Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Rev Esp Enferm Dig ; 109(5): 322-327, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28229607

RESUMO

INTRODUCTION: Colon capsule endoscopy (CCE) is an alternative approach for the examination of the colon in patients who refuse colonoscopy or after incomplete colonoscopy (IC). We conducted a study to determine the frequency of complete colonoscopy after IC, the diagnostic yield of CCE, the therapeutic impact of lesions found in CCE, the level of colon cleanliness and the safety of the procedure. METHODS: We performed a prospective, multicenter study involving ten Spanish hospitals. Consecutive outpatients aged ≥ 18 years with previous IC were invited to participate. The latest version of the CCE device, PillCam™ COLON 2 (CCE-2), was administered to all patients according to the protocol. RESULTS: The study population comprised 96 patients. The most frequent cause of IC was the inability to move past a loop using standard maneuvers (75/96 patients, 78%). Complete visualization of the colon was obtained with CCE-2 in 69 patients (71.9%). Of the 27 patients in whom the CCE-2 did not reach the hemorrhoidal plexus, it passed the colonic segment explored with the previous colonoscopy in 20 cases; therefore, it could be inferred that a combined approach (CCE-2 plus colonoscopy) enabled complete visualization of the colonic mucosa in 92.7% of patients. CCE-2 revealed new lesions in 58 patients (60.4%). Polyps were the most frequent finding (41 patients; 42.7% of the total number of patients). In 43 of the 58 patients (44.8% of the total number of patients), the new lesions observed led to modification of therapy, which included a new colonoscopy for polyp resection or surgery in patients with colonic neoplasm. CONCLUSIONS: CCE-2 is a suitable diagnostic procedure that can lead to more frequent diagnosis of significant colonic lesions after IC.


Assuntos
Endoscopia por Cápsula/instrumentação , Colo/diagnóstico por imagem , Neoplasias do Colo/diagnóstico por imagem , Pólipos do Colo/diagnóstico por imagem , Colonoscopia , Diverticulose Cólica/diagnóstico por imagem , Mucosa Intestinal/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Espanha
2.
Rev Esp Enferm Dig ; 106(2): 98-102, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24852735

RESUMO

BACKGROUND: Endoscopic submucosal dissection (ESD) is an effective but time-consuming treatment for early neoplasia that requires a high level of expertise. OBJECTIVE: The objective of this study was to assess the efficacy and learning curve of gastric ESD with a hybrid knife with high pressure water jet and to compare with standard ESD. MATERIAL AND METHODS: We performed a prospective non survival animal study comparing hybrid-knife and standard gastric ESD. Variables recorded were: Number of en-bloc ESD, number of ESD with all marks included (R0), size of specimens, time and speed of dissection and adverse events. Ten endoscopists performed a total of 50 gastric ESD (30 hybrid-knife and 20 standard). RESULTS: Forty-six (92 %) ESD were en-bloc and 25 (50 %) R0 (hybrid-knife: n = 13, 44 %; standard: n = 16, 80 %; p = 0.04). Hybrid-knife ESD was faster than standard (time: 44.6 +/- 21.4 minutes vs. 68.7 +/- 33.5 minutes; p = 0.009 and velocity: 20.8 +/- 9.2 mm(2)/min vs. 14.3 +/- 9.3 mm(2)/min (p = 0.079). Adverse events were not different. There was no change in speed with any of two techniques (hybrid-knife: From 20.33 +/- 15.68 to 28.18 +/- 20.07 mm(2)/min; p = 0.615 and standard: From 6.4 +/- 0.3 to 19.48 +/- 19.21 mm(2)/min; p = 0.607). The learning curve showed a significant improvement in R0 rate in the hybrid-knife group (from 30 % to 100 %). CONCLUSION: despite the initial performance of hybrid-knife ESD is worse than standard ESD, the learning curve with hybrid knife ESD is short and is associated with a rapid improvement. The introduction of new tools to facilitate ESD should be implemented with caution in order to avoid a negative impact on the results.


Assuntos
Endoscopia Gastrointestinal/instrumentação , Endoscopia Gastrointestinal/métodos , Neoplasias Gástricas/cirurgia , Instrumentos Cirúrgicos , Animais , Endoscopia Gastrointestinal/efeitos adversos , Curva de Aprendizado , Masculino , Suínos
3.
Rev Esp Enferm Dig ; 105(9): 544-52, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24467499

RESUMO

Endoscopic submucosal dissection (ESD) allows endoscopic, curative, en-bloc resection of superficial malignant or premalignant lesions. This procedure was conceived over 10 years ago in Japan, but has not experienced great expansion in Western countries for different reasons. This article reviews ESD indications and outcomes, and reflects on the reasons that prevent ESD from becoming common clinical practice in Western hospitals. Finally, recommendations on ESD training in our setting are made.


Assuntos
Endoscopia Gastrointestinal/métodos , Mucosa Gástrica/cirurgia , Neoplasias Gástricas/cirurgia , Difusão de Inovações , Endoscopia Gastrointestinal/estatística & dados numéricos , Humanos , Espanha , Resultado do Tratamento
4.
Surg Endosc ; 26(1): 222-9, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21858574

RESUMO

BACKGROUND: Endoscopic biliary stenting is a well-established palliative treatment in patients with unresectable malignant biliary strictures. Obstruction of uncovered self-expanding metal stent (SEMS) due to tumor ingrowth is the most frequent complication. Partially covered SEMS might increase stent patency but could favor complications related to stent covering, such as pancreatitis, cholecystitis, and migration. The aim of this study was to evaluate the efficacy and safety of partially covered SEMS in patients with an unresectable malignant biliary stricture. METHODS: Patients with malignant extrahepatic biliary obstruction treated endoscopically with partially covered SEMS were included in this multicenter, prospective, nonrandomized study. RESULTS: One hundred ninety-nine patients were endoscopically treated with partially covered SEMS in 32 Spanish hospitals. Clinical success after deep cannulation was 96%. Early complications occurred in 4% (3 pancreatitis, 2 cholangitis, 1 hemorrhage, 1 perforation, and 1 cholecystitis). Late complications occurred in 19.5% (18 obstructions, 10 migrations, 6 cholangitis without obstruction, 3 acute cholecystitis, and 2 pancreatitis), with no tumor ingrowth in any case. Median stent patency was 138.9 ± 112.6 days. One-year actuarial probability of stent patency was 70% and that of nonmigration was 86%. Multivariate analysis showed adjuvant radio- or chemotherapy as the only independent predictive factor of stent patency and previous insertion of a biliary stent was the only predictive factor of migration. CONCLUSIONS: The partially covered SEMS was easily inserted, had a high clinical success rate, and prevented tumor ingrowth. The incidence of possible complications related to stent coverage, namely, migration, pancreatitis, and cholecystitis, was lower than in previously published series.


Assuntos
Neoplasias do Sistema Biliar/cirurgia , Colestase Extra-Hepática/cirurgia , Stents , Idoso , Idoso de 80 Anos ou mais , Neoplasias do Sistema Biliar/complicações , Neoplasias do Sistema Biliar/mortalidade , Colangiopancreatografia Retrógrada Endoscópica , Colestase Extra-Hepática/etiologia , Colestase Extra-Hepática/mortalidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Cuidados Paliativos/métodos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Estudos Prospectivos , Falha de Prótese/efeitos adversos
6.
Dig Dis Sci ; 47(6): 1224-9, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12064795

RESUMO

We present a case of a chronic hepatitis C with damage of bile ducts resembling primary biliary cirrhosis. The immunological profile (negative antimitochondrial antibodies and positive anti-nuclear antibody) was characteristic of the autoimmune cholangitis. One year of treatment with ursodeoxycholic acid returned the liver tests to the normal range but the liver lesions remained unchanged.


Assuntos
Doenças Autoimunes/patologia , Colangite/patologia , Hepatite C Crônica/patologia , Fígado/patologia , Colagogos e Coleréticos/uso terapêutico , Feminino , Hepatite C Crônica/tratamento farmacológico , Humanos , Pessoa de Meia-Idade , Mitocôndrias Hepáticas/imunologia , Ácido Ursodesoxicólico/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA