatologia , Alanina Transaminase/sangue , Aminoácidos de Cadeia Ramificada/sangue , Aminoácidos Cíclicos/sangue , Amônia/sangue , Animais , Aspartato Aminotransferases/sangue , Bilirrubina/sangue , Biomarcadores/sangue , Ducto Colédoco/fisiologia , Modelos Animais de Doenças , Cães , Hemodinâmica , Fígado/patologia , Falência Hepática/patologia , Falência Hepática/terapia , Fígado Artificial , Neutrófilos/patologia , Derivação Portocava Cirúrgica , Reprodutibilidade dos Testes
9.
J Trauma ; 49(5): 903-11, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11086784

RESUMO

BACKGROUND: We examined the effects of decreasing respiratory rate (RR) at variable inspiratory times (It) and reducing inspiratory flow on the development of ventilator-induced lung injury. METHODS: Forty sheep weighing 24.6+/-3.2 kg were ventilated for 6 hours with one of five strategies (FIO2 = 1.0, positive end-expiratory pressure = 5 cm H2O): (1) pressure-controlled ventilation (PCV), RR = 15 breaths/min, peak inspiratory pressure (PIP) = 25 cm H2O, n = 8; (2) PCV, RR = 15 breaths/min, PIP = 50 cm H2O, n = 8; (3) PCV, RR = 5 breaths/min, PIP = 50 cm H2O, It = 6 seconds, n = 8; (4) PCV, RR = 5 breaths/min, PIP = 50 cm H2O, It = 2 seconds, n = 8; and (5) limited inspiratory flow volume-controlled ventilation, RR = 5 breaths/min, pressure-limit = 50 cm H2O, flow = 15 L/min, n = 8. RESULTS: Decreasing RR at conventional flows did not reduce injury. However, limiting inspiratory flow rate (LIFR) maintained compliance and resulted in lower Qs/Qt (HiPIP = 38+/-18%, LIFR = 19+/-6%, p < 0.001), reduced histologic injury (HiPIP = 14+/-0.9, LIFR = 2.2+/-0.9, p < 0.05), decreased intra-alveolar neutrophils (HiPIP = 90+/-49, LIFR = 7.6+/-3.8,p = 0.001), and reduced wet-dry lung weight (HiPIP = 87.3+/-8.5%, LIFR = 40.8+/-17.4%,p < 0.001). CONCLUSIONS: High-pressure ventilation for 6 hours using conventional flow patterns produces severe lung injury, irrespective of RR or It. Reduction of inspiratory flow at similar PIP provides pulmonary protection.


Assuntos
Modelos Animais de Doenças , Capacidade Inspiratória , Respiração com Pressão Positiva/métodos , Respiração Artificial/efeitos adversos , Respiração , Síndrome do Desconforto Respiratório/etiologia , Síndrome do Desconforto Respiratório/prevenção & controle , Animais , Hemodinâmica , Contagem de Leucócitos , Complacência Pulmonar , Neutrófilos/patologia , Tamanho do Órgão , Síndrome do Desconforto Respiratório/classificação , Síndrome do Desconforto Respiratório/patologia , Síndrome do Desconforto Respiratório/fisiopatologia , Ovinos , Fatores de Tempo
10.
J Trauma ; 46(4): 638-45, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10217227

RESUMO

OBJECTIVE: To present a series of 30 adult trauma patients who received extracorporeal life support (ECLS) for pulmonary failure and to retrospectively review variables related to their outcome. METHODS: In a Level I trauma center between 1989 and 1997, ECLS with continuous heparin anticoagulation was instituted in 30 injured patients older than 15 years. Indication was for an estimated mortality risk greater than 80%, defined by a PaO2: FIO2 ratio less than 100 on 100% FIO2, despite pressure-mode inverse ratio ventilation, optimal positive end-expiratory pressure, reasonable diuresis, transfusion, and prone positioning. Retrospective analysis included demographic information (age, gender, Injury Severity Score, injury mechanism), pulmonary physiologic and gas-exchange values (pre-ECLS ventilator days [VENT days], PaO2:FIO2 ratio, mixed venous oxygen saturation [SvO2], and blood gas), pre-ECLS cardiopulmonary resuscitation, complications of ECLS (bleeding, circuit problems, leukopenia, infection, pneumothorax, acute renal failure, and pressors on ECLS), and survival. RESULTS: The subjects were 26.3+/-2.1 years old (range, 15-59 years), 50% male, and had blunt injury in 83.3%. Pulmonary recovery sufficient to wean the patient from ECLS occurred in 17 patients (56.7%), and 50% survived to discharge. Fewer VENT days and more normal SvO2 were associated with survival. The presence of acute renal failure and the need for venoarterial support (venoarterial bypass) were more common in the patients who died. Bleeding complications (requiring intervention or additional transfusion) occurred in 58.6% of patients and were not associated with mortality. Early use of ECLS (VENT days < or = 5) was associated with an odds ratio of 7.2 for survival. Fewer VENT days was independently associated with survival in a logistic regression model (p = 0.029). Age, Injury Severity Score, and PaO2:FIO2 ratio were not related to outcome. CONCLUSION: ECLS has been safely used in adult trauma patients with multiple injuries and severe pulmonary failure. In our series, early implementation of ECLS was associated with improved survival. Although this may represent selection bias for less intractable forms of acute respiratory distress syndrome, it is our experience that early institution of ECLS may lead to improved oxygen delivery, diminished ventilator-induced lung injury, and improved survival.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Respiratória/terapia , Ferimentos e Lesões/complicações , Adolescente , Adulto , Feminino , Humanos , Escala de Gravidade do Ferimento , Cuidados para Prolongar a Vida , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Respiração com Pressão Positiva , Troca Gasosa Pulmonar , Sistema de Registros , Insuficiência Respiratória/classificação , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/mortalidade , Estudos Retrospectivos , Resultado do Tratamento
11.
Crit Care Med ; 27(5): 941-5, 1999 May.
Artigo em Inglês | MEDLINE | ID: mdl-10362417

RESUMO

OBJECTIVE: To date, studies of partial liquid ventilation (PLV) have examined its effects acutely in anesthetized and mechanically ventilated subjects. We set out to develop a model of prolonged PLV in awake, spontaneously breathing animals. DESIGN: Animal case series SETTING: Cardiopulmonary physiology laboratory. SUBJECTS: Fifteen New Zealand white rabbits (3.2+/-0.39 kg). INTERVENTIONS: Animals were anesthetized and instrumented with a novel technique allowing percutaneously assisted placement of an intratracheal catheter with a subcutaneously tunneled externalized free end. After anesthetic recovery, PLV was performed in spontaneously breathing unsedated animals. MEASUREMENTS AND MAIN RESULTS: Evaporative losses were determined using a single 10 mL/kg perflubron dose (n = 5); hourly radiographs were obtained until residual perflubron was minimal. For prolonged PLV (n = 10), a 10-mL/kg initial perflubron dose was followed every 4 hrs with 5-mL/kg supplements. Radiographs were obtained immediately before and after perflubron administration and were scored (0-5) by a radiologist blinded to dosing regimen and time interval. Data were analyzed with ANOVA and Student's t-test with correction for multiple comparisons. Initial filling was nearly complete (score = 4.8+/-0.42); lungs were maintained approximately half-filled through 4 hrs (score = 2.53+/-0.71). By 6 hrs, the majority of perflubron had evaporated (score = 1.75+/-0.53). Over 24 hrs, radiographs documented continuous perflubron exposure (postffill = 4.53+/-0.64, prefill = 3.40+/-0.71, average = 3.97+/-0.43); scores were comparatively higher after filling (after = 4.53+/-0.64, before = 3.4+/-0.71, p< .001). Left and right lung volumes were equivalent (left = 4.06+/-0.47, right = 3.89+/-0.39, p = .027). All animals survived the 24 hrs of PLV. CONCLUSIONS: Percutaneously assisted intratracheal cannulation with catheter exteriorization permits prolonged PLV in spontaneously breathing, unsedated animals. Continuous perfluorocarbon exposure with this method is reproducible, consistent, and well tolerated for 24 hrs in uninjured animals.


Assuntos
Modelos Animais de Doenças , Fluorocarbonos/uso terapêutico , Intubação Intratraqueal/métodos , Respiração Artificial/métodos , Respiração , Vigília , Análise de Variância , Animais , Avaliação Pré-Clínica de Medicamentos , Hidrocarbonetos Bromados , Instilação de Medicamentos , Medidas de Volume Pulmonar , Coelhos , Respiração Artificial/efeitos adversos , Respiração Artificial/instrumentação , Método Simples-Cego , Fatores de Tempo , Traqueostomia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA