Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
J Am Chem Soc ; 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38885442

RESUMO

Synthesis of high-entropy oxide (HEO) nanocrystals has focused on increasing the temperature in the entropy term (T(ΔS)) to overcome the enthalpy term. However, these high temperatures lead to large, polydisperse nanocrystals. In this work, we leverage the low solubility product (Ksp) of metal oxides and optimize the Lewis-acid-catalyzed esterification reaction for equal rate production of the cation monomers to synthesize HEO nanocrystals at low temperatures, producing the smallest (<4 nm) and most monodisperse (<15% size dispersity) HEOs to date. We apply these HEO nanocrystals as electrocatalysts, exhibiting promising activity toward the oxygen evolution reaction in alkaline media, with an overpotential of 345 mV at 10 mA/cm2.

2.
J Am Chem Soc ; 145(31): 17406-17419, 2023 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-37525439

RESUMO

While certain ternary spinel oxides have been well-explored with colloidal nanochemistry, notably the ferrite spinel family, ternary manganese (Mn)-based spinel oxides have not been tamed. A key composition is cobalt (Co)-Mn oxide (CMO) spinel, CoxMn3-xO4, that, despite exemplary performance in multiple electrochemical applications, has few reports in the colloidal literature. Of these reports, most show aggregated and polydisperse products. Here, we describe a synthetic method for small, colloidally stable CMO spinel nanocrystals with tunable composition and low dispersity. By reacting 2+ metal-acetylacetonate (M(acac)2) precursors in an amine solvent under an oxidizing environment, we developed a pathway that avoids the highly reducing conditions of typical colloidal synthesis reactions; these reducing conditions typically push the system toward a monoxide impurity phase. Through surface chemistry studies, we identify organic byproducts and their formation mechanism, enabling us to engineer the surface and obtain colloidally stable nanocrystals with low organic loading. We report a CMO/carbon composite with low organic contents that performs the oxygen reduction reaction (ORR) with a half-wave potential (E1/2) of 0.87 V vs RHE in 1.0 M potassium hydroxide at 1600 rpm, rivaling previous reports for the highest activity of this material in ORR electrocatalysis. We extend the general applicability of this procedure to other Mn-based spinel nanocrystals such as Zn-Mn-O, Fe-Mn-O, Ni-Mn-O, and Cu-Mn-O. Finally, we show the scalability of this method by producing inorganic nanocrystals at the gram scale.

3.
Nat Mater ; 21(5): 518-525, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35422509

RESUMO

Spontaneous hierarchical self-organization of nanometre-scale subunits into higher-level complex structures is ubiquitous in nature. The creation of synthetic nanomaterials that mimic the self-organization of complex superstructures commonly seen in biomolecules has proved challenging due to the lack of biomolecule-like building blocks that feature versatile, programmable interactions to render structural complexity. In this study, highly aligned structures are obtained from an organic-inorganic mesophase composed of monodisperse Cd37S18 magic-size cluster building blocks. Impressively, structural alignment spans over six orders of magnitude in length scale: nanoscale magic-size clusters arrange into a hexagonal geometry organized inside micrometre-sized filaments; self-assembly of these filaments leads to fibres that then organize into uniform arrays of centimetre-scale bands with well-defined surface periodicity. Enhanced patterning can be achieved by controlling processing conditions, resulting in bullseye and 'zigzag' stacking patterns with periodicity in two directions. Overall, we demonstrate that colloidal nanomaterials can exhibit a high level of self-organization behaviour at macroscopic-length scales.


Assuntos
Nanoestruturas , Nanoestruturas/química
4.
J Chem Phys ; 159(1)2023 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-37409702

RESUMO

Cation exchange is a versatile post-synthetic method to explore a wide range of nanoparticle compositions, phases, and morphologies. Recently, several studies have expanded the scope of cation exchange to magic-size clusters (MSCs). Mechanistic studies indicated that MSC cation exchange undergoes a two-stage reaction pathway instead of the continuous diffusion-controlled mechanism found in nanoparticle cation exchange reactions. The cation exchange intermediate, however, has not been well-identified despite it being the key to understanding the reaction mechanism. Only indirect evidence, such as exciton peak shifts and powder x-ray diffraction, has been used to indicate the formation of the cation exchange intermediate. In this paper, we investigate the unusual nature of cation exchange in nanoclusters using our previously reported CdS MSC. High-resolution mass spectra reveal two cation exchanged reaction intermediates [Ag2Cd32S33(L) and AgCd33S33(L), L: oleic acid] as well as the fully exchanged Ag2S cluster. Crystal and electronic structure characterizations also confirm the two-stage reaction mechanism. Additionally, we investigate the Cu/CdS MSC cation exchange reaction and find a similar two-stage reaction mechanism. Our study shows that the formation of dilutely exchanged intermediate clusters can be generally found in the first stage of the MSC cation exchange reaction. By exchanging different cations, these intermediate clusters can access varying properties compared to their unexchanged counterparts.

5.
Chirality ; 35(11): 846-855, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37331723

RESUMO

Chiral materials with strong linear anisotropies are difficult to accurately characterize with circular dichroism (CD) because of artifactual contributions to their spectra from linear dichroism (LD) and birefringence (LB). Historically, researchers have used a second-order Taylor series expansion on the Mueller matrix to model the LDLB interaction effects on the spectra in conventional materials, but this approach may no longer be sufficient to account for the artifactual CD signals in emergent materials. In this work, we present an expression to model the measured CD using a third-order expansion, which introduces "pairwise interference" terms that, unlike the LDLB terms, cannot be averaged out of the signal. We find that the third-order pairwise interference terms can make noticeable contributions to the simulated CD spectra. Using numerical simulations of the measured CD across a broad range of linear and chiral anisotropy parameters, the LDLB interactions are most prominent in samples that have strong linear anisotropies (LD, LB) but negligible chiral anisotropies, where the measured CD strays from the chirality-induced CD by factors greater than 103 . Additionally, the pairwise interactions are most significant in systems with moderate-to-strong chiral and linear anisotropies, where the measured CD is inflated twofold, a figure that grows as linear anisotropies approach their maximum. In summary, media with moderate-to-strong linear anisotropy are in great danger of having their CD altered by these effects in subtle manners. This work highlights the significance of considering distortions in CD measurements through higher-order pairwise interference effects in highly anisotropic nanomaterials.

6.
Acc Chem Res ; 54(3): 509-519, 2021 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-33434011

RESUMO

ConspectusChemically induced transformations are postsynthetic processing reactions applied to first generation (as-synthesized) nanomaterials to modify property-defining factors such as atomic structure, chemical composition, surface chemistry, and/or morphology. Compared with conditions for direct synthesis of colloidal nanocrystals, postsynthetic chemical transformations can be conducted in relatively mild conditions with a more controllable process, which makes them suitable for the precise manipulation of nanomaterials and for trapping metastable phases that are typically inaccessible from the conventional synthetic routes. Each of the chemically induced transformations methods can result in substantial restructuring of the atomic structure, but their transformation pathways can be very different. And the converse is also true: the atomic structure of the parent material plays a large role in the pathway toward and the resulting chemically transformed product. Additionally, the characteristic length of the parent material greatly affects the structure, which affects the outcome of the reaction.In this Account, we show how the atomic structure and nanoscale size directs the product formation into materials that are inaccessible from analogous chemically transformations in bulk materials. Through examples from the three chemical transformation processes (cation/anion exchange, redox reactions, and ligand exchange and ligand etching), the effect of the atomic structure on chemical transformations is made apparent, and vice versa. For cation exchange, an anisotropic atomic lattice results in a unidirectional exchange boundary. And because the interface can extend through the full crystal, a substantial strain field can form, influencing the phase of the material. In the redox reaction that leads to the nanoscale Kirkendall effect, the atomic structure is the key to inverting the diffusion rates in a diffusion couple to form the hollow cores. And for ligand etching, if one of the materials in a heterostructure has a defected and\or defect-tolerant atomic structure, it can be preferentially etched and its atomic structure can undergo phase transformations while the other composition remains intact. For length scales, we show how the chemically induced transformations greatly differ between bulk, nanocrystal, and nanocluster characteristic sizes. For instance, the structural transformation on relatively large nanocrystals (2-100 nm) can be a continuous process when the activation volume is smaller than the nanocrystal, while for smaller nanoclusters (<2 nm) the transformation kinetics could be swift resulting in only discrete thermodynamic states. Comparing the two nanosystems (nanocrystals to small nanoclusters), we address how their atomic structural differences can direct the divergent transformation phenomena and the corresponding mechanisms. Understanding the nanoscale mechanisms of chemically induced transformations and how they differ from bulk processes is key to unlocking new science and for implementing this processing for functional materials.

7.
J Chem Phys ; 155(14): 144702, 2021 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-34654287

RESUMO

Efforts to improve energy storage depend greatly on the development of efficient electrode materials. Recently, strain has been employed as an alternate approach to improve ion mobility. While lattice strain has been well-researched in catalytic applications, its effects on electrochemical energy storage are largely limited to computational studies due to complexities associated with strain control in nanomaterials as well as loss of strain due to the phase change of the active material during charging-discharging. In this work, we overcome these challenges and investigate the effects of strain on supercapacitor performance in Li-ion-based energy devices. We synthesize epitaxial Fe3O4@MnFe2O4 (core@shell) nanoparticles with varying shell thickness to control the lattice strain. A narrow voltage window for electrochemical testing is used to limit the storage mechanism to lithiation-delithiation, preventing a phase change and maintaining structural strain. Cyclic voltammetry reveals a pseudocapacitive behavior and similar levels of surface charge storage in both strained- and unstrained-MnFe2O4 samples; however, diffusive charge storage in the strained sample is twice as high as the unstrained sample. The strained-MnFe2O4 electrode exceeds the performance of the unstrained-MnFe2O4 electrode in energy density by ∼33%, power density by ∼28%, and specific capacitance by ∼48%. Density functional theory shows lower formation energies for Li-intercalation and lower activation barrier for Li-diffusion in strained-MnFe2O4, corresponding to a threefold increase in the diffusion coefficient. The enhanced Li-ion diffusion rate in the strained-electrodes is further confirmed using the galvanostatic intermittent titration technique. This work provides a starting point to using strain engineering as a novel approach for designing high performance energy storage devices.

8.
J Am Chem Soc ; 142(34): 14495-14503, 2020 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-32786802

RESUMO

Self-assembly of three-dimensional structures with order across multiple length scales-hierarchical assembly-is of great importance for biomolecules for the functions of life. Creation of similar complex architectures from inorganic building blocks has been pursued toward artificial biomaterials and advanced functional materials. Current research, however, primarily employs only large, nonreactive building blocks such as Au colloids. By contrast, sulfur-bridged transition metal clusters (<2 nm) are able to offer more functionality in catalytic and biochemical reactions. Hierarchical assembly of these systems has not been well researched because of the difficulty in obtaining single-phase clusters and the lack of suitable ligands to direct structure construction. To overcome these challenges, we employ a rigid planar ligand with an aromatic ring and bifunctional bond sites. We demonstrate the synthesis and assembly of 1.2 nm sulfur-bridged copper (SB-Cu) clusters with tertiary hierarchical complexity. The primary structure is clockwise/counterclockwise chiral cap and core molecules. They combine to form clusters, and due to the cap-core interaction (C-H···π), only two enantiomeric isomers are formed (secondary structure). A tertiary hierarchical architecture is achieved through the self-assembly of alternating enantiomers with hydrogen bonds as the intermolecular driving force. The SB-Cu clusters are air stable and have a distribution of oxidation states ranging from Cu(0) to Cu(I), making them interesting for redox and catalytic activities. This study shows that structural complexity at different length scales, mimicking biomolecules, can occur in active-metal clusters and provides a new platform for investigation of those systems and for the design of advanced functional materials.

9.
Ann Emerg Med ; 74(2): 187-203, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30718010

RESUMO

STUDY OBJECTIVE: The objectives of this systematic review and meta-analysis are to appraise the evidence in regard to the diagnostic accuracy of a low-risk History, ECG, Age, Risk Factors, and Troponin (HEART) score for prediction of major adverse cardiac events in emergency department (ED) patients. These included 4 subgroup analyses: by geographic region, the use of a modified low-risk HEART score (traditional HEART score [0 to 3] in addition to negative troponin results), using conventional versus high-sensitivity troponin assays in the HEART score, and a comparison of different post-ED-discharge patient follow-up intervals. METHODS: We searched MEDLINE, EBSCO, Web of Science, and Cochrane Database for studies on the diagnostic performance of low-risk HEART scores to predict major adverse cardiac events among ED chest pain patients. Two reviewers independently screened articles for inclusion, assessed the quality of studies with both an adapted Quality Assessment of Diagnostic Accuracy Studies version 2 tool and an internally developed tool that combined components of the Quality in Prognostic Studies; Checklist for Critical Appraisal and Data Extraction for Systematic Reviews of Prediction Modelling Studies; and Grading of Recommendations Assessment, Development and Evaluation. Pooled sensitivity, specificity, positive predictive value, negative predictive value, and positive and negative likelihood ratios were calculated. RESULTS: There were 25 studies published from 2010 to 2017, with a total of 25,266 patients included in the final meta-analysis, of whom 9,919 (39.3%) were deemed to have low-risk HEART scores (0 to 3). Among patients with low-risk HEART scores, short-term major adverse cardiac events (30 days to 6 weeks) occurred in 2.1% of the population (182/8,832) compared with 21.9% of patients (3,290/15,038) with non-low-risk HEART scores (4 to 10). For patients with HEART scores of 0 to 3, the pooled sensitivity of short-term major adverse cardiac event predictions was 0.96 (95% confidence interval [CI] 0.93 to 0.98), specificity was 0.42 (95% CI 0.36 to 0.49), positive predictive value was 0.19 (95% CI 0.14 to 0.24), negative predictive value was 0.99 (95% CI 0.98 to 0.99), positive likelihood ratio was 1.66 (95% CI 1.50 to 1.85), and negative likelihood ratio was 0.09 (95% CI 0.06 to 0.15). Subgroup analysis showed that lower short-term major adverse cardiac events occurred among North American patients (0.7%), occurred when modified low-risk HEART score was used (0.8%), or occurred when high-sensitivity troponin was used for low-risk HEART score calculations (0.8%). CONCLUSION: In this meta-analysis, despite its use in different patient populations, the troponin type used, and timeline of follow-up, a low-risk HEART score had high sensitivity, negative predictive value, and negative likelihood ratio for predicting short-term major adverse cardiac events, although risk of bias and statistical heterogeneity were high.


Assuntos
Dor no Peito/diagnóstico , Dor no Peito/epidemiologia , Cardiopatias/complicações , Troponina/sangue , Síndrome Coronariana Aguda/diagnóstico , Doença Aguda , Dor no Peito/etiologia , Unidades de Observação Clínica/normas , Eletrocardiografia/métodos , Serviço Hospitalar de Emergência , Feminino , Cardiopatias/sangue , Cardiopatias/diagnóstico , Cardiopatias/fisiopatologia , Humanos , Masculino , Infarto do Miocárdio/diagnóstico , Alta do Paciente/tendências , Valor Preditivo dos Testes , Prognóstico , Medição de Risco , Fatores de Risco , Sensibilidade e Especificidade
10.
Am J Emerg Med ; 37(4): 579-584, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30139579

RESUMO

OBJECTIVE: Trauma Quality Improvement Program participation among all trauma centers has shown to improve patient outcomes. We aim to identify trauma quality events occurring during the Emergency Department (ED) phase of care. METHODS: This is a single-center observational study using consecutively registered data in local trauma registry (Jan 1, 2016-Jun 30, 2017). Four ED crowding scores as determined by four different crowding estimation tools were assigned to each enrolled patient upon arrival to the ED. Patient related (age, gender, race, severity of illness, ED disposition), system related (crowding, night shift, ED LOS), and provider related risk factors were analyzed in a multivariate logistic regression model to determine associations relative to ED quality events. RESULTS: Total 5160 cases were enrolled among which, 605 cases were deemed ED quality improvement (QI) cases and 457 cases were ED provider related. Similar percentages of ED QI cases (10-12%) occurred across the ED crowding status range. No significant difference was appreciated in terms of predictability of ED QI cases relative to different crowding status after adjustment for potential confounders. However, an adjusted odds ratio of 1.64 (95% CI, 1.17-2.30, p < 0.01) regarding ED LOS ≥2 h predictive of ED related quality issues was noted when analyzed using multivariate logistic regression. CONCLUSION: Provider related issues are a common contributor to undesirable outcomes in trauma care. ED crowding lacks significant association with poor trauma quality care. Prolonged ED LOS (≥2 h) appears to be linked with unfavorable outcomes in ED trauma care.


Assuntos
Aglomeração , Serviço Hospitalar de Emergência/estatística & dados numéricos , Melhoria de Qualidade/organização & administração , Centros de Traumatologia/organização & administração , Adulto , Eficiência Organizacional , Tratamento de Emergência , Feminino , Humanos , Tempo de Internação/estatística & dados numéricos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Retrospectivos , Fatores de Risco , Texas
11.
BMC Health Serv Res ; 19(1): 451, 2019 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-31272442

RESUMO

BACKGROUND: It is critical to understand whether providing health insurance coverage, assigning a dedicated Primary Care Physician (PCP), and arranging timely post-Emergency Department (ED) clinic follow-up can improve compliance with clinic visits and reduce ED discharge failures. We aim to determine the benefits of providing these common step-wise interventions and further investigate the necessity of urgent PCP referrals on behalf of ED discharged patients. METHODS: This is a single-center retrospective observational study. All patients discharged from the ED over the period Jan 1, 2015 through Dec 31, 2017 were included in the study population. Step-wise interventions included providing charity health insurance, assigning a dedicated PCP, and providing ED follow-up clinics. PCP clinic compliance and ED discharge failures were measured and compared among groups receiving different interventions. RESULT: A total of 227,627 patients were included. Fifty-eight percent of patients receiving charity insurance had PCP visits in comparison to 23% of patients without charity insurance (p < 0.001). Seventy-seven percent of patients with charity insurance and PCP assignments completed post-ED discharge PCP visits in comparison to only 4.5% of those with neither charity insurance nor PCP assignments (p < 0.001). CONCLUSIONS: Step-wise interventions increased patient clinic follow-up compliance while simultaneously reducing ED discharge failures. Such interventions might benefit communities with similar patient populations.


Assuntos
Assistência Ambulatorial/estatística & dados numéricos , Serviço Hospitalar de Emergência/estatística & dados numéricos , Alta do Paciente/estatística & dados numéricos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cooperação do Paciente , Melhoria de Qualidade , Estudos Retrospectivos
12.
J Am Chem Soc ; 140(10): 3652-3662, 2018 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-29376343

RESUMO

Magic-sized clusters (MSCs) are renowned for their identical size and closed-shell stability that inhibit conventional nanoparticle (NP) growth processes. Though MSCs have been of increasing interest, understanding the reaction pathways toward their nucleation and stabilization is an outstanding issue. In this work, we demonstrate that high concentration synthesis (1000 mM) promotes a well-defined reaction pathway to form high-purity MSCs (>99.9%). The MSCs are resistant to typical growth and dissolution processes. On the basis of insights from in situ X-ray scattering analysis, we attribute this stability to the accompanying production of a large (>100 nm grain size), hexagonal organic-inorganic mesophase that arrests growth of the MSCs and prevents NP growth. At intermediate concentrations (500 mM), the MSC mesophase forms, but is unstable, resulting in NP growth at the expense of the assemblies. These results provide an alternate explanation for the high stability of MSCs. Whereas the conventional mantra has been that the stability of MSCs derives from the precise arrangement of the inorganic structures (i.e., closed-shell atomic packing), we demonstrate that anisotropic clusters can also be stabilized by self-forming fibrous mesophase assemblies. At lower concentration (<200 mM or >16 acid-to-metal), MSCs are further destabilized and NPs formation dominates that of MSCs. Overall, the high concentration approach intensifies and showcases inherent concentration-dependent surfactant phase behavior that is not accessible in conventional (i.e., dilute) conditions. This work provides not only a robust method to synthesize, stabilize, and study identical MSC products but also uncovers an underappreciated stabilizing interaction between surfactants and clusters.

13.
Phys Chem Chem Phys ; 20(46): 28990-29000, 2018 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-30238093

RESUMO

Cation site occupation is an important determinant of materials properties, especially in a complex system with multiple cations such as in ternary spinels. Many methods for extracting the cation site information have been explored in the past, including analysis of spectra obtained through K-edge X-ray absorption spectroscopy (XAS). In this work, we measure the effectiveness of X-ray emission spectroscopy (XES) for determining the cation site occupation. As a test system we use spinel phase CoxMn3-xO4 nanoparticles contaminated with CoO phases because Co and Mn can occupy all cation sites and the impurity simulates typical products of oxide syntheses. We take advantage of the spin and oxidation state sensitive Kß1,3 peak obtained using XES and demonstrate that XES is a powerful and reliable technique for determining site occupation in ternary spinel systems. Comparison between the extended X-ray absorption fine structure (EXAFS) and XES techniques reveals that XES provides not only the site occupation information as EXAFS, but also additional information on the oxidation states of the cations at each site. We show that the error for EXAFS can be as high as 35% which makes the results obtained ambiguous for certain stoichiometries, whereas for XES, the error determined is consistently smaller than 10%. Thus, we conclude that XES is a superior and a far more accurate method than XAS in extracting cation site occupation in spinel crystal structures.

14.
BMC Health Serv Res ; 18(1): 59, 2018 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-29378577

RESUMO

BACKGROUND: Prolonged hospital discharge boarding can impact patient flow resulting in upstream Emergency Department crowding. We aim to determine the risks predicting prolonged hospital discharge boarding and their direct and indirect effects on patient flow. METHODS: Retrospective review of a single hospital discharge database was conducted. Variables including type of disposition, disposition boarding time, case management consultation, discharge medications prescriptions, severity of illness, and patient homeless status were analyzed in a multivariate logistic regression model. Hospital charges, potential savings of hospital bed hours, and whether detailed discharge instructions provided adequate explanations to patients were also analyzed. RESULTS: A total of 11,527 admissions was entered into final analysis. The median discharge boarding time was approximately 2 h. Adjusted Odds Ratio (AOR) of patients transferring to other hospitals was 7.45 (95% CI 5.35-10.37), to court or law enforcement custody was 2.51 (95% CI 1.84-3.42), and to a skilled nursing facility was 2.48 (95% CI 2.10-2.93). AOR was 0.57 (95% CI 0.47-0.71) if the disposition order was placed during normal office hours (0800-1700). AOR of early case management consultation was 1.52 (95% CI 1.37-1.68) versus 1.73 (95% CI 1.03-2.89) for late consultation. Eighty-eight percent of patients experiencing discharge boarding times within 2 h of disposition expressed positive responses when questioned about the quality of explanations of discharge instructions and follow-up plans based on satisfaction surveys. Similar results (86% positive response) were noted among patients whose discharge boarding times were prolonged (> 2 h, p = 0.44). An average charge of $6/bed/h was noted in all hospital discharges. Maximizing early discharge boarding (≤ 2 h) would have resulted in 16,376 hospital bed hours saved thereby averting $98,256.00 in unnecessary dwell time charges in this study population alone. CONCLUSION: Type of disposition, case management timely consultation, and disposition to discharge dwell time affect boarding and patient flow in a tertiary acute care hospital. Efficiency of the discharge process did not affect patient satisfaction relative to the perceived quality of discharge instruction and follow-up plan explanations. Prolonged disposition to discharge intervals result in unnecessary hospital bed occupancy thereby negatively impacting hospital finances while delivering no direct benefit to patients.


Assuntos
Serviço Hospitalar de Emergência/organização & administração , Hospitalização/estatística & dados numéricos , Tempo de Internação/estatística & dados numéricos , Alta do Paciente/estatística & dados numéricos , Adulto , Aglomeração , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Satisfação do Paciente , Estudos Retrospectivos , Fatores de Risco
15.
Ann Emerg Med ; 70(5): 632-639.e4, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28688771

RESUMO

STUDY OBJECTIVE: Emergency department (ED) crowding is a barrier to timely care. Several crowding estimation tools have been developed to facilitate early identification of and intervention for crowding. Nevertheless, the ideal frequency is unclear for measuring ED crowding by using these tools. Short intervals may be resource intensive, whereas long ones may not be suitable for early identification. Therefore, we aim to assess whether outcomes vary by measurement interval for 4 crowding estimation tools. METHODS: Our eligible population included all patients between July 1, 2015, and June 30, 2016, who were admitted to the JPS Health Network ED, which serves an urban population. We generated 1-, 2-, 3-, and 4-hour ED crowding scores for each patient, using 4 crowding estimation tools (National Emergency Department Overcrowding Scale [NEDOCS], Severely Overcrowded, Overcrowded, and Not Overcrowded Estimation Tool [SONET], Emergency Department Work Index [EDWIN], and ED Occupancy Rate). Our outcomes of interest included ED length of stay (minutes) and left without being seen or eloped within 4 hours. We used accelerated failure time models to estimate interval-specific time ratios and corresponding 95% confidence limits for length of stay, in which the 1-hour interval was the reference. In addition, we used binomial regression with a log link to estimate risk ratios (RRs) and corresponding confidence limit for left without being seen. RESULTS: Our study population comprised 117,442 patients. The time ratios for length of stay were similar across intervals for each crowding estimation tool (time ratio=1.37 to 1.30 for NEDOCS, 1.44 to 1.37 for SONET, 1.32 to 1.27 for EDWIN, and 1.28 to 1.23 for ED Occupancy Rate). The RRs of left without being seen differences were also similar across intervals for each tool (RR=2.92 to 2.56 for NEDOCS, 3.61 to 3.36 for SONET, 2.65 to 2.40 for EDWIN, and 2.44 to 2.14 for ED Occupancy Rate). CONCLUSION: Our findings suggest limited variation in length of stay or left without being seen between intervals (1 to 4 hours) regardless of which of the 4 crowding estimation tools were used. Consequently, 4 hours may be a reasonable interval for assessing crowding with these tools, which could substantially reduce the burden on ED personnel by requiring less frequent assessment of crowding.


Assuntos
Aglomeração , Coleta de Dados/métodos , Precisão da Medição Dimensional , Serviço Hospitalar de Emergência/estatística & dados numéricos , Estatística como Assunto/métodos , Adulto , Estudos de Coortes , Feminino , Humanos , Tempo de Internação/estatística & dados numéricos , Tempo de Internação/tendências , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Valor Preditivo dos Testes , Carga de Trabalho/estatística & dados numéricos
16.
Int J Qual Health Care ; 29(5): 722-727, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-28992161

RESUMO

OBJECTIVE: To evaluate the associations between real-time overall patient satisfaction and Emergency Department (ED) crowding as determined by patient percepton and crowding estimation tool score in a high-volume ED. DESIGN: A prospective observational study. SETTING: A tertiary acute hospital ED and a Level 1 trauma center. PARTICIPANTS: ED patients. INTERVENTION(S): Crowding status was measured by two crowding tools [National Emergency Department Overcrowding Scale (NEDOCS) and Severely overcrowded-Overcrowded-Not overcrowded Estimation Tool (SONET)] and patient perception of crowding surveys administered at discharge. MAIN OUTCOME MEASURE(S): ED crowding and patient real-time satisfaction. RESULTS: From 29 November 2015 through 11 January 2016, we enrolled 1345 participants. We observed considerable agreement between the NEDOCS and SONET assessment of ED crowding (bias = 0.22; 95% limits of agreement (LOAs): -1.67, 2.12). However, agreement was more variable between patient perceptions of ED crowding with NEDOCS (bias = 0.62; 95% LOA: -5.85, 7.09) and SONET (bias = 0.40; 95% LOA: -5.81, 6.61). Compared to not overcrowded, there were overall inverse associations between ED overcrowding and patient satisfaction (Patient perception OR = 0.49, 95% confidence limit (CL): 0.38, 0.63; NEDOCS OR = 0.78, 95% CL: 0.65, 0.95; SONET OR = 0.82, 95% CL: 0.69, 0.98). CONCLUSIONS: While heterogeneity exists in the degree of agreement between objective and patient perceived assessments of ED crowding, in our study we observed that higher degrees of ED crowding at admission might be associated with lower real-time patient satisfaction.


Assuntos
Aglomeração/psicologia , Serviço Hospitalar de Emergência/estatística & dados numéricos , Satisfação do Paciente/estatística & dados numéricos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Inquéritos e Questionários , Centros de Atenção Terciária , Texas , Centros de Traumatologia
17.
BMC Health Serv Res ; 16(1): 564, 2016 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-27724889

RESUMO

BACKGROUND: Risks prediction models of 30-day all-cause hospital readmissions are multi-factorial. Severity of illness (SOI) and risk of mortality (ROM) categorized by All Patient Refined Diagnosis Related Groups (APR-DRG) seem to predict hospital readmission but lack large sample validation. Effects of risk reduction interventions including providing post-discharge outpatient visits remain uncertain. We aim to determine the accuracy of using SOI and ROM to predict readmission and further investigate the role of outpatient visits in association with hospital readmission. METHODS: Hospital readmission data were reviewed retrospectively from September 2012 through June 2015. Patient demographics and clinical variables including insurance type, homeless status, substance abuse, psychiatric problems, length of stay, SOI, ROM, ICD-10 diagnoses and medications prescribed at discharge, and prescription ratio at discharge (number of medications prescribed divided by number of ICD-10 diagnoses) were analyzed using logistic regression. Relationships among SOI, type of hospital visits, time between hospital visits, and readmissions were also investigated. RESULTS: A total of 6011 readmissions occurred from 55,532 index admissions. The adjusted odds ratios of SOI and ROM predicting readmissions were 1.31 (SOI: 95 % CI 1.25-1.38) and 1.09 (ROM: 95 % CI 1.05-1.14) separately. Ninety percent (5381/6011) of patients were readmitted from the Emergency Department (ED) or Urgent Care Center (UCC). Average time interval from index discharge date to ED/UCC visit was 9 days in both the no readmission and readmission groups (p > 0.05). Similar hospital readmission rates were noted during the first 10 days from index discharge regardless of whether post-index discharge patient clinic visits occurred when time-to-event analysis was performed. CONCLUSIONS: SOI and ROM significantly predict hospital readmission risk in general. Most readmissions occurred among patients presenting for ED/UCC visits after index discharge. Simply providing early post-discharge follow-up clinic visits does not seem to prevent hospital readmissions.


Assuntos
Assistência ao Convalescente , Assistência Ambulatorial/estatística & dados numéricos , Readmissão do Paciente/estatística & dados numéricos , Adulto , Grupos Diagnósticos Relacionados , Feminino , Pessoas Mal Alojadas , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Índice de Gravidade de Doença , Análise de Sobrevida
18.
J Am Chem Soc ; 137(50): 15843-51, 2015 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-26592380

RESUMO

Realizing the promise of nanoparticle-based technologies demands more efficient, robust synthesis methods (i.e., process intensification) that consistently produce large quantities of high-quality nanoparticles (NPs). We explored NP synthesis via the heat-up method in a regime of previously unexplored high concentrations near the solubility limit of the precursors. We discovered that in this highly concentrated and viscous regime the NP synthesis parameters are less sensitive to experimental variability and thereby provide a robust, scalable, and size-focusing NP synthesis. Specifically, we synthesize high-quality metal sulfide NPs (<7% relative standard deviation for Cu2-xS and CdS), and demonstrate a 10-1000-fold increase in Cu2-xS NP production (>200 g) relative to the current field of large-scale (0.1-5 g yields) and laboratory-scale (<0.1 g) efforts. Compared to conventional synthesis methods (hot injection with dilute precursor concentration) characterized by rapid growth and low yield, our highly concentrated NP system supplies remarkably controlled growth rates and a 10-fold increase in NP volumetric production capacity (86 g/L). The controlled growth, high yield, and robust nature of highly concentrated solutions can facilitate large-scale nanomanufacturing of NPs by relaxing the synthesis requirements to achieve monodisperse products. Mechanistically, our investigation of the thermal and rheological properties and growth rates reveals that this high concentration regime has reduced mass diffusion (a 5-fold increase in solution viscosity), is stable to thermal perturbations (∼64% increase in heat capacity), and is resistant to Ostwald ripening.

19.
Am J Emerg Med ; 33(8): 1006-11, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26001738

RESUMO

OBJECTIVE: Homeless patients are a vulnerable population with a higher incidence of using the emergency department (ED) for noncrisis care. Multiple charity programs target their outreach toward improving the health of homeless patients, but few data are available on the effectiveness of reducing ED recidivism. The aim of this study is to determine whether inappropriate ED use for nonemergency care may be reduced by providing charity insurance and assigning homeless patients to a primary care physician (PCP) in an outpatient clinic setting. METHODS: A retrospective medical records review of homeless patients presenting to the ED and receiving treatment between July 2013 and June 2014 was completed. Appropriate vs inappropriate use of the ED was determined using the New York University ED Algorithm. The association between patients with charity care coverage, PCP assignment status, and appropriate vs inappropriate ED use was analyzed and compared. RESULTS: Following New York University ED Algorithm standards, 76% of all ED visits were deemed inappropriate with approximately 77% of homeless patients receiving charity care and 74% of patients with no insurance seeking noncrisis health care in the ED (P=.112). About 50% of inappropriate ED visits and 43.84% of appropriate ED visits occurred in patients with a PCP assignment (P=.019). CONCLUSIONS: Both charity care homeless patients and those without insurance coverage tend to use the ED for noncrisis care resulting in high rates of inappropriate ED use. Simply providing charity care and/or PCP assignment does not seem to sufficiently reduce inappropriate ED use in homeless patients.


Assuntos
Instituições de Caridade/estatística & dados numéricos , Serviço Hospitalar de Emergência/estatística & dados numéricos , Mau Uso de Serviços de Saúde/estatística & dados numéricos , Pessoas Mal Alojadas/estatística & dados numéricos , Pessoas sem Cobertura de Seguro de Saúde/estatística & dados numéricos , Atenção Primária à Saúde/estatística & dados numéricos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
20.
Nano Lett ; 14(2): 403-15, 2014 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-24256332

RESUMO

Thermal transport in nanostructures is strongly affected by phonon-surface interactions, which are expected to depend on the phonon's wavelength and the surface roughness. Here we fabricate silicon nanosheets, measure their surface roughness (∼ 1 nm) using atomic force microscopy (AFM), and assess the phonon scattering rate in the sheets with a novel technique: a microscale phonon spectrometer. The spectrometer employs superconducting tunnel junctions (STJs) to produce and detect controllable nonthermal distributions of phonons from ∼ 90 to ∼ 870 GHz. This technique offers spectral resolution nearly 10 times better than a thermal conductance measurement. We compare measured phonon transmission rates to rates predicted by a Monte Carlo model of phonon trajectories, assuming that these trajectories are dominated by phonon-surface interactions and using the Ziman theory to predict phonon-surface scattering rates based on surface topology. Whereas theory predicts a diffuse surface scattering probability of less than 40%, our measurements are consistent with a 100% probability. Our nanosheets therefore exhibit the so-called "Casimir limit" at a much lower frequency than expected if the phonon scattering rates follow the Ziman theory for a 1 nm surface roughness. Such a result holds implications for thermal management in nanoscale electronics and the design of nanostructured thermoelectrics.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA